• 제목/요약/키워드: VOCs in air

검색결과 600건 처리시간 0.039초

실내공기중의 휘발성유기화합물 농도변화에 관한 연구 (A Study on Concentration of Volatile Organic Compounds in the Apartment House)

  • 이윤규
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.129-136
    • /
    • 2004
  • Recently, indoor air pollution has been seriously apprehended, and became a striking issue, due to the airtightness of buildings or the misuse of building materials. Especially, SHS(Sick House Syndrome) and MCS(Multi Chemical Sensitivity) which can have bad influences on the resident in an existing apartment house as well as newly constructed apartment house start to attract public attention. The emission rates of VOCs is sensitively affected by the indoor/outdoor condition, construction materials, construction method, and character of ventilation facilities. Therefore, in this study, by measuring the indoor air pollution substance of the existing apartment house, the problem over this tends to be grasped and it is going to secure an improvement methods.

식물을 이용한 실내공기정화용 정보시스템 설계에 대한 연구 (A Study on IT System Design for Eco-Amenity)

  • 노용덕;이정훈
    • 정보처리학회논문지D
    • /
    • 제13D권7호
    • /
    • pp.971-976
    • /
    • 2006
  • 새집증후군과 같이 실내공기의 오염은 최근에 많은 관심을 갖는 영역중 하나이다. 이 오염을 제거하는 효과적인 방법중의 하나가 친환경적인 식물의 공기정화 기능을 활용하는 것이다. 이러한 식물들은 잎사귀를 통하여 오염물질을 흡수하며 동시에 음이온을 발생시켜 실내환경을 개선시킨다. 여기서는 건물의 공기오염원에 따른 적절한 식물의 선택, 배치, 및 관리정보를 제공하는 실내공기정화용 정보시스템에 대하여 기술하고자 한다.

흡착보양재 적용에 따른 실내 오염물질 초기제어 성능에 관한 연구 (A Study on Initial Control Performance of the Adsorption Protector for Construction Surface about Contaminant)

  • 허정용;최창호;이윤규
    • 설비공학논문집
    • /
    • 제21권4호
    • /
    • pp.229-235
    • /
    • 2009
  • In a domestic construction field, floor surface must be covered not to be scratched and polluted by protector until resident comes in. However this protector restricts the contaminant to leave from floor surface. So when the protector is removed, much contaminant is emitted from the floor surface to inside and makes a bad influence on the indoor air quality, In this research, it will be tested the reduction performance of contaminant between a normal protector and a contaminant absorption protector using charcoal powder.

신축 공동주택에서 실내공기오염물질(휘발성유기화합물 및 카보닐화합물) 농도분포 특성 (Characteristics of concentration distribution for indoor air pollutants (VOCs and Carbonyl compounds) in new apartments)

  • 장성기;천재영;이태형;임수길;류정민;서수연;임정연
    • 분석과학
    • /
    • 제20권1호
    • /
    • pp.17-24
    • /
    • 2007
  • 신축공동주택에서 발생되는 실내공기 오염물질 중 휘발성유기화합물 및 카보닐화합물의 농도분포특성을 파악하고자 신축공동주택 120세대를 대상으로 실내공기 오염도 실태조사를 실시한 결과, 입주 전 신축공동주택의 실내공기 오염물질 농도는 톨루엔이 $272.81{\mu}g/m^3$, m, p-자일렌 $98.90{\mu}g/m^3$, 포름알데히드 $71.68{\mu}g/m^3$, 아세톤 $70.58{\mu}g/m^3$, 에틸벤젠 $49.76{\mu}g/m^3$로 조사되었다. TVOCs 물 구성비의 경우, 표준물질로 확인된 물질이 42.5%를 차지하였으며, 이 중 톨루엔이 18.5%로 가장 많은 비중을 차지하였다. 카보닐화합물의 경우, 포름알데히드와 아세톤이 각각 43.1%, 42.4%를 차지하였다. 또한, 주요 실내공기 오염물질의 실내/실외 농도비를 조사한 결과 벤젠은 1.29로 낮은 농도비로 조사되었으며, 톨루엔은 3.59, 포름알데히드는 10.76, o-자일렌은 28.74의 실내/실외 농도비를 나타내었다.

Hybrid Pilot System을 이용한 철도 오염토양 복원 (Remediation of Contaminated Railroad Soils using by Hybrid Pilot System)

  • 박덕신
    • 한국철도학회논문집
    • /
    • 제3권3호
    • /
    • pp.101-108
    • /
    • 2000
  • In this study, we tested hybrid pilot system combined with soil vapor extraction and bioventing methods on the contaminated railroad soil. So, we found out the remediability and operating conditions. Air permeability(k) and gas phase(O$_2$/CO$_2$/VOCs) level trend are very important to determine the remediation rate of the contaminated sites. Throughout hybrid pilot test on different conditions, the range of air permeability(k) was 1985∼1194 darcy. The tests results in hybrid system was appropriate on this test sites, and the suitable injection air flow rate was 3.5㎥/hr. So, we suggested a basic data for the remediation and management of contaminated railroad soil.

