• Title/Summary/Keyword: V60

Search Result 3,703, Processing Time 0.031 seconds

60 GHz Low Noise Amplifier MMIC for IEEE802.15.3c WPAN System (IEEE802.15.3c WPAN 시스템을 위한 60 GHz 저잡음증폭기 MMIC)

  • Chang, Woo-Jin;Ji, Hong-Gu;Lim, Jong-Won;Ahn, Ho-Kyun;Kim, Hae-Cheon;Oh, Seung-Hyueb
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.227-228
    • /
    • 2006
  • In this paper, we introduce the design and fabrication of 60 GHz low noise amplifier MMIC for IEEE802.15.3c WPAN system. The 60 GHz LNA was designed using ETRI's $0.12{\mu}m$ PHEMT process. The PHEMT shows a peak transconductance ($G_{m,peak}$) of 500 mS/mm, a threshold voltage of -1.2 V, and a drain saturation current of 49 mA for 2 fingers and $100{\mu}m$ total gate width (2f100) at $V_{ds}$=2 V. The RF characteristics of the PHEMT show a cutoff frequency, $f_T$, of 97 GHz, and a maximum oscillation frequency, $f_{max}$, of 166 GHz. The performances of the fabricated 60 GHz LNA MMIC are operating frequency of $60.5{\sim}62.0\;GHz$, small signal gain ($S_{21}$) of $17.4{\sim}18.1\;dB$, gain flatness of 0.7 dB, an input reflection coefficient ($S_{11}$) of $-14{\sim}-3\;dB$, output reflection coefficient ($S_{22}$) of $-11{\sim}-5\;dB$ and noise figure (NF) of 4.5 dB at 60.75 GHz. The chip size of the amplifier MMIC was $3.8{\times}1.4\;mm^2$.

  • PDF

Evaluation of Extremely Low Frequency Magnetic Fields emission Level from High Voltage Transmission Lines (고압 송전선로에서 극저주파 자기장 영향평가 적용에 관한 연구)

  • Jung, Joon Sig;Choi, Sung Ho;Jeon, Hyung Jin;Kim, Yoon Shin;Hong, Seung Cheol
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.5
    • /
    • pp.353-363
    • /
    • 2014
  • The purpose of this study was to investigated the ELF-MF emission level of various environments such as 258 facilities near located to high voltage transmission lines and 120 high voltage transmission lines, 17 underground cable lines. In addition, ELF-MF reduction rate according to separation distance was calculated by using simulations. An appropriate separation distance showing below 4mG was at least 70m. In the case of the appropriate separation distance for 120 high voltage transmission lines, 154kV required 20m of separation distance and 345kV required 60m of separation distance. The simulation results showed that the appropriate separation distance showing below 4mG was 40m and 60m for overhead 154kV and 345kV respectively. To adjust the worst conditions considering the aspects of environmental impact assessment study and the electric power currents that will increase in the future, the appropriate minimum separation distance for HVTL is judged to be above 70m in this study. Thus, there is a need to establish the greenbelt or buffer zone within 70m so as to create an environment in which the receptors are not exposed and thereby eliminate the risk factors of ELF-MF against humans.

Design and Reliability Evaluation of 5-V output AC-DC Power Supply Module for Electronic Home Appliances (가전기기용 직류전원 모듈 설계 및 신뢰성 특성 해석)

  • Mo, Young-Sea;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.504-510
    • /
    • 2017
  • This paper presents an AC-DC power module design and evaluates its efficiency and reliability when used for electronics appliances. This power module consists of a PWM control IC, power MOSFETs, a transformer and several passive devices. The module was tested at an input voltage of 220V (RMS) (frequency 60 Hz). A test was conducted in order to evaluate the operation and power efficiency of the module, as well as the reliability of its protection functions, such as its over-current protection (OVP), overvoltage protection (OVP) and electromagnetic interference (EMI) properties. Especially, we evaluated the thermal shut-down protection (TSP) function in order to assure the operation of the module under high temperature conditions. The efficiency and reliability measurement results showed that at an output voltage of 5 V, the module had a ripple voltage of 200 mV, power efficiency of 73 % and maximum temperature of $80^{\circ}C$ and it had the ability to withstand a stimulus of high input voltage of 4.2 kV during 60 seconds.

