• Title/Summary/Keyword: V-곡선

Search Result 773, Processing Time 0.033 seconds

Site Characterization using Shear-Wave Velocities Inverted from Rayleigh-Wave Dispersion in Wonju, Korea (레일리파 분산을 역산하여 구한 횡파속도를 이용한 원주시의 부지특성)

  • Kim, Chungho;Ali, Abid;Kim, Ki Young
    • Geophysics and Geophysical Exploration
    • /
    • v.17 no.1
    • /
    • pp.11-20
    • /
    • 2014
  • To reveal shear-wave velocities ($v_s$) and site characterization of Wonju, Korea, Rayleigh waves were recorded at 78 sites of lower altitude using 12 to 24 4.5-Hz vertical geophones for 20 days during the period of February to September 2013. Dispersion curves of the Rayleigh waves obtained by the extended spatial autocorrelation method were inverted using the damped least-squares method to derive $v_s$ models. From these 1-D models, the average $v_s$ to a depth of 30 m ($v_s30$), $v_s$ of weathered rocks, depths to these basement rocks, and average $v_s$ of the overburden layer were derived to be $16.3{\pm}0.7m$, $576{\pm}8m/s$, $290{\pm}7m/s$, and $418{\pm}13m/s$, respectively, in the 95% confidence range. To determine adequate proxies for $v_s30$, we computed correlation coefficients of $v_s30$ with topographic slope (r = 0.46) and elevation (r = 0.43). An empirical linear relationship is presented as a combination of individually estimated $v_s30$ with weighting factors of 0.45, 0.45, and 0.1 for topographic slope, elevation, and mapped lithology, respectively. Due to a weak correlation between $v_s30$ obtained from inversion of dispersion curves and the proxy-based estimation (r = 0.50), however, the relatively large error range should be considered for applications of this relationship.

Antimicrobial Activities of Scutellariae Radix Extract against Vibrio parahaemolyticus (Vibrio parahaemolyticus에 대한 황금추출물의 항균활성)

  • 조성환;김영록
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.3
    • /
    • pp.534-538
    • /
    • 2002
  • To investigate the antimicrobial effects of Scutellariae Radix extract against Vibrio parahaemolyticus from food samples, Vibrio parahaemolyticus strains isolated from Tapes philippinarum were examined for their sensitivity to Scutellariae Radix extract. Total 66 Vibrio parahaemolyticus strains were isolated from Tapes philippinarm 72 samples (91.7%). The serotypes of isolated Vibrio parahemolytics were K-I group 7 strains (10.6%), K-IV group 5 strains (7.6%), K-II group 2 strains (3.0%), K-V group 2 strains (3.0%), K-VII group 2 strains (3.0%), K-VI group 1 strains (1.5%), K-VIII group 1 strains (1.5%) and antisera UT K-group 46 strains (69.7%) on antisera agglutination test, but K-III group and K-IX group strains were not found. The growth curves of isolates showed lag phase, logarithmic phase, stationary phase and death phase as typical sigmoid curve on the shellfish samples. After 6 hours, the group containing Scutellariae Radix extract differs from the control on shellfish samples in the growth inhibition curves, and Vibrio parahaemolyticus were inhibited in more than 1000 ppm Scutellariae Radix extract. The morphological changes were observed by transmission electron microscope and the microbial cells membrane was destroyed by Scutellariae Radix extract.

Electrical characteristics of MOS capacitors with Ge nanocrystals embedded in high-k materials (고유전체 박막에 형성된 Ge 나노크리스탈을 이용한 MOS 커패시터의 전기적 특성)

  • Yun, Jeong-Gwon;Lee, Hye-Ryoung;Park, Byoung-Jun;Cho, Kyoung-Ah;Kim, Sang-Sig
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1351-1352
    • /
    • 2007
  • $ZrO_2$$HfO_2$ 박막에 이온 주입을 거친 후 열처리 과정을 통해 Ge 나노입자를 형성시켜 MOS 커패시터를 제작하였다. C-V 곡선에서는 반시계 방향의 hysteresis가 관찰되었으며, $ZrO_2$ MOS 커패시터에서는 -9 V에서 9 V까지 전압변화를 주었을 때 3 V 정도의 메모리 윈도우가 나타남을 확인 할 수 있었다. 또한, $HfO_2$ MOS 커패시터에서는 -10 V에서 10 V까지 전압변화를 주었을 때 3.45 V의 메모리 윈도우를 관찰 할 수 있었다.

