Development of a 170kV 50kA Capacitorless Gas Circuit Breaker

  • Park, K. Y.;K. D. Song;Y. H. Oh;W. P. Song;J. H. Kang;Park, S. W.
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권3호
    • /
    • pp.73-76
    • /
    • 2003
  • In modern EHV (Extra High Voltage) class GCBs (Gas Circuit Breakers), the interruption capability for SLF (Short Line Fault) is one of the most important aspects of performance required for GCBs. Up to now, the SLF interruption capability of EHV class GCBs was partially assisted by the adoption of capacitors able to decrease the dV/dt of the TRV (Transient Recovery Voltage), particularly the TRV on the line side. This paper describes the technique to increase the SLF interruption capability of EHV class GCBs as well as the procedure to develop capacitorless l70kV 50kA GCB.

154kV XLPE 케이블 실선로 부분방전 검출 (Partial Discharge Measurement for 154kV XLPE Cable Line)

  • 김충식;이전선;김종철;박창기;석광현;김원년
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.23-25
    • /
    • 2004
  • HFPD(High Frequency Partial Discharge) measurement has been widely performed to diagnose cable system in the world. Shin-Yeongdeungpo 345kV XLPE line was successfully diagnosed by PD measurement methode last year. Moreover, aged power cable lines which were installed 15 years ago have been tested from this year. In this paper, the result of PD diagnosis for aged 154kV cable line is reported. The PD pattern from TMJ which was monitored by PD measurement system for several days showed typical void pattern. The joint was replaced and voids between semi-conductor layer and insulating layer in the joint was founded.

  • PDF

In Line Plastic-Optical-Fiber Temperature Sensor

  • Seo, Hyejin;Shin, Jong-Dug;Park, Jaehee
    • Current Optics and Photonics
    • /
    • 제5권3호
    • /
    • pp.238-242
    • /
    • 2021
  • In this paper, we present an in line plastic-optical-fiber (POF) temperature sensor based on intensity modulation. The in line POF temperature sensor is composed of a POF, including an in-fiber micro hole filled with reversible thermochromic material, the transmittance of which depends on temperature. The reversible thermochromic material was cobalt chloride/polyvinyl butyral gel. A cobalt chloride solution of concentration 30.8 mM was formulated using 10% water/90% ethanol (v/v) solution, and gelled by dissolving polyvinyl butyral in this solution. Four types of in line POF sensors, with in line micro holes of four different diameters, were fabricated to measure temperature in the range of 25 to 75 ℃. The output optical power of all of these in line POF temperature sensors was inversely proportional to the temperature; the relation between output power and temperature was approximately linear, and the sensitivity was proportional to the diameter of the in-fiber micro hole. The experimental results indicate that an in line POF sensor can be used effectively for measuring moderate temperatures.

13 kV급 수력발전기 고정자 권선용 On-line 부분방전 측정 시스템 개발 및 현장적용 평가 (Development and Site Evaluation of the On-line Partial Discharge Measuring System on the 13 kV Class Stator Windings for Hydro Generator)

  • 선종호;황돈하;윤영호;신병철;오봉근;강동식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권4호
    • /
    • pp.189-198
    • /
    • 2006
  • In order to improve the reliability of stator windings for hydro generators, it is necessary to detect the defective point and life assessment of the high voltage windings. Especially the on-line partial discharge (PD) test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting generators, this method has been proven the major testing technology in high voltage rotating machines nowadays. The purpose of this paper is to describe the method of the on-line PD measurement on stator windings for hydro-generator with 13 [kV] class ceramic coupler (CC), on-line PD measuring system, terminal box, and index parameters. Also, the developed PD measuring system and 13 [kV] class CC were installed Daechung-dam generator #2. It was found that this installed sensor and system had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz.

대칭형상의 평판 전극 주위의 비대칭 절연유체 유동 (Asymmetric Electrohydrodynamic Flow of Dielectric Liquid around Symmetric Coplanar Electrodes)

  • 백광현;조동식;서용권
    • 한국가시화정보학회지
    • /
    • 제11권1호
    • /
    • pp.48-52
    • /
    • 2013
  • This paper presents experimental observation of asymmetric electrohydrodynamic flow generated around a pair of symmetric coplanar electrodes. Electrodes are attached on the bottom of the cavity containing a dielectric liquid, i.e., a mixture of dodecane and 0.5% wt Span80. In the first experiment, an AC voltage of 1500 V is applied with the frequency varying in the range 10~500 hz and the left electrode being grounded. The flow patterns show that the center line of vortices is unexpectedly tilted to the left side. If the right side electrode is grounded, the center line is tilted to the right side. The magnitude of the fluid velocity shows an irregular variation with the frequency in the range 10 Hz~100 Hz, beyond which it simply decays. In the second experiment, we applied fixed AC with 1000 V and 60 Hz superposed by DC voltage varying in the range -1000 V ~ +1000 V. The center line of the flow pattern is tilted to the right side with positive DC voltage and to the left side with negative DC. We have managed to show that the flow pattern can be symmetric with a suitable combination of DC and AC, e.g., DC 850 V plus AC 1000 V with the frequency 10 Hz.

