• Title/Summary/Keyword: V2C

Search Result 9,803, Processing Time 0.044 seconds

Piezoelectric Characteristics of Lead-Free 0.74(Bi0.5Na0.5)TiO3-0.26SrTiO3 Ceramics According to Calcination Temperature (무연 0.74(Bi0.5Na0.5)TiO3-0.26SrTiO3 압전 세라믹스의 하소온도 변화에 따른 전기적 특성 변화)

  • Kim, Seong-Hyun;Lee, Sang-Hun;Han, Hyoung-Su;Lee, Jae-Shin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.1
    • /
    • pp.35-39
    • /
    • 2019
  • In this study, we investigated the optimum calcination temperature of lead-free $0.74(Bi_{0.5}Na_{0.5})TiO_3-0.26SrTiO_3$(BNST) piezoelectric ceramics by analyzing the crystal structure, dielectric properties, and electric field-induced strain behavior. BNST ceramics prepared by conventional solid-state reaction methods at various calcination temperatures according to the industrial standard. All samples of BNST ceramics were subsequently sintered at $1,175^{\circ}C$ for 2 h. Crystal structure classification of the ceramics showed a single perovskite phase, with no second phase detectable for the samples calcined at $750^{\circ}C$ or higher. BNST samples calcined at $850^{\circ}C$ exhibited the most optimal values for itsand the common physical parameters of $density=5.518g/cm^3$, ${\varepsilon}=1,871.837$, $tan{\delta}=0.047$, and ${d_{33}}^*=874pm/V$.

Electron Beam Evaporated ITO Transparent Electrode for Highly Efficiency GaN-based Light Emitting Diode (고효율 질화갈륨계 발광 다이오드용 전자선 증착 ITO 투명 전도 전극 연구)

  • Seo, Jae Won;Oh, Hwa Sub;Kang, Ki Man;Moon, Seong Min;Kwak, Joon Seop;Lee, Kuk Hwe;Lee, Woo Hyun;Park, Young Ho;Park, Hae Sung
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.10
    • /
    • pp.683-690
    • /
    • 2008
  • In order to develop transparent electrodes for high efficiency GaN-based light emitting diodes (LEDs), the electrical and optical properties of the electron beam evaporated ITO contacts have been investigated as a function of the deposition temperature and flow rate of oxygen during the deposition. As the deposition temperature increases from $140^{\circ}C$ to $220^{\circ}C$, the resistivity of the ITO films decreases slightly from $4.0{\times}10^{-4}{\Omega}cm$ to $3.3{\times}10^{-4}{\Omega}cm$, meanwhile the transmittance of the ITO films significantly increases from 67% to 88% at the wavelength of 470 nm. When the flow rate of oxygen during the deposition increases from 2 sccm to 4 sccm, the resistivity of the ITO films increases from $3.6{\times}10^{-4}{\Omega}cm$ to $7.4{\times}10^{-4}{\Omega}cm$, meanwhile the transmittance of the ITO films increases from 86% to 99% at 470 nm. Blue LEDs fabricated with the electron beam evaporated ITO electrode show that the ITO films deposited at $200^{\circ}C$ and 3 sccm of the oxygen flow rate give a low forward-bias voltage of 3.55 V at injection current of 20 mA with a highest output power.

Two novel mutations in ALDH18A1 and SPG11 genes found by whole-exome sequencing in spastic paraplegia disease patients in Iran

  • Komachali, Sajad Rafiee;Siahpoosh, Zakieh;Salehi, Mansoor
    • Genomics & Informatics
    • /
    • v.20 no.3
    • /
    • pp.30.1-30.9
    • /
    • 2022
  • Hereditary spastic paraplegia is a not common inherited neurological disorder with heterogeneous clinical expressions. ALDH18A1 (located on 10q24.1) gene-related spastic paraplegias (SPG9A and SPG9B) are rare metabolic disorders caused by dominant and recessive mutations that have been found recently. Autosomal recessive hereditary spastic paraplegia is a common and clinical type of familial spastic paraplegia linked to the SPG11 locus (locates on 15q21.1). There are different symptoms of spastic paraplegia, such as muscle atrophy, moderate mental retardation, short stature, balance problem, and lower limb weakness. Our first proband involves a 45 years old man and our second proband involves a 20 years old woman both are affected by spastic paraplegia disease. Genomic DNA was extracted from the peripheral blood of the patients, their parents, and their siblings using a filter-based methodology and quantified and used for molecular analysis and sequencing. Sequencing libraries were generated using Agilent SureSelect Human All ExonV7 kit, and the qualified libraries are fed into NovaSeq 6000 Illumina sequencers. Sanger sequencing was performed by an ABI prism 3730 sequencer. Here, for the first time, we report two cases, the first one which contains likely pathogenic NM_002860: c.475C>T: p.R159X mutation of the ALDH18A1 and the second one has likely pathogenic NM_001160227.2: c.5454dupA: p.Glu1819Argfs Ter11 mutation of the SPG11 gene and also was identified by the whole-exome sequencing and confirmed by Sanger sequencing. Our aim with this study was to confirm that these two novel variants are direct causes of spastic paraplegia.

