• Title/Summary/Keyword: V shape

Search Result 1,236, Processing Time 0.025 seconds

Dosimetric Comparison of Left-sided Whole Breast Irradiation using a Virtual Bolus with VMAT and static IMRT (좌측 유방의 세기변조 방사선치료 시 Virtual Bolus 적용에 따른 선량 변화 비교 평가)

  • Lim, Kyeong Jin;Kim, Tae Woan;Jang, Yo Jong;Yang, Jin Ho;Lee, Seong Hyeon;Yeom, Du Seok;Kim, Seon Yeong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.51-63
    • /
    • 2019
  • Purpose: Radiation therapy for breast cancer should consider the change in breast shape due to breathing and swelling. In this study, we evaluate the benefit of using virtual bolus for IMRT of left breast cancer. Materials and methods: 10 patients with early breast cancer who received radiation therapy after breastconserving surgery compared the VMAT and IMRT plans using the virtual bolus method and without using it. The first analysis compared the V95%, HI, CI of treatment volume, Dmean, V5, V20, V30 of ipsilateral lung, and Dmean of heart in VMAT plan made using the virtual bolus method(VMAT_VB) to the plan without using it(VMAT_NoVB) in case there is no change in the breast. In IMRT, the same method was used. The second analysis compared TCP and NTCP based on each treatment plan in case there is 1cm expansion of treatment volume. Result: If there is no change in breast, V95% in VB Plan(VMAT_VB, IMRT_VB) and NoVB Plan(VMAT_NoVB, IMRT_NoVB) is all over 99% on each treatment plan. V95% in VMAT_NoVB and VMAT_VB is 99.80±0.17% and 99.75±0.12%, V95% in IMRT_NoVB and IMRT_VB is 99.67±0.26% and 99.51±0.15%. Difference of HI, CI is within 3%. OAR dose in VB plan is a little high than NoVB plan, and did not exceed guidelines. If there is 1cm change in breast, VMAT_NoVB and IMRT_NoVB are less effective for treatment. But VMAT_VB and IMRT_VB continue similar treatment effect compared in case no variation of breast. Conclusion: This study confirms the benefit of using a virtual bolus during VMAT and IMRT to compensate potential breast shape modification.

The effect of micro pore on the characteristics of crack tip plastic zone in concrete

  • Haeri, Hadi;Sarfarazi, V.
    • Computers and Concrete
    • /
    • v.17 no.1
    • /
    • pp.107-127
    • /
    • 2016
  • Concrete is a heterogeneous material containing many weaknesses such as micro-cracks, pores and grain boundaries. The crack growth mechanism and failure behavior of concrete structures depend on the plastic deformation created by these weaknesses. In this article the non-linear finite element method is used to analyze the effect of presence of micro pore near a crack tip on both of the characteristics of crack tip plastic zone (its shape and size) and crack growth properties (such as crack growth length and crack initiation angle) under pure shear loading. The FE Code Franc2D/L is used to carry out these objectives. The effects of the crack-pore configurations and the spacing between micro pore and pre-excising crack tip on the characteristics of crack tip plastic zone and crack growth properties is highlighted. Based on the obtained results, the relative distance between the crack tip and the micro pore affects in very significant way the shape and the size of the crack tip plastic zone. Furthermore, crack growth length and crack initiation angle are mostly influenced by size and shape of plastic zone ahead of crack tip. Also the effects of pore decrease on the crack tip by variation of pore situation from linear to perpendicular configuration. The critical position for a micro pore is in front of the crack tip.

The Discharge Distribution Analysis of Cross-Linking Polyethylene due to Shape of Electrode (전극 형태에 따른 가교폴리에틸렌 절연체의 방전분포해석)

  • Kim, Tag-Yong;Yang, Jae-Hoon;Kim, Gwi-Yeol;Lee, Chung-Ho;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.308-311
    • /
    • 2004
  • In this paper, we investigated $\phi-q-n$ distribution to inquire discharge characteristic according to variation of electrode. Also, we investigated Weible distribution of discharge number using Weible analysis to search the relationship between a part discharge and shape of electrode. We increased voltage 1[kV] AC 60[Hz] of impressed voltage, data is acquired a generating discharge for 10 seconds after impressing voltage. Also, as we repeated the experiment 10 times at same condition, analyzed foible using data except for maximum and minimum. As the result, we confirmed that discharge generating and discharge quantity were significantly increased narrowing radius of electrode, also discharge frequency was close to shape of a standard distribution.

