• Title/Summary/Keyword: VOCs control technology

Search Result 44, Processing Time 0.029 seconds

Effect of Bacterial Population from Rhizosphere of Various Foliage Plants on Removal of Indoor Volatile Organic Compounds (다양한 관엽식물의 근권부 박테리아 집단이 실내 휘발성 유기화합물질의 제거에 미치는 영향)

  • Chun, Se-Chul;Yoo, Mung-Hwa;Moon, Young-Sook;Shin, Mi-Ho;Son, Ki-Cheol;Chung, Ill-Min;Kays, Stanley J.
    • Horticultural Science & Technology
    • /
    • v.28 no.3
    • /
    • pp.476-483
    • /
    • 2010
  • Total bacterial populations were cultured from the Hydroball cultivation media in the rhizospheres of 9 different plants including $Hedera$ $helix$ L. and $Dracaena$ $deremensis$ cv. Warneckii Compacta, etc. These cultured bacterial populations were studied to test if the bacterial populations in the plant growing pots may play a role on removal of volatile organic compounds (VOCs) such as benzene and toluene in the air. To meet this objective, first, we tested the possibility of removal of VOCs by the cultured total bacteria alone. The residual rates of benzene by the inoculation of total bacterial populations from the different plant growth media were significantly different, ranging from 0.741-1.000 of $Spathiphyllum$ $wallisii$ 'Regal', $Pachira$ $aquatica$, $Ficus$ $elastica$, $Dieffenbachia$ sp. 'Marrianne' Hort., $Chamaedorea$ $elegans$, compared to the control with residual rate of 0.596 (LSD, $P$=0.05). This trend was also similar with toluene, depending on different plants. Based on these results, we inoculated the bacterial population cultured from $P.$ $aquatica$ into the plant-growing pots of $P.$ $aquatica$, $F.$ $elastica$, and $S.$ $podophyllum$ inside the chamber followed by the VOCs injection. The inoculated bacteria had significant effect on the removal of benzene and toluene, compared to the removal efficacy by the plants without inoculation, indicating that microbes in the rhizosphere could play a significant role on the removal of VOCs along with plants.

Efficiency Evaluation of Adsorbents for the Removal of VOC and NO2 in an Underground Subway Station

  • Son, Youn-Suk;Kang, Young-Hoon;Chung, Sang-Gwi;Park, Hyun-Ju;Kim, Jo-Chun
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.113-120
    • /
    • 2011
  • Adsorbent combination studies have been carried out to remove nitrogen dioxide ($NO_2$) and volatile organic compounds (VOCs: BTEX) out of a subway environment characterized by high flow and low concentration. Optimal conditions for the high removal efficiency of the concerned target compounds were obtained through testing a series of control factors such as adsorbent sorts, thicknesses, and superficial velocity. It was found that the efficiencies increased as the specific surface area of activated carbon and its thickness increased, and external void fraction decreased. Furthermore, mixed activated carbon with granular and constructed contents was extensively tested to reduce pressure drop through the carbon bed. It was found that the performance of higher contents of granular activated carbon was better than that of higher contents of the constructed carbon. When the mixed carbon was applied to the subway ventilation system in order to eliminate $NO_2$ and VOC simultaneously, the removal efficiencies were found to be 75% and 85%, respectively.

A Study on Initial Control Performance of the Adsorption Protector for Construction Surface about Contaminant (흡착보양재 적용에 따른 실내 오염물질 초기제어 성능에 관한 연구)

  • Heo, Jung-Yong;Choi, Chang-Ho;Lee, Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.4
    • /
    • pp.229-235
    • /
    • 2009
  • In a domestic construction field, floor surface must be covered not to be scratched and polluted by protector until resident comes in. However this protector restricts the contaminant to leave from floor surface. So when the protector is removed, much contaminant is emitted from the floor surface to inside and makes a bad influence on the indoor air quality, In this research, it will be tested the reduction performance of contaminant between a normal protector and a contaminant absorption protector using charcoal powder.

Syntheses and Characterization of UV-curable Polyurethane Acrylates with Eco-friendly Polyols (친환경 폴리올을 이용한 광경화형 폴리우레탄 아크릴레이트의 합성)

  • Lee, Bong;Kim, Yeong Woo;Lee, Won-Ki
    • Journal of Adhesion and Interface
    • /
    • v.20 no.4
    • /
    • pp.140-145
    • /
    • 2019
  • In view of environmental considerations, the control of carbon dioxide (CO2) and volatile organic compounds (VOCs) is one of important issues in the film and coating industries. Therefore, UV-curable system has been developed due to minimize emissions of VOCs and reduce CO2 emission due to low energy consumption from fast curing. Also, biodegradable polymers economically are attractive because of environmental and economic concerns associated with huge waste plastics. In this study, UV-curable polyurethane acrylates with different compositions of biodegradable polylactide (PLA) diol and poly(ethylene glycol) as diols were synthesized and curing reaction of their end-capped acrylates was performed by UV exposure. Tensile strength, elongation, and Tg of the UV-cured polyurethane acrylates increased with PLA diol content in the diol while their hydrophilicity and thermal stability increased with the PEG content. These results indicated a property of UV-cured polyurethane acrylates could be controlled by environment-friendly diols.