Dose distribution at junctional area abutting X-ray and electron fields (X-선과 전자선의 인접조사에서 접합 조사면에서의 선량분포)

  • Yang, Kwang-Mo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.91-99
    • /
    • 2004
  • Purpose : For the head and neck radiotherapy, abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Materials and methods : Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom according to depths(0 cm, 1.5 cm, 3 cm, 5 cm). 6 MV X-ray and 9 MeV electron(1Gy) were exposes to 8cm depth and surface(SSD 100cm) of phantom. The dose distribution to the junction line between photon($10cm{\times}10cm$ field with block) and electron($15cm{\times}15cm$ field with block) fields was also measured according to depths(0 cm, 0.5 1.5 cm, 3 cm, 5 cm). Results : At the junction line between photon and electron fields, the hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to $6\%$ of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was $4.5-30\%$ of reference dose in the electron field. Conclusion : When we make use of abutting photon field with electron field for the treatment of head and neck cancer we should consider the hot and cold dose area in the junction of photon and electron field according to location of tumor.

  • PDF

Studies on the Improvement of the Fishing Efficiency of Purse Seine in the Sea Area of Cheju Island -The Changes of Seine Volume and Tension in the Purseline During Pursing- (제주도 주변해역 선망의 어획성능 향상에 관한 연구 -짐줄 체결 중 선망의 용적과 짐줄의 장력 변화 -)

  • 김석종
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.2
    • /
    • pp.93-101
    • /
    • 1999
  • A simple experimental method was used in an attempt to realize the elevation of the fishing ability of purse seine in the sea area of Cheju Island, the changes of seine volume and tension in the purseline during pursing. Experiments carried out on the six types simplified reduced model seines which were made of knotless nettings. The nettings were woven in different leg length 4.3, 5.0, 5.5, 6.0, 6.6 and 7.7mm of polyester 28 tex two threads two-ply twine, and each of the seines were named I, II, III, IV, V and Ⅵ seine. Dimension of seine models were 450cm for corkline and 85cmfor seine depth, each seines rigged up 160g of float for a floatline and 50g (underwater weight) of lead for a leadline. These model purse seines were made of the scale of 1/200 of its full scale, a 120 ton in the near sea of Cheju Island. Designing and testing for the model purse seines were based on the Tauti's law. Experiments were measured in the observation channel of a flume tank at the static conditions set up shooting and pursing equipments. Motion of purse seine during purse line was recorded by the two sets video camera for VTR which were placed in top and front of the model seine. The reading coordinate of seine volume carried out by the video digitization system, disk data for the purseline tension. An analysis were performed on the changes seine volume and tension in the purseline during pursing. The results obtained were as follows: 1. The seine volume during pursing was largest for Ⅵ seine with smallest d/l followed by V, IV, III, II and I seines, and tension in the purseline was small. 2. Seine volume during pursing can be expressed by the following equation; CVt=l-EXP[{2.79 (d/l)+0.35}t-33.37 (d/l) + 0.57] Where CVt is volume ratio, d is twine diameter, l is leg length and t is pursing time (sec). 3. Tension in the purse line during pursing can be expressed by the following equation; T= 1- EXP {0.57t + 13.36 (d/l)+2.97} Where T is tension (kg) in the purseline during pursing.

  • PDF

Effect of Pancreatic Polypeptide Family on Cardiovascular Muscle Contractility: 1. Interactions with cyclic nucleotide activators and $K^+$ channel openers in canine cerebral arteries (Pancreatic Polypeptide Family의 심혈관계 근육 수축성에 대한 약리학적 작용: I. 개의 뇌혈관에서 cyclic nucleotide활성제와 칼륨통로개방제와의 상호작용)

