• Title/Summary/Keyword: VLF 탐사

Search Result 12, Processing Time 0.025 seconds

Simple Interpretation of VLF Data (VLF 전자탐사 자료의 해석)

  • Kim Hee Joon;Nam Myung Jin;Song Yoonho;Suh Jung Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.184-190
    • /
    • 2005
  • We have attempted to give some physical into the factors that control the response of subsurface target to plane wave excitation at VLF (very low frequency) frequencies. Although the VLF technique has some serious disadvantages, such as a lack of penetration depth and limited frequencies, its advantages are also extremely important to have made it by far the most popular electromagnetic technique in current use. In the magnetic-field measurement mode these lightweight, relatively low-priced tools allow us to survey large areas rapidly and inexpensively, to locate and roughly define subsurface electrical conductors. When used in the electric-field mode the technique is, in simple environments, capable of quantitative interpretation and once again the speed and relative cheapness of these devices makes them a natural 'first electromagnetic tool ' to use in reconnaissance mapping.

Electrical and VLF EM Responses for Conductive Dipping Dyke (맥상 황화광체에 대한 전기 및 전자탐사 반응)

  • Yoo In-Kol
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.2
    • /
    • pp.110-115
    • /
    • 1998
  • Self-potential, VLF-EM and dipole-dipole resistivity methods have been widely used for exploration of conductive sulfide ore deposit, because of the convenience and low cost of field work and the reliability of their results. The geophysical responses for vein-type sulfide outcrop of Changkoom mine located in Bukwi-Myon, Jinan-Gun, Chollabuk-Do were investigated and compared with its drilling results. The geology around the survey area is composed of acidic volcanics and sediments of Yuchon Group. And sulfides bearing pyrite, pyrrotite, galena etc. are deposited in disseminated or vein type within acidic volcanics. Typical geophysical responses were detected from the above vein type ore body, respectively. From the shape and extent of S.P. anomaly, ore body is dipping westward and extending about 50 m. It is detected that the VLF EM response matching the outline of ore zone is considered as indication of dyke dipping westward. And also resistivity response indicating conductive dipping dyke is detected. From drilling results for outcrop and geophysical anomalies, the shape of ore body is vein type dipping about $70^{\circ}W$ and extending about 50 m.

  • PDF

Shallow Eelectrical Resistivity and VLF Profiling at Sangchon-ri Area along the Southern Par of Yangsan Fault (양산단층 남부 상천리 일대의 천부 전기비저항 및 VLF 탐사)

  • 경재복;한수형;조현주;김지수
    • The Journal of Engineering Geology
    • /
    • v.9 no.1
    • /
    • pp.59-68
    • /
    • 1999
  • To clarify the geological structure of Yangsan fault around Sangchon-ri in the southern part of Kyungsang Basin the resistivity (dipole-dipole profiling) and VLF surveys carried out on the four profiles, crossing the inferred trace of the fault. The resistivity contrast across the fault is clearly shown on the profiles: higher resistivity and lower resistivity on the east and west, respectively. It is most likely from the uplift of the granitic bedrock on the east park due to the strike-fault raulting with vertical movement. The zero-crossing points of VLF anomalies, associated with near-surface fracture zone, are found to well correlate with the resistivity boundaries from the dipole-dipole profiling. Consequently, southern segment of Yangsan fault (at Sangchon-ri area) is interpreted to be vertically developed strike-slip fault with a difference more than 10m depth of basement rock at both sides.

  • PDF

Frture mapping and deep-seated ground water exploration in the crystalline rocks by integrated geophysical techniques (종합적 물리탐사에 의한 파쇄대 및 심부 지하수 탐사)

  • 정승환;김정호;조인기;전정수
    • The Journal of Engineering Geology
    • /
    • v.2 no.2
    • /
    • pp.113-130
    • /
    • 1992
  • Groundwater in crystalline basement is controlled primarily by tectonic fractures. It is evident that the delineation of the heavily faulted area and/or fractures deeply developped should be considerable value in deep-seated low enthalphy geothermal water. Electrical and electromagnetic methods have effectively been employed to map hydraulic faults and shear zones for groundwater exploration. In this study VLi; dipoledipole resistivity, controlled source audio~frequency magneto-telluric(CSAMT) and magnetic methods were applied in the Bomun resort area, adjacent to Kyongju city, southeastern part of Korea. The integrated geophysical tools employed in this experiment can be manifested themselves as: 1. Magnetic high for granite intrusions which is more favorable for geothermal gradient increase in depth. 2. VLF cross-over trends for mapping linear shallow conductive fractures and shear zones. 3. Dipole-dipole resistivity distributions for the deep-seated(less than 500m in depth) fractures and shear zones. The dipole-dipole resistivity field data were inverted to the true resistivity distribution with two-dimensional automatic inversion program based on the finite-difference method. 4. CSAMT provides an efficient way of delineating fractures and fault zones if the depth is greater than about 500m.

