• 제목/요약/키워드: Utility-reduction

검색결과 196건 처리시간 0.036초

특고압 수용가의 전력품질 측정 및 분석 (Power Quality Measurement and Analysis of Extra-High Voltage Customer)

  • 조재형;이종필;지평식
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.286-290
    • /
    • 2015
  • Power system is composed of a number of power devices and equipment. This factor affects the power quality is also displayed very complicated and varied. The accurate measurement and analysis of the causes of power quality problems is difficult. In preparing for these issues, there are many difficulties. In this study, Power quality of A public establishment of Chungbuk province were measured and analyzed. Measurement results of the fifth harmonic current was very large. Accordingly, the harmonic reduction will be needed. This research will be utilized as fundamental data to improve power quality for power utility and customer.

계통연계형 인버터의 왜곡된 계통전압에 의해 발생하는 전류고조파 저감방법 (Reduction Method of Harmonic Current by Distorted Grid Voltage in the Grid-connected Inverter)

  • 목형수;최규하;이정민;김상훈;지준근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.108-111
    • /
    • 2007
  • Phase angle in grid-connected inverter is important information for current control. When different loads are connected to PCC(Point of Common Coupling) of grid, distorted grid voltage is taken place by load utility generating distorted current. Especially, in case the grid voltage is distorted by low order frequency such as $3^{rd}$, $5^{th}$ harmonic, phase angle of PLL output is distorted. This paper analyze problem of current THD(Total Harmonic Distortion) due to distorted phase angle by distorted grid voltage, and propose control method compensating this problem. Also, it‘s validity is verified by simulation and experiment.

  • PDF

배전계통에서 위상조정 변압기를 사용한 고조파 저감에 관한 연구 (A Study on the Harmonics Reduction using Phase Shifting Transformer in a Electric Power Distribution System)

  • 김경철
    • 조명전기설비학회논문지
    • /
    • 제16권2호
    • /
    • pp.38-44
    • /
    • 2002
  • 전력변환기와 같은 비선형 부하의 사용증가는 전력시스템에 고조파를 발생시킨다. 고조파를 포함하는 전류와 전압은 전기설비에 고장과 오동작을 일으키게된다. 위상조정 변압기는 고조파 발생원이 병렬로 설치되어 있는 곳에 설치하면 고조파 문제를 효과적으로 해결할 수 있다. 본 논문에서는 EDSA고조파 분석 프로그램을 사용하여 고조파를 제거하기 위한 위상조정 변압기의 효과를 분석하고 검증하였다.

소형디젤기관에서 황함유량에 따른 SOx 및 PM저감에 관한 실험적 연구 (An Experimental Study on SOx and PM Reduction by Sulfur Content in Light Duty Diesel Engine)

  • 한영출;오용석
    • 한국대기환경학회지
    • /
    • 제14권4호
    • /
    • pp.387-392
    • /
    • 1998
  • Recently, among after-treatment devices which have high possibility of utility, diesel oxidation catalyst (DOC) is concerned over the world. DOC oxidizes pollutants by means of activate-reaction during by -passing in the catalyst, in doing so, conversion efficiency of PM, CO and HC is high, and this device does not have an effect on engine performance because back pressure is not nearly increased. But, as a small amount of sulfur content in fuel is oxidized, it makes sulfate, which is absorbed on the surface of catalyst. So, in this study, the experiment is carried out by means of using ordinary fuel (0.1wt%) and low sulfur fuel (0.05wt%) with DOC, and the emission gas of diesel engine is measured.

  • PDF

전력변환장치를 포함한 전력시스템에서 동조 필터를 이용한 고조파 저감 효과의 분석에 관한 연구 (A Study on the Analysis of Harmonics Reduction Effects Using Single-tuned Filters In a Power System Included Power Converters)

  • 최홍규;김경철;강태은;전기원
    • 조명전기설비학회논문지
    • /
    • 제14권3호
    • /
    • pp.81-87
    • /
    • 2000
  • 전력변환기와 같은 비선형 부하의 사용증가는 전원 전력설비시스템에 고조파을 발생시킨다. AD/DC 변환설비는 전력시스템에서 중요한 고조파 발생원이 되고 있다. 고조파를 포함하는 전류와 전압은 전기설비에 고장과 오동작등과 같은 나쁜 영향을 미친다. 고조파 문제를 해결하는 일반적인 방법으로는 고조파 필터룹 사용한다. 본 논문에서는 EDSA 고조파 분석 프로그램을 사용하여 고조파를 제거하는 동조필터를 설치하여 그 효고를 검증하였다.

  • PDF

Multi-station Fixture Layout Design Using Simulated Annealing

  • Kim, Pansoo;Seun, Ji Ung
    • Management Science and Financial Engineering
    • /
    • 제10권2호
    • /
    • pp.73-87
    • /
    • 2004
  • Automotive and aircraft assembly process rely on fixtures to support and coordinate parts and subassemblies. Fixture layout in multi-station panel assemblies has a direct dimensional effect on final products and thus presents a quality problem. This paper describes a methodology for fixture layout design in multi -station assembly processes. An optimal fixture layout improves the robustness of a fixture system against environmental noises, reduces product variability, and eventually leads to manufacturing cost reduction. One of the difficulties raised by multi-station fixture layout design is the overwhelmingly large number of design alternatives. This makes it difficult to find a global optimality and, if an inefficient algorithm is used, may require prohibitive computing time. In this paper, simulated annealing is adopted and appropriate parameters are selected to find good fixture layouts. A four-station assembly process for a sport utility vehicle (SUV) side frame is used throughout the paper to illustrate the efficiency and effectiveness of this methodology.

Dimmer 회로에서의 고조파 발생과 저감에 관한 연구 (A Study on harmonics generation and reduction in Dimmer circuits)

  • 박석훈;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.252-254
    • /
    • 2000
  • For many years, electric utility has used sustained interruption rates as a reliability index. Today, however, many electricity consumers are adversely affected by more subtle voltage disturbances such as harmonic distortion. This paper deals with observations of events that occur in the Dimmer circuits and phase control which could affect harmonics problem to the commercial power system. In order to reduce the effect of harmonics and design filters, Solid State Relay Dimmer(SCRs or TRIACs) and Noise Filter are described, and the effects of harmonics is also analyzed. IGBT Dimmer which is appropriate method to reduce harmonics and improve efficiency is introduced.

  • PDF

고강도 철근콘크리트 유공보의 역학적 거동에 관한 실험적 연구 (An Experimental Study on Mechanical Behavior of High Strength Concrete Beam with Circular Opening)

  • 구범모;박강근;윤승현;김용태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.609-614
    • /
    • 2000
  • This paper is an experimental study of the normal strength concrete beam and high strength concrete beam for the analysis of bending and shear behavior. In building structure, the story height can be minimized by providing openings in beams which serves for the utility equipments passing through. The dead space in false ceiling increase construction cost, the good ceiling system such as beam with opening give to economical merits because of a substantial reduction in materials and construction cost. For the analysis on the mechanical behavior of the reinforced high strength and normal strength concrete beams with circular opening in the web, the stress concentration of the circular opening, crack pattern and reinforcing methods were studied. Twenty test pieces with different reinforcing methods and difference concrete strength were tested and their resisting forces and load deflection curves were defined in this study.

  • PDF

고조파 주입 펄스 폭 변조를 이용한 3상 부스트 정류기의 고조파 저감 (Harmonic Reduction of Three-Phase Boost Rectifier using a Harmonic- Injected)

  • 이준구;김진성;박석하;김종범;김광수;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2736-2738
    • /
    • 1999
  • Power electronic loads inject harmonic currents into the utility system. The large increase of power consumption will inevitably lead to deteriorating power quality due to the popularization of switch-mode power electronic equipment. In this paper, a periodic voltage is injected in the control circuit to vary duty cycle of the rectifier switch within a line cycle so that the fifth-order harmonic of the input current is reduced to meet the IEC 61000-3-2 requirement. Experimental results are presented to confirm the validity of this method.

  • PDF

배전자동화시스템의 도입이 배전계통신뢰도 향상에 기여한 사례 연구 (A Study on the Improved Efficiency of Distribution Network Reliability Using DAS)

  • 황우현;배성환;김자희;김재철
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2059-2064
    • /
    • 2007
  • This paper analyzed distribution network reliability related with the increment of outages and duration time according to distribution facilities increasing. KEPCO introduced distribution automation system in 1998 which could recognize outage section by remotely monitoring the fault current and reduce the blackout area by remotely controlling distribution switches. As the result of this outage time reduction using distribution automation system, the minimum distribution automation rate was fined out in this paper on the base of analyzing diverse data and how many switches were used in distribution system to improve distribution network reliability at the situation of distribution facilities increasing. This result can be used as the model that an overseas utility company applies distribution automation system in the future.