  • PDF

철도차량 HVAC시스템의 광플라즈마 성능평가 (Efficiency of Photoplasma of HVAC System for Train)

  • 한환수;전승기;박태영;김봉상;박덕신;권순박
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1293-1296
    • /
    • 2007
  • An amenity requirement of the passenger using public traffic is rising continuously, and also The Ministry of Environment established "Indoor air quality management guidelines in public facilities(Dec. 2006)". To satisfy such requirement, the photoplasma device to decrease VOCs(Volatile Organic Compounds) and suspended bacillus is applied to the underframe mounted HVAC(Heating, Ventilating and Air-Conditioning) system for train. Air purifying method of photoplasma device is optical and chemical reaction that UV-light(wavelength less than 280nm) react with catalyst material(TiO2). To analyze the efficiency of photoplasma in this study, we measured the requirement time for toluene to decease down to 0.3ppm after contaminating the passenger cabin for train to toluene 1ppm.

  • PDF

공기 중 미세먼지와 휘발성유기화합물 제거를 위한 활성탄 전기방사 필터 연구 (Study on Electrospun Activated Carbon Mats for the Filtration of Particulate Matter and Volatile Organic Compound in the Air)

  • 한상일
    • Korean Chemical Engineering Research
    • /
    • 제56권3호
    • /
    • pp.356-360
    • /
    • 2018
  • 인구증가와 개발 도상 국가의 산업 활동 증가로 인해 대기 중 미세먼지농도가 상승함에 따라 생태계에 미치는 영향이 심각해지고 있다. 그로인해 미세먼지발생을 줄이기 위한 정책을 수립하여 시행하거나 미세먼지를 여과해주는 공기청정기나 마스크의 연구가 활발히 이루어지고 있다. 본 연구에서는 전기방사실험을 통해 셀룰로스 아세테이트 파이버 필터를 제조하고 고분자용액에 활성탄을 첨가하여 미세입자 제거에 미치는 활성탄의 영향을 평가하였다. 미세입자 생성을 위해 염화나트륨 수용액을 사용하였으며, 공기 중 수분의 영향을 배제하기 위해 건조기를 설치하여 수분을 제거한 후 필터 성능을 분석하였다. 활성탄이 첨가될수록 미세입자 제거 효율은 증가하였으며, 아세톤 흡착량 또한 증가하였다.

대도시 지역의 배출량 저감에 따른 O3 농도 변화 분석: 부산광역시 2019년 여름 사례 (Analyzing the Changes in O3 Concentration due to Reduction in Emissions in a Metropolitan Area : A Case Study of Busan during the Summer of 2019 )

  • 최현식;전원배;김동진;양채영;문정혁;박재형
    • 한국환경과학회지
    • /
    • 제32권7호
    • /
    • pp.503-520
    • /
    • 2023
  • In this study, numerical simulations using community multiscale air quality (CMAQ) were conducted to analyze the change in ozone (O3) concentration due to the reduction in nitrogen oxides (NOx)andvolatile organic compounds (VOCs) emissions in Busan. When the NOx and, VOCs emissions were reduced by 40% and, 31%, respectively, the average O3 concentration increased by 4.24 ppb, with the highest O3 change observed in the central region (4.59 ppb). This was attributed to the decrease in O3 titration by nitric oxide (NO) due to the reduction of NOx emissions in Busan, which is classified as a VOCs-limited area. The distribution of O3 concentration changes was closely related to NOx emissions per area, and inland emissions were highly correlated with daily maximum concentrations and 8-h average O3 concentrations. Contrastingly, the effect of emission reduction depended on the wind direction. This suggests that the emission reduction effects may vary depending on the environmental conditions. Further research is needed to comprehensively analyze the emission reduction effects in Busan.

다양한 실내환경 중 휘발성유기화합물 오염의 패턴 분류 (Pattern Classification of Volatile Organic Compounds in Various Indoor Environment)

  • 김윤신;노영만;이철민;김기연;김종철;전형진
    • 한국환경보건학회지
    • /
    • 제33권1호
    • /
    • pp.49-56
    • /
    • 2007
  • The purpose of this study was to survey the distribution patterns of volatile organic compounds(VOCs) and formaldehyde in the various indoor environments using cluster analysis. We investigated VOCs and formaldehyde in subway stations, underground shopping areas, medical centers, maternity recuperation centers, public childcare centers, large stores, funeral houses, and indoor parking lots from June,2005 to May,2006. Concentration of TVOCs in maternity recuperations was 2,605.7 ${\mu}g/m^3$ that was higher than the guideline and other facilities. TVOCs in public childcare centers was 1,951.6 ${\mu}g/m^3$ also it exceeded the guideline. Moreover, concentration of TVOCs in every facility exceeded the guideline of Department of Environment, Korea. In case of formaldehyde, mean concentration, 336.5 ${\mu}g/m^3$, in only public childcare centers exceeded the 120 ${\mu}g/m^3$ of the guideline. Finally, by applying cluster analysis, three pattterns of the indoor air pollutions were distinguished. In the results of analysis, concentrations of TVOCs and formaldehyde of cluster 3 were higher than cluster 1 and 2 that were 2,561.4 ${\mu}g/m^3$ and 184.9 ${\mu}g/m^3$, respectively.