Series-Gap Characteristics of Transmission Line Arrester with Switching and Lightning Impulse Flashover Test (개폐서지 및 뇌충격 섬락시험에 따른 송전 피뢰기의 직렬공극 특성)

  • Cho, Han-Goo;Yoo, Dae-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.484-485
    • /
    • 2007
  • This paper describes the series-gap characteristics of transmission line arrester with switching and lightning impulse flashover test. The transmission line arrester exhibited external gap because it is must not flashover with switching impulse on the other hand it is must flashover with lightning impulse. In accordance, minimum and maximum length of series-gap was determinated with these tests. As gap length is increased flashover voltage was increased in the range of 315.4 kV~496.3 kV and negative polarity exhibited a high voltage. As a result, It was thought tat the series-gap length of transmission line arrester exhibited in the range of 580 mm~1100 mm.

  • PDF

Oprimization Study for the CRC PIXE System Beam Transport Line

  • Jeong, Cheol-Ki;Lee, Goung-Jin
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.59-63
    • /
    • 2014
  • Proton Induced X-ray Emission (PIXE) is a MeV ion beam analysis method for use with particle accelerators. PIXE uses low-energy charged particles as an excitation mechanism to generate characteristic x-ray emission from each element in a target. In PIXE analysis, the beam current used is from a few nA to several tens of nA. Chosun University (Cyclotron Research Center) designed a $50{\mu}A$ beam line from the 13 MeV cyclotron for use with a PIXE analysis system, as well as performing beam transport line optimization research. In this study, the beam line operation conditions for the optimization process of beam transport and beam characteristics are shown.

Current Limiting Characteristics of a Resistive SFCL for a Single-line-to-ground Fault in the 22.9 kV System (1선 지락사고에 대한 배전급 저항형 초전도 한류기의 전류제한특성)

  • 최효상;황시돌;현옥배
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.6
    • /
    • pp.505-510
    • /
    • 2001
  • We simulated the current limiting characteristics of a resistive superconducting fault current limiter (SFCL) for a single line-to-ground fault in the 22.9 kV system. The transient current during the fault increased to 6.33 kA, 5.80 kA and 3.71 kA without SFCL at the fault angles 0$^{\circ}$, 45$^{\circ}$ and 90$^{\circ}$, respectively, a resistive SFCL limited effectively the fault current to 2.27 kA in a half cycle without any DC components. The maximum quench resistance of an SFCL, 16Ω was suggested to be appropriate to limit the fault current in the 22.9 kV distribution system, considering the operating cooperation of a protective relay and the current limiting performance of an SFCL.

  • PDF

Fault Analysis of a Gas Circuit Breaker in the 154kV Power Line (154kV 전력계통 가스차단기 고장 분석)

  • Kim, Young-Kyu;Ko, Young-Hoan;Jung, Lee-Sig;Lee, Sang-Il
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.342-344
    • /
    • 2008
  • This paper describes fault analysis of a $SF_6$ gas circuit breaker of a transformer in a hydro power plant which is connected to the 154kV line. The fault is a single-line-to-ground fault, so that it gives power generation halt and economical loss. The analysis has been done in aspects of the status of the breaker, insulation degradation, surge invasion and earthing resistance of the switchyard.

  • PDF

Development of Live-line Insulator Tester and Its Application to 154kV Power Lines - Part 2 : Inspection Algorithm Development (활선애자점검기의 개발 및 154kV 선로에의 적용 - 제2부 : 진단 알고리즘 개발)

  • Park, Joon-Young;Lee, Jae-Kyung;Cho, Byung-Hak;Oh, Ki-Yong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.89-95
    • /
    • 2010
  • A new live-line insulator tester was developed to detect faulty insulators in 154kV power transmission lines. This paper is the second part of the two-part paper and deals with its inspection algorithm development. Unlike normal condition with low pollution and low humidity, the inspection data measured in the field under high pollution or high humidity showed that the voltage distribution of an insulator string has offsets in comparison with those of others and its insulation resistances are greatly decreased, which leads to wrong results of the existing inspection algorithms under such conditions. To solve this problem, we propose new diagnosis algorithms that can exactly detect faulty insulators from measured data regardless of environmental conditions. Its effectiveness was validated by live-line field tests in actual power lines.