  • PDF

A Study on Hudan Bangryung-Banbee (후단 방령반비에 관한 고찰)

  • 홍나영
    • Journal of the Korean Society of Costume
    • /
    • v.44
    • /
    • pp.117-129
    • /
    • 1999
  • Hudan Bangryung-Banbee was the name for a traditional dress which had a square neckline collar. Among Bangryung-Banbee, there was a particular style which, plus with the square neckline collar, had the half-length sleeve, bodice whose back length was shorter than the front. This kind of style shown a big difference from the typical pattern of traditional Korean costumes which had the V neck and had to fold the neckband of the clothes in Y-shape. This study focused on the analysis of the change of Hudan(後短) Bangryung-Banbee style. Bangryung-Banbee of the half sleeve/shortened back style had been usually excavated around the period of the Japanese invasion of Chosun dynasty(1592-1598). And up to now this kind of the costumes was never found before the fifteenth century or after the eighteenth century in Korea. Therefore it is thought that Bangryung-Banbee was worn widely in the middle of the Chosun dynasty. However, the shape of the collar and the length of sleeve and of dress were variously used, so it must be recognized that there existed much more diverse styles of Bangryung-Banbee than it was known today. But as the times passed away, the lined Bangryung-Banbee disappeared, and the collar of Bangryung-Banbee changed from square neckline to rounded Wonsam(圓衫) or Baeja(背子)-shape. And in the case of Bangryung-Banbee's front length, the original style disappeared, while a new style of longer back appeared.

  • PDF

Stability Analysis of the Ignition Coil using Partial Discharge (부분방전법을 이용한 점화코일의 안정도 해석)

  • Park, Hee-Doo;Kim, Tag-Yong;Shin, Hyun-Taek;Kim, Weon-Jong;Shin, Jong-Yeol;Hong, Jin-Woong
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.53-58
    • /
    • 2006
  • This paper has been addressed on the discharge characteristics of the ignition coil by Weibull function. It analyzed discharge number and amount of discharge using Weibull distribution to know the inter-relationship between partial discharge and mileage. We detected the discharge which happens for 10 seconds. The applied voltage increased by 0.5[kV] at discharge inception voltage. We diagnosed failure rate using the shape parameters. As a result, we confirmed that the failure rate was increased, because the shape parameter showed the value of 5 according to increasing mileage degradation. Also, it is considered to increase the degradation of inner insulator of ignition coil. Because failure rate of virgin was increased from 0[%] to 25[%] after degradation, stability analysis of the ignition coil using Weibull analysis is possible.

Ultrasound Imaging Improvement using Higher Harmonics of Impluse Sound (고조파음원에 의한 초음파영상의 해상도 개선)

  • Chang, Jee-Won;Yang, Jeong-Won;Kim, Dong-Hyun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.29 no.4
    • /
    • pp.292-300
    • /
    • 1993
  • Acoustical imaging has made brilliant progress in the medical science field, and has also made much progress in the nondestructive testing and under water acoustics applications since doctor Dussik brother has studied about possibilities of making images of brain by recording variations in the intensity of ultrasonic beam from head in 1937. In this paper an acoustical image is reconstructed with the power spectra analysed by impulse ultrasound wave generated by electrodynamic transducer(EDT). The EDT generates the impulse ultrasound of 77KHz in center frequency and 120KHz in bandwidth at -20dB by 1200V exciter in this experiment. The impulse ultrasound has the dominant frequency components of 47KHz, 177KHz, 110KHz and 155KHz. The U shape object is adopted in making an acoustical image. The resulted spectral acoustical images are different from the optical view of the U shape object. However the image reconstructed from 110KHz spectrum is very similar to the original optical shape of the object. Even KHz level impulse sound of 70$\mu$sec pulse width is found to be useful in reconstructing acoustical imaging improvement.

