• 제목/요약/키워드: Uv Camera

검색결과 64건 처리시간 0.018초

폰 카메라 모듈 자동 조립.평가시스템 설계 (Design of Automatic Assembly & Evaluation System for Phone Camera Module)

  • 송준엽;이창우;하태호;정연욱;김영규;이명철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.71-72
    • /
    • 2006
  • In this study, automatic assembly and evaluation system fer phone camera module is conceptually designed. The designed core(Auto focus & UV curing, Image Test) equipments adopts a clustering mechanism and compactible structure using index table for minimum tact time. Using a ball screw actuator and absolute encoder in each axis, we can verifies the repeatability and position accuracy of system within ${\pm}3{\mu}m$. In result of simulation test, the proposed system is expected up to 30% in productivity than manual operation.

  • PDF

디지털 자외선 사진을 위한 적정 디지털 카메라 시스템 (Appropriate Digital Camera System for Digital Ultraviolet Photography)

  • 이영규;하동환
    • 한국콘텐츠학회논문지
    • /
    • 제10권7호
    • /
    • pp.40-48
    • /
    • 2010
  • 자외선 사진은 범죄수사, 고고학, 피부의학 등 다양한 분야에서 활용되고 있다. 과거 자외선 사진은 일반적인 흑백필름을 이용하여 촬영하는 경우가 대부분이었는데, 그 이유는 필름의 감광유제로 사용되는 할로겐화은(AgX)성분이 카메라의 센서인 CCD(Charge Coupled Device)혹은 CMOS(Complementary Metal-Oxide-Semiconductor)에 비해 자외선에 민감하기 때문이다. 이에 본 논문에서는 보급형 디지털 카메라를 사용하여 자외선 사진의 화질을 개선시키고, 자외선 사진을 위한 최적의 디지털 카메라 특성을 찾는 것을 목적으로 하였다. 이를 위해 디지털 카메라의 적외선 차단 필터를 제거하고, 자외선 투과필터의 개조를 통해 자외선 사진의 화질향상 여부를 검증하였다. 또한 센서의 종류와 크기, 화소수에 따른 자외선 사진의 재현성을 화질측정 요소들을 통해 분석하였으며, 이를 통해 디지털을 이용한 자외선 사진에 가장 적합한 카메라 특성을 찾고자 하였다. 나아가 본 논문을 통해 일반 디지털 카메라를 활용한 자외선 촬영 시스템을 구축할 수 있을 것이며, 이는 결국 디지털 자외선 사진의 폭넓은 활용에 기여할 것으로 기대된다.

Camera Imaging Lens Fabrication using Wafer-Scale UV Embossing Process

  • Jeong, Ho-Seop;Kim, Sung-Hwa;Shin, Dong-Ik;Lee, Seok-Cheon;Jin, Young-Su;Noh, Jung-Eun;Oh, Hye-Ran;Lee, Ki-Un;Song, Seok-Ho;Park, Woo-Je
    • Journal of the Optical Society of Korea
    • /
    • 제10권3호
    • /
    • pp.124-129
    • /
    • 2006
  • We have developed a compact and cost-effective camera module on the basis of wafer-scale-replica processing. A multiple-layered structure of several aspheric lenses in a mobile-phone camera module is first assembled by bonding multiple glass-wafers on which 2-dimensional replica arrays of identical aspheric lenses are UV-embossed, followed by dicing the stacked wafers and packaging them with image sensor chips. This wafer-scale processing leads to at least 95% yield in mass-production, and potentially to a very slim phone with camera-module less than 2 mm in thickness. We have demonstrated a VGA camera module fabricated by the wafer-scale-replica processing with various UV-curable polymers having refractive indices between 1.4 and 1.6, and with three different glass-wafers of which both surfaces are embossed as aspheric lenses having $230{\mu}m$ sag-height and aspheric-coefficients of lens polynomials up to tenth-order. We have found that precise compensation in material shrinkage of the polymer materials is one of the most technical challenges, in orderto achieve a higher resolution in wafer-scaled lenses for mobile-phone camera modules.

기중 부싱모델의 오염물질에 따른 방전 특성과 자외선 이미지 (Discharge Characteristics and UV Images at Air on Bushing Model with Contaminations)

  • 방만식;최재형;김우진;김영석;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제24권12호
    • /
    • pp.996-1001
    • /
    • 2011
  • A bushing is very important because it must supply the high voltage to the power equipment. Generally, the surface of bushing is contaminated with rain, dust, salt and others. A bushing with contaminations at air are serious problem in insulation. Therefore, it is important to understand the inspection and diagnoses of the safety. The ultra-violet rays(UV) camera has attracted interest from the view point of easy judgement. In this paper, we will report on the corona discharge characteristics on bushing model with contaminations. Also, UV images of discharge in air are analyzed using prototype UV camera of Korea. These results are studied at both AC and DC voltage under a non-uniform field.

자외선 검출 카메라를 이용한 전력시스템의 안전진단에 관한 연구 (A Study on the Safety Diagnosis for Power Systems Using a UV Camera)

  • 유병열;김찬오
    • 한국안전학회지
    • /
    • 제27권1호
    • /
    • pp.7-13
    • /
    • 2012
  • This paper describes the diagnosis techniques using UV images taken in the field under energized condition of power equipments in order to figure out and analyze the abnormal states on the terminals of power equipments. To classify the features of the terminals, the counted No. of the corona generated at the terminals is defined. According to the result detected, the No. of corona detected on the power equipments installed inside a building is less than that installed outside a building, and it strongly depends on the environment and installed condition. Thus, the environmental condition needs enhanced, and stable operation by the periodic inspection under energized condition of the power equipments is required. Especially, the event counting technique using UV camera is useful for the power equipments apart more than 20 m to apply, and there can be an error due to the features of the sensing techniques when the distance between the user and the objects is close less than 15 m. Therefore, the experimental result shows that event counting technique is employed in the case of the distance more than 15 m. The electrical safety can be ensured by using the UV detection technique and the criteria.