  • Kim, Won-Joon;Lee, Kwang-Youn;Ha, Jeoung-Hee;Kwon, Oh-Cheol
    • The Korean Journal of Pharmacology
    • /
    • v.28 no.2
    • /
    • pp.147-162
    • /
    • 1992
  • The objectives of the present experiments were to characterize the effects of the peptides belonging to the pancreatic polypeptide family on the contractility of cerebral arteries and to observe the interactions of these peptides with the cyclic nucleotide activators and the potassium channel openers. Dogs of either sex, $20{\sim}30\;Kg$ in weight, were sacrificed. Basilar and middle cerebral arteries from brain were isolated and prepared for myography in the PSS equilibrated with 95% $O_2$ and 5% $CO_2$ at $37^{\circ}C$. The endothelial cells of the spiral strips were removed by CHAPS solution (0.3% w/v, 15 seconds). 1. PP, PYY and NPY contracted the arterial strips concentration-dependently with a rank order of potency of PYY>NPY>PP. These peptides were 20 to 200 times more potent than norepinephrine, and only PYY showed a greater potency than 5-HT. 2. Cyclic nucleotide activators, forskolin (for cAMP) and sodium nitroprusside (for cGMP) reduced the basal tone and inhibited the PP-, PYY- and NPY- induced contractions by concentration-dependent manners. Forskolin was more potent in reducing basal tone than sodium nitroprusside. 3. Potassium channel openers, RP 49356, P 1060 and BRL 38227 reduced the basal tone concentration-dependently and tended to inhibit the PP-, PYY- and NPY- induced contractions. Notably, BRL 38227 with low concentration $(0.1\;{\mu}M)$ enhanced the contractions induced by those peptides while P 1060 inhibited the contractions concentration-dependently. 4. The combinations of the cyclic nucleotide activators and the potassium channel openers were slightly additive in reducing the basal tone. P 1060 and BRL 38227 enhanced the relaxant effect of sodium nitroprusside significantly. On the PYY-induced contration $(0.1\;{\mu}M)$, $K^+$ channel openers tended to inhibit the inhibitory actions of forskolin and sodium nitroprusside. P 1060 and BRL 38227 antagonized the inhibitory action of sodium nitroprusside significantly. The results of the present study may be summarized that in canine cerebral arteries, not only NPY but also PYY may play a role in a cerebrovascular spasm, and intracellular concentration of either cAMP or cGMP may be involved in the mechanism of vasoconstrictive actions of these peptides, which may be affected either positively or negatively by a $K^+$ channel opener.

  • PDF

Determination of Hg22+ Ions Using a Modified Glassy Carbon Electrode with 2,2':6':2''-Terpyridine

  • Kong, Young-Tae;Bae, Yun-Jung;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.2
    • /
    • pp.346-350
    • /
    • 2002
  • A glassy carbon electrode (GCE) modified with 2,2':6':2”-terpyridine (2,2':6':2”-TPR) using a spin coating method was applied for the highly selective and sensitive analysis of a trace amount of $Hg_2^{2+}$ ions. Various experimental parameters, which influenced the response of the 2,2':6':2”-TPR modified electrode to $Hg_2^{2+}$ ions, were optimized. The linear sweep and differential pulse voltammograms for the 2,2':6':2”-TPR modified electrode deposited with Hg show a well-defined anodic peak at +0.65 V (vs. Ag|AgCl). After a 25 min preconcentration time in an $Hg_2^{2+}$ ion solution (0.1 M acetate buffer, pH 5.0), differential pulse voltammetry(DPV) with 2,2':6':2”-TPR modified electrode shows a linear response between $1.0\;{\times}\;10^{-6}M\;and\;2.0\;{\times}\;10^{-7}M$. The least-square treatment of these data produce an equation of I[${\mu}A$] = 0.031 + 0.005C with r = 0.980(n = 5). The detection limit of this electrode with linear sweep voltammetry and differential pulse anodic voltammetry were $2.0\;{\times}\;10^{-6}M\;and\;8.0\;{\times}\;10^{-8}M$, respectively. The presence of Pb, Fe, Cd, Ti, Ni, Co, Mg, Al, Mn, and Zn did not interfere in the analysis of the $Hg_2^{2+}$ ion. The 2,2':6':2”-TPR modified GCE has been successfully applied in determination trace amounts of Hg in a human urine sample.

A Study on Surface Characteristics and Stability of Implants Treated with Anodic Oxidation and Fluoride Incorporation (양극 산화와 불소 화합물로 처리한 임플랜트의 표면 특성 및 골유착 안정성에 관한 연구)