축소 모의된 22.9 kV-Y 배전선로의 유도 전압에 대한 신뢰성 검증 (Verification of Reliability by the Induced Voltage of a Downscaled and Simulated 22.9kV-Y Distribution Line)

  • 김점식;최충석
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.26-31
    • /
    • 2015
  • The purpose of this paper is to measure the induced voltage of the downscaled and simulated overhead ground wire of a 22.9kV-Y distribution line. This study performed a test of the downscaled and simulated distribution line according to whether it is grounded or not and the value of the ground resistance. In order to verify the reliability of the data measured by the test, the data was analyzed using the Minitab 17 program. It was found that the induced voltage of the downscaled and simulated distribution line is influenced by the value of the ground resistance. It was also found that the ground resistance obtained at a certain point is closely related to whether electric poles are grounded or not. The analysis results of the measured test data with a statistical method showed that the Anderson Darling (AD) was analyzed to be the smallest as 0.188 when the ground resistance of the electric poles had been maintained at $10{\Omega}$. In addition, the P value analyzed to be 0.894 which is in the proximity of the theoretical value of 1 and verified the reliability of the test data. It could be seen that the data measured by the downscaled simulation test forms a linear graph. It is thought that if a distribution line is installed in the same manner as the downscaled, simulated distribution line, the mean induced voltage will be reduced and reliability will be increased.

Analysis of Off-Line and On-Line Partial Discharge in High Voltage Motor Stator Windings

  • Kim, Hee-Dong;Kong, Tae-Sik;Lee, Sang-Kil;Kim, Beom-Soo;Kim, Doo-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1086-1092
    • /
    • 2015
  • The off-line and on-line partial discharge (PD) in the stator winding of three high-voltage (HV) motors (1,400 HP, 6.6 kV) is measured and analyzed in this paper. The off-line PD is measured at high values between 24,300 ~ 36,100 pC after 18 years of motor operation. Spare replacement motors were not available for testing the degree of deterioration of the stator windings in standstill status. Therefore, on-line periodic analysis was conducted to monitor the trend of PD after installing a ceramic sensor (110 pF, 6.6 kV) in the terminal box for each phase of each motor. In the stator winding of the No.1 and No.2 HV motors, which showed high magnitudes of off-line PD and low magnitudes of on-line PD, defects are expected to appear in the neutral end of the winding. On the contrary, in the stator windings of the No.3 HV motor, which exhibits high off-line and on-line PD magnitude, defects are expected to appear in the terminal end of the winding where a voltage close to the phase voltage is applied.

Microstrip-to-Coplanar Strip Line 급전구조를 갖는 V-LTSA 의 설계 및 실험 (Design and Experiment of V-LTSA with Microstrip-to-Coplanar Strip Line Feed)

  • 김혜리;김남현박노준강영진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.395-398
    • /
    • 1998
  • In this paper, the design, fabrication, and experiments of linearly tapered slot antenna(LTSA) with uniplanar microstrip-to-coplanar strip(CPS) line transitions are presented. The effect of reducing and increasing with taper width G teper longth 1, and opening angle are also mesured at 10 GHz.

  • PDF

MEASUREMENT OF LINE PROFILE STEEPNESS AS A POSSIBLE TOOL FOR DEDUCING A TOTAL MAGNETIC FLUX NEAR A NEUTRAL LINE

  • GRIGORYEV V. M.;KOBANOV N. I.
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.233-234
    • /
    • 1996
  • For obtaining estimates of a total magnetic flux, we propose to use measurements of ${\partial}I/{\partial}{\lambda}$. obtained by a modulation method which is formally identical to Stokes V-parameter measurements. In this case the polarization is not analyzed. It is advisable to use in measurements two parts of the spectral line wing.

  • PDF

주사탐침현미경을 이용한 Si 표면 국부 산화피막 형성시 선 높이에 대한 탐침 전위, 편향 셋포인트, 탐침 속도의 영향 (Local Anodization on Si surface Using Scanning Probe Microscope; Effects of Tip Voltage, Deflection Setpoint, and Tip Velocity on Line Height)

  • 김창환;최정우;신운섭
    • 전기화학회지
    • /
    • 제9권2호
    • /
    • pp.84-88
    • /
    • 2006
  • 본 연구에서는 주사탐침현미경을 이용한 Si 표면의 국부 산화피막 형성에 있어서, 탐침이 움직이면서 생기는 $SiO_2$의 일차원적인 선의 높이가 탐침 전위, deflection setpoint, 탐침 속도에 의해 어떻게 영향을 받는지 고찰해 보았다. -3 V 보다 작은 탐침 전위에서는 국부 산화피막 형성이 관찰되지 않았으며 -3 V 보다 큰 탐침 전위에서는, 탐침 속도가 $1{\mu}m/s$일 때, 1 V씩 증가함에 따라 0.47nm의 비율로 선의 높이가 높아졌다. Deflection setpoint는 탐침이 가하는 기계적인 힘의 표지가 되는데, $12\sim18nN$ 정도의 힘이 가해지지 않으면 국부 산화피막 형성이 관찰되지 않았다. 그 이상의 힘이 가해져야 국부 산화피막 형성이 관찰되는데 이때 선의 높이는 기계적인 힘과 무관하였다. 탐침 속도가 빨라짐에 따라 선의 높이는 낮아졌으나, 탐침 전위가 -5V인 경우, 0.7nm 이하로 낮아지지는 않았다.