• 제목/요약/키워드: VP8

검색결과 273건 처리시간 0.03초

효과적인 사이버 쇼핑몰을 위한 VP 데이타베이스 지원 (VP Database Support for a More Efficient Cyber Shopping Mall)

  • Lim, Jaeguk;Kang, Hyunchul;Han, Sangyong
    • 정보기술과데이타베이스저널
    • /
    • 제8권1호
    • /
    • pp.1-11
    • /
    • 2001
  • More and more cyber shopping malls, one of the new promising Internet businesses of today, are opening business everyday. And instead of the ordinary image and text type of product display, buyers can now view products from any viewpoint through 3D images and also get more detail information on the product more easily thanks to the new VP technology, visual tools, and statecharts. However the currently used virtual prototyping supporting method does not consist of any database support for sharing the data from different virtual prototype developments and reusing the data in developing other prototypes. And in cases of custom order products, there is no linkage with the virtual product database that enables buyers in cyberspace such as cybermalls to try out the products before purchasing. This paper is purported for being applied as the basis for planning the construction of a complete CRM method applied cyber shopping mall that can accommodata all the demands and requests from customers. And the database supporting VP framework that supports data sharing and collaboration between virtual prototype developers and manufacturing custom order products is suggested for this purpose.

  • PDF

초음파 시험법에 의한 실존 콘크리트 구조체의 압축강도 제안식에 관한 연구 (A New Equation for the Compressive Strength. of Existing Concrete Structures by Ultrasonic Pulse Velocity Test)

  • 권영웅;신정식;유재은;이성용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.757-762
    • /
    • 2003
  • This paper concerns the new equations for the compressive strength of existing concrete structures by ultrasonic pulse velocity test. The proposed equation are as follows; fc =5255.9 - 3365.8Vp + $548.4Vp^2$ (here, $r^2$=89.7%)

  • PDF

단품 압궤 시뮬레이션을 이용한 FMH 충격흡수부재의 설계방법에 관한 연구 (Designing FMH Impact-Absorbing Structure by Using Subcomponent Collapse Simulation)

  • 김지훈;전인기;최재민;김성훈
    • 대한기계학회논문집A
    • /
    • 제34권8호
    • /
    • pp.1113-1118
    • /
    • 2010
  • 차량의 내장부품 설계에 있어 내장 부품의 탑승자 보호를 위한 FMVSS 201 법규에 따른 FMH 충격성능 만족을 위한 충격흡수구조 설계 방법이 필요하다. 충격흡수구조 설계 과정에 있어 FMH 충격 성능은 헤드라이닝의 타격 위치 및 헤드폼의 접근각에 따라 위치별로 각각 다르게 설정되며, FMH 충격 흡수부재는 위치에 따른 차체의 강성 및 상관부품을 고려하여 각 타격 위치에 따른 적절한 충격 흡수 성능을 가져야 하며 차체 강성의 변화를 고려한 효율적인 설계 방법이 필요하다. 본 연구에서는 충격 흡수구조 설계 과정에 있어 초기 설계안에 대한 충격 강도 검토의 시간을 줄이기 위해 전차량 시뮬레이션에서 수행하던 FMH 충격흡수부재 설계를 단위 모델의 압궤 시뮬레이션을 통해 진행함으로써 보다 빠르고 효율적으로 타격 위치별 적합한 충격 흡수구조를 설계하는 방법을 검토하였다.

흉부(胸部)의 X선촬영(線撮影) 및 촬영장치(撮影裝置) 현황(現況)에 관(關)한 조사(調査) (A Study on Radiographic Equipments and Situation for the Chest)

  • 고신관;안봉선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제8권2호
    • /
    • pp.3-9
    • /
    • 1985
  • From the study on the chest radiologic equipments and situations of university hospitals, general hospitals, and radiologic clinics located in Seoul area and Choong-cheong province, the author got conclusions as follows : 1. The rectfication methods of the equipments were employing mainly single or three-phase full wave, and 78% of the examined were using single phase full wave. 2. The focal sizes in case of small focus were less than 1.0mm in chest-only use, and more than 1.0mm in 81% of combined use. The focal sizes in case of large focus were more than 1.6mm in 78% of the total. 3. Maximum ratings of x-ray tubes were 47% at 125 kVp maximum tube voltage and 41% at 150kVp. The maximum tube currentes higher than 500mA were shown in 72% of all the examined. And the maximum exposure time was the range of 5-8sec. 4. Grid was not used in the 66% of all the hospitals. Equipment for chest-only was employing 10:1 grid ratio and the 2.0-2.9mmAl of total filtration formed 38% of all the examined. 5. In the processing time of exposed film, 68% of all was 90sec, and only 20% of all the examined used optimum developing temperature according to this condition. 6. In the radiographic conditions, more than 50% used low tube voltages lower than 70 kVp and only 3% of all the equipments used high tube voltages higher than 100 kVp. The 46.9% of all the equipments 300mA, and 53% of all used shorter exposure time less than 1/20(0.05) sec. 7. In the monthly average number of radiographs, 44% of all was x-ray the radiographs.

