• Title/Summary/Keyword: VS reduction

Search Result 491, Processing Time 0.028 seconds

Comparison of Intraoperative Somatosensory Evoked Potential(SSEP) Monitoring During Aneurysm Surgery : ACA Aneurysms vs MCA Aneurysms (전대뇌동맥과 중대뇌동맥 동맥류 수술시 체성감각유발전위의 모니터링의 비교, 분석)

  • Choi, Kwang Yeong;Kim, Gook Ki;Lim, Young Jin;Kim, Tae Sung;Leem, Won;Rhee, Bong Arm
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.281-288
    • /
    • 2001
  • Objectives : The purpose of this study is to evaluate the usefulness of SSEP monitoring during intracranial aneurysm surgery and compare the characteristics of wave change in relation to neurologic changes between ACA aneurysms and MCA aneurysms. Methods : During recent three years(between January 1997 and November 1999), intraoperative SSEP monitoring had been done in 63 operations for intracranial aneurysms. We had monitored the median nerve SSEP during surgery for aneurysms of MCA and the posterior tibial nerve SSEP for aneurysms of ACoA or ACA. A more than 50% reduction of any cortical SEP response was considered to be a significant SEP change, compared to its baseline value before the start of surgery. Changes in the SEPs were categorized as follows : Type IA, no significant amplitude changes without temporary clipping ; Type IB, no significant amplitude changes with temporary clipping ; Type II, significant changes with temporary clipping and complete return to control amplitude ; Type III, significant changes with temporary clipping and incomplete return to control amplitude ; Type IV, significant changes with temporary clipping and more decreased amplitude changes. Results : Among the 63 intraoperative monitoring, there were 37 cases of ACA aneurysms(An), and 26 of MCA An. The temporary proximal arterial occlusion during surgery were performed in 31(83.8%)cases of ACA An, 22(84.6%) of MCA An. Seven of the 31 ACA An(22.6%) and ten of the 22 MCA An(45.5%) had significant changes. The type were as follows : 4 patients with type II and 3 with type III in the ACA An ; 3 patients with type II and 3 with type III and 4 with type IV in the MCA An. In both group type II changes had no new postoperative neurological deficit. All 6 patients with type III had new neurological deficits ; However, One case in the ACA An and two cases in the MCA An. had transient neurologic deficit and improved markedly over the next two months. All 4 type IV changes in the MCA An. had permanant neurologic deficits. Two out of 30 cases(6.7%) in the ACA An. and one out of 16 cases(6.3%) in the MCA An. without significant amplitude change had new neurologic deficit postoperatively. Conclusion : Based on this study, Intraoperative SSEP monitoring during aneurysm surgery would provide useful information for detecting cerebral ischemia. SSEP response during surgery for MCA An. is more sensitive than ACA An. Otherwise, there were no meaningful difference in rate of false negativity.

  • PDF

Synthesis of Binuclear Bismacrocyclic Iron(II) Complex by the Aerobic Oxidation of Iron(II) Complex of 1,4,8,11-Tetraazacyclotetradecane

