• 제목/요약/키워드: V 화염

검색결과 79건 처리시간 0.025초

상호작용하는 대향류 메탄 및 수소 예혼합화염에서 당량비 조건에 따른 상호작용 모드 변화 (Interaction Mode Change According to the Equivalence Ratios in the Interacting Methane and Hydrogen Counterflow Premixed Flames)

  • 박지웅;오창보
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.13-16
    • /
    • 2012
  • The interaction between methane and hydrogen premixed flames with the different equivalence ratio and global strain rate was investigated numerically in one-dimensional counterflow field. The OPPDIF code and GRI-v3.0 were used to simulate the interacting flames. Overall trends in the maximum heat release rates of $CH_4{^-}$ and $H_2$-side flame were examined with the variation of $a_g$. The interaction mode of the flames were classified according to the equivalence ratios and Lewis numbers of each flame and global strain rate.

  • PDF

DC 코로나 방전이 적용된 에틸렌 정상 확산 화염의 Soot 배출 저감 (Reduction of Soot Emitted from a $C_2$$H_4$ Normal Diffusion Flame with Application of DC Corona Discharge)

  • 이재복;황정호
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.496-506
    • /
    • 2001
  • The effect of corona discharge on soot emission was experimentally investigated. Size and number concentrations of soot aggregates were measured and compared for various voltages. Regardless of the polarity of the applied voltage, the flame length decreased and the tip of flame spreaded with increasing voltage. For the experimental conditions selected, the flame was blown off toward the ground electrode by corona ionic wind. When the negative applied voltage was greater than 3kV(for electrode spacing = 3.5cm), soot particles in inception or growth region were affected by the corona discharge, resulting in the reduction of number concentration. The results show that the ionic wind favored soot oxidation and increased flame temperature. Number concentration and primary particle size greatly increased, when the corona electrodes were located the region of soot nucleation or growth(close to burner mouth).

블루사파이어와 루비의 고온산소 화염처리에 의한 색향상 (Color Enhancement by Oxygen Torch in Blue Sapphires)

  • 송오성;김상엽
    • 한국표면공학회지
    • /
    • 제38권2호
    • /
    • pp.83-87
    • /
    • 2005
  • We enhanced the color of blue sapphires and rubies successfully by using a oxygen-propane torch flame annealing, which had not been employed so far. We confirmed that about 1 mm-thick de-coloring of the corundum samples were available with 60 minutes flame annealing through eye evaluation, color coordination characterization, and methylene iodide immersion observation. We also suggest that the color centers such as $[Fe_{Al}^{\cdot}]$ may transform into transparent $[Fe_{Al}^{x}],\;[Cr_{A1}^{x}]$ sites with $[V_o^']$ generation at the elevated temperature in oxygen-rich atmosphere by diffusion mechanism. Our results implied that the longer diffusion time and the higher oxygen partial pressure might lead to the better de-coloring enhancement in corundum gem stones.

수직 평판 위에서 과소팽창 제트의 충돌

  • 이택상;신완순;이정민;박종호;김윤곤
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 1999년도 제12회 학술강연회논문집
    • /
    • pp.17-17
    • /
    • 1999
  • 충돌제트는 산업, 항공우주, 군사 분야 등 공학적으로 많은 분야에서 응용되고 있다. 산업분야에서 충돌제트는 설치가 간단하고 형태가 단순하면서도 열 및 물질 전달효과가 상당히 크기 때문에 고효율의 열전달 효과를 얻을 수 있다는 점에서 광범위하게 응용된다. 예를 들면 물체 표면의 부분냉각은 고온 금형의 급속 냉각, 가스터빈 깃의 냉각, 전자부품의 냉각 등에 이용되며 부분 가열에서는 제철, 제지 및 유리공업, 금형의 풀림 등에 폭 넓게 적용된다. 항공우주, 군사분야에서는 수직/단거리 이·착륙기(V/STOL)의 발진, 미사일 발사시스템, 다단 로켓의 분리, 우주공간에서의 도킹, 화염 편향기 등에 적용이 되며 대부분 평판이나 특수한 판의 형상에 과소 팽창제트가 충돌할 때 발생하는 현상에 대한 것이다.

