• Title/Summary/Keyword: Vacuum discharge tube

Search Result 36, Processing Time 0.036 seconds

Development of RF Ion Source for Neutral Beam Injector in Fusion Devices

  • Jang, Du-Hui;Park, Min;Kim, Seon-Ho;Jeong, Seung-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.550-551
    • /
    • 2013
  • Large-area RF-driven ion source is being developed at Germany for the heating and current drive of ITER plasmas. Negative hydrogen (deuterium) ion sources are major components of neutral beam injection systems in future large-scale fusion experiments such as ITER and DEMO. RF ion sources for the production of positive hydrogen ions have been successfully developed at IPP (Max-Planck- Institute for Plasma Physics, Garching) for ASDEX-U and W7-AS neutral beam injection (NBI) systems. In recent, the first NBI system (NBI-1) has been developed successfully for the KSTAR. The first and second long-pulse ion sources (LPIS-1 and LPIS-2) of NBI-1 system consist of a magnetic bucket plasma generator with multi-pole cusp fields, filament heating structure, and a set of tetrode accelerators with circular apertures. There is a development plan of large-area RF ion source at KAERI to extract the positive ions, which can be used for the second NBI (NBI-2) system of KSTAR, and to extract the negative ions for future fusion devices such as ITER and K-DEMO. The large-area RF ion source consists of a driver region, including a helical antenna (6-turn copper tube with an outer diameter of 6 mm) and a discharge chamber (ceramic and/or quartz tubes with an inner diameter of 200 mm, a height of 150 mm, and a thickness of 8 mm), and an expansion region (magnetic bucket of prototype LPIS in the KAERI). RF power can be transferred up to 10 kW with a fixed frequency of 2 MHz through a matching circuit (auto- and manual-matching apparatus). Argon gas is commonly injected to the initial ignition of RF plasma discharge, and then hydrogen gas instead of argon gas is finally injected for the RF plasma sustainment. The uniformities of plasma density and electron temperature at the lowest area of expansion region (a distance of 300 mm from the driver region) are measured by using two electrostatic probes in the directions of short- and long-dimension of expansion region.

  • PDF

Properties of Longitudinal & Transverse Discharge in a Tubular Fluorescent Lamp (직관형 형광램프의 종단방전과 횡단방전의 특성)

  • Chung, J.Y.;Kim, J.H.;Jeong, J.M.;Jin, D.J.;Kim, H.C.;Bong, J.H.;Hwang, H.C.;Lee, M.S.;Koo, J.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.322-330
    • /
    • 2008
  • The properties of discharge, luminance, and spectroscopy are investigated in a longitudinal and transverse discharge fluorescent lamps with tube of outer diameter 4 mm. The sample lamps are prepared to be three kinds of gas composition such as mercury lamps of Ne(95%)+Ar(5%)+Hg(2 mg), the mercury-free lamps of Xe 100% and Ne+Xe(4%). The gas pressure is in the range of $5{\sim}300\;Torr$. In the mercury lamps, the longitudinal discharge having a positive column is high in luminance and efficiency, while the transverse discharge is no luminance at all. In the Xe-lamps, the transverse discharge shows relatively good in efficiency as compared with the longitudinal discharge which has a high discharge voltage and a low luminance and efficiency. In the transverse discharge of relatively high efficiency, a pure Xe(100%) gas discharge has a higher efficiency than the mixture gas of Ne+Xe(4%). Through these experiments, the properties of mercury and xenon lamps are verified. In the mercury lamps, the longitudinal discharge of tubular fluorescent lamps is high in luminance and efficiency, while the transverse discharge of flat panel fluorescent lamps are low in luminance efficiency. In the mercury-free lamps, the flat fluorescent lamps of transverse discharge having a high pressure ${\sim}100\;Torr$ with the pure Xe-gas are verified to be suggestable.

