Biological and molecular characterization of feline caliciviruses isolated from cats in South Korea

  • Yang, Dong-Kun;Park, Yu-Ri;Yoo, Jae Young;Choi, Sung-Suk;Park, Yeseul;An, Sungjun;Park, Jungwon;Kim, Heui-Jin;Kim, Jongho;Kim, Ha-Hyun;Hyun, Bang-Hun
    • 대한수의학회지
    • /
    • 제60권4호
    • /
    • pp.195-202
    • /
    • 2020
  • Feline calicivirus (FCV) infection results in a common upper respiratory disease associated with oral ulceration in cats. Although FCV infection has been reported in cats worldwide, the biologic and genetic features of South Korean FCV are unclear. We aimed to investigate the biological and genetic features of South Korean FCV isolates. Crandell-Rees feline kidney (CRFK) cells were used to isolate FCV from 58 organ homogenate samples. The FCV isolates were confirmed by cytopathic effects, immunofluorescence, electron microscopy, and reverse transcription polymerase chain reaction assays. Viral genetic analysis was carried out with VP2 gene and complete genomes of FCVs. Five viruses propagated in CRFK cells were confirmed to be FCVs. The FCV17D283 isolate showed the highest viral titer of 107.2 TCID50/mL at 36 h post-inoculation. Korean FCV isolates did not grow well in Vero, BHK-21, A72, or Madin-Darby canine kidney cells. The FCV17D03 and FCV17D283 isolates had the highest genetic similarity (80.1% and 86.9%) with the UTCVM-H1 and 14Q315 strains, which were isolated in the United States and South Korea in 1995 and 2014, respectively. We isolated five FCVs from cats and detected important genetic differences among them. FCV isolates did not show any virulent effects in mice.

Diagnostic Efficacy and Safety of Low-Contrast-Dose Dual-Energy CT in Patients With Renal Impairment Undergoing Transcatheter Aortic Valve Replacement

  • Suyon Chang;Jung Im Jung;Kyongmin Sarah Beck;Kiyuk Chang;Yaeni Kim;Kyunghwa Han
    • Korean Journal of Radiology
    • /
    • 제25권7호
    • /
    • pp.634-643
    • /
    • 2024
  • Objective: This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in patients with compromised renal function. Materials and Methods: A total of 54 consecutive patients (female:male, 26:38; 81.9 ± 7.3 years) with reduced renal function underwent pre-TAVR dual-energy CT with a 30-mL contrast agent between June 2022 and March 2023. Monochromatic (40- and 50-keV) and conventional (120-kVp) images were reconstructed and analyzed. The subjective quality score, vascular attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared among the imaging techniques using the Friedman test and post-hoc analysis. Interobserver reliability for aortic annular measurement was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The procedural outcomes and incidence of post-contrast acute kidney injury (AKI) were assessed. Results: Monochromatic images achieved diagnostic quality in all patients. The 50-keV images achieved superior vascular attenuation and CNR (P < 0.001 in all) while maintaining a similar SNR compared to conventional CT. For aortic annular measurement, the 50-keV images showed higher interobserver reliability compared to conventional CT: ICC, 0.98 vs. 0.90 for area and 0.97 vs. 0.95 for perimeter; 95% limits of agreement width, 0.63 cm2 vs. 0.92 cm2 for area and 5.78 mm vs. 8.50 mm for perimeter. The size of the implanted device matched CT-measured values in all patients, achieving a procedural success rate of 92.6%. No patient experienced a serum creatinine increase of ≥ 1.5 times baseline in the 48-72 hours following CT. However, one patient had a procedural delay due to gradual renal function deterioration. Conclusion: Low-contrast-dose imaging with 50-keV reconstruction enables precise pre-TAVR evaluation with improved image quality and minimal risk of post-contrast AKI. This approach may be an effective and safe option for pre-TAVR evaluation in patients with compromised renal function.