  • PDF

이산화염소의 해산어류 병원세균 살균효과 (Disinfection Effect of Chlorine Dioxide on Pathogenic Bacteria from Marine Fish)

  • 박경희;오명주;김흥윤
    • 한국양식학회지
    • /
    • 제16권2호
    • /
    • pp.118-123
    • /
    • 2003
  • 이산화염소($ClO_2$) 처리에 의한 어병 세균의 살균 효과를 조사하기 위하여 감염어 유래 분리주인 Vibrio anguillarum, Edwardsiella tarda, Streptococcus sp. 및 Streptococcus sp.를 대상으로$ClO_2$유효 농도 0.455, 0.246 및 0.129 ppm에 30초, 1분, 3분, 5분 및 10분간 처리하여 ClO$_2$의 살균효과를 조사하였다. V. anguillarum과 E. tarda는 ClO$_2$ 0.246 ppm에서, 30초 이 상의 처리에 의하여 세균의 증식이 완전히 저해되었다. 그러나 상대적으로 저농도인 0.129 ppm에서는 5분 이상의 염소처리 조건이 필요하였다. Streptococcus sp.는 실험에 사용된 어병 세균 중 $ClO_2$의 살균능이 가장 낮은 것으로 나타났다. 0.455 ppm에서 Streptococcus sp.는 30초 반응 후 그 증식이 완전히 저해되었고, 0.246 ppm과 0.129 ppm의 ClO$_2$에서는 각각 배양 3시간, 8시간 이후부터 그 생잔에 의한 증식이 확인되어졌다. Streptococcus sp.는 본 실험에서 설정한 최저농도인 0.129 ppm 에 30초간의 반응으로 균이 사멸됨으로서 실험에 사용된 세균 중 ClO$_2$에 가장 민감한 것으로 나타났다. 그러므로 Streptococcus sp. 는 0.455 ppm, V. anguillarum과 E. tarda는 0.246 ppm, Streptococcus sp. 는 0.129 ppm의$ClO_2$농도로 30초 전후로 처리하는 조건이 가장 효과적임을 본 연구를 통해 확인할 수 있었다.

2.5 mm2 HIV에 일반화염 및 DC 단락 전류를 인가하여 생성된 기공의 정량적 분포 해석 (Quantitative Distribution of Created Voids by Applying General Flame and DC Short-circuit Current to 2.5 mm2 HIV)

  • 김승삼;최충석
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.38-42
    • /
    • 2013
  • This study performed the quantitative distribution analysis of created voids to an insulator when applying general flame and DC short-circuit current to 2.5 $mm^2$ HIV (600 V Grade Heat-Resistant Polyvinyl Chloride Insulated Wires). The diameter of cross-section of HIV normal product and the radius of conductor were measured to be 3.3 mm and 1.8 mm. The exterior of HIV exposed to general flame showed severe carbonization and its interior exhibited voids created by dechlorination reaction. This study observed the characteristics that, when the shortcircuit current applied for 2 seconds from a DC 12 V lead battery, the conductor and neighboring insulator were melted, causing the insulator adhering to the conductor. On average, 87 voids were created on 10 mm of the HIV. The average diameter of voids was 0.25 mm. In addition, it was found that, when the short-circuit current applied for 4 seconds, the interior of insulator in contact with conductor severely carbonized and showed exfoliation phenomenon. On average, 47 voids were created, with more voids at the bottom. The average diameter of voids was 0.20 mm. When the short-circuit current for 6 seconds, most parts of upper part of conductor was carbonized, 20 voids were created. The average diameter of voids was measured to be 0.24 mm. It could be seen that the created voids received little influence by the type of energy source and the number of created voids was reduced as the energy supply time increased.

부력을 최소화한 대향류 확산화염 소화거동에서 연료농도구배의 영향 (Influence of Fuel concentration gradient on the Extinction Behavior in Buoyancy minimized Counterflow Diffusion Flame)

  • 박진욱;박정;윤진한;길상인
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.379-381
    • /
    • 2014
  • Influence of fuel concentration gradient was investigated near flame extinction limit in buoyancy-suppressed non-premixed counterflow flame with triple co-flow burner. The use of He curtain flow produced a microgravity level of $10^{-2}-10^{-3}g$ in He-diluted non-premixed counter triple co-flow flame experiments. Flame stability map was presented based on flame extinction and oscillation near extinction limit. The stability map via critical diluent mole fraction with global strain rate was represented by varying outer and inner He-diluted mole fractions. The flame extinction modes could be classified into five: an extinction through the shrinkage of the outmost edge flame forward the flame center with and without self-excitation, respectively ((I) and (II)), an extinction via the rapid expansion of a flame hole while the outmost edge flame is stationary (III), both the outermost and the center edge flames oscillate, and then a donut shaped flame is formed or the flame is entirely extinguished (IV), a shrinkage of the outermost edge flame without self-excitation followed by shrinking or sustain the inner flame (V).

