• Title/Summary/Keyword: Vacuum Vessel

Search Result 88, Processing Time 0.028 seconds

Commissioning result of the KSTAR in-vessel cryo-pump

  • Chang, Y.B.;Lee, H.J.;Park, Y.M.;Lee, Y.J.;Kwag, S.W.;Song, N.H.;Park, D.S.;Joo, J.J.;Moon, K.M.;Kim, N.W.;Yang, H.L.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.53-58
    • /
    • 2013
  • KSTAR in-vessel cryo-pump has been installed in the vacuum vessel top and bottom side with up-down symmetry for the better plasma density control in the D-shape H-mode. The cryogenic helium lines of the in-vessel cryo-pump are located at the vertical positions from the vacuum vessel torus center 2,000 mm. The inductive electrical potential has been optimized to reduce risk of electrical breakdown during plasma disruption. In-vessel cryo-pump consists of three parts of coaxial circular shape components; cryo-panel, thermal shield and particle shield. The cryo-panel is cooled down to below 4.5 K. The cryo-panel and thermal shields were made by Inconel 625 tube for higher mechanical strength. The thermal shields and their cooling tubes were annealed in air environment to improve the thermal radiation emissivity on the surface. Surface of cryo-panel was electro-polished to minimize the thermal radiation heat load. The in-vessel cryo-pump was pre-assembled on a test bed in 180 degree segment base. The leak test was carried out after the thermal shock between room temperature to $LN_2$ one before installing them into vacuum vessel. Two segments were welded together in the vacuum vessel and final leak test was performed after the thermal shock. Commissioning of the in-vessel cryo-pump was carried out using a temporary liquid helium supply system.

Development of the Welded Bellows for KSTAR Vacuum Vessel (KSTAR 진공용기용 용접 Bellows 개발)

  • Her, N.I.;Kim, B.C.;Kim, G.H.;Hong, G.H.;Sa, J.W.;Kim, H.K.;Kim, K.M.;Bak, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1098-1102
    • /
    • 2003
  • Vacuum vessel of the KSTAR(Korea Superconducting Tokamak Advanced Research) tokamak is a fully welded structure with D-shaped cross-section. According to the requirements of the physics design, sixteen horizontal ports, sixteen slanted ports, sixteen baking and cooling ports, and twenty-four top and bottom vertical ports are designed for the diagnostics, plasma heating, vacuum pumping, and baking and cooling. Bellows on these ports are used for flexible components to absorb the relative displacement due to the vacuum vessel thermal expansion and the electromagnetic force between the vacuum vessel and the cryostat ports. Fatigue strength evaluation was performed to decide the dimension of the bellows. In order to assure the quality of the bellows, a prototype bellows for the neutral beam injection port has been fabricated and tested prior to main fabrication. It was conformed that the prototype bellows has sufficient fatigue strength and vacuum reliability in the expected load conditions.

  • PDF

Baking analysis of the KSTAR vacuum vessel and plasma facing components (KSTAR 진공용기 및 플라즈마 대향 부품에 대한 베이킹 해석)

  • 이강희;임기학;허남일;인상렬;조승연
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4A
    • /
    • pp.397-402
    • /
    • 1999
  • The base pressure of the vacuum vessel of KSTAR tokamak is to be ultra high vacuum, $10^{-6}\sim10^{-7}Pa$, to produce a clean plasma with low impurity concentrations. For this purpose, vessel and plasma facing components need to be baked up to $250^{\circ}C$, $350^{\circ}C$ respectively to remove impurities from the plasma-material interaction surfaces. Here the required heating power to be supplied for baking has been calculated according to pre-assumed different temperature profiles (baking scenario and proper baking plan for KSTAR tokamak has been proposed. Mass flow rate and temperature of nitrogen gas for baking has also been calculated.

  • PDF

Vacuum properties of CFC (carbon fiber composits) (탄소섬유복합재(CFC)의 진공특성)

  • 인상렬;박미영
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4B
    • /
    • pp.497-506
    • /
    • 1999
  • Carbon has been widely used for the material of plasma facing components in fusion experiment devices like a tokamak, because carbon has good thermal and mechanical properties. However carbon gas a relatively high ougassing rate. Therefore the amount and the surface area of the carbon material used in the vessel will determine the background pressure of the vacuum vessel. In this experiment influences of carbon on the vacuum performance was investigated by measuring chamber pressure, ougassing rater and gas spectrum of carbon fiber composite (CFC) samples in various situations, pumping out, chamber baking, carbon heating (250~$500^{\circ}C$), exposure to atmosphere for maintenance of in-vessel components, etc., occurring routinely during tokamak operations.

