• Title/Summary/Keyword: V-sim

Search Result 2,753, Processing Time 0.03 seconds

Terbia Addition Effects on Accelerated aging Characteristics of (Pr, Co, Cr)-doped ZnO Varistors ((Pr, Co, Cr)-doped ZnO 바리스터의 가속열화특성에 테르비아 첨가효과)

  • Nahm, Choon-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.6
    • /
    • pp.508-513
    • /
    • 2007
  • The electrical properties and stability of $ZnO-Pr_6O_{11}-CoO-Cr_2O_3-based$ varistors were investigated for different $Tb_4O_{11}$ amounts in the range of $0{\sim}1.0\;mol%$. As the $Tb_4O_{11}$ amount increased, the sintered density increased in the range of $99.1{\sim}101.1%$ of theoretical density and the average grain size decreased in the range of $7.7{\sim}4.8{\mu}m$. The varistor voltage increased in the range of $280.9{\sim}715.8V/mm$ and the nonlinear coefficient increased in the range of $26.4{\sim}44.4$ with the increased of $Tb_4O_{11}$ amount. The 0.25 mol% $Tb_4O_{11}$-doped varistors exhibited the high electrical stability, with -0.1% in variation rate of varistor voltage, -0.7% in variation rate of nonlinear coefficient, and +17.4% in variation rate of leakage current for specified dc accelerated aging stress of $0.95V_{1mA}/150^{\circ}C/24h$.

Effects of V on the Formation of Ti-Nb-V Cabonitrides and Mechanical Properties in Low Carbon HSLA Steels (저탄소.저합금강의 Ti-Nb-V 복합 탄질화물 형성 및 기계적 특성에 미치는 V 첨가의 효과)

  • Kang, J.S.;Kim, D.J.;Park, C.G.
    • Transactions of Materials Processing
    • /
    • v.15 no.8 s.89
    • /
    • pp.581-585
    • /
    • 2006
  • Effects of V on both the formation of Ti-Nb-V carbonitrides and mechanical properties of Ti-Nb bearing low carbon HSLA steels were investigated. Hot rolling process was simulated by using Gleeble 3500 system with the steels containing three different levels of V ($0{\sim}0.1wt.%$). Vanadium precipitated as Ti-Nb-V carbonitrides at austenite region but it did not precipitate as VC during austenite to acicular ferrite or bainitic ferrite phase transformation. As V content increased, the amount of Nb precipitates was decreased but the average size of Ti-Nb-V carbonitrides was increased due to larger diffusivity of V than that of Nb. Coarsened Ti-Nb-V carbonitrides could act as heterogeneous nucleation site during ${\gamma}{\rightarrow}{\alpha}$ phase transformation, thus, acicular ferrite transformation was promoted as V content increased, resulting in increase of upper shelf energy.

Aerodynamic Characteristics of Basic Airfoils for Agricultural Helicopter using Wind-tunnel Test and CFD Simulation (풍동실험과 CFD 시뮬레이션을 이용한 농용 헬리콥터 기본 익형의 공력특성 고찰)