  • PDF

A study on the vest shape and tailoring of the Korean Empire in the 1900s (대한제국기 남자 조끼 형태 및 제작법에 관한 연구)

  • Choi, Eunjoo
    • The Research Journal of the Costume Culture
    • /
    • v.25 no.3
    • /
    • pp.340-358
    • /
    • 2017
  • The purpose of this study is to fundamentally examine the vests of the robes "Daeraebok" and "Soraebok" of the Korean Empire from the 1876 Port Opening to the 1910 annexation of Korea to Japan. Among the collections of different robes of the Korean Empire which belong to various universities and institutions, only the vests were surveyed. The shape of the vests in the Korean Empire were single-breasted and double-breasted. Most V-necklines and vests with a shawl collar look like a tailored collar, where the collar outline was shaped like a notched and picked collar, which is a mix of the step collar and roll collar of the 19th century. The rear center line was not flat, but inclined to a triangle. All vests of the robe Daeraebok were equipped with gold buttons, and those of the robe Soraebok had black satin buttons. The tailoring characteristic is that the front has a different material (dark black wool) from the back (black silk). This characteristic is expected to be an important basic piece of information in the restoration and reproduction of the vest, which was worn during the imperial period, especially to reveal its shape, characteristics and composition. This characteristic can also be used as data of cultural contents based on Korean modern history.

Microstructure and Electrical Properties of SnO2 Thin Films Grown by Thermal CVD Method (열 CVD법으로 증착된 SnO2 박막의 미세구조와 전기적 특성)

  • Jeong, Jin;Choi, Seong-Pyung;Shin, Dong-Chan;Koo, Jae-Bon;Song, Ho-Jun;Park, Jin-Seoung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.5
    • /
    • pp.441-447
    • /
    • 2003
  • When a SnO$_2$ thin film was deposited by thermal CVD, two different types of growth behavior that were dependent on the deposition temperature were observed. The film grown at 475$^{\circ}C$ had a wide grain size distribution and a faceted surface shape. On the other hand, the film grown at 5$25^{\circ}C$ had a relatively narrow grain size distribution and a rounded sulfate shape. The aspects of grain shape and growth behavior agree well with the theory of gram growth and a roughening transition. The charge tarrier density decreased with deposition time. According to photoluminescence measurements, the peak intensity of the spectra occurred at approximately 2.5 eV, which is related to oxygen vacancies, and decreased with increasing of deposition time. These measurement results suggest that the number of oxygen vacancies, which is related to the electrical conductivity, decrease with deposition time.

A Study on the Classification of the Women's Pants Silhouettes by Their Pattern Construction (여성 팬츠의 패턴 구조에 따른 스타일 분류)

  • Yoon, Mi-Kyung;Nam, Yun-Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.5
    • /
    • pp.741-751
    • /
    • 2009
  • In order to design and develop the various silhouette of pants pattern for standardized pants patterns, this study is to classify the pants style by the silhouette and to characterize each pants pattern which are classified. Recent 37 ready-made pants patterns of various style were collected in order to analyze their silhouette from April to July 2007. Measurement of each region of the pants pattern were compared and analysed. After analyse the standard deviation, coefficient of variance, minimum, maximum, range about the measurement of each region of the pants pattern, major pattern design factors were extracted. Five major factors are the angle of center front line and center back line, the crotch extension, the position of center back line against center front line, the curvature of center back line, and amount of waist dart. As a result, pants style were grouped as the culottes, formal, basic and tight style after considering the extracted design factors, and analysing correlation, degree of dispersion of the measurement by part. As the silhouette of pants classification from culotte to tight, the fits are closer to the figure, crotch depth increases, crotch extensions are shorter, and angle of the center back increases. The shape of the connected front and back center lines is U-shape for culotte and is closer to V-shape as the silhouette becomes tight.

Characteristics of Critical Pressure for a Beam Shape of the Anode Type ion Beam Source

  • Huh, Yunsung;Hwang, Yunseok;Kim, Jeha
    • Applied Science and Convergence Technology
    • /
    • v.27 no.4
    • /
    • pp.65-69
    • /
    • 2018
  • We studied the critical pressure characteristics of an anode type ion beam source driven by both charge repulsion and diffusion mechanism. The critical pressure $P_{crit}$ of the diffusion type ion beam source was linearly decreased from 2.5 mTorr to 0.5 mTorr when the gas injection was varied in 3~10 sccm, while the $P_{crit}$ of the charge repulsion ion beam source was remained at 3.5 mTorr. At the gas injection of 10 sccm, the range of having normal beam shape in the charge repulsion ion beam source was about 6.4 times wider than that in the diffusion type ion beam source. An impurity of Fe 2p (KE = 776.68 eV) of 12.88 at. % was observed from the glass surface treated with the abnormal beam of the charge repulsion type ion beam source. The body temperature of the diffusion type ion beam source was observed to increase rapidly at the rate of $1.9^{\circ}C/min$ for 30 minutes and to vary slowly at the rate of $0.1^{\circ}C/min$ for 200 minutes for an abnormal beam and normal beam, respectively.