  • Myunghyun Paik Suh;Gee-Yeon Kong;Il-Soon Kim
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.4
    • /
    • pp.439-444
    • /
    • 1993
  • The aerobic oxidation of the Fe(II) complex of 1,4,8,11-tetraazacyclotetradecane, [Fe(cyclam)$(CH_3CN)_2](ClO_4)_2$, in MeCN in the presence of a few drops of $HClO_4$ leads to low spin Fe(III) species [Fe(cyclam)$(CH_3CN)_2](ClO_4)_3$. The Fe(III) cyclam complex is further oxidized in the air in the presence of a trace of water to produce the deep green binuclear bismacrocyclic Fe(II) complex $[Fe_2(C_{20}H_{36}N_8)(CH_3CN)_4](ClO_4)_4{\cdot}2CH_3CN$. The Fe(II) ions of the complex are six-coordinated and the bismacrocyclic ligand is extensively unsaturated. $[Fe_2(C_{20}H_{36}N_8)(CH_3CN)_4](ClO_4)_4{\cdot}2CH_3CN$ crystallizes in the monoclinic space group $P2_1/n$ with a= 13.099 (1) ${\AA}$, b= 10.930 (1) ${\AA}$, c= 17.859 (1) ${\AA}$, ${\beta}$= 95.315 $(7)^{\circ}$, and Z= 2. The structure was solved by heavy atom methods and refined anisotropically to R values of R= 0.0633 and $R_w$= 0.0702 for 1819 observed reflections with F > $4{\sigma}$ (F) measured with Mo K${\alpha}$ radiation on a CAD-4 diffractometer. The two macrocyclic units are coupled through the bridgehead carbons of ${\beta}$-diimitie moieties by a double bond. The double bonds in each macrocycle unit are localized. The average bond distances of $Fe(II)-N_{imine}$, $Fe(II)-N_{amine}$, and $Fe(II)-N_{MeCN}$ are 1.890 (5), 2.001 (5), and 1.925 (6) ${\AA}$, respectively. The complex is diamagnetic, containing two low spin Fe(II) ions in the molecule. The complex shows extremely intense charge transfer band in the near infrared at 868 nm with ${\varepsilon}$= 25,000 $M^{-1}cm^{-1}$. The complex shows a one-electron oxidation wave at +0.83 volts and two one-electron reduction waves at -0.43 and-0.72 volts vs. Ag/AgCl reference electrode. The complex reacts with carbon monoxide in $MeNO_2$ to form carbonyl adducts, whose $v_{CO}$ value (2010 $cm^{-1}$) indicates the ${\pi}$-accepting property of the present bismacrocyclic ligand.

Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial for Comparison with Conventional CT Urography

  • Kim, Sang Youn;Cho, Jeong Yeon;Lee, Joongyub;Hwang, Sung Il;Moon, Min Hoan;Lee, Eun Ju;Hong, Seong Sook;Kim, Chan Kyo;Kim, Kyeong Ah;Park, Sung Bin;Sung, Deuk Jae;Kim, Yongsoo;Kim, You Me;Jung, Sung Il;Rha, Sung Eun;Kim, Dong Won;Lee, Hyun;Shim, Youngsup;Hwang, Inpyeong;Woo, Sungmin;Choi, Hyuck Jae
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1119-1129
    • /
    • 2018
  • Objective: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. Materials and Methods: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. Results: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose ($5.73{\pm}4.04$ vs. $8.43{\pm}4.38mSv$) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score ${\geq}3$), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. Conclusion: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced.

Seismic investigation of cyclic pushover method for regular reinforced concrete bridge

  • Shafigh, Afshin;Ahmadi, Hamid Reza;Bayat, Mahmoud
    • Structural Engineering and Mechanics
    • /
    • v.78 no.1
    • /
    • pp.41-52
    • /
    • 2021
  • Inelastic static pushover analysis has been used in the academic-research widely for seismic analysis of structures. Nowadays, the variety pushover analysis methods have been developed, including Modal pushover, Adaptive pushover, and Cyclic pushover, in which some weaknesses of the conventional pushover method have been rectified. In the conventional pushover analysis method, the effects of cumulative growth of cracks are not considered on the reduction of strength and stiffness of RC members that occur during earthquake or cyclic loading. Therefore, the Cyclic Pushover Analysis Method (CPA) has been proposed. This method is a powerful technique for seismic evaluation of regular reinforced concrete buildings in which the first mode of them is dominant. Since the bridges have different structures than buildings, their results cannot necessarily be attributed to bridges, and more research is needed. In this study, a cyclic pushover analysis with four loading protocols (suggested by valid references) by the Opensees software was conducted for seismic evaluation of two regular reinforce concrete bridges. The modeling method was validated with the comparison of the analytical and experimental results under both cyclic and dynamic loading. The failure mode of the piers was considered in two-mode of flexural failure and also a flexural-shear failure. Along with the cyclic analysis, conventional analysis has been studied. Also, the nonlinear incremental dynamic analysis (IDA) method has been used to examine and compare the results of pushover analyses. The time history of 20 far-field earthquake records was used to conduct IDA. After analysis, the base shear vs. displacement in the middle of the deck was drawn. The obtained results show that the cyclic pushover analysis method is able to evaluate an accurate seismic behavior of the reinforced concrete piers of the bridges. Based on the results, the cyclic pushover has proper convergence with IDA. Its accuracy was much higher than the conventional pushover, in which the bridge piers failed in flexural-shear mode. But, in the flexural failure mode, the results of each two pushover methods were close approximately. Besides, the cyclic pushover method with ACI loading protocol, and ATC-24 loading protocol, can provided more accurate results for evaluating the seismic investigation of the bridges, specially if the bridge piers are failed in flexural-shear failure mode.