  • Won, Yong Sik;Koo, Young Mo;Haider, B.A.;Sohn, Chang Hyun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.54-54
    • /
    • 2017
  • 본 연구는 무인 헬리콥터의 양력을 개선하기 위한 기초 단계로서 V1505A 및 V2008B 기본 두 익형의 400 mm 블레이드 섹션에 해당하는 모델에 대한 풍동실험을 실시하여 양력, 항력 및 동력특성을 분석하고 CFD 시뮬레이션의 결과와 비교하고 검증하였다. 시뮬레이션은 풍동 실험과 유사하게 설정하기 위하여 400 mm 블레이드 섹션의 양 끝을 벽으로 제한하여 3차원 와류현상을 억제하여 모델을 구성하였고, 시뮬레이션의 결과와 비교하여 모델을 검증하였다. 사용된 모델은 로터로부터 $Re=0.32{\times}10^6$ 영역까지는 aminar 모델을 사용하였으며, 그 이후 영역역(>$Re=0.32{\times}10^6$)은 양력 및 저항의 급격한 변화를 올바로 포착할 수 있다는 S-A 모델을 적용하여 확장하였다. 시뮬레이션의 격자는 유동 현상에 있어 박리로 야기된 와류 현상을 관찰하기 위하여 익형 주변에 접하는 부분에 격자를 집중시켰다. 시뮬레이션 방법은 유속은 36~141 m/s 까지 5 수준으로 하였으며, 받음각은 $0{\sim}16^{\circ}$로 7 수준으로 변화 시키면서 공력계수 및 동력을 분석하였다. 양력분석에 있어 익형 V1505A에 비해 익형 V2008B의 특성이 우수하였으나, 익형 V1505A는 실속 이후 양력이 급격히 떨어지지 않고 유지되는 특성을 보였다. 익형 V2008B는 낮은 받음각에서 높은 공력과 낮은 항력을 나타냈다. 동력 분석 결과로 익형 V1505A의 유도동력은 총 동력의 56~72%를 차지하고, 형상동력은 총 동력의 27~43%를 차지하였다. 익형 V2008B는 유도동력은 총 동력의 66~81%를 차지하고, 형상동력은 총 동력의 18~33%를 차지하였다. 익형 V2008B이 익형 V1505A보다 유도동력은 크며, 형상동력은 적게 나와 상대적으로 효율적이라 할 수 있다. 헬리콥터 동력원의 규모는 법률적인 총중량에 의하여 제한되므로 일반적인 농용 소형 무인 헬리콥터 엔진의 사양인 24.5 kW (32PS)를 적용한다면, 익형 V1505A은 받음각 $8{\sim}10^{\circ}$에서 그리고 익형 V2008B은 $7{\sim}9^{\circ}$정도에서 받음각이 제한되며 이때 총 양력은 1200~1300 N 정도로 예상된다.

  • PDF

Design and Fabrication of a Field Mill for Ground-Level Electric Field Measurement (대지전계 측정을 위한 필드밀의 설계 및 제작)

  • Kil, Gyung-Suk;Song, Jae-Yong;Kim, Il-Kwon;Kwon, Jang-Woo;Ahn, Chang-Hwan;Lee, Young-Keun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.52-59
    • /
    • 2007
  • A field mill capable of measuring the magnitude and polarity of electric fields at the ground level was studied to apply to a lightning warning system as a sensor. We designed and fabricated a planar-shutter type field mill with a rotating-vanes. A calibration of the field mill was performed in a vertically symmetrical arrangement which consists of two equal size parallel round plates to form a homogeneous electrical fields. The sensitivity of the field mill was adjusted at 0.5[V/kV/m], and this covers a ranges from 200[V/m] to 20[kV/m]. After the calibration experiment, the field mill was installed on the roof of a building to measure the changes of electric field intensity caused by thunderclouds. During the period from July 1. 2006 to July 15. 2006, the electric field intensity was recorded a ranges of $+2[kV/m]{\sim}-6[kV/m]$ depending on generation, extinction and movement of thunderclouds. From the actual test on the ground it is confirmed that the field mill has a good performance necessary for the measurement of DC electric fields.

Radiation Field in PWR Plants (PWR 발전소에서의 방사선장 특성)

  • Song, Myung-Jae;Kim, Hee-Keun;Kim, Bong-Hwan;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.17 no.2
    • /
    • pp.61-70
    • /
    • 1992
  • Photon, neutron and beta radiation fields were measured at PWR plants which are the representative types of nuclear power plant operated in Korea. The photon energy spectra were measured at locations in the auxiliary building during operation period and in the containment vessel(C/V) during shutdown period using a portable gamma spectrometer with a HPGe detector. The distribution of average energy was found to range from 440 to 780 keV in the C/V and from 280 keV to 760 keV in the auxiliary building, respectively. The average neutron energy measured at the five locations around the operation deck in the C/V in operation using a BMSS (Bonner Multi-Sphere Spectrometer) ranged from 20 keV to 210 keV. A computer code, BUNKI was used to unfold the spectrum. The beta energy spectra in the C/V and in the auxiliary building in annual outage were determined using 14 smear samples taken from the highly contaminated areas. The analysis showed that the representative corrosion product, $^{60}Co$ made main contribution to the beta energy field.

