• Title/Summary/Keyword: Utility interconnected PV system

Search Result 6, Processing Time 0.022 seconds

A study of on the Efficiency Analysis for 3kW Utility interactive PV System (3kW 태양광발전시스템의 효율분석에 관한 연구)

  • Park, J.M.;Lim, H.W.;Choi, Y.O.;Lee, S.G.;Cho, G.B.;Baek, H.N
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.61-63
    • /
    • 2005
  • Utility interactive photovoltaic systems is one of the most premising applications of photovoltaic systems. These systems are employed in applications where utility service is already available. In this case, there is no need for battery storage because utility power may be used to supplement photovoltaic systems when the load exceeds available PV generation. The load receives electricity from both the photovoltaic array and the utility inter-tied. In this paper, Principle and operating characteristic of Utility Interconnected Photovoltaic System is presented. For the purpose of optimal utility Inter-tied photovoltaic system design and installation. It is that demonstrate throughout the installed 3 PV system respectively, 3kW utility interconnected residential system.

  • PDF

Implementation of the 50kW Utility Interconnected Photovoltaic System Simulator (50kW급 계통연계형 태양광발전시스템의 시뮬레이터 구현)

  • Jeong, Byeong-Ho;Park, Jeong-Min;Cho, Geum-Bae;Baek, Hyung-Lae;Chung, Soo-Bok
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.21-27
    • /
    • 2005
  • This paper summarizes the results of these efforts by offering a photovoltaic system structure in 50kW middle scale applications installed in Cho-sun University dormitory roof. The combination of photovoltaic system components are interconnected and system monitoring system will be summarized for the purpose of the increasing safety in this article. This paper describes configuration of utility interactive photovoltaic system which generated electric power supplies to dormitory. In order to installing the middle or large scale photovoltaic system, It must investigated the optimal design of system, compute quantity of power generation, economic rate of return and so on. In this paper represent 50kW utility photovoltaic system examination and developed simulation results. The performance of photovoltaic system has been evaluated and analyzed with simulation. The results obtained in this research will be much useful to prior investigation for installing utility interactive photovoltaic system.

The Operating Characteristics of 3kW Utility Interconnected Photovoltaic System (3kW 계통연계형 태양광발전시스템의 운전특성)

  • Kim, Hyung-Seok;Park, Jeong-Min;Na, Jong-Deok;Baek, Hyung-Rae;Cho, Geum-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.201-204
    • /
    • 2004
  • Consider the optimal design for PV system, it is apply to 3kW interconnected electric power PV system, that is a point of reference for 3kW PV the spread residential section system. Through the driving various practical system, we look into that for efficiency of generation and stability of interconnected system. Using obtained data acquisition, It can be suggest that installation and management for system parameter to optimal design maximum generation electric power. PV system have some losses that are variation radiation, shadow, change temperature, unbalanced grid connection, serial circuit loss, MPP deference loss, PCS loss and so forth. Using obtained various performance characteristic result, we can make database in the future, through the this study, we can get the reliance and have regard to spread PV system.

  • PDF

Implementation of the 50kW Utility Interconnected PV System Simulator and the Study of Financial Analysis (50kw급 PV시스템 시뮬레이터의 구현 및 경제성 분석에 관한 연구)

  • Lee, K.Y.;Kim, Y.G.;Shin, S.D.;Kim, H.G.;Chun, H.S.;Kim, B.C.;Min, W.K.;Kim, N.O.
    • Proceedings of the KIEE Conference
    • /
    • 2008.11b
    • /
    • pp.157-159
    • /
    • 2008
  • This paper summarizes the results of these efforts by offering a photovoltaic system structure in 50kW. The combination of photovoltaic system components are interconnected and system monitoring system will be summarized for the purpose of the increasing safety in this article. This paper describes configuration of utility interactive photovoltaic system which generated electric power supplies to dormitory. In order to installing the middle or large scale photovoltaic system, It must investigated the optimal design of system, compute quantity of power generation, economic rate of return and so on. In this paper represent 50kW utility photovoltaic system examination, developed simulation results and financial analysis. The performance of photovoltaic system has been evaluated, analyzed with simulation and financial analysis results. The results obtained in this research will be much useful to prior investigation for installing utility interactive photovoltaic system.

  • PDF

A Study on the Performance Analysis of the PV-AF System under various Irradiation Conditions (다양한 일사량 조건에서의 PV-AF 시스템의 특성에 관한 연구)

  • Seo, Hyo-Ryong;Kim, Kyung-Hun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.212-213
    • /
    • 2007
  • Grid-connected PV(Photovoltaic) power generation system has experienced increasing attention in recent years. But the growing number of non-linear equipments, such as, inverters, has been demanding the compensation for the disturbances caused by them. These non-linear loads may cause poor power factor and high degree of harmonics. Installation of an AF(active filter) can be one of the solutions to mitigate the line distortion, but it requires additional costs. On the other hand, many PV systems have been interconnected to the distribution system. So, the PV system combined with the function of the active filter system can be useful for the application in the power distribution system. In this paper, PV-AF system using DSP (Digital Signal Processing) controller confirmed that it is possible to combine the AF theory to the three phase PV system connected to the utility under various irradiation conditions.

  • PDF

A Study on the Operating Characteristics for the Grid Interconnected PV System with BESS (BESS를 적용한 계통연계형 PV시스템의 운전특성에 관한 연구)

  • Lee, Kang-Yeon;Jeong, Byeong-Ho;Cho, Geum-Bae;Baek, Hyung-Lae;Jung, Hae-Duck
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.2
    • /
    • pp.69-77
    • /
    • 2006
  • Photovoltaic is an attractive technology to remote power applications, because of its reliability, low maintenance, and zero fuel requirements. In this paper represents residential PV system based on BESS(battery energy storage system) for managing the electric power, a pattern of daily operation considering the load characteristics of the house, the generation characteristics of PV power, and utility power leveling. For apply to control algorithm, we consider the load on monthly power consumption trend and daily usage pattern. As for the control of the proposed system, to increase the conversion efficiency of the PV power, bidirectional converter is used for MPPT and SPWM inverter. An experimental system is implemented, and some experimental results are provided to demonstrate the effectiveness of the proposed system.