  • PDF

Characteristics of the Fracture Distribution on the Granitic Rock by DC and VLF-EM Survey in the Northern Part of Yusong (유성북부 화강암지역에서 전기비저항탐사와 극저주파 전자탐사를 이용한 단열분포 특성)

  • 조성현;김천수;송무영
    • The Journal of Engineering Geology
    • /
    • v.9 no.1
    • /
    • pp.45-57
    • /
    • 1999
  • Groundwater flow in rock mass is controlled by the fractures developed in the area. So, the conductive fractures are very important for groundwater flow in crystalline rock. This study aims to find out the characteristics of the fracture distributed in granitic rock in the northern part of the Yusong area (latitude $36^{\circ}24'18"~36^{\circ}25'08",{\;}longitude{\;}127^{\circ}21'00"~127^{\circ}23'23"$). The electric and EM surveys were carried out in the site to delineate the fracture the fracture zones. Since geophysical survey provides non-unique solution, hydraulic data and dilling log data including BHTV scanning were used as complementary data to achieve the objective of this study. Electric survey(DC) arrays used are schlumberger and dipole-dipole arrays. VLF is used for EM survey. The main charcteristics of the fracture developed in the study aera are that fractures associated with basic dyke cut corss the main fracture zone in NNW and play an important role as hydraulic barrier. In trun, groundwater table in the upstream area is lower than that downstream area.

  • PDF

The SP/VLF Methodology to Confirm the Seawater Seepage Zone of the Embankment (방조제(防潮堤) 누수부위(漏水部位) 확인(確認)을 위한 SP/VLF 탐사법(探査法)의 적용성(適用性))

  • Cho, Jin-Dong;Jung, Hyun-Key;Chung, Seung-Hwan;Kim, Jung-Ho
    • Economic and Environmental Geology
    • /
    • v.29 no.5
    • /
    • pp.623-627
    • /
    • 1996
  • Combined SP/VLF surveys were carried out at tide embankment, Changgi-ri, Anmyeon-up, Chungcheongnamdo in order to confirm the seawater seepage zone of the embankment using the 128 Channels SP monitor system and VLF/Magnetometer system. These methods were successful in the detection of the seawater seepage zone. The self-potential method can give better resolution of the seepage zone than do VLF method.

  • PDF

Electromagnetic Survey in Korea (한국의 전자탐사 현황)

  • Cho, Dong-Heng
    • Economic and Environmental Geology
    • /
    • v.39 no.4 s.179
    • /
    • pp.427-440
    • /
    • 2006
  • Electromagnetic(EM) survey has been in use for over a half century as a standard routine for, mineral exploration in many parts of the world. But EM survey work and serious research effort were initiated in Korea only as late as in early 1980s, largely inspired by four pioneers who did their graduate studies in the U.S.A. in 1970s. Nevertheless domestic achievements in the field of EM survey are remarkable in the last two decades: the field operations and related interpretational skills appear to have reached a global standard, even compared with the most advanced in other countries, virtually in a whole spectrum of the method which includes magneto-tellurics(MT), Controlled Source Audio-frequency Magneto-tellurics(CSAMT), geomagnetic sounding, small loop survey systems, Very Low Frequency(VLF), Ground Penetrating Radar(GPR), time domain surveys, and noise analysis. Besides mineral exploration, EM survey has been applied in Korea to hydrogeology, geotechnical engineering, non-destructive investigation of structures, unexplored ordnance(UXO) investigation, environmental monitoring, and archaeological investigation as well. Now that original contributions of several Korean geophysicists are found even in new frontiers such as high-frequency EM survey, investigation in time-domain EM field for buried metal objects and structures, and also modem data inversion scheme, it is duly hoped that they make some technical breakthrough to unravel still entangled knots of EM survey method in a forseeable future.