  • PDF

ConeBeam CT로 임플란트 검사 시 MAR 기능 유무와 선량조건에 따른 정량적 및 정성적 평가 (Quantitative and Qualitative Evaluation according to Radiation Dose Conditions when using MAR function in Implant examination from Cone Beam CT)

  • 안현준;김상현
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.905-917
    • /
    • 2022
  • 본 연구는 각각의 방사선 선량 조건을 나눠 검사할 때 MAR 기능의 사용과 영상 품질을 평가하기 위해 수행되었다. 실험을 위해 임플란트가 박힌 간단한 Periapical Phantom을 만들었고, CBCT 장비를 이용하여 선량 조건별로 MAR 기능의 유무에 따라 영상을 획득하고 실험에 임하였다. 본 연구에서는 Image J 프로그램을 이용하여 MEAN, SNR, 그리고 CNR 값들을 획득하였고, 통계 분석을 통해 Abutment of Implant 부분은 100 kVp, 8 mA 조건일 때, Center of Implant와 Apex of Implant 부분에서는 100 kVp, 9 mA 조건일 때 영상이 가장 정량적이고 적합한 값이었다. 따라서 방사선량이 증가하면 영상의 Pixel value, SNR, CNR 값이 상승해 화질이 향상되고, MAR 기능을 사용하면 Artifact가 줄어드는 것을 확인할 수 있었다.

Tube Voltage, DNA Double-Strand Breaks, and Image Quality in Coronary CT Angiography

  • Zhu Xiao Lin;Fan Zhou;U. Joseph Schoepf;Balakrishnan Pillai;Chang Sheng Zhou;Wei Quan;Xue Qin Bao;Guang Ming Lu;Long Jiang Zhang
    • Korean Journal of Radiology
    • /
    • 제21권8호
    • /
    • pp.967-977
    • /
    • 2020
  • Objective: To evaluate the effects of tube voltage on image quality in coronary CT angiography (CCTA), the estimated radiation dose, and DNA double-strand breaks (DSBs) in peripheral blood lymphocytes to optimize the use of CCTA in the era of low radiation doses. Materials and Methods: This study included 240 patients who were divided into 2 groups according to the DNA DSB analysis methods, i.e., immunofluorescence microscopy and flow cytometry. Each group was subdivided into 4 subgroups: those receiving CCTA only with different tube voltages of 120, 100, 80, or 70 kVp. Objective and subjective image quality was evaluated by analysis of variance. Radiation dosages were also recorded and compared. Results: There was no significant difference in demographic characteristics between the 2 groups and 4 subgroups in each group (all p > 0.05). As tube voltage decreased, both image quality and radiation dose decreased gradually and significantly. After CCTA, γ-H2AX foci and mean fluorescence intensity in the 120-, 100-, 80-, and 70-kVp groups increased by 0.14, 0.09, 0.07, and 0.06 foci per cell and 21.26, 9.13, 8.10, and 7.13 (all p < 0.05), respectively. The increase in the DNA DSB level in the 120-kVp group was higher than those in the other 3 groups (all p < 0.05), while there was no significant difference in the DSBs levels among these latter groups (all p > 0.05). Conclusion: The 100-kVp tube voltage may be optimal for CCTA when weighing DNA DSBs against the estimated radiation dose and image quality, with further reductions in tube voltage being unnecessary for CCTA.

에너지 변조 필터로 구현한 이중 에너지 콘빔 CT의 에너지 스펙트럼 평가 연구 (Analysis of Beam Hardening of Modulation Layers for Dual Energy Cone-beam CT)

  • 안소현;조삼주;금기창;최상규;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제27권1호
    • /
    • pp.8-13
    • /
    • 2016
  • 이중 에너지 콘빔 CT는 원자번호가 다른 두 물질을 구분해낼 수 있다는 장점을 가진다. 이중 에너지 콘빔 CT를 구현하는 여러 가지 방법 중, 에너지 변조 필터(modulation layer)에 기반한 이중 에너지 콘빔 CT의 원리는 x-선 발생창의 절반을 구리와 같은 에너지 변조 필터로 차단하면, 차단되지 않은 곳에서는 원래의 관전압에 해당하는 x-선 스펙트럼이 발생하고 에너지 변조 필터로 가려진 부분에서는 저에너지 x-선이 감소된 x-선 스펙트럼이 발생하여 한 번의 스캔에서 두 가지 스펙트럼을 획득할 수 있다는 것이다. 우리는 에너지 변조 필터를 이용한 이중 에너지 콘빔 CT 구현의 가능성을 평가하기 위하여 다양한 두께의 에너지 변조 필터에 의해 생성되는 x-선 스펙트럼을 몬테칼로 전산모사를 이용하여 획득하였다. 전산모사 결과를 검증하기 위하여 동일한 콘빔 CT 시스템에서 CdTe 검출기를 이용하여 50~100 kVp에 대하여 스펙트럼을 측정하였고, 80 kVp 관전압에 대하여 실험과 전산모사로 획득한 스펙트럼의 평균 에너지가 유사함을 확인하였다. 또한 에너지 변조 필터의 두께를 2.0 mm로 하였을 때 스펙트럼의 평균 에너지는 80과 120 kVp에 대하여 각각 1.67, 1.52배까지 증가함을 확인하였다. 따라서 에너지 변조 필터를 사용하면 하나의 x-선 발생장치를 이용하여 가상의 이중 에너지 선원을 구현할 수 있음을 확인하였다.