A Study on Removal Efficiency of VOCs using Vortex Cyclones (보텍스 사이클론을 이용한 VOCs 제거효율에 관한 연구)

  • Lim, Gye-Gyu
    • Applied Chemistry for Engineering
    • /
    • v.16 no.2
    • /
    • pp.194-199
    • /
    • 2005
  • The principle of vortex cyclone was applied to enhance the treatment efficiency of waste air streams containing particulate matters, phenol, and others. Adsorption, condensation, and/or coagulation could be induced at low temperature zone formed by Joule-Thomson expansion as the pressurized air and pulverized activated carbon were introduced at the tangential direction into the cyclone system applied with the coaxial funnel tube of vortex cyclone. Easily condensible vapors were adsorbed and/or condensed forcibly on coagulated or condensed materials which were formed as cores for coagulation or condensation by themselves or on pulverized activated carbons. These types of coagulation or condensation rates were rapidly promoted by increase in their diameter. The maximum removal efficiency obtained from this experiment for the removal of carbon dioxide and phenol was about 87.3 and 93.8 percent, respectively. Phenol removal efficiency was increased with the relative humidities and enhanced by pulverized activated carbon added. The Joule-Thomson coefficients were increased with the pressure of air injected in the range of the relative humidities between 10% and 50%. It is believed that the moisture, particulate matters, and the pressure of the process air introduced could control the removal efficiency of VOCs.

Distribution Characteristics of Environmental Contaminant at Soil in an Industrial Complex Area (공단지역 토양 중 환경오염물질 농도 분포 특성)

  • Jung, Jong-Hyeon;Cho, Sang-Won;Lim, Hyun-Sul
    • Clean Technology
    • /
    • v.18 no.2
    • /
    • pp.200-208
    • /
    • 2012
  • This study was performed to prevent the health damage of environmental contaminants in Industrial Complex Area. And, this study aimed to identify the concentration levels and distribution characteristics of environmental contaminants and Polycyclic Aromatic Hydrocarbons (PAHs) at soil in Industrial Complex Area and control area. The concentration of the soil pollution standard such as the heavy metals in the soil, VOCs, PAHs, and PCB were measured and analyzed using the soil specimens in the Industrial Complex Area and control area. Soil specimens from the Industrial Complex Area (the direct exposure area) and the control area were surveyed. Songdo-dong, Haedo-dong and Jechul-dong, which are in the direct exposure area and near the emission source, showed relatively high concentrations of contaminant materials when compared with Jangki-myeon, which is far off and in the control area. The concentration of zinc was 20.8-58.9% of the level of concern (300 mg/kg) in the 1st region, which is a relatively high concentration. The concentration of fluoride was under the standard in every region, but it was about 74% of the level of concern (400 mg/kg) in the 1st region. It is recommended that controlling fluoride emissions is necessary. Levels of organic phosphate, phenol, and VOCs like benzene, toluene, ethylbenzene and xylene were under the detection limit of the analysis instruments. The concentration of TPH was high in Songdo-dong. The concentration of contaminants in Jechul-dong was high. In addition, it was observed that the level of soil contamination changed depending on the distance from the emission source. The concentration of PAH compounds in the soil was 18.71-1744.59 ng/g, and the concentration of six potential cancer-causing PAH materials was 6.54-695.94 ng/g. The highest concentration was in Songdo-dong. The PAH concentration in the direct exposure area near the complex was relatively high compared to the indirect exposure area.

Effects of Immersion Liquids Containing Citrus junos and Prunus mume Concentrate and High Hydrostatic Pressure on Shelf-life and Quality of Scomber japonicus during Refrigerated Storage (유자(Citrus junos), 매실(Prunus mume) 농축액을 첨가한 침지액과 초정수압의 병행처리가 고등어(Scomber japonicus)의 냉장 저장 중 저장성 및 품질에 미치는 영향)