  • PDF

핀-핀 형 또는 판-판 형 전극에 인가된 AC 전기장이 에틸렌 정상 확산 화염 Soot 입자 배출에 미치는 영향 (Effects of AC Electrostatic Field Applied to fin-to-Pin/Plate-to-Plate Electrodes on Soot Reduction in a C2B4 Normal Diffusion Flame)

  • 이재복;황정호
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1062-1068
    • /
    • 2002
  • In our previous study, it was proven that the mean size and the total number concentration of carbon soot particles emitted from a $C_2$H$_4$ normal diffusion flame decreased when a DC corona was discharged to pin-pin electrodes. In this work the effect of AC corona discharge on soot emission was investigated and compared with that of DC corona discharge. For the pin-pin electrodes the size of soot particles and the number concentration decreased by the AC voltage. There were only slight changes in size distribution with frequencies, while the magnitude of applied voltage was constant. When the electric field was applied to plate-plate electrodes, the size and the number concentration also decreased with the applied AC voltages. For applied voltages above 2kV the effect of frequency increase on the soot emission was effective.

상호작용하는 대향류 메탄-수소 부분예혼합화염의 CO 배출특성 (CO Emission Characteristics in the Interacting Counterflow Methane and Hydrogen Partially Premixed Flames)

  • 박지웅;오창보;김태형;박종호
    • 한국연소학회지
    • /
    • 제17권3호
    • /
    • pp.1-8
    • /
    • 2012
  • The CO emission characteristics of interacting hydrogen and methane partially premixed flames were numerically investigated. A counterflow geometry was introduced to establish interacting two partially premixed flames. An one-dimensional OPPDIF code was used to simulate the interacting flames. The GRI-v3.0 was used to calculate the chemical reactions. Emission index for CO(EICO) was evaluated to quantify the CO emitted from the interacting flames. The global strain rate and equivalence ratios for each flame(${\Phi}_{CH_4}$ and ${\Phi}_{H_2}$) were used as parameters to control the extent of interaction between two partially premixed flames. When ${\Phi}_{CH_4}$ was kept to stoichiometric condition and ${\Phi}_{H_2}$ was at rich condition, unburned H2 species of hydrogen flame was transported to the methane flame and affected reactions related with CO formation. When ${\Phi}_{CH_4}$ increased from a stoichiometry to rich condition while ${\Phi}_{H_2}$ was kept to stoichiometric condition, EICO increased initially, had a peak value at ${\Phi}_{CH_4}=1.5$ and decreased gradually. This could be elucidated with an analysis for the elementary reactions related with CO formation.

LNG 연료 추진 선박용 크랭크실 릴리프 밸브 화염방지기의 유동해석 및 폭발시험 (CFD Analysis and Explosion Test of a Crankcase Relief Valve Flame Arrester for LNG-fuelled Ships)

  • 이효렬;안중환;김동건;안병훈;김화영
    • 한국생산제조학회지
    • /
    • 제25권3호
    • /
    • pp.171-176
    • /
    • 2016
  • Growing concerns about air pollution have led to increased demand for liquefied natural gas (LNG)-fuelled ships that have crankcases equipped with explosion relief valves to relieve excessive crankcase pressures and stop the flames emitted from the crankcase. The results of a computational fluid dynamics (CFD)-based feasibility analysis of the crankcase relief valve flame arrester design conducted using ANSYS CFX V14 showed that the inlet and outlet relief valve temperatures differed by $350-700^{\circ}C$. An explosion test was performed based on European standard EN14797 to evaluate the flame transmission and mechanical integrity of the valve. No flame transmission from the pressure vessel to the exterior was detected, and the mechanical integrity of the valve was confirmed. Thus, the relief valve components were found to be safe from the viewpoint of fracture.