유방암 환자의 수술 중 방사선치료 시 피부선량 측정을 통한 안전성 평가 (Evaluation of safety by skin dosimetry in Intraoperative Radiotherapy for breast cancer patients)

  • 정인호;김준원;박광우;하진숙;전미진;조윤진;김세준;김종대;신동봉
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.13-22
    • /
    • 2015
  • 목 적 : 유방암 환자를 대상으로 Intrabeam$^{TM}$ system을 이용한 수술 중 방사선치료(Intraoperative Radiotheray, IORT)를 국내에 처음 도입하는데 있어 광자극형광선량계(Optically Stimulated Luminescent Dosimeter, OSLD)를 이용한 피부선량측정을 통해 Intrabeam$^{TM}$ system의 안정성을 평가하고자 한다. 대상 및 방법 : 본원에서 2014년 8월부터 2015년 2월까지 유방보존술(breast-conserving surgery, BCS)후 Intrabeam$^{TM}$ system을 이용하여 수술 중 방사선치료(IORT)를 시행한 30명의 유방암 환자를 대상으로 진행하였다. 처방선량은 applicator 표면을 기준으로 20 Gy로 설정하여 1 cm 떨어진 지점에 약 5 Gy의 선량이 전달될 수 있도록 하였다. 종양 크기에 따라 applicator의 크기를 결정하였고 치료시간은 applicator의 크기에 따라 18~40분으로 설정되었다. 피부 절개면에서 Superior, Inferior, Lateral, Medial 4방향에 applicator를 중심으로부터 0.5 cm와 1.5 cm지점에 광자극형광선량계(OSLD)를 각각 부착하였다. 각 방향에 따라 U1,U2(Superior), D1,D2(Inferior), L1,L2(Lateral), M1,M2(Medial)로 총 8지점을 지정하였다. 각 지점에서의 측정값과 모든 지점의 평균값 및 최고값, 최저값을 산출하여 비교분석 하였다. 결 과 : Intrabeam$^{TM}$ system 50kVp X-ray source를 이용한 수술 중 방사선치료(IORT)시 OSLD의 측정 결과 U1 $2.23{\pm}0.80Gy$, U2 $1.54{\pm}0.53Gy$, D1 $1.73{\pm}0.63Gy$, D2 $1.25{\pm}0.45Gy$, L1 $1.95{\pm}0.82Gy$, L2 $1.38{\pm}0.42Gy$, M1 $2.03{\pm}0.70Gy$, M2 $1.51{\pm}0.58Gy$로 나타났으며 maximum값은 U1지점에서 4.34 Gy, minimum값은 M2지점에서 0.45 Gy로 나타났다. 전체 환자 중 13.3 %(N=4/30) 환자에서 4 Gy를 초과하는 측정값이 나타나 그 원인을 분석하였다. 결 론 : 본 연구를 통해 현재 본원에서 도입한 Intrabeam$^{TM}$ system을 이용한 수술 중 방사선치료(IORT)는 모든 환자의 피부선량값이 5 Gy미만으로 측정된 것으로 보아 그 안전성이 확인되었다. 피부선량이 4 Gy를 초과한 환자의 데이터 분석을 통해 breast volume이 상대적으로 작은 사이즈의 유방암환자의 경우 피부선량이 증가하는 경향을 보여 수술 중 방사선 치료 대상 환자 선정시 종양의 크기와 위치 뿐만 아닌 breast volume 값 등을 고려하여 피부에 전달되는 선량값이 기준값을 초과하지 않도록 주의 하여야 한다.