겨울 김치에 대한 팽창 방지 포장 기법 (Packaging Techniques to Prevent Winter Kimchi from Inflation)

  • 홍석인;박노현;박완수
    • 한국식품과학회지
    • /
    • 제28권2호
    • /
    • pp.285-291
    • /
    • 1996
  • 소포장 김치의 팽창 파열방지 포장기법으로서 각 포장방법의 효과를 평가하기 위해 겨울 배추를 원료로 제조한 김치 에 대하여 포장방법 에 따른 품질변화를 확인하였다. 상압(AP), 배기(CV), 이중(DP), 진공(VP) 등으로 포장방법을 달리하여 김치의 품질변화를 관찰한 결과, 저장기간이 증가함에 따라 AP와 CV의 포장내$O_2$ 농도는 지수적으로 감소하고 $CO_2$, 농도는 선형으로 증가하다가 일정해졌다. DP에서 $O_2$ 농도는 감소 후 증가, $CO_2$ 농도는 증가 후 감소하는 양상을 보였으며 VP는 저장말기에 저농도 $O_2$와 고농도 $CO_2$ 일정하게 유지하는 등 각기 다른 경향을 나타내었다 포장내 자유용적은 AP에서 S자 곡선형으로 증가하였으나 CV와 DP는 거의 일정하였고 VP는 저장중기 이후 급격히 증가하기 시작하여 가장 높은 최중 용적량을 나타내었다. 각포장구의 pH는유의차 없이 대부분 비슷하였으나 산도는 DP가 다른 포장구에 비해 상대적으로 약간 높은 값을 유지하였다. 분쇄 김치 여과액의 색지수는 지수적으로 감소하다가 일정하게 유지되는 경향을 보였는데, 포장방법에 따른 차이는 거의 구분할 수 없었으나 VP가 다소 높게 나타탔다. 젖산균수의 변화에 있어서도 포장방법에 관계없이 저장초기 급격히 증가하여 중기 이후 일정하였다. 관능검사 결과 전반적으로 신맛이나 조직감은 각 포장구에서 유의차를 볼 수 없었다 결론적으로 김치의 팽창 파열방지 포장기 법으로서 배기포장과 이중포장이 매우 효과적이며 제한적 범위 내에서 진공포장도 상당히 효과적임을 알 수 있었다.

  • PDF

Digital Radiography(DR)에서 검출기의 X선 조건에 따른 흡수선량 및 영상화질 변화에 관한 연구 (Study on the Change of Absorbed Dose and Image Quality according to X-ray Condition of Detector in Digital Radiography(DR))

  • 황준호;정재호;김현수;이경배
    • 한국콘텐츠학회논문지
    • /
    • 제17권9호
    • /
    • pp.99-106
    • /
    • 2017
  • 본 연구는 진단용 검출기가 결함이 발생하는 경우 환자의 방사선 피폭과 영상의 화질에 영향을 줄 수 있다는 점에 착안하여 실험을 진행하였고 선량분석을 통해 검출기 성능을 신호 대 잡음비와 대조도 대 잡음비로 평가하였다. 선량계, 조직등가팬텀을 이용해 흡수선량과 신호 대 잡음비, 대조도 대 잡음비를 측정하였다. 실험방법은 팬텀 후면에 부착하여 나온 선량 값과 검출기 뒤에 부착한 선량 값이 일치하는지를 비교하였고 두개부 흉부 복부의 조건을 각각 75 kVp 25 mAs, 110 kVp에 8 mAs, 80 kVp에 20mAs로 설정하고 검사하였다. 그 결과 검출기의 뒤쪽에 부착한 선량값은 0.004 mGy, 0.006 mGy, 0.003 mGy로 나타났고, 팬텀 후면은 0.006 mGy, 0.016 mGy, 0.017 mGy로 차이가 있었다. 두 값을 일치시키기 위해서 조건이 증가하였고 신호 대 잡음비와 대조도 대 잡음비는 88.32, 88.10, 4.09, 1.63, 87.94, 79.97에서 93.87, 93.75, 4.91, 4.03, 92.02, 84.92로 증가하였다. 본 연구를 통해 검출기가 노후화 되는 경우 기기의 수명단축과 환자의 선량증가의 원인이 되었으며 또한 영상화질의 개선효과도 미비하다는 것을 알 수 있었다.