  • PDF

Synthetic Conditions and Rheological Characteristics of Barium Sulfate (황산바륨의 합성조건과 유동학적 특성)

  • Shin, Wha-Woo;Kim, Jun-Hea;Choi, Kwang-Sik;Chang, Young-Soo;Lee, Kwang-Pyo
    • YAKHAK HOEJI
    • /
    • v.36 no.6
    • /
    • pp.538-547
    • /
    • 1992
  • Optimal synthetic condition of barium sulfate were investigated from the viewpoint of yield and bulkiness according to a randomized complete block design proposed by G.E.P. Box and K.B. Wilson. Barium chloride and magnesium sulfate were utilized as reactants in order to prepare barium sulfate in this study. It was found that optimum temperature range of reactant solutions was $60{\sim}100^{\circ}C$ and the optimum concentration range of the reactant solutions was $10{\sim}17.3%$ and $10{\sim}20%$ respectively, on the viewpoint of yield and bulkiness. The optimum mole ratio of $BaCI_2$ to $BaSO_4$ was in the range of $1.50{\sim}2.0$ and the optimum mole ratio of $BaCI_2$ to $BaSO_4$ was in the range of $1.50{\sim}2.0$ and the optimum reacting time range was $15{\sim}20$ minutes. The optimum drying temperature range was $110{\sim}130^{\circ}C$ from the viewpoint of yield, but it was $90{\sim}110^{\circ}C$ on the basis of bulkiness. Apparent viscosity of barium sulfate suspensions dispersed in various concentrations of Na. CMC was measured by using Brookfield synchrolectric viscometer model LVT, the relative equation, log ${\eta}_{sp}=A+B.{\phi}$ was examined and the equation was found to agree fairly well. 1 w/v% Na. CMC aqueous solution and 0.1 volume fraction of $BaSO_4$ powder were optimum in the preparation of $BaSO_4$ suspension showing highest viscosity at infinite shearing.

  • PDF

Emission Characteristics of VOCs in Drying Process for Plywood Manufacturing (합판 제조용 목재 건조공정에서의 휘발성 유기화합물(VOCs) 배출특성)

  • Jang, Jeong-Gook;Kim, Mi-Ran
    • Journal of Environmental Science International
    • /
    • v.17 no.12
    • /
    • pp.1381-1390
    • /
    • 2008
  • Emission characteristics of volatile organic compounds (VOCs) were investigated in the flue gas emitted from wood drying process for plywood manufacturing. The moisture content of raw timber was average 48%, and its density was $831.55kg/m^3$. But the moisture content of dried wood is needed less than around 10%, thus the moisture contents of flue gas should be remarkably high(about 18.2 V/V%). Therefore, the vapor in flue gas is equivalent to 320 ton-vapor/day when 1100 ton-wood/day is treated in the wood drying process. The temperature of flue gas ranges from $140^{\circ}C\;to\;150^{\circ}C$ in each dryer stack with exception of the input site of wood(about $110^{\circ}C$). The velocity of flue gas in each stack ranges from 1.7 to 9.7m/sec. In order to assess the concentrations and attribution rate of odorous compounds, it was analyzed about 40 VOCs in the flue gases. It was found that the major odorous compounds were 8 compounds, and the concentrations of major VOCs(ppm) were as follows; benzene: $0.054{\sim}0.052$, toluene: $1.011{\sim}2.547$, ethylbenzene: $0.472{\sim}2.023$, m,p-xylene: $0.504{\sim}3.245$, styrene: $0.015{\sim}0.148$, o-xylene : $0.271{\sim}1.097$, ethanol: $11.2{\sim}32.5$, ${\alpha}$-pinene: $0.908{\sim}10.578$, ${\beta}$-pinene: $0.982{\sim}14.278$. The attribution rate of terpenes (${\alpha}$-pinene, ${\beta}$-pinene) was about 60.56%, and that of aromatics and alcohols was about 22.77%, and 16.67%, respectively. It is suggested that the adequate control device should be used to control both the water soluble and non-soluble compounds because both compounds were mixed in flue gas.