  • PDF

폐질환의 선별검사를 위한 저선량 전산화 단층촬영의 적용 (Application of Low-Dose CT for Screening of Lung Disease)

  • 이원정;최병순;박영선;선종률;배석환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권2호
    • /
    • pp.129-140
    • /
    • 2009
  • 전산화 단층촬영은 폐질환의 정밀진단 방법으로 사용이 증가되고 있다. 통상적으로 시행되는 CT촬영은 조기 진단을 위한 선별검사로써는 높은 방사선 노출과 고비용, 조영제 사용으로 인한 부작용 등으로 적당하지 않다. 영상의학분야에서 방사선을 이용한 CT촬영은 진단 능력이 우수한 반면 피폭선량 또한 매우 높아 선량 감축을 위한 노력이 절실하다. 그동안 많은 연구들에서 무증상기의 폐암 및 폐질환을 조기 발견하기 위한 선별검사로써 저선량 CT의 유용성에 대해 이루어져 왔고, 의미있는 결과를 보고하였다. 선량 감소에 많은 인자가 관여하고 있지만 조사선량(mAs)의 감소가 가장 많이 사용되고 있다. 이미 보고 된 많은 연구에서 저선량 CT는 폐질환을 조기 발견하기 위한 선별검사로써 임상에서 사용하기에 유용하지만, 일부 연구에서 조기 폐암을 예측할 수 있는 작은 결절을 발견하는데 낮은 민감도와 특이도를 보였고, 실제 생존율 증가에는 기여하지 못한 보고도 있었다. 따라서, 지금까지의 저선량 CT에 대한 연구결과를 토대로 다양한 위험에 노출된 집단을 대상으로 선량을 감소시키기 위한 연구가 계속적으로 이루어진다면, 향후 저선량 CT촬영은 폐암을 비롯한 폐질환의 조기진단 방법으로써 통상적으로 사용되고 있는 표준 CT촬영을 충분히 대체할 수 있을 것으로 전망한다.

  • PDF

가공변수의 불확실성을 고려한 전자제어식 차동제한장치 솔레노이드 어셈블리의 강건 최적설계 (Robust Optimization of the Solenoid Assembly in Electromagnetic Limited Slip Differential by Considering the Uncertainties in Machining Variables)

  • 오상균;이광기;서창희;정윤철;김영석
    • 대한기계학회논문집A
    • /
    • 제35권10호
    • /
    • pp.1307-1313
    • /
    • 2011
  • 전자제어식 차동제한 장치는 기계식에 비해서 능동제어가 가능하고 응답성이 좋아 기계식을 대체해 나가고 있다. STS 304 재질의 코일 하우징은 전자제어식 차동제한장치의 솔레노이드 어셈블리에서 가장 중요한 부품이다. 코일 하우징의 제조시 높은 형상 정밀도가 필수적이나, STS 304의 박판 사용과 가공변수의 변동으로 정밀 가공이 어렵다. 본 연구의 목적은 코일하우징의 가공조건에서 강건해를 구하여 평균과 변동을 최적화 하는 것이다. 코일하우징의 형상정밀도 평균과 표준편차를 최소화 하기 위한 주요 변수로 조의 척킹압력, 절삭속도, 이송속도의 평균과 표준편차가 고려됐다. 가공변수의 변동을 고려하여 평균과 표준편차를 모두 최소화 하는 최적의 조건을 선정하고자 반응표면모델 기반 2차 테일러 전개를 통한 강건 최적설계를 수행하였다.

흉부CT 검사 시 HRCT 영상 재구성의 유용성 (Usefulness Evaluation of HRCT using Reconstruction in Chest CT)

  • 박성민;김긍식;강성민;유병규;이기배
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

혈관신생 및 이식암세포증식 억제를 통한 가미소암산의 항암작용연구 (Studies on the Antitumor Activity of Gamisoam-san via Suppressing Angiogenesis and Growth Factor Expression)