  • PDF

Seismic Fragility Analysis of Substation Systems by Using the Fault Tree Method (고장수목을 이용한 변전소의 지진취약도 분석)

  • Kim, Min-Kyu;Choun, Young-Sun;Choi, In-Kil;Oh, Keum-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.47-58
    • /
    • 2009
  • In this study, a seismic fragility analysis was performed for substation systems in Korea. To evaluate the seismic fragility function of the substation systems, a fragility analysis of the individual equipment and facilities of the substation systems was first performed, and then all systems were considered in the fragility analysis of the substation systems using a fault-tree method. For this research, the status of the substation systems in Korea was investigated for the classification of the substation systems. Following the classification of the substation systems, target equipment was selected based on previous damage records in earthquake hazards. The substation systems were classified as 765kV, 345kV, and 154kV systems. Transformer and bushing were chosen as target equipment. The failure modes and criteria for transformer and bushing were decided, and fragility analysis performed. Finally, the fragility functions of substation system were evaluated using the fault tree method according to damage status.

Metallic Damper Shape and Cyclic Behavior for the Seismic Capacity Improvement of Building Structures (건축구조물의 내진성능 향상을 위한 강재댐퍼 형상 및 이력 거동)

  • Lee, Hyun-Ho;Kim, Seh-Il
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.3
    • /
    • pp.123-130
    • /
    • 2010
  • The aim of this paper is a seismic performance evaluation of metallic damper devices which are efficient in workability and installation process. For this V shape and S shape dampers is considered. The strut figures of dampers are V shape and S shape and, the research parameters are strut height and angle of the dampers. ABAQUS program is used for nonlinear finite element analysis. The analysis is performed with the hysteretic curve that has maximum displacement with 50mm and has increased progressive. As a results of evaluating the yield strength, maximum strength and energy dissipation capacity of each device, V and S shape have a good strength capacity and the devices with strut angle $60^{\circ}$ and strut height 140 and 200mm are evaluated stable in seismic behaviors. The response of S shape is more efficient than that of V shape. In the yield strength estimation process, proposed formula can not estimate the yield strength of V and S shape dampers. Even though, the formula can not consider the variation of strut heights and strut angles. Finally the S shape damper is recommended in seismic performance than V shape damper.

Electrical and Retention Properties of MFSFET Device (MFSFET 소자의 전기적 및 리텐션 특성)

  • Chung, Yeun-Gun;Kang, Seong-Jun;Joung, Yang-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.3
    • /
    • pp.570-576
    • /
    • 2007
  • In this study, the characteristics of metal-ferroelectric-semiconductor FET (MFSFET) device is investigated using field-dependent polarization and square-law FET models. From drain current with the gate voltage variation, when coercive voltages of ferroelectric thin film are 0.5 and 1V, the memory windows are 1 and 2V, respectively. When the gate voltages are 0, 0.1, 0.2 and 0.3V, the difference of saturation drain currents of the MFSFET device at two threshold voltages in ID-VD curve are 1.5, 2.7, 4.0, and 5.7mA, respectively. As a result of the analysis for drain currents after tine lapse, which is based on the simulation for hysteresis loop and the fitting of retention properties of ferroelectric thin films such as PLZT(10/30/70), PLT(10) and PZT(30/70) thin film shows excellent reliability that the decrease of saturation current is about 18% after 10 years.