  • PDF

The KSTAR Vacuum Pumping and Fueling System Upgrade

  • Lim, J.Y.;Chung, K.H.;Cho, S.Y.;Lee, S.K.;Shin, Y.H.;Hong, S.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.39-39
    • /
    • 1999
  • The KSTAR (Korea Superconducting Tokamak Advanced Research) tokamak is a nuclear fusion experimental device for a long pulse/steady-state plasma operation, adopting fully superconducting magnets. In accordance with completion of the basic design of the torus vacuum vessel and the enclosing cryostat, the vacuum pumping and gas fueling basic design has been developed to fulfil the physics requirements. The ultra-high vacuum pumping and sophisticated gas fueling system of the machine is essential to achieve such roles for optimized plasma performance and operation. Recently the vacuum exhaust system using dedicated pumping ports for the vacuum vessel and cryostat has been modified to meet more reliable and successful performance of the KSTAR[Fig. 1].In order to achieve the required base pressure of 5 x 10-9 torr, the total impurity load to the vessel internal is limited to ~5 x 10-5 torr-1/x, while the cryostat base pressure is kept as ~5 x 105 torr to mitigate the thermal load applied to the superconducting magnets. Each KSTAR fueling system will be separately capable of fueling gas at a rate of 50 torr-1/x, consistent with the given pumping throughput. In order to initiate a plasma discharge in KSTAR, the vacuum vessel is filled to a gas pressure of few 10-6 to few 10-4 torr, and additional gas injection is required to maintain and increase the plasma density during the course of the discharge period.

  • PDF

Effects of Additional Bubbling on RH Vacuum Degassing Process with Water Model Experiment (수모델을 사용한 RH 진공 탈가스장치에서의 추가 버블링 효과)

  • Jang, Young-Hwan;Kim, Young-Tae;Yi, Kyung-Woo
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.5
    • /
    • pp.424-429
    • /
    • 2010
  • In the RH process, it is possible to obtain quicker processing times by enhancing the decarburization rates at a low carbon range of steel melt through Ar gas injection into the vacuum vessel. The RH decarburization reaction was simulated through a dissolved oxygen removal reaction by injecting nitrogen into a 1/8 scale RH water model system. The gas nozzles for the N$_{2}$ injection into the vacuum vessel were located at the lowest level of the vessel's outer wall. The nitrogen bubbling in the vacuum vessel resulted in an increase in the reaction rate constant, which rose in accordance with an increase in the bubbling flow rate and number of nozzles used. However, there was almost no variation in the reaction rate constant, which depended on the horizontal positions of the bubbling nozzles.

A Study on Temperature Characteristics of KSTAR PFC and Vacuum Vessel at Baking Phase (KSTAR PFC와 진공용기의 가열탈리 단계에서의 온도특성에 관한 연구)

  • Yoo, Seong-Yeon;Kim, Young-Jin;Jung, Nam-Yong;Kim, Kyung-Min;Lee, Je-Myo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.3
    • /
    • pp.158-168
    • /
    • 2015
  • To create an ultra-high vacuum state at the KSTAR, the temperature of plasma facing component and vacuum vessel should be maintained at $300^{\circ}C$ and $110^{\circ}C$ respectively at a baking phase. The purpose of this research is obtaining the target baking temperatures. Experiments were performed to investigate the temperature characteristics of PFC and VV at the baking phase. Thermal network analysis was used to find heat transfer rates among PFC, VV and other components, and this analysis was verified by using the experimental data. The required heating energy of the PFC and the heating and cooling energy of the VV for the target baking temperatures were found to be 346 kW, 28 kW, and 136 kW, respectively.

A Structural Analysis of the KSTAR Cryostat (KSTAR 저온진공용기 구조해석)

  • 허남일;김형섭;조승연;임기학;KSTAR설계팀
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.185-188
    • /
    • 1999
  • KSTAR cryostat is a large vacuum vessel that provides the necessary thermal barrier between the ambient temperature test cell and the liquid helium cooled magnets. In this work, the structural analyses for the cryostat under the normal operation condition were performed. As a result, it turns out that the vessel would be safe when it is exposed to normal operation loads, such as system weight, vacuum pressure, and plasma vertical disruption load. And, the preliminary result on the modal analysis is presented.

  • PDF

Performance experiment of a hydrogen liquefaction equipment by direct cooling (직접냉각에 의한 수소액화장치의 성능실험)

  • Baik, J.H.;Kang, B.H.;Chang, H.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.284-291
    • /
    • 1997
  • A hydrogen liquefaction equipment by direct cooling has been designed and built at KIST. Cool-down characteristics and liquefaction performance of the equipment have been investigated. The hydrogen liquefaction equipment consists of a GM refrigerator, a liquefaction velssel, a radiation shield and a cryostat. It is found that the hydrogen starts to be liquefied in the liquefaction vessel after 40~50 minutes of cool-down from the gas state of 270K. The effect of natural convection phenomena of charged gas in liquefaction vessel on the cool-down characteristics is evaluated by comparing with those in vacuum of liquefaction vessel. It is seen that the cool-down time of a liquefaction vessel is substantially increased in vacuum environment of liquefaction vessel. The experiments have been performed for 1~5 atm of hydrogen pressure to investigate the influence of hydrogen pressure on the liquefaction rate and figure of merit(FOM). It is found that both liquefaction rate and FOM are increased as the charged hydrogen pressure is increased.

  • PDF