Remanufacturing of Commercial $V_2O_5-WO_3/TiO_2$ Catalyst used in the SCR Process of Incinerator (소각장 SCR 공정에서 사용되는 상용 $V_2O_5-WO_3/TiO_2$ 촉매의 재제조에 관한 연구)

  • Yoon, Goan-Gu;Yoo, Man-Sik;Lim, Jong-Sun;Kim, Tae-Won;Park, Hea-Kyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.9
    • /
    • pp.970-977
    • /
    • 2005
  • The commercial $V_2O_5-WO_3/TiO_2$ catalysts which had been exposed to the off gas from incinerator for a long time were remanufactured by washing with distilled water and arid solution and reimpregnation with catalytic active components($V_2O_5-WO_3$). The catalytic properties and NOx conversion reactivity of those catalysts were examined by analysis equipment and NOx conversion experiment. Under the experimental condition used in this study, the remanufactured catalysts activated by distilled water ultra sonic cleaning, the catalytic activity was recovered in the range of $66{\sim}93%$ of that of the fresh and the maximum activity was showed when the ultra sonic cleaning time was more than 3 minutes. The remanufactured catalysts by acid solution ultra sonic cleaning, the catalytic activity was recovered in the range of $81{\sim}97%$ of that of the fresh catalyst and the maximum catalytic activity was shooed when the pH of the acid solution was 5. The remanufactured catalysts by reimpregnation with $V_2O_5$ and $WO_3$, the catalytic activity was recovered in the range of $87{\sim}100%$ of that of the fresh catalyst. Maximum catalytic activity was showed when the $V_2O_5$ was reimpregnated more than 1.0 wt %. In this case, the catalytic activity was recovered 97% of that of the fresh catalyst especially at the $150^{\circ}C$ of the experimental temperature.

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

Effect of Alum on the Rheological Properties of Gelatinized Solutions of Nonwaxy and Waxy Rice Starches (멥쌀 및 찹쌀전분 호화용액의 리올로지 특성에 미치는 Alum 첨가의 영향)

  • Lee, Shin-Young;Lee, Sang-Gui;Kwon, Ik-Boo
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.776-782
    • /
    • 1995
  • The effects of alum$(Al{\cdot}K(SO_4)_2{\cdot}12H_{2}O)$ on the rheological properties of $3{\sim}9%(w/v)$ gelatinized solutions of nonwaxy and waxy rice starches were investigated to evaluate the possibility of utilizing a starch modifying agent. Gelatinized non-waxy and waxy rice starch solutions showed a pseudoplastic flow behavior with yield stress. Pseudoplasticity of two rice starch solutions increased by the addition of alum$(0.05{\sim}1.0%,\;w/w)$. Alum increased the yield stresses and consistency indexes of two rice starches and these values decreased with increasing starch concentration. Also, alum(0.5%, w/w) increased the flow activation energy of gelatinized waxy rice starch solution and activation energy decreased with increasing waxy rice starch concentration in the range of $3{\sim}7%(w/v)$, but for the nonwaxy rice starch, activation energy decreased at starch concentration of 7%(w/v). From the above results, it was found that alum had the possibility of utilizing a modifying agent for the rheological property of gelatinized starch solution.

  • PDF