CCP에서의 마이크로 아킹 Fast-imging을 통한 마이크로 아킹 방전 메커니즘 조사

  • Kim, Yong-Hun;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.276-277
    • /
    • 2012
  • 플라즈마 아킹은 PECVD, 플라즈마 식각 그리고 토카막과 같은 플라즈마를 이용하는 여러 공정과 연구 분야에서 문제가 되어왔다. 하지만, 문제의 중요성과 다르게 아킹에 대한 본질적인 연구는 아직 미비한 상태이다. 플라즈마 아킹은 집단전자방출(collective electron emission)에 의한 스파크 방전(spark discharge) 현상이다. 집단전자방출은 전계방출(field emission)이나 플라즈마와 쉬스를 두고 인접한 표면위에서의 유전분극(dielec emission)에 의해 발생한다. 우리는 CCP 플라즈마를 이용해 micro-arcing(MA)을 일으키고 랑뮈르 프로브를 이용해 MA 동안의 플로팅 포텐셜의 변화를 측정한다. MA시 PM-tube를 이용해 광량의 변화를 측정하고 플로팅 포텐셜을 fast-imaging과 동기화 시켜 MA 발생 메커니즘을 유추한다. 우리는 $30{\times}20$ cm 크기의 사각 전극을 위 아래로 가진 챔버에서 Ar 가스를 RF (13.56 MHz) 파워를 이용해 방전시켰다. 방전 전압과 전류는 파워 전극 앞단에서 High voltage probe (Tektronix P6015A)와 Current probe (TCPA300 + TCP312)를 이용해 측정했다. 플라즈마 아킹시 변하는 플라즈마 플로팅 포텐셜은 챔버 중앙에 위치한 랑뮈프 프로브에 의해 측정되고 챔버 옆의 뷰포트 앞에 위치한 PM-tube를 이용해 아킹시 변하는 광량을 측정하고 Intensified CCD를 이용해 fast-imaging을 한다. 또한 CCD 앞에 band pass filter를 부착하여 MA의 발생 메커니즘을 유추한다. RF 방전에서의 플라즈마 아킹은 아킹시 플로팅 포텐셜의 변화에 의해 크게 세부분으로 나눌 수 있다. 아킹 발생과 동시에 급격히 감소하는 감소부분(약 2 us) 그리고 감소한 포텐셜이 유지되는 유지부분(약 0~10 ms) 그리고 감소했던 포텐셜이 서서히 원래 상태로 회복되는 회복부분(약 100 us)이다. 아킹 초기시 방출된 집단 전자들은 쉬스를 단락시키게 되고 이로 인해 플로팅 포텐셜은 급격히 감소하게 된다. 이렇게 감소한 플로팅 포텐셜은 아킹 스트리머가 유지되는 한 계속 감소한 상태를 유지하게 된다. 그리고 플라즈마를 섭동했던 집단전자방출이 중단되면 플라즈마는 섭동전의 원래 상태로 회복된다. 플라즈마 아킹 발생시 생성되는 순간적으로 많은 전자들을 국소적으로 생성하게 되고 이 전자들에 의해 광량이 순간적으로 증가하게 된다. PM-tube (750.4 nm)에 의해 측정된 아킹시 광량은 정상방전 상태의 두배 가량이 된다. 그리고 이 순간적으로 증가된 광량은 시간이 지남에 따라 감소하게 되고 정상방전 일때의 광량이 된다. 광량이 증가한 후 정상방전상태의 광량에 이르는 부분은 플로팅 포텐셜이 감소한 상태에서 유지되는 부분과 일치하고 이는 플로팅 포텐셜의 유지부분동안 집단전자방출이 있다는 간접적인 증거가 된다. 그리고 정상 방전 상태 일때의 광량이 되면 집단전자방출이 중단되었다는 것이므로 그 시점부터 플로팅 포텐셜은 정산 방전상태 일때의 포텐셜로 복구되기 시작한다. 이처럼 PM-tube를 이용한 아킹 광량 측정은 아킹 스트리머를 간접적으로 측정하게 하고 집단전자방출을 이용해 아킹 시의 플로팅 포텐셜의 변화를 설명하게 해 준다.

  • PDF

RF 플라즈마 아킹의 PM-tube를 이용한 광량 측정

  • Kim, Yong-Hun;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.125-126
    • /
    • 2010
  • 플라즈마 아킹은 PECVD, 플라즈마 식각 그리고 토카막과 같은 플라즈마를 이용하는 여러 공정과 연구 분야에서 문제점을 야기시켜왔다. 하지만, 이에 대한 연구는 아킹 현상의 불규칙성과 과도적인 행동으로 인해 미비한 상태이다. 특히, RF 방전에서의 아킹 연구는 DC 방전에서의 아킹 연구에 비해 많이 부족한 것이 현실이다. 플라즈마 아킹은 집단전자방출(collective electron emission)에 의한 스파크 방전(spark discharge)현상이다. 집단전자방출은 전계방출(field emission)이나 플라즈마와 쉬스를 두고 인접한 표면위에서의 유전분극(dielec emission)에 의해 발생한다. 이렇게 방출된 집단 전자들은 쉬스에서 가속되어 에너지를 얻게 되고 원자와의 충돌로 전자 아발란체를 일으킨다. 이렇게 배가된 전자들은 아킹 스트리머(arcing streamer)를 형성하게 되고 아킹 발생 시 높은 전류와 공정 실패의 원인이 된다. 우리는 $30cm{\times}20cm$ 크기의 사각 전극을 위 아래로 가진 챔버에서 Ar 가스를 RF(13.56 MHz)파워를 이용해 방전시켰다. 방전 전압과 전류는 파워 전극 압단에서 High voltage probe (Tektronix P6015A)와 Current probe (TCPA300 + TCP312)를 이용해 측정했다. 플라즈마 아킹시 변하는 플라즈마 플로팅 포텐셜은 챔버 중앙에 위치한 랑뮈프 프로브에 의해 측정되고 챔버 옆의 뷰포트 앞에 위치한 PM-tube를 이용해 아킹시 변하는 광량을 측정한다. RF 방전에서의 플라즈마 아킹은 아킹시 플로팅 포텐셜의 변화에 의해 크게 세부분으로 나눌 수 있다. 아킹 발생과 동시에 급격히 감소하는 감소부분 (약 2us) 그리고 감소한 포텐셜이 유지되는 유지부분 (약 0~10ms) 그리고 감소했던 포텐셜이 서서히 원래 상태로 회복되는 회복부분(약 100 us)이다. 아킹 초기시 방출된 집단 전자들과 원자들간의 충돌에 의해 형성된 아킹 스트리머는 플라즈마 전체를 단락시키게 되고 이로 인해 플로팅 포텐셜은 급격히 감소하게 된다. 이렇게 감소한 플로팅 포텐셜은 아킹 스트리머가 유지되는 한 계속 감소한 상태를 유지하게 된다. 그리고 플라즈마를 섭동했던 아킹 스트리머가 중단되면 플라즈마는 섭동전의 원래 상태로 돌아가려 하기 때문에 플로팅 포텐셜은 서서히 증가하면서 원래 상태로 회복된다. 플라즈마 아킹 발생시 생성되는 아킹 스트리머는 순간적으로 많은 전자들을 국소적으로 생성하게 되고 이 전자들에 의해 광량이 순간적으로 증가하게 된다. PM-tube (750.4 nm)에 의해 측정된 아킹시 광량은 정상방전 상태의 두배 가량이 된다. 그리고 이 순간적으로 증가된 광량은 시간이 지남에 따라 감소하게 되고 정상방전 일때의 광량이 된다. 광량이 증가한 후 정상방전 상태의 광량에 이르는 부분은 플로팅 포텐셜이 감소한 상태에서 유지되는 부분과 일치하고 이는 플로팅 포텐셜의 유지부분동안 아킹 스트리머가 발생하고 있다는 간접적인 증거가 된다. 그리고 정상 방전 상태 일때의 광량이 되면 아킹 스트리머가 중단되었다는 것이므로 그 시점부터 플로팅 포텐셜은 정산 방전상태 일 때의 포텐셜로 복구되기 시작한다. 이처럼 PM-tube를 이용한 아킹 광량 측정은 아킹 스트리머를 간접적으로 측정하게 하고 아킹 스트리머를 이용해 아킹시의 플로팅 포텐셜의 변화를 설명하게 해 준다. 응용적인 측면에서 아킹 광량 측정을 이용한 아킹 판독은 방전 전류와 방전 전압과 같은 전기적 신호를 이용한 아킹 판독에 비해 여러가지 장점을 가진다. 우선, 전기적 신호를 이용한 아킹 판독처럼 매칭 회로나 플라즈마를 섭동시키지 않는다. 그리고 원하는 부분의 아킹만을 판독하는 것도 가능하며 photo-diode를 이용할 경우 전기적 신호를 이용하는 것에 비해 경제적으로 유리하다.

