Advances in Li-ion Batteries

  • Lee, Se-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.51.2-51.2
    • /
    • 2010
  • Efficient and durable electrical energy storage is one of the major factors limiting the wide-spread adoption of renewable energy. Since lithium-ion batteries (LIBs) were first commercialized in the early 1990s, LIBs have emerged as an important energy storage device for portable electronics. LIBs are very desirable because of their high energy storage per volume and per mass. However, LIBs with high energy and power as well as higher stability are needed for their use in a variety of energy storage applications such as MEMS devices, PDA, plug-in hybrids, all-electric vehicles and large scale utility systems. In this talk, I will discuss present energy perspective, especially energy storage and its role in renewable energy. After that I will discuss the recent advances in nanostructured materials and interface engineering that have led to the achievement of improved Li-ion batteries. Finally I will talk aboutcritical issues that need to be addressed to obtain further improvements in Li-ion batteries.

  • PDF

Development of the Simulation Model of Micro-Grid using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 마이크로그리드의 시뮬레이션 모델 개발)

  • Son, Kwang-M.;Lee, Kye-B.;Hong, Jun-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.457-464
    • /
    • 2007
  • Micro-Grid comprising Micro-Sources supplying several $kW{\sim}MW$ power to local customers is environmentally friendly and reliable. This paper deals with the development of simulation models of Micro-Grid on the PSCAD/EMTDC platform for analyzing various aspects of the interaction of the Micro-Grid. The developed switching level model adopts the space vector PWM. Both switching level and power frequency Micro-Source models are developed, which shows that power frequency modeling is sufficient for analyzing the phenomena of interest. Control characteristics of the Micro-Sources with the parameter and load power variation are analyzed for power quality enhancement. The simulation results show that the developed models are effective for studying Micro-Grid.

DC/AC converters for the power generating system using fuel cell (연료전지 발전 시스템의 직류/교류 변환기)

  • Kim, Y.H.;Kwon, G.H.;Kim, J.S.;Jung, Y.H.;Choi, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1035-1037
    • /
    • 1992
  • Generally, fuel cell has characteristics of low voltage, large current and voltage variation under load change. Therefore, DC output voltage of fuel cell is too low to convert into AC with high efficiency and good performance. For this reason, fuel cell generating system is composed of DC-DC converter and inverter in cascade. This paper used 2-phase boost DC-DC converter to obtain low distortion waveform and reduce input-output current ripple, and discussed inverter which can be operated in independent drive mode and utility line interface drive mode. Then, the change of modes can be achived smoothly.

  • PDF

Micro-Grid System Analysis (마이크로그리드 시스템 해석)

  • Son, Kwang-M.;Lee, Kye-B.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.280-282
    • /
    • 2005
  • Micro-source units having power ratings in thousands of watts can provide even higher reliability and fuel efficiency than the conventional large scale units. These units are also clustered with loads creating micro-grid services to customer sites such as office buildings, industrial parks and homes. Micro-sources adopt voltage source inverter to ensure the power quality of sensitive loads. This paper deals with the connection of micro-sources into the system grid. Modeling and simulation of the grid connected micro-sources at the power frequency range are investigated. Simulation results show that the micro-grid system with two micro-sources has good dynamic characteristics.

  • PDF

Performance Evaluation with Protective Function test of Inverter for Solar Power Generation (태양광발전용 인버터 보호기능시험 성능평가)

  • Yoon, Yong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.

History of Psychosomatic Medicine Revisited (정신신체의학 역사의 재조명)

  • Jeong, Do-Un
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.1 no.1
    • /
    • pp.3-13
    • /
    • 1993
  • Since the onset of modern psychosomatic medicine decades ago. it has made significant at contribution to general medicine in terms of understanding the patient as a whole person suffering from an illness rather than as a disease per se. However, initial expectation of delineating specific psychogenesis and developing specific treatment modality has not been fulfilled. Consequently, it has raised substantial concern about the continuing utility of psychosomatic medicine in modem medicine. The author attempted to review critically the evolution of psychosomatic medicine from the perspective of the present and to make projections into the near future. It is concluded that psychosomatic medicine in the future will continue to contribute to development of modem medicine not only as the scientific principle but also as the practical methodology, working as creative interface among disciplines and fusing ideas from rapidly developing molecular biology and neuroscience with psychosomatic concepts. Finally, suggestions for further developing psychosomatic medicine in Korea are made.

  • PDF

Development of Internet Web Program for the Calculation of OPF and Congestion Cost (전력거래에서 최적조류계산과 혼잡비용 계산을 수행하는 인터넷 웹 프로그램 개발)

  • Lee, Kwang-Ho;Jung, Jae-Ok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.6
    • /
    • pp.259-264
    • /
    • 2001
  • The electric utility industry around the world is undergoing a revolutionary transition from vertically integrated monopoly structures to a competitive structures. Competition in an open transmission access(OTA) makes the market participants access easily the transmission system in a non-discriminatory and equitable manner. The competitions of suppliers and customers make the electric market price change every hour. This paper presents a web program in the internet environment with a function of optimal power flow(OPF) calculation. The Web program gives the nodal marginal cost and the congestion charge using the shadow prices resulted from OPF. This web program is realized by a Perl and JAVA languages, and using the common gateway interface(CGI).

  • PDF

Characterization of Silk Fibroin/S-carboxymethyl Kerateine Surfaces: Evaluation of Biocompatibility by Contact Angle Measurements

  • Lee, Kuen-Yong
    • Fibers and Polymers
    • /
    • v.2 no.2
    • /
    • pp.71-74
    • /
    • 2001
  • Surface characterization of materials has been considered critical in the development of biomaterials, as many unfavorable responses from the body occur at the interface between a material and the body component. The contact angle measurement is one means to characterize the surface properties and to correlate them to the biocompatibility of materials. In this paper, surface characteristics of silk fibroin/S-carboxymethyl kerateine, representative fibrous proteins, were investigated by contact angle measurements of ESCA. The biocompatibility of the blends was evaluated based on minimal interfacial free energy concept, and compared with other potential biomaterials. It was also hypothesized that the enhanced surface polarity of the blends was generated from the conformational transition of proteins. This approach to evaