• Title/Summary/Keyword: V-I.P-I curve

Search Result 84, Processing Time 0.027 seconds

A Study on Carrier Injection and Trapping by the High Field for MOS(Metal-$Al_2O_3$-p Si$) Structure (Metal-$Al_2O_3$-p Si$의 MOS 구조에 있어서 고전계에의한 Carrier주입과 트랩에 관한 연구)

  • Park, Sung Hee;Sung, Man Young
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.1
    • /
    • pp.102-109
    • /
    • 1987
  • This study is carrier out to investigate the carrier injection and the characteristics of trapping for the CVD deposited Al2O3 film on Si substrates. Samples used are metal -Al2O3-Si Structure in which metal field plates are used with Aluminium or God. Canier injection and trapping, which result in flat band voltalge shift, occur at fields as low as 1~2 MV/cm. An approximate method is proposed for computing the location of the centroid of the trapped electrons in this paper. Results show that carriers are trapped near the injecting interface at fields less than about 5MV/cm. Because of continued charging, a steady state can not be reached. Therefore the unique I-V curve is obtained when the traps are initially empty. By utilization of applied voltage on each point of the fresh device sample, it is measured the I-V surves for two polarities of applied voltage. The current densities observed in the Al2O3 films are much larger than those obtained in SiO2.

  • PDF

CCD PHOTOMETRY OF W UMa TYPE BINARY TY UMa (접촉형 쌍성의 진화 검증을 위한 TY UMa의 CCD 측광관측)

  • 강영운;황창덕;이희원;김천휘
    • Journal of Astronomy and Space Sciences
    • /
    • v.18 no.1
    • /
    • pp.55-62
    • /
    • 2001
  • We present VRI CCD photometry of W UMa type binary TY UMa. The light curves show that the secondary minimum is deeper than the primary minimum and the maximum I ($0.^{p}25$)is $0.^{m}023$ brighter than the maximum II ($0.^{p}75$). The V light curve has been analyzed and the photometric solutions have been determined by the method of Wilson & Devinney differential correction. We adopted the spot model to explain the asymetric light curve.

  • PDF

On-Line Calculation of the Critical Point of Voltage Collapse Based on Multiple Load Flow Solutions (다중조류계산을 이용한 전압붕괴 임계점의 On-Line 계산)

  • Nam, Hae-Kon;Kim, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.134-136
    • /
    • 1993
  • This paper presents a novel and efficient method to calculate the critical point of voltage collapse. Conjugate gradient and modified Newton-Raphson methods are employed to calculate two pairs of multiple load flow solutions for two operating conditions, i.e., both +mode and -mode voltages for two loading conditions respectively. Then these four voltage magnitude-load data sets of the bus which is most susceptible to voltage collapse, are fitted to third order polynomial using Lagrangian interpolation in order to represent approximate nose curve (P-V curve). This nose curve locates first estimate of the critical point of voltage collapse. The procedure described above is repeated near the critical point and the new estimate will be very close to the critical point. The proposed method is tested for the eleven bus Klos-Kerner system, with good accuracy and fast computation time.

  • PDF

PHOTOMETRIC STUDY OF NPA ROTATOR (5247) KRYLOV

  • Lee, Hee-Jae;Moon, Hong-Kyu;Kim, Myung-Jin;Kim, Chun-Hwey;Durech, Josef;Choi, Young-Jun;Oh, Young-Seok;Park, Jintae;Roh, Dong-Goo;Yim, Hong-Suh;Cha, Sang-Mok;Lee, Yongseok
    • Journal of The Korean Astronomical Society
    • /
    • v.50 no.3
    • /
    • pp.41-49
    • /
    • 2017
  • We conduct BVRI and R band photometric observations of asteroid (5247) Krylov from January 2016 to April 2016 for 51 nights using the Korea Microlensing Telescope Network (KMTNet). The color indices of (5247) Krylov at the light curve maxima are determined as $B-V=0.841{\pm}0.035$, $V-R=0.418{\pm}0.031$, and $V-I=0.871{\pm}0.031$ where the phase angle is $14.1^{\circ}$. They are acquired after the standardization of BVRI instrumental measurements using the ensemble normalization technique. Based on the color indices, (5247) Krylov is classified as a S-type asteroid. Double periods, that is, a primary period $P_1=82.188{\pm}0.013h$ and a secondary period $P_2=67.13{\pm}0.20h$ are identified from period searches of its R band light curve. The light curve phases with $P_1$ and this indicate that it is a typical Non-Principal Axis (NPA) asteroid. We discuss the possible causes of its NPA rotation.

A study on the design wax up technique for mandibular molar occlusion surface (하악구치 교합면의 design 조각법에 관한 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.107-126
    • /
    • 2002
  • The first function of occlusion is mastication. Therefore the functional restoration of occlusal surface is very important. The restoration of occlusal surface is three method as wax bite technique, F.G.P. technique, cone technique. Many dental technician is using compound method. I am using compound method of wax bite technique and cone technique. I have knew common point on each teeth during I have waxing up wax pattern. So I studied on the design waxup technique for mandible molar occlusion. The results of the study were as follows; 1. The dam wax up method can restore axial contour of teeth very easy and make short working time of wax pattern. 2. The height of dam must be same with cusp of adjacent teeth. 3. Automatically the contour of tooth is appeared if the contour of dam is relationship with cuspid line of adjacent teeth. 4. The height of contour of buccal, lingual surface is formed natural curve to add fluid wax by gravitation. 5. The development groove of mandible first premolar is appeared V form. 6. The development groove of mandible second premolar is appeared Y form. 7, The development groove of mandible first molar is appeared M form. 8. The development groove of mandible second molar is W form. 9. The embrasure is formed to carve around contact point area as round convex. It affects to axial form of tooth. 10. The buccal, lingual groove of molar is formed parallel with direction of teeth arrangement.

  • PDF

A Study on the design waxup technique for maxillary molar occlusion (상악구치 교합면의 design 조각법에 관한 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.21 no.1
    • /
    • pp.97-114
    • /
    • 1999
  • The first function of occlusion is mastication. Therefore the functional restoration of occlusal surface is very important. The restoration of occlusal surface is three method as wax bite technique, F.G.P. technique, cone technique. Many dental technician is using compound method. I have knew common point on each teeth during I have waxing up wax pattern. So I studied on the design waxup technique for maxillary molar occlusion. The results of the study were as follows ; 1. The dam wax up method can restore axial contour of teeth very easy and make short working time of wax pattern. 2. The height of dam must be same with cusp of adjacent teeth. 3. Automatically the contour of tooth is appeared if the contour of dam is relationship with cuspid line of adjacent teeth. 4. The height of contour of buccal, lingual surface is formed natural curve to add fluid wax by gravitation. 5. The development groove of Maxillary premolar is appeared V form. 6. The development groove of Maxillary molar is appeared W form. 7. The embrasure is formed to carve around contact point area as round convex. It affects to axial form of tooth. 8. I was knew that the lingual groove and stuart's groove of molar runs parallel with oblique ridge. 9. The buccal groove of molar is formed parallel with direction of teeth arrangement.

  • PDF

Effects of Baicalein on the Bioavailability of Nicardipine in Rats

  • Son, Hong-Mook;Choi, Jun-Shik
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.5
    • /
    • pp.291-296
    • /
    • 2010
  • This study was to investigate the effect of baicalein, an antioxidant, on the bioavailability of nicardipine after orally or intravenously administered nicardipine in rats. Nicardipine was administered orally (12 mg/kg) or intravenously (4 mg/kg) with or without orally administered baicalein (0.4, 2 or 10 mg/kg) to rats. In the inhibitory effect of baicalein on CYP3A4 activity, baicalein inhibited CYP3A4 activity with $IC_{50}$ values of 9.2 ${\mu}M$. The cell-based P-gp activity test using rhodamine-123 also showed that baicalein (30-10 ${\mu}M$, p<0.01) significantly inhibited P-gp activity. Compared with the control group (given nicardipine alone), the area under the plasma concentration-time curve (AUC) was significantly (2 mg/kg, P<0.05; 10 mg/kg, P<0.01) increased by 25.9-60.0%, and the peak concentration ($C_{max}$) was significantly (10 mg/kg, P<0.01) increased by 40.0% in the presence of baicalein after orally administration of nicardipine. Consequently, the relative bioavailability (R.B.) of nicardipine was increased by 1.26- to 1.60-fold and the absolute bioavailability (A.B.) was significantly (2 mg/kg, P<0.05; 10 mg/kg, P<0.01) increased by 26.0-59.9%. Compared to the i.v. control, baicalein did not significantly change pharmacokinetic parameters of nicardipine in i.v. administration. Accordingly, the enhanced oral bioavailability of nicardipine might be mainly due to increased intestinal absorption caused by P-gp inhibition rather than to reduced elimination of nicardipine by baicalein. The increase in the oral bioavailability might be mainly attributed to enhanced absorption in the small intestine via the inhibition of P-gp and reduced first-pass metabolism of nicardipine via the inhibition of the CYP3A subfamily in the small intestine and/or in the liver by baicalein. Based on these results, nicardipine dosage should be adjusted when given concomitantly with baicalein.