자외선 검출이미지를 이용한 폴리머 애자의 연면방전 특성해석 (An Analysis on Characteristics of Surface Discharge on Polymer Insulator Using UV Detected Images)

  • 송길목;김영석;박상택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.313-314
    • /
    • 2009
  • In this paper, it's described the UV detected images on polymer insulators using UV camera. The patterns of UV detected images are classified into 3 types such as jellyfish(J), amoeba(A), sunflower(S). J type is detected by high electric field in air A type is detected by early surface discharge. And, S type is detected by the serious problem in surface of insulator.

  • PDF

Preventing Method against the Occurrence of a Corona between a Dead End clamp and a Porcelain Insulator Used in 154kV Substation

  • Han, Woon-Ki;Choi, Jong-Soo;Lee, Jun;Kim, Jae-Chul
    • International Journal of Safety
    • /
    • 제6권2호
    • /
    • pp.22-26
    • /
    • 2007
  • An episode of corona is a heterogeneity-caused electric discharge that occurs when electric fields are formed layer on layer and concentrated on an electrode. Electric wires built at the tip of 154kV private facilities use dead end clamp spawns corona from homogeneity caused by field concentration. Corona induces power loss, noise, insulator failure and more. In this research, we've studied the characteristics of coronas that take place in porcelain insulators and terminal electric wires of supporting hard wares (dead end clamp) that are set up as spares in the 154kV private facilities use hydroelectricity installations to support electric wires. Corona, which cannot be identified by regular methods, was measured utilizing UV image camera. As the result of measuring corona via UV image camera, we've confirmed that the depletion of insulators was accelerated following the wire end treatment method and validated the stress intensity of insulators at various lengths of bare wires caused by electric fields via FEMLAB. We have also proposed a new model for relieving homogeneity-caused field concentration, and after analyzing the proposed model via FEMLAB, we've confirmed that the concentration of field distribution was indeed reduced. Such results are exploited in installation of private facilities use equipments, maintenance of insulators and hard wares as well as safety enhancement, and are anticipated to be effectively utilized in corona prevention measures.

UV 센서 어레이를 이용한 폴리머 애자의 코로나 방전 신호분석 연구 (A Study on the Signal Analysis of Corona Discharge on the Polymer Insulator using UV Sensor Array)

  • 최명일;김재철
    • 조명전기설비학회논문지
    • /
    • 제28권4호
    • /
    • pp.16-20
    • /
    • 2014
  • To prevent any accident in electric power utilities, many researches for inspection and diagnosis deteriorations occurring by corona discharges have been continuously studying. Inspection and diagnosis of electric power utility is very important to prevent an accident. This paper studies a measurement of ultra-violet(UV) ray of corona discharges on polymer insulators using an UV sensor array with an optic lens. The detection of an UV signal begins at 60kV, which is about 37.5% of the breakdown voltage of the polymer insulator and the stronger the high voltage increased to the polymer insulator was. It can be determined that the polymer insulator mounted on a live part must be examined when the discharge risk exceeds approximately 40%. In conclusion, the status of power utilities can be checked using an UV sensor.

지폐검사를 위한 UV 패턴의 자동추출 (Automatic Extraction of UV patterns for Paper Money Inspection)

  • 이건호;박태형
    • 한국지능시스템학회논문지
    • /
    • 제21권3호
    • /
    • pp.365-371
    • /
    • 2011
  • 최근에 발행되는 대부분의 지폐는 UV(ultra violet)조명에 반응하는 UV패턴을 포함한다. 본 논문은 지폐검사를 위하여 지폐 내부에 존재하는 UV패턴을 자동으로 추출하는 방법을 제안한다. UV조명을 이용하여 촬영한 영상을 전 처리 과정을 통하여 입력데이터로 변환시킨 후, 가우시안 혼합 모형과 split-and merge EM(SMEM)알고리즘을 적용하여 영상을 몇 개의 영역으로 분리시킨다. 영역 분리된 영상 중 원하는 패턴을 추출하기 위하여, 공분산 벡터의 넓이와 가중치를 이용하는 방법을 새로이 제안한다. 다양한 지폐에 대한 실험을 통하여 제안방법의 유용성을 보인다.

Characteristics of a Corona between a Wiring Clamp (Dead End Clamp) and a Porcelain Insulator Used in a 154kV Power Receptacle

  • Han, Woon-Ki
    • International Journal of Safety
    • /
    • 제7권1호
    • /
    • pp.21-25
    • /
    • 2008
  • The occurrence of a corona is that electrical discharge due to the heterogeneity that occurs when an electrical field is concentrated in an electrode due to a cusp formed on said electrode. Wire treatment at the end of a 154kV dead end clamp for end users accelerates the occurrence of corona, which in turn leads to power loss and noise. In this study, the characteristics of the corona which occurs between porcelain insulators and support clamps of overhead lines used in l54kV power receiving facilities for end users were investigated. The corona, which cannot be identified by one common method, was measured utilizing a UV image camera. A risk assessment for fire damage and its status was suggested. The stress distribution of the electrical field by length of bare wire was suggested by means of the finite element method (FEMLAB). As a result, it was found to affect a porcelain insulators. These results can be utilized for the enhancement of clamp installation and safety in power facilities.