Factors Affecting Electrofusion of Plant Protoplasts (식물 Protoplast의 전기자극 융합에 관여하는 인자)

  • Han, Sung-Kyu;U, Zang-Kual;Kang, Soon-Suon;Riu, Key-Zung;Oh, Sung-Gug
    • Applied Biological Chemistry
    • /
    • v.33 no.1
    • /
    • pp.93-100
    • /
    • 1990
  • The optimum conditions of electric stimulation for electrofusion of protoplasts of petunia, carrot and soybean, and the effects of calcium, magnesium, protease, trypsin, triton X-100, concanavalin A, dimethyl sulfoxide(DMSO), glycerol monooleate and spermine on fusion frequency and/or viability of petunia protoplast were investigated. The optimum frequencies(Hz)-amplitudes(V/cm) of AC Pulse for protoplast pearl-chain formation were 10 kHz-20 V/cm and 1 MHz-60 V/cm for petunia, 100 kHz-40 V/cm and $1\;MHz-40{\sim}60\;V/cm$ for carrot, and $1\;MHz-40{\sim}80\;V/cm$ for soybean, respectively. The optimum condition of DC pulse treatment at the 1 MHz-60 V/cm-15sec treatment of AC for electrofusion of petunia protoplasts was 2.5 kV/cm-40 sec, and under this condition the fusion frequency and viability of protoplasts were 45 % and 10 %, respectively, Both of the protoplasts of carrot and soybean were not fused under the AC and DC conditions tested in this experiment. The electrofusion of petunia protoplasts was stimulated by calcium, and the fusion frequency and the viability of the protoplasts were 43 % and 11 % , respectively at the calcium concentration of 140 mM. Although fusion frequency was not affected by magnesium only, magnesium stimulated fusion frequency in the presence of calcium, and the viability and fusion frequency of petunia protoplasts were 45 % and 13 %, respectively, at 140 mM of magnesium-140 mM of calcium. The relative fusion frequencies of petunia protoplasts to the controls were increased by 2.4, 2.1, 1.6, 1.4, 1.8, 1.5 and 2.2 folds, respectively, by the treatments of protease, trypsin, triton X-100, concanavalin A, DMSO, glycerol monooleate, and spermine. The viabilities of petunia protoplasts were decreased by these substances.

  • PDF

THE EFFECT OF IRRADIATION MODES ON POLYMERIZATION AND MICROLEAKAGE OF COMPOSITE RESIN (광조사 방식이 복합레진의 중합과 누출에 미치는 영향)

  • Park, Jong-Jin;Park, Jeong-Won;Park, Sung-Ho;Park, Ju-Myong;Kwon, Tae-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.158-174
    • /
    • 2002
  • The aim of this study was to investigate the effect of light irradiation modes on polymerization shrinkage, degree of cure and microleakage of a composite resin. VIP$^{TM}$ (Bisco Dental Products, Schaumburg, IL, USA) and Optilux 501$^{TM}$ (Demetron/Kerr, Danbury, CT, USA) were used for curing Filtek$^{TM}$ Z-250 (3M Dental Products, St. Paul., MN, USA) composite resin using following irradiation modes: VIP$^{TM}$ (Bisco) 200mW/$\textrm{cm}^2$ (V2), 400mW/$\textrm{cm}^2$ (V4), 600mW/$\textrm{cm}^2$ (V6), Pulse-delay (200 mW/$\textrm{cm}^2$ 3 seconds, 5 minutes wait, 600mW/$\textrm{cm}^2$ 30seconds, VPD) and Optilux 501$^{TM}$ (Demetron/Kerr) C-mode (OC), R-mode (OR). Linear polymerization shrinkage of the composite specimens were measured using Linometer (R&B, Daejeon, Korea) for 90 seconds for V2, V4, V6, OC, OR groups and for up to 363 seconds for VPD group (n=10, each). Degree of conversion was measured using FTIR spectrometer (IFS 120 HR, Bruker Karlsruhe, Germany) at the bottom surface of 2 mm thick composite specimens V2, Y4, V6, OC groups were measured separately at five irradiation times (5, 10, 20, 40, 60 seconds) and OR, VPD groups were measured in the above mentioned irradiation modes (n=5 each). Microhardness was measured using Digital microhardness tester (FM7, Future-Tech Co., Tokyo, Japan) at the top and bottom surfaces of 2mm thick composite specimens after exposure to the same irradiation modes as the test of degree of conversion(n=3, each). For the microleakage test, class V cavities were prepared on the distal surface of the ninety extracted human third molars. The cavities were restored with one of the following irradiation modes : V2/60 seconds, V4/40 seconds, V6/30 seconds, VPD , OC and OR. Microleakage was assessed by dye penetration along enamel and dentin margins of cavities. Mean polymerization shrinkage, mean degree of conversion and mean microhardness values for all groups at each time were analyzed using one-way ANOVA and Duncan's multiple range test, and using chi-square test far microleakage values. The results were as follows : . Polymerization shrinkage was increased with higher light intensity in groups using VIP$^{TM}$ (Bisco) : the highest with 600mW/$\textrm{cm}^2$, followed by Pulse-delay, 400mW/$\textrm{cm}^2$ and 200mW/$\textrm{cm}^2$ groups, The degree of polymerization shrinkage was higher with Continuous mode than with Ramp mode in groups using Optilux 501$^{TM}$ (Demetron/Kerr). . Degree of conversion and microhardness values were higher with higher light intensity. The final degree of conversion was in the range of 44.7 to 54.98% and the final microhardness value in the range of 34.10 to 56.30. . Microleakage was greater in dentin margin than in enamel margin. Higher light intensity showed more microleakage in dentin margin in groups using VIP$^{TM}$ (Bisco). The microleakage was the lowest with Continuous mode in enamel margin and with Ramp mode in dentin margin when Optilux 501$^{TM}$ (Demetron/Kerr) was used.