THE SLOPE OF ΔM LIGHT CURVE DEPENDING UPON THE ITS LOCATION IN CCD FRAME (CCD 이미지 상의 그 위치와 ΔM 광도곡선의 기울기)

  • 정장해;임인성
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.1
    • /
    • pp.39-46
    • /
    • 2002
  • BV observations for V523 Cas were performed with 1.8m telescope and 2K CCD camera at Bohyunsan Optical Astronomy Observatory, Korea, on October 27, 1999. ${\Delta}m$ light curves for 11 comparison objects were made. It was found that their light curve slopes are different each other. Factor analysis for items of slope, (b-v) , magnitude, X pixel, and Y pixel results that there is strong correlation between the slope and the location (X,Y). It might be due to problems of CCD cooling system.

Analysis on Driving Performance of Linear Induction Motor for Maglev System by Finite Element Method (유한요소법을 이용한 자기부상용 선형유도기의 운전 특성 분석법)

  • Kim, Ki-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4469-4474
    • /
    • 2014
  • This paper proposes a novel analysis method on the driving performance of LIM (linear induction motor) by FEM (finite element method). First, a linear model was converted with a rotation model to perform the dynamic analysis for a long time. Through the FEM model, the slip parameter for the control algorithm could be induced effectively. The LIM for the traction system was performed at a constant V/f in the region of constant torque, and a constant V and variable f in the region of constant power. Several slip characteristic curves according to the voltage and frequency were calculated by FEM in advance. The driving performance was then induced by interpolating the slip characteristic curves according to the load of the vehicle.

Breakdown Characteristics of Soils Caused by Impulse Currents (임펄스전류에 의한 토양의 절연파괴특성)

  • Lee, Bok-Hee;Lee, Kang-Soo;Kim, Hoe-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.103-109
    • /
    • 2010
  • In this paper, breakdown characteristics of soil in a coaxial cylindrical electrode system stressed by impulse currents were experimentally investigated. The breakdown voltage and current waveforms for 4 types of soils were measured, and the threshold electric field intensity, the time-lag to breakdown and the voltage-current (V-I) curves were analyzed and discussed. As a result, the breakdown voltage and current waveforms are strongly dependent on the grain size of soil, and the voltage and current waveforms for gravel and sand differ from those for silt and loess. The threshold electric field intensity Ec is increased in the order of gravel, sand, loess and silt. The V-I curves for all test samples show a 'cross-closed loop' of ${\infty}$-shape. Also, the time-lag to breakdown for gravel and sand are longer than those for silt and loess. It is expected that the results presented in this paper will provide useful information on the design of improving transient performance of a grounding electrode system subjected to lightning current considering the soil ionization.

Review and Improvement of Highway Design Consistency Evaluation Models (설계 일관성 평가 모형의 고찰과 개선방안 연구)

  • Kim, Sang-Youp;Choi, Jai-Sung;Yang, Ji-Eun;Kim, Moon-Kyum
    • International Journal of Highway Engineering
    • /
    • v.8 no.4 s.30
    • /
    • pp.63-74
    • /
    • 2006
  • It's essential to meet the expectations of drivers through reasonable road design, which makes the drivers to recognize the conditions of road sufficiently. In this case, we could say that because the roads are consistently designed, drivers can make a safe and comfortable drive. There are so many studies about the alignment design consistency methods which are previously mentioned. In this study, Firstly we categorize the studies which are concerned with the estimation of the alignment design consistency methods and then apply the method which fits for the actual condition into the practice. And we'll make a realistic method by using the data which aye collected from the National Road. The developed model in this study is the predicting model including speed($V_t$) as the variable on the upper stream 100m of the curve. This model was developed which divided to two cases in the all directions of two lanes; One case is the $R{\leq}200m$ and another case is the R>200m. In the section of the $R{\leq}200m$, this case was influenced on the road alignment(R) and($V_t$) and another section was found that is affected to the speed($V_t$) on the upper stream loom rather than the effect of road alignment(R). In the case of all directions of four lanes, however, this study is predicted divided to two sections on the 400m of R, these section have more influenced to($V_t$) than the road alignment factors. This result of the four lanes was represented to different result with the two lanes. This study will further need development of the predicting model with the higher confidence through collecting data with more the exact data, the various road alignment data and speed of the several sections on the upper stream on the curve.

  • PDF