  • Kang, Bo-Kyeong;Kim, Koth-Bong-Woo-Ri;Kim, Min-Ji;Bark, Si-Woo;Pak, Won-Min;Kim, Bo-Ram;Ahn, Na-Kyung;Choi, Yeon-Uk;Byun, Myung-Woo;Ahn, Dong-Hyun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.10
    • /
    • pp.1555-1564
    • /
    • 2014
  • This study investigated the effects of combined treatment of immersion liquids (adjusted pH 4.5 with Citrus junos concentrate (CL), pH 5.5 with Prunus mume concentrate (PL), or no pH adjustment, pH 6.5, control) and high hydrostatic pressure (HHP, 450 MPa) on shelf-life and quality of mackerel. In this study, we measured changes in viable cell counts, pH level, volatile basic nitrogen, thiobarbituric acid reactive substances, color analysis, volatile organic compounds, and sensory evaluation of mackerel at $4^{\circ}C$ for 20 days. CL/HHP and PL/HHP treatments reduced viable cell counts by 3 log cycles during storage compared to the control. Mackerel treated with CL/HHP and PL/HHP showed significantly lower TBARS and VBN levels as compared to the control. After combined treatment, lightness and whiteness increased but redness decreased. VOCs tests showed that contents of alcohol, acid, and ketones in mackerel fillet treated with CL/HHP and PL/HHP were relatively reduced. Especially, CL/HHP and PL/HHP suppressed production of sulfur. In the sensory evaluation, aroma, taste, salinity, hardness, and springiness of mackerel treated with combined HHP showed higher scores than the control. These results suggest that immersion liquids and HHP treatments may increase shelf-life of mackerel and maintain quality during storage at $4^{\circ}C$.

Measurement of Classroom Air Quality in large cities in summer (여름철 대도심 학교교실의 실내공기환경 측정연구)

  • Kim, Yun-Deok
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.63-74
    • /
    • 2007
  • Together with the concern about the indoor all quality as sick house syndrome, the Ministry of Environment announced "Indoor Air Quality Control Law for the Multi Purpose Facility," which made the interests to be focused in the urgent understanding of current condition and preparation of measures about the indoor air pollution. In Dec 2005, the law was revised to obligatorily notify the amount of Formaldehyde and Volatile Organic Compounds in the case of newly constructed apartments with more than 100 houses. School also have its own indoor air quality guideline, Indoor air quality in school is very important because, children who very weak to indoor pollutants reside long time in there. The purpose of this paper is to survey indoor air qualify in school by field measurement. Field measurements were performed in 11 schools which were selected from 3 major cities(Incheon, Dae-jeon, chuncheon) in korea, during July, 2004. Totally concentration of Indoor pollutants were determined in 27 classroom. Target air pollutants were TVOC, formaldehyde, dust, CO, CO2 and NO2. For the result of this investigation, Indoor air quality in classroom was very poor and it was found that some pollutants (TVOC, float bacteria) exceed the guideline.

Implementation of a Portable Electronic Nose System for Field Screening (필드 스크린을 위한 휴대용 전자코 시스템의 구현)

  • Byun, Hyung-Gi;Lee, Jun-Sub;Kim, Jeong-Do
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.41-46
    • /
    • 2004
  • There is currently much interest in the development of instruments that emulate the senses of humans. Increasingly, there is demand for mimicking the human sense of smell, which is a sophisticated chemosensory system. An electronic nose system is applicable to a large area of industries including environmental monitoring. We have designed a protable electronic nose system using an array of commercial chemical gas sensors for recognizing and analyzing the various odours. In this paper, we have implemented a portable electronic nose system using an array of gas sensors for recognizing and analyzing VOCs (Volatile Organic Compounds) in the field. The accuracy of a portable electronic nose system may be lower than an instrument such as GC/MS (Gas Chromatography/Mass Spectrometer). However, a portable electronic nose system could be used on the field and showed fast response to pollutants in the field. Several different algorithms for odours recognition were used such as BP (Back-Propagation) or LM-BP (Levenberq-Marquardt Back-Propagation). We applied RBF (Radial Basis Function) Network for recognition and quantifying of odours, which has simpler and faster compared to the previously used algorithms such as BP and LM-BP.

Control of relative humidity in the static bag emission test method by adding water and its effect on formaldehyde emission intensity (백을 이용한 정적 방출시험 방법에서 수분공급을 통한 상대습도조절과 포름알데하이드의 방출강도에 미치는 영향)

  • Park, Cheol-Soon;Yoo, Ji-Ho;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.282-289
    • /
    • 2011
  • Rapid screening method for the determination of the emissions of pollutants from vehicle interior parts and materials have been developed as ISO 12219-2 which is using bag and based on a static condition. The method was not controlled humidity in the test bag, so it is not suitable test method for formaldehyde emission test which is highly related to humidity condition. In this study, possibility of control humidity in the static test bag by adding extra water and the effect of humidity condition for formaldehyde emissions have been investigated. The relative humidity in the test bag was affected not only amount of water added also material of test bag and test specimen. The emission intensity of formaldehyde was increased according to increasing relative humidity in test bag. But excessively supplied water was condensed on the inner surface of test bag and surface of sample specimen that were sorption formaldehyde and were reduced its emission intensity.