  • 윤성찬;안성훈;문연자;김진경;추영국;정규용;김영목;우원홍
    • 동의생리병리학회지
    • /
    • 제17권4호
    • /
    • pp.969-979
    • /
    • 2003
  • Gamisoamsan is a prescription originated in Soamsan which is known as an anti-cancer remedy in the traditional Korean Medicine. To enhance the synergic effects of anti-cancer activity of Soamsan, this study reconstituted the original components of Soamsan with a slight modification and produced a novel herbal remedy, namely Gamisoamsan. To investigate the effects of Gamisoamsan on anti-cancer reaction, I studied the effects of Gamisoamsan on angiogenesis via chorioallantoic membrane (CAM) assay, corneal neovascularization assay and the effects on expression of growth factor which are VEGF, TGF-β, bFGF and IMUP-1. Anti-cancer effects of Gamisoamsan was also abserved through hematological parameters, tumor volume and survival rate in mice. Gamisoamsan inhibited embryonic angiogenesis of blood vessels in CAM assay and inhibited neovascularization of ral cornea. Gamisoamsan reduced cell proliferation in HT1080 cells and IC50 was 2.18 ㎎/㎖ Gamisoamsan reduced the expression of VEGF, TGF-β, bFGF and IMUP-1 which was known as vascular growth factor and this effects of Gamisoamsan was predominant than VP-16. The treatment of Gamisoamsan decreased the CT-26 cell inoculated-tumor volume in mice colon adenocarcinoma and increased mice survival which was inoculated CT-26 cells. The results of the present study suggest that Gamisoamsan extracts has a potential anti-tumor activity and may be an useful remedy to prevent and/or treat cancer.

Molecular epidemiology of Aleutian mink disease virus causing outbreaks in mink farms from Southwestern Europe: a retrospective study from 2012 to 2019

  • Prieto, Alberto;Fernandez-Antonio, Ricardo;Lopez-Lorenzo, Gonzalo;Diaz-Cao, Jose Manuel;Lopez-Novo, Cynthia;Remesar, Susana;Panadero, Rosario;Diaz, Pablo;Morrondo, Patrocinio;Diez-Banos, Pablo;Fernandez, Gonzalo
    • Journal of Veterinary Science
    • /
    • 제21권4호
    • /
    • pp.65.1-65.13
    • /
    • 2020
  • Background: Aleutian mink disease virus (AMDV) causes major economic losses in fur-bearing animal production. The control of most AMDV outbreaks is complex due to the difficulties of establishing the source of infection based only on the available on-farm epidemiological data. In this sense, phylogenetic analysis of the strains present in a farm may help elucidate the origin of the infection and improve the control and biosecurity measures. Objectives: This study had the following aims: characterize the AMDV strains from most outbreaks produced at Spanish farms between 2012-2019 at the molecular level, and assess the utility of the combined use of molecular and epidemiological data to track the possible routes of infection. Methods: Thirty-seven strains from 17 farms were partially sequenced for the NS1 and VP2 genes and analyzed phylogenetically with other strains described worldwide. Results: Spanish AMDV strains are clustered in four major clades that generally show a good geographical correlation, confirming that most had been established in Spain a long time ago. The combined study of phylogenetic results and epidemiological information of each farm suggests that most of the AMDV outbreaks since 2012 had been produced by within-farm reservoirs, while a few of them may have been due to the introduction of the virus through international trade. Conclusions: The combination of phylogenetic inference, together with epidemiological data, helps assess the possible origin of AMDV infections in mink farms and improving the control and prevention of this disease.

S-align 기능을 이용한 흉부 전·후 방향 검사 시 적절한 X선관 각도에 관한 연구 (The Study of Appropriate X-ray Tube Angle for the Anterior-posterior Chest Radiography Using S-align Function)