A study on the Development of Transducer Detecting Infrasonic (초저주파를 검출하는 변환기의 개발에 대한 연구)

  • 이성백;김재환;강영창;이준웅
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.6 no.1
    • /
    • pp.45-50
    • /
    • 1981
  • Infrasonic transducer made with dielectric materials, such as polytetrafluoroethyleme(PTFE)film. The experimental result obtained that the response is within $\pm$1.5dB from 0.1Hz to 7KHz, and that sensitivities of typical transducer are fixed -60dB. The time constant of the transducer at room temperature is over 60 years, and the activation energy of the value of 1.1eV at 343K acquired. This transducer can have application to high-quality communication system, seismological observation etc.

  • PDF

Development of 60KV Pulsed Power Supply using IGBT Stacks (IGBT 직렬구동에 의한 60KV 펄스 전원장치 개발)

  • Ryoo, Hong-Je;Kim, Jong-Soo;Rim, Geun-Hie;Goussev, G.I.;Sytykh, D.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.88-99
    • /
    • 2007
  • In this paper, a novel new pulse power generator based on IGBT stacks is proposed for pulse power application. Because it can generate up to 60kV pulse output voltage without any step- up transformer or pulse forming network, it has advantages of fast rising time, easiness of pulse width variation and rectangular pulse shape. Proposed scheme consists of series connected 9 power stages to generate maximum 60kV output pulse and one series resonant power inverter to charge DC capacitor voltage. Each power stages are configured as 8 series connected power cells and each power cell generates up to 850VDC pulse. Finally pulse output voltage is applied using total 72 series connected IGBTs. To reduce component for gate power supply, a simple and robust gate drive circuit is proposed. For gating signal synchronization, full bridge invertor and pulse transformer generates on-off signals of IGBT gating with gate power simultaneously and it has very good characteristics of short circuit protection.

Implementation of the 60W DC Characteristic Measurement System for Semiconductor Devices (60W 출력을 가지는 반도체 소자의 직류 특성 측정시스템의 구현)

  • Choi, In-Kyu; Choi, Chang;Han, Hye-Jin;Park, Jong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.34-37
    • /
    • 2001
  • In this paper, we designed and implemented the 60W DC characteristic measurement system for semiconductor devices. The proposed system is composed of 2 SMU(Source and Measure Unit)s, 2 HPU(High power Unit)s, 2VSU(Voltage Source Unit)s, and 2 VMU(Voltage Measurement Unit)s. HPU can source/measure voltage from -200V to 200V and source/measure current from -3A to 3A within 60W. Experimental results show that the implemented system can measure the power devices such as power BJT, regulator IC, and voltage detector.

  • PDF

Electrical and Optical Characteristics of X/40/60 PLZT Thin Films by Sol-Gel Processing (Sol-Gel 법에 의한 X/40/60 PLZT 박막의 전기 및 광학 특성)

  • 이진욱;마석범;강종윤;장낙원;박정흠
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.139-142
    • /
    • 1996
  • X/40/60 PLZT thin films were prepared by sol-gel processing and annealed by rapid thermal annealing(RTA). X/40/60 PLZT thin films were crystallized at 75$0^{\circ}C$ for 5min by RTA. Hysteresis curves were narrowed and coercive field was decreased from 50kV/cm to 31.2 kV/cm and remnant polarization was also decreased from 14.3$\mu$C/$\textrm{cm}^2$ to 6.72$\mu$C/$\textrm{cm}^2$ as La mol% increased. Dielectric constanat and optical transmittance were increased with increasing La mol%.

  • PDF