  • PDF

Measurement of Electron Temperature and Number Density and Their Effects on Reactive Species Formation in a DC Underwater Capillary Discharge

  • Ahmed, Muhammad Waqar;Rahman, Md. Shahinur;Choi, Sooseok;Shaislamov, Ulugbek;Yang, Jong-Keun;Suresh, Rai;Lee, Heon-Ju
    • Applied Science and Convergence Technology
    • /
    • v.26 no.5
    • /
    • pp.118-128
    • /
    • 2017
  • The scope of this work is to determine and compare the effect of electron temperature ($T_e$) and number density ($N_e$) on the yield rate and concentration of reactive chemical species ($^{\bullet}OH$, $H_2O_2$ and $O_3$) in an argon, air and oxygen injected negative DC (0-4 kV) capillary discharge with water flow(0.1 L/min). The discharge was created between tungsten pin-to pin electrodes (${\Phi}=0.5mm$) separated by a variable distance (1-2 mm) in a quartz capillary tube (2 mm inner diameter, 4 mm outer diameter), with various gas injection rates (100-800 sccm). Optical emission spectroscopy (OES) of the hydrogen Balmer lines was carried out to investigate the line shapes and intensities as functions of the discharge parameters such as the type of gas, gas injection rate and inter electrode gap distances. The intensity ratio method was used to calculate $T_e$ and Stark broadening of Balmer ${\beta}$ lines was adopted to determine $N_e$. The effects of $T_e$ and $N_e$ on the reactive chemical species formation were evaluated and presented. The enhancement in yield rate of reactive chemical species was revealed at the higher electron temperature, higher gas injection rates, higher discharge power and larger inter-electrode gap. The discharge with oxygen injection was the most effective one for increasing the reactive chemical species concentration. The formation of reactive chemical species was shown more directly related to $T_e$ than $N_e$ in a flowing water gas injected negative DC capillary discharge.

Mercury Quantity in a Fluorescent Lamp for a Backlight of LCD-TVs (LCD-백라이트용 형광램프의 수은량)

  • Bong, Jae-Hwan;Kim, Yun-Jung;Hwang, Ha-Chung;Jin, Dong-Jun;Jeong, Jong-Mun;Kim, Jung-Hyun;Koo, Je-Huan;Cho, Guang-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.495-500
    • /
    • 2008
  • The amount of vapor mercury for the generation of glow discharge plasma has been calculated in a fine tube fluorescent lamp having a mixed gas of Ne+Ar including a mercury. When the ionization of atom is considered by the collision between neutral atoms (Ne, Ar, Hg) and electrons of energy $kT_e{\sim}1\;eV$, the density of vapor mercury atom has been obtained as $n(Hg){\sim}3.43{\times}10^{22}m^{-3}$ for the plasma density $n_o{\sim}10^{17}m^{-3}$. In the fluorescent lamps of out diameter 4 mm used for $32{\sim}42$-inch LCD-TVs having a mixture gas of Ne(95%)+Ar(5%) with the pressure of 50 Torr, the quantity of vapor mercury for the glow discharge has been caculated as 0.02{\sim}0.08\;mg$.

Fabrication and Property of Excimer Lamp Coated with Green-emitting Zn2SiO4:Mn2+ Phosphor Film (녹색발광 Zn2SiO4:Mn2+ 형광체가 코팅된 엑시머 램프의 제작 및 특성)

  • Kang, Busic;Jung, Hyunjee;Jeong, Yongseok;Son, Semo;Kim, Jongsu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.4
    • /
    • pp.106-109
    • /
    • 2022
  • The green-emitting Zn2SiO4:Mn2+ phosphor film was evaluated in a xenon excimer lamp. The phosphor film with 2 ㎛ thick was formed of monolithic structure on the inner side of quartz through a long-time annealing process of coated ZnO solution doped with Mn2+ ion and SiO2 of quartz tube. The coated quartz was filled with 100 torr of xenon gas, and simultaneously both sides was melt and sealed. The xenon-field quartz tube was discharge by applying the voltage of 15 kV with a frequency of 26 kHz, and emitted the glow with dominant peak at 172 nm. The vacuum ultraviolet excited the inner-side coated Zn2SiO4:Mn2+ phosphor film, which emitted the pure and strong green light.