Neuroprotective effect of Puerariae Radix extract on focal cerebral ischemia in mice (갈근 에탄올추출물의 국소뇌허혈 모델에 대한 뇌신경보호 효과)

  • Song, Jungbin;Choi, Jin Gyu;Lee, Donghung;Gaire, Bhakta Prasad;Lee, Changwon;Bu, Youngmin;Choi, Ho-Young;Kim, Hocheol
    • The Korea Journal of Herbology
    • /
    • v.27 no.6
    • /
    • pp.71-76
    • /
    • 2012
  • Objectives : The purpose of this study was to evaluate the neuroprotective effect of Pueraria lobata extract on focal cerebral ischemia in mice. Methods : Focal cerebral ischemia was induced by occlusion of the right middle cerebral artery using the intraluminal filament model. ICR male mice underwent 90 minutes of middle cerebral artery occlusion (MCAo) followed by 24 hours of reperfusion. Mice were administered Pueraria lobata extract orally at the dose of 300mg/kg just prior to reperfusion. Rotarod test and balance beam test were practiced to assess sensory-motor function 23 hours after MCAo. In rotarod test, the latency to fall on the accelerating rotarod was recorded for 5 min. In balance beam test, the score was graded according to number of slips and latency to cross. The infarct volume was measured 24 hours after MCAo using 2% 2,3,5-triphenyltetrazolium chloride (TTC) staining. Results : Pueraria lobata extract treated group showed significant reduction in infarct volume by 27.3% compared to control group (p<0.05). In rotatod test, it also showed significant extension of latency time compared to control group ($67.82{\pm}15.08$ vs. $5.62{\pm}1.06$, p<0.001). In contrast to performance in rotarod test, that in balance beam test did not improve with Pueraria lobata extract treatment. Conclusions : We conclude that Pueraria lobata extract has a significant neuroprotective effect and reduces damage of sensory-motor function in MCAo model. These findings suggest that Pueraria lobata could be a potent neuroprotective agent.

A Review on the Deposition/Dissolution of Lithium Metal Anodes through Analyzing Overpotential Behaviors (과전압 거동 분석을 통한 리튬 금속 음극의 전착/탈리 현상 이해)

  • Han, Jiwon;Jin, Dahee;Kim, Suhwan;Lee, Yong Min
    • Journal of the Korean Electrochemical Society
    • /
    • v.25 no.1
    • /
    • pp.1-12
    • /
    • 2022
  • Lithium metal is the most promising anode for next-generation lithium-ion batteries due to its lowest reduction potential (-3.04 V vs. SHE) and high specific capacity (3860 mAh/g). However, the dendritic formation under high charging current density remains one of main technical barriers to be used for commercial rechargeable batteries. To address these issues, tremendous research to suppress lithium dendrite formation have been conducted through new electrolyte formulation, robust protection layer, shape-controlled lithium metal, separator modification, etc. However, Li/Li symmetric cell test is always a starting or essential step to demonstrate better lithium dendrite formation behavior with lower overpotential and longer cycle life without careful analysis. Thus, this review summarizes overpotential behaviors of Li/Li symmetric cells along with theoretical explanations like initial peaking or later arcing. Also, we categorize various overpotential data depending on research approaches and discuss them based on peaking and arcing behaviors. Thus, this review will be very helpful for researchers in lithium metal to analyze their overpotential behaviors.