A Study on the Structure of the Yangsan Fault In the southern part of Kyeongju (경주 남부지역의 양산단층의 구조에 관한 연구)

  • Kim, Yeonghwa;Lee, Kiehwa
    • Economic and Environmental Geology
    • /
    • v.20 no.4
    • /
    • pp.247-260
    • /
    • 1987
  • As a part of study on the structure of the Yangsan Fault, geological and VLF EM studies have been made in the fault area approximately between Kyeongju and Eonyang. The result provides comparatively clear information on the trace of the fault and extent of fracture zone as well as the structural characteristics of the Yangsan Fault area. The location of fault trace identified from this VLF EM study coincides well in general with that expected from geological information of the area. And the extent of fault fracture zone turn out to be characterized by U shaped low resistivity zone whose width increases from north to south.

  • PDF

Gravity, Magnetic and VLF explorations in the ubong industrial waste landfill, Pohang (포항 유봉산업 폐기물 매립지에서의 중력, 자력, VLF 탐사)

  • 권병두
    • Economic and Environmental Geology
    • /
    • v.32 no.2
    • /
    • pp.177-187
    • /
    • 1999
  • Gravity, magnetic and VLF surveys were conducted to investigat the structural stability and hazards associated with the Ubong landfill in Pohang City, which has been built to dump industrial wastes. In 1994, the collapse of a bank happened in the 6th landfill site due to sudden heavy rain, and a large quantity of waste materials flowed out to the nearby landfill sites, factories and roads. We used $10{\times}10m$ resolution DEM data for gravity reductions. The maximum variation of the terrain effect in the survey area is about 0.5 mgal and the terrain effect is large in the vicinity of bank boundary. The Bouguer gravity anomaly map shows the effect due to the variatino of thickness and type of waste materials. The small negative gravity anomaly increases from the 9th site to the 6th site. The small negative gravity anomaly of the 9th site reflects the relatively shallow dumping depth of average 14.5 m in this site and increased density of waste materials by the repeated stabilization process of soil overlaying. The 6th site is located at the center of the former valley and rainfall and groundwater are expected to flow from south-east to north-west. Therefore, considering the previous accident of mixing waste and bank materials at the north-west boundary of the landfill, there may be some environmental problems of leakage of contaminated water and bank stability. The complex inversion technique using Simulated annealing and Marquardt-Levenberg methods was applied to calculate three-dimensional density distribution from gravity data. In the case of 6th site, it is apparent that the landfill had been dumped in four sectors. However, most part of the 9th site and showed that high magnetic industrial wastes were concentrated in the 6th site. The result of magnetic survey showing low magnetic anomalies along the boundaries of two sites is similar to that of gravity data. The VLF data also reveals four divided sectors in the 6th site, and overall anomaly trend indicates the directio of former valley.

  • PDF

Gravity, Magnetic and VLF Explorations in the Seokdae Landfill, Pusan (부산시 석대 매립지에서의 중력, 자력, VLF탐사)

  • Kwon, Byung-Doo;Seo, Jung-Hee;Oh, Seok-Hoon
    • Economic and Environmental Geology
    • /
    • v.31 no.1
    • /
    • pp.59-68
    • /
    • 1998
  • Gravity, magnetic and VLF surveys were carried out to investigate the dimension, nature and stability of the waste materials filled in the Seokdae landfill, Pusan. The Seokdae landfill, which is located in a former valley, was used as a dump for mainly domestic-type waste materials for 6 years from 1987. The landfill site is classfied into A, B, C and D areas according to the sequence of dumping period. The Bouguer gravity anomaly map shows maximum variation of 3.1 mgals on the landfill and its general appearance has close relation with the thickness of waste filled. The local variation of anomaly, however, reflect the degree of compactness of waste materials which may be affected by the nature of waste and dumping time. In the case of area A, where dumping process was terminated at the very last stage, most part show negative anomaly compared to other areas. We think that the composition of the waste materials in the area A is high in leftover food and paper trash and they are still in uncompacted condition. In area B, the general trend of variation of gravity anomaly is appeared to be high anomaly in northern part and decrease to the southern part. This is well matched with the prelandfill topography of the landfill site. The southern part of area B is located in the center of valley and its present surface is comparatively rugged, which may be due to the differential settlement of deep burried waste. The thickness of waste in area C is relatively thin, but the gravity anomaly appears to be low. Considering the present condition of surface, it can be inferred that low density wastes such as leftover food were mainly filled in this area. Area D, as in the case of area B, shows gravity anomaly that has close relation with the prelandfill topography. Magnetic data show the variation of total field intensity varies in the range of 46600~51000 nT, and reach maximum anomaly of 4400 nT. The overall pattern of magnetic anomaly well reflects the distribution of magnetic materials in the landfill. The result of VLF survey reveals several low resistivity zones, which may serve as underground passages for contaminant flow, in the area C located near the small Village.

  • PDF