  • 박명주;주영철;김민석;육정원;김한용;김동환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권4호
    • /
    • pp.299-304
    • /
    • 2022
  • This study uses the 'S-align' function to present a reference value of the X-ray tube angle for the realization of an image similar to that of the chest PA image during chest AP radiography. This study targeted dummy phantom and used a 17"×17" DR image receptor. The irradiation conditions were 110 kVp, 160 mA, 50 ms, and the distance between the central X-ray and the image receptor was set to 180 cm and 110 cm, respectively. The end of the catheter was placed at the 11th thoracic height to indicate the nasogastric tube. In the case of lung apex length measurement, the mean value of measurement was 30.53±0.47 in PA. T 0°, TCA 5~25°, TCE 5~15° were 21.07±0.29, 27.60±0.21, 34.13±0.44, 39.86±0.31, 45.96±0.61 mm, 54.13±0.37 mm, 16.16±0.46 mm, 9.81±0.35 mm, 2.75±0.30 mm, respectively. For the depth of the catheter end, the average value measured at PA was 6.70±0.31 mm. T 0°, TCA 5~25°, TCE 5~15° were 15.72±0.38 mm, 24.10±0.50 mm, 29.24±0.86 mm, 34.35±0.35 mm, 41.06±1.08 mm, 48.07±0.38 mm, 12.85±0.25 mm, 7.92±0.36 mm, 3.01±0.39 mm, respectively. The length of the lung apex was similar to that of chest PA when the angle of incidence was adjusted from 5° to 10° in the leg direction, and the depth of the catheter tip was most similar when the X-ray tube angle was incident at 10° in the head direction. Therefore, To change the X-ray tube angle according to the purpose of the examination during the chest AP radiography using 'S-align' function is considered necessary.

전산화 방사선촬영(CR) 시스템을 이용한 근사적 의료 피폭 선량 평가 (Evaluation of Approximate Exposure to Low-dose Ionizing Radiation from Medical Images using a Computed Radiography (CR) System)

  • 우민선;이재승;임인철
    • 한국방사선학회논문지
    • /
    • 제6권6호
    • /
    • pp.455-464
    • /
    • 2012
  • 본 연구는 일반 X선 검사에서 CR 시스템을 이용한 환자의 근사적 피폭 선량을 평가할 수 있는 실험적 모델을 제시하고 저선량 영역에서 의료 피폭에 대한 방어의 최적화 조건으로 환자의 선량 권고량(diagnostic reference level. DRL)을 비교하고자 하였다. 이를 위하여 기준선량계와 광자극발광선량계(optically stimulated luminescence dosimeters. OSLDs)를 이용하여 관전압(kVp) 및 관전류 노출시간의 곱(mAs)에 따른 입사표면선량(entrance surface dose. ESD)을 교차 측정하였으며 CR 시스템에서 각 노출 조건에 대한 Hounsfield unit (HU) scale을 측정하여 ESD와 HU 스케일에 대한 특성 관계를 이용하여 근사적 피폭 선량을 구하였다. 또한 임상적으로 적용 가능한지를 알기 위하여 두부, 경부, 흉부, 복부, 골반부 노출 조건으로 물 팬텀에 모사하여 피폭 선량을 구하였다. 결과적으로 두 선량계의 평균 ESD는 각각 2.10, 2.01, 1.13, 2.97, 1.95 mGy 이었으며 CR 영상에서 측정한 HU 스케일은 각각 $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, $2,318{\pm}4.64$ 이었다. 이 때 ESD와 HU 스케일에 대한 특성 관계를 이용하여 근사적으로 구한 ESD는 각각 2.16, 2.06, 1.19, 3.05, 2.07 mGy이었으며 평균 측정값과 근사적으로 구한 ESD의 오차는 3% 미만으로 영상의학 분야의 측정 오차 5%를 감안한다면 신뢰할 수 있는 오차 범위라 할 수 있었다. 결론적으로 CR 시스템을 이용한 일반 X선 검사에서 환자의 피폭 선량을 근사적으로 평가할 수 있는 새로운 실험적 모델을 제시하였으며 CR 검사뿐 만 아니라 디지털 방사선촬영(digital radiography. DR) 시스템 및 필름-증감지 시스템에 적용 가능할 것으로 판단되었다.