Determination of Mode Dispersion Curves of Surface Wave Using HWAW Method (HWAW(Harmonic Wavelet Analysis of Wave)방법을 이용한 표면파 모드 분산곡선의 결정)

  • Park, Hyung-Choon;Kim, Dong-Soo;Bang, Eun-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.12
    • /
    • pp.15-24
    • /
    • 2006
  • The evaluation of shear modulus is very important in various fields of civil engineering. Non-destructive seismic methods can be used to determine shear wave velocity ($V_s$) profile. Non-destructive seismic methods geneally consist of three steps: field testing, evaluation of dispersion curve, and determination of Vs profile by inversion process. Non-destructive seismic methods can be divided into two categories according to the number of receivers used for data reduction: two-channel tests and multi-channel tests. Two channel tests use apparent velocity dispersion curve and multi-channel tests use mode dispersion curves. Multi-channel tests using mode dispersion curve can reduce calculation time to determine soil profile and uncertainties in inversion process. So far, only multi-channel tests can determine mode dispersion curves but multi-channel test needs many receivers to determine reasonable mode dispersion curves. In this paper, HWAW (Harmonic Wavelet Analysis of Wave) method is applied to determine mode dispersion curves. HWAW method uses short test setup which consists of two receivers with a spacing of 1 to 3 m. Through numerical simulations and field application, it is shown that HWAW can determine resonable mode disperson curves.

Accuracy of Astigmatic Correction Using Toric Intraocular Lens by Position and Size of Corneal Incision (각막절개 위치와 크기에 따른 난시교정인공수정체의 난시교정의 정확성)

  • Park, Wookyung;Kim, Man Soo;Kim, Eun Chul
    • Journal of The Korean Ophthalmological Society
    • /
    • v.60 no.2
    • /
    • pp.126-134
    • /
    • 2019
  • Purpose: To assess the accuracy of toric intraocular lens (IOL) implantation by the location and size of the corneal incision. Methods: We retrospectively reviewed the medical records of 98 patients (98 eyes) who underwent phacoemulsification with toric IOL implantation from January 2014 to March 2017. The patients were divided into two groups: group 1 got an incision of the superior side of the cornea (n = 54) and group 2 received an incision on the temporal side of the eye (n = 44). For both groups, incisions were made at their steep corneal astigmatism axises. Each group was further divided into subgroups for whom different sized blades were employed (2.75 vs. 2.2 mm widths). We measured the refractive index and autokeratometric parameters. We postoperatively assessed residual astigmatism and any reduction thereof. Results: In both groups, uncorrected and best-corrected visual acuity, refraction cylinder astigmatism, and autokeratometric astigmatism improved statistically. Between two groups, corneal astigmatism decrease was not significant. Residual astigmatism also showed no significant differences between the two. Patients in both groups treated using 2.75 mm wide blades exhibited greater increases in corneal astigmatism. Conclusions: During cataract surgery, precise correction of astigmatism via toric IOL implantation is possible when surgically induced astigmatism is minimized by careful choice of the location and size of the corneal incision.

Effects of Operation Parameters on Pollutants Removal in a Lab-Scale Multi-Layered Soil Filtration System (하천 수질정화를 위한 실험실 규모 다단식 토양여과 시스템에서 오염물질 제거에 미치는 운전인자의 영향)

  • Won, Se-Yeon;Ki, Dong-Won;Yoon, Min-Hyeok;Maeng, Sung-Kyu;Ahn, Kyu-Hong;Park, Joon-Hong;Song, Kyung-Guen
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.2
    • /
    • pp.91-96
    • /
    • 2012
  • In this study we investigated the effects of operational parameters of a multi-layered soil filtration (filter depth, filtration velocity, and continuous/intermittent operation) on removal of pollutants in river water. As filter depth increased removal of all the pollutants (COD, TP, TN, and $NH_4$-N) was increased because the increase in filter depth increased in contact time between media and pollutants. The removal of TP and $NH_4$-N more increased with the increase in filter depth, comparing to the biological COD removal which was performed only in the top layer, since the removal mechanism of TP and $NH_4$-N was physicochemical process occurring throughout the whole layers. However, the reduction in filtration velocity resulted in decrease of removal all the pollutants removal due to shorter retention time. Biological COD removal was more influenced with the reduction in filtration velocity (longer retention time), than the removal of TP and $NH_4$-N. Because biological process was occurred only in the top layer which has relatively shorter retention time, comparing with physicochemical process occurred throughout whole media. Therefore, it is desirable that the operation parameters be controlled toward increasing retention time, in order to achieve efficient pollutants removal. The change in operation mode (continuos vs. intermittent operations) did not provide significant effects on the pollutant treatment efficiency by the multi-layered soil filtration system. Our findings suggest that for stable long-term operation it should be considered keeping conditions for biological activity and accelerating clogging.