Fabrication of Thermoelectric Module and Analysis of its Power Generation Characteristics (열전발전소자 제작 및 발전특성 분석)

  • Choi, Taeho;Kim, Tae Young
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.2
    • /
    • pp.90-97
    • /
    • 2021
  • In this study, a Bi2Te3 thermoelectric generator (TEG) was fabricated to convert unused thermal energy into useful electrical energy. For the performance test, a dedicated experiment device consisting of a heating block operating with cartridge heaters and a cooling block through which a refrigerant flows was constructed. A 3×3 array of thermocouples was mounted on the heating block and the cooling block, respectively, to derive the temperature fields and heat transfer rate onto both sides of the TEG. Experiments were conducted for a total of 9 temperature differences, obtaining V-I and P-R curves. The results of 7 variables including Seebeck coefficients that have a major effect on performance were presented as a function of the temperature difference. The feasibility of the energy recovery performance of the developed TEG was verified from the maximum power output of 7.5W and conversion efficiency of 11.3%.

Electrochemical Determination of Ag(I) Ion at Chemically Modified Carbon-Paste Electrode Containing 1,5,9,13-Tetrathiacyclohexadecane (1,5,9,13-Tetrathiacyclohexadecane 수식전극을 사용한 Ag(I)의 전기화학적 정량)

  • Ha, Kwang Soo;Jang, Mi-Kyeong;Seo, Moo Lyong
    • Analytical Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.187-195
    • /
    • 1997
  • Chemically modified electrodes(CMEs) for Ag(I) were constructed by incoporating 1,5,9,13-tetrathiacyclohexadecane([16]-ane-$S_4$) with a conventional carbon-paste mixture composed of graphite powder and nujol oil. Ag(I) ion was chemically deposited onto the surface of the modified electrode with [16]-ane-$S_4$ by immersion of the electrode in the acetate buffer solution(pH=4.5) containing $5.0{\times}10^{-4}M$ Ag(I) ion. And then the electrode deposited with Ag(I) was reduced at -0.3V vs. S.C.E. Well-defined stripping voltammetric peaks could be obtained by scanning the potential to the positive direction. The CME surface was regenerated with exposure to 0.1M $HNO_3$ solution and was reused for the determination of Ag(I) ion. When deposition/measurement/regeneration cycles were 10 times, the response could be reproduced with relative standard deviation of 6.08%. In case of differential pulse stripping voltammetry, the calibration curve for Ag(I) was linear over the range of $5.0{\times}10^{-7}{\sim}1.5{\times}10^{-6}M$. And the detection limit was $2.0{\times}10^{-7}M$. Various ions such as Cd(II), Ni(II), Pb(II), Zn(II), Mn(II), Mg(II), EDTA, and oxalate(II) did not influence the determination of Ag(I) ion, except Cu(II) ion.

  • PDF

A Study on Performance of PEMFC with Variations on Stack Temperature and Mass Flow Rate (스택온도 및 유량변화에 따른 PEMFC의 출력특성 연구)

  • Park, Se-Joon;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.140-140
    • /
    • 2009
  • The polymer electrolyte membrane fuel cell(PEMFC) with the advantages of low-operating temperature, high current density, low cost and volume, fast start-up ability, and suitability for discontinuous operation becomes the most reasonable and attractive power system for transportation vehicle and micro-grid power plant in a household. 200W PEM-type FCs system was integrated by this study, then the electrical characteristics and diagnosis of the fuel cell were analyzed with variations on mass flow rate and stack temperature. The ranges of the variations are $20{\sim}70^{\circ}C$ on stack temperature and 1~8L/min on $H_2$ volume.

  • PDF