  • Lim, Jae-Bin;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.349-365
    • /
    • 2006
  • State of problem : A number of investigation about increase of surface area via various surface treatments and modification of surface constituent have been carried out. Purpose : The surface characteristics and stability of implants treated with anodic oxidation, fluoride ion incorporation, and groups treated with both methods were evaluated. Material and method : Specimens were divided into six groups, group 1 was the control group with machined surface implants, groups 2 and 3 were anodic oxidized implants (group 2 was treated with 1M $H_2SO_4$ and 185V, group 3 was treated with 0.25M $H_2SO_4$ and $H_3PO_4$ and 300V). Groups 4, 5 and 6 were treated with fluoride. Group 4 was machined implants treated with 0.1% HF, and groups 5 and 6 were groups 2 and 3 treated with 10% NaF respectively. Using variable methods, implant surface characteristics were observed, and the implant stability was evaluated on rabbit tibia at 0, 4, 8 and 12 weeks. Result : 1. In comparison of the surface characteristics of anodic oxidized groups, group 2 displayed delicate and uniform oxidation layer with small pore size containing Ti, C, O and showed mainly rutile, but group 3 displayed large pore size and irregular oxidation layer with many crators. 2. In comparison of the surface characteristics of fluoride treated groups 4, 5, 6 and non-fluoride treated groups 1, 2, 3, the configurations were similar but the fluoride treated groups displayed rougher surfaces and composition analysis revealed fluoride in groups 4, 5, 6. 3. The fluoride incorporated anodic oxidized groups showed the highest resonance frequency values and removal torque values, and the values decreased in the order of anodic oxidized groups, fluoride treated group, control group. 4. According to implant stability tests, group 2 and 3 showed significantly higher values than the control group (P<.05). The fluoride treated groups showed relatively higher values than the non fluoride treated groups and there were significant difference between group 4 and group 1 (P<.05). Conclusion : From the results above, it can be considered that the anodic oxidation method is an effective method to increase initial bone stability and osseointegration and fluoride containing implant surfaces enhance new bone formation. Implants containing both of these methods should increase osseointegration, and reduce the healing period.

Characteristics and Fabrication of Micro Gas Sensor with Single Electrode (단일전극을 가진 마이크로 가스센서의 제작 및 특성)

  • Song, Kap-Duk;Bang, Yeung-Il;Lee, Sang-Mun;Lee, Yun-Su;Choi, Nak-Jin;Joo, Byung-Su;Seo, Moo-Gyo;Huh, Jeung-Soo;Lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.350-357
    • /
    • 2002
  • Micro gas sensor with single electrode was proposed for improving stability and sensitivity. Generally, metal oxide gas sensors have two electrodes for heating and sensing. This fabricated new type sensor have only a single electrode by forming a sensing material onto heating electrode. Pt as a heating and sensing electrode was sputtered on glass substrate and a $SnO_2$ sensing material was thermally evaporated on Pt electrode. $SnO_2$ was patterned by lift-off process and then thermally oxidized in $O_2$ condition for 1 hr., $600^{\circ}C$. The size of fabricated sensor was $1.9{\times}2.1\;mm^2$. As a result of CO gas sensing characteristics, this sensor showed 100 mV change for 1,000 ppm and linearity for wide range($0{\sim}10,000\;ppm$) of gas concentrations. And the sensor shows a good recovery characteristics of 1% deviation compared to initial resistance.

Myo-inositol increases the plating efficiency of protoplast derived from cotyledon of cabbage (Brassica oleracea var. capitata)

  • Jie, Eun-Yee;Kim, Suk-Weon;Jang, Hye-Rim;In, Dong-Su;Liu, Jang-Ryol
    • Journal of Plant Biotechnology
    • /
    • v.38 no.1
    • /
    • pp.69-76
    • /
    • 2011
  • This study describes the effect of myo-inositol on sustained cell division and plant regeneration from cotyledon-derived protoplast of cabbage (Brassica oleracea var. capitata). Freshly isolated protoplasts were cultured in modified Murashige and Skoog (MS) medium removed ammonia ions and containing $0.4\;mg\;l^{-1}$ thiamine HCl, $100\;mg\;l^{-1}$ myo-inositol, $2\;mgl^{-1}$ 2,4-D, $0.5\;mgl^{-1}$ BA, $30\;gl^{-1}$ sucrose and several concentrations of myo-inositol (2, 4, 6, 8, 10% (w/v)) as an osmotic stabilizer. After 3 weeks of culture in the dark at $25^{\circ}C$, the plating efficiency of cabbage protoplasts reached to $22.5{\pm}2.9%$ when cultured in modified MS medium supplemented with $2\;mgl^{-1}$ 2,4-D, $0.5\;mgl^{-1}$ BA, $30\;gl^{-1}$ sucrose and 8% (w/v) of myo-inositol at a density of $2{\times}10^5$ protoplasts/ml. Rapidly growing cell colonies after 3 weeks of culture were transferred to the same culture medium removed osmoticum. To induce shoot regeneration from calluses, calluses with about 2 mm in diameter were transferred to the MS medium containing $2\;mgl^{-1}$ BA and $0.5\;mgl^{-1}$ NAA. After further three weeks of incubation onto the medium in the light, green shoots were formed on the surface of calluses at a frequency of 30%. Upon transfer to half-strength MS basal medium, roots were formed onto the bottom of regenerated shoots without auxin treatments. These regenerated plantlets were successfully acclimatized to soil transfer, grown to normal mature plants. The cabbage protoplast culture system established in this study could be applied for production of somatic hybrids or cybrids by asymmetric protoplast fusion and mass proliferation of elite somatic clones of cabbage.