Nutritional and Tissue Specificity of IGF-I and IGFBP-2 Gene Expression in Growing Chickens - A Review -

  • Kita, K.;Nagao, K.;Okumura, J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.5
    • /
    • pp.747-754
    • /
    • 2005
  • Nutritional regulation of gene expression associated with growth and feeding behavior in avian species can become an important technique to improve poultry production according to the supply of nutrients in the diet. Insulin-like growth factor-I (IGF-I) found in chickens has been characterized to be a 70 amino acid polypeptide and plays an important role in growth and metabolism. Although it is been well known that IGF-I is highly associated with embryonic development and post-hatching growth, changes in the distribution of IGF-I gene expression throughout early- to late-embryogenesis have not been studied so far. We revealed that the developmental pattern of IGF-I gene expression during embryogenesis differed among various tissues. No bands of IGF-I mRNA were detected in embryonic liver at 7 days of incubation, and thereafter the amount of hepatic IGF-I mRNA was increased from 14 to 20 days of incubation. In eyes, a peak in IGF-I mRNA levels occurred at mid-embryogenesis, but by contrast, IGF-I mRNA was barely detectable in the heart throughout all incubation periods. In the muscle, no significant difference in IGF-I gene expression was observed during different stages of embryogenesis. After hatching, hepatic IGF-I gene expression as well as plasma IGF-I concentration increases rapidly with age, reaches a peak before sexual maturity, and then declines. The IGF-I gene expression is very sensitive to changes in nutritional conditions. Food-restriction and fasting decreased hepatic IGF-I gene expression and refeeding restored IGF-I gene expression to the level of fed chickens. Dietary protein is also a very strong factor in changing hepatic IGF-I gene expression. Refeeding with dietary protein alone successfully restored hepatic IGF-I gene expression of fasted chickens to the level of fed controls. In most circumstances, IGF-I makes a complex with specific high-affinity IGF-binding proteins (IGFBPs). So far, four different IGFBPs have been identified in avian species and the major IGFBP in chicken plasma has been reported to be IGFBP-2. We studied the relationship between nutritional status and IGFBP-2 gene expression in various tissues of young chickens. In the liver of fed chickens, almost no IGFBP-2 mRNA was detected. However, fasting markedly increased hepatic IGFBP-2 gene expression, and the level was reduced after refeeding. In the gizzard of well-fed young chickens, IGFBP-2 gene expression was detected and fasting significantly elevated gizzard IGFBP-2 mRNA levels to about double that of fed controls. After refeeding, gizzard IGFBP-2 gene expression decreased similar to hepatic IGFBP-2 gene expression. In the brain, IGFBP-2 mRNA was observed in fed chickens and had significantly decreased by fasting. In the kidney, IGFBP-2 gene expression was observed but not influenced by fasting and refeeding. Recently, we have demonstrated in vivo that gizzard and hepatic IGFBP-2 gene expression in fasted chickens was rapidly reduced by intravenous administration of insulin, as indicated that in young chickens the reduction in gizzard and hepatic IGFBP-2 gene expression in vivo stimulated by malnutrition may be, in part, regulated by means of the increase in plasma insulin concentration via an insulin-response element. The influence of dietary protein source (isolated soybean protein vs. casein) and the supplementation of essential amino acids on gizzard IGFBP-2 gene expression was examined. In both soybean protein and casein diet groups, the deficiency of essential amino acids stimulated chickens to increase gizzard IGFBP-2 gene expression. Although amino acid supplementation of a soybean protein diet significantly decreased gizzard IGFBP-2 mRNA levels, a similar reduction was not observed in chickens fed a casein diet supplemented with amino acids. This overview of nutritional regulation of IGF-I and IGFBP-2 gene expression in young chickens would serve for the establishment of the supply of nutrients to diets to improve poultry production.