Electrical and Optical Characterization of the Vacuum In-Line Sealed PDP Panel

  • Kwon, Sang-Jik;Kim, Jee-Hoon;Kim, Tae-Ho;Shon, Byeong-Kyoo;Yang, Hwi-Chan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.832-835
    • /
    • 2003
  • By using vacuum in-line driving and photoluminescence measuring method, we have observed the electrical and optical characteristics of the vacuum in-line sealing technology and analyzed the effect of the base vacuum level before filling the plasma gas. In the case of base vacuum level of $1{\times}10^{-3}$torr, the firing voltage of a 2-inch diagonal PDP panel was ranged from 310 to 345V depending on the plasma gas pressure of 200 to 300torr and luminous efficiency was ranged from 0.0227 to 0.0367 lm/W depending on the input voltage level of 330 to 225V. While, in the case of $1{\times}10^{-6}$, the characteristics were significantly improved. As a results, the firing voltage was ranged from 295 to 318V and luminous efficiency was from 0.0278 to 0.0451 lm/W.

  • PDF

Effects of Base Vacuum Level on Discharge Characteristics in Vacuum In-Line Sealing Process for High Efficient PDP

  • Kwon, Sang-Jik;Jang, Chan-Kyu
    • Journal of Information Display
    • /
    • v.5 no.4
    • /
    • pp.7-11
    • /
    • 2004
  • Effects of base vacuum level on the electrical and optical characteristics of the plasma display panel (PDP) were investigated. The relationship between efficiency and base vacuum level before filling discharge gas was analyzed. For the base vacuum level of $1{\times}10^{-4}$ torr, firing voltage of a 2-inch diagonal PDP panel was 232 V at the discharge gas pressure of 400 torr and luminous efficiency was 1.5 lm/W at 180V sustaining pulse. On the other hand for $1{\times}10^{-6}$torr, the firing voltage was reduced to 215 V and luminous efficiency was improved considerably to 2.5 lm/W. We successfully demonstrated the smooth operation of tip-less PDP fabricated using vacuum in-line sealing method.

Profiles of electric and magnetic fields in the vicinity of 22.9[kV] Distribution Line (22.9[kV] 배전선로 주변의 전장과 자장의 분포)

  • Lee, Bok-H.;Gil, Hyoung-J.;Ahn, Chang-H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1653-1655
    • /
    • 1998
  • In this paper, measurement and analysis of ELF electric and magnetic fields in the vicinity of 22.9[kV] distribution line have been performed. The height of measuring point from the earth's surface was 1[m], and the distance between the device and the operator was more than 3[m]. The experiments have been carried out by lateral profile, and we have made use of FIELDS program for the sake of comparision the experimental data with the theoretical value. Electric and magnetic fields intensity were strong under a distribution line, and were inversely proportional to lateral distance. The profiles of electric field were M shape and those of magnetic field were $\cap$ shape. Electric and magnetic fields intensity were increased with increasing the measurement height.

  • PDF

Calculation of the Induced Voltage and Current for a Human and an Object Close to 765kV AC Double Circuit Transmission Line (765kV 교류 2회선 송전선 인근의 생체 및 물체 유도 전압, 전류 계산)

  • Min, Suk-Wen;Kim, Eung-Sik;Myeong, Sung-Mo;Lee, Byeong-Yoon;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1509-1511
    • /
    • 1994
  • This paper calculates the induced voltage and current for a human and a car under 765 kV AC double circuit transmission line. A human and a car is simulated as two dimension by the use of charge simulation method and as three dimension by using surface charge method. The phase arrangement of transmission line is varied to calculate the induced voltage and current. In two cases a human and a car is grounded or floated, the induced voltage and current is also compared.

  • PDF

A Study On The Improved Line Regulation For High Efficiency BoostDC-DCConverter (고효율 Boost DC-DC 변환기를 위한 Line Regulation 향상에 대한 연구)

  • Doo, Su-Yeon;Jeong, Seong-Yon;Chung, Jin-Il;Kwack, Kae-Dal
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.391-392
    • /
    • 2007
  • In recent, portable information and communication terminals such as a notebook computer, an electronic pocketbook, a hand personal computer(PC) have been regards as the leading role in the coming next generation portable multimedia terminals which have hi-directional wireless data communication capability and can receive information and communication services such as electronic mail, database searching, and electronic shopping at anytime and anyplace. Therefore, in this paper, the circuit is simulated by 0.35um memory process used Current Limit for Boost DC-DC converter. Supply voltage $2.5V{\sim}3.3V$, output voltage 5V, Clock Frequency 1MHz, output current 200mA and line regulation decreased 12.46%.

  • PDF