Observation of Light-Propagation along the Tube of Cold Cathode Fluorescent Lamp (냉음극 형광램프의 광 전파)

  • Cho, Y.H.;Jin, D.J.;Kim, J.H.;Han, S.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.114-126
    • /
    • 2011
  • The light propagation along a long positive column has been observed in a cold cathode fluorescent lamp. The optical signals are observed with the DC and AC voltage power during lamp operation. The light propagating is observed in the operation with the DC-rippled voltage as well as the AC-voltage. The optical signals propagate from the high voltage side to the ground. These signals show two kinds of features according to the before and after Townsend breakdown. At the dark current before Townsend breakdown, the optical intensity is damped and the propagation velocity is $10^4{\sim}10^5m/s$. At the high current of normal glow after Townsend breakdown, the propagation velocity is 1$10^5{\sim}10^6m/s$ without damping.

Optical Diagnostics for Pulse-discharged Plasma by Marx Generator and Its Application for Modifications of Hemoglobin and Myoglobin Proteins

  • Park, Ji Hoon;Attri, Pankaj;Hong, Young June;Park, Bong Sang;Jeon, Su Nam;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.176.2-176.2
    • /
    • 2013
  • Property of optical diagnostics for pulse-discharged plasma in liquid and its biological applications to proteins are investigated by making use of high voltage Marx generator. The Marx generator has been consisted of 5 stages, where each charging capacitor is 0.5 ${\mu}F$, to generate a high voltage pulse with rising time of $1{\mu}s$. We have applied an input voltage of 6 kV to the each capacitor of 0.5 ${\mu}F$. High voltage pulsed plasma has been generated inside a polycarbonate tube by a single-shot operation, where the breakdown voltage is measured to be 7 kV, current of 1.2 kA, and pulse width of ~ 1 ${\mu}s$ between the two electrodes of anode-cathode whose material is made of tungsten pin, which are immersed into the liquids. We have investigated the emitted hydrogen lines for optical diagnostics of high voltage pulsed plasma. The emission line of 656.3 nm from $H-{\alpha}$ and 486.1 nm from $H-{\beta}$ have been measured by a monochromator. If we assumed that the focused plasma regions satisfy the local thermodynamic equilibrium conditions, the electron temperature and density of the high voltage pulsed plasma in liquid could be obtained by the Stark broadening of optical emission spectroscopy. For the investigation of the influence of pulsed plasma on biological proteins, we have exposed it onto the proteins such as hemoglobin and myoglobin. The structural changes in these proteins and their analysis have also been obtained by circular dichroism (CD) and ultraviolet (UV) visible spectroscopy.

  • PDF

Development of 80 kW RF Thermal Plasma Torch System for Mass Production and Research of Si Nano-Powder Manufacturing Process (양산용 80 kW급 RF Plasma Torch System 개발 및 Si 나노분말 제조 공정 연구)

  • Song, Seok-Kyun;Son, Byungkoo;Kim, Byunghoon;Lee, Moonwon;Sin, Myungsun;Choi, Sunyong;Lee, Kyu-Hang;Kim, Seong-In
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.2
    • /
    • pp.66-78
    • /
    • 2013
  • In order to develop of 80 kW RF plasma torch system, we achieved three-dimensional simulations for the extraction of more information as temperature in torch and fluid behavior analysis, etc. The position of powder injection tube, the plasma discharge characteristics with various input current and various length of ceramic tube, and the plasma temperature characteristics with process gas flow rate such those was simulated. RF thermal plasma torch designed by simulation was manufactured that was measured to the maximum of 89.3 kW power. The mass production using developed 80 kW RF thermal plasma torch system were investigated by characteristics manufactured of Si nano powder. The mass-production level of Si nano-powder was average of 539 g/hr and high yield rate of 71.6%, respectively. The particle size distribution $D_{99}/D_{50}$ of manufacturing nano-powder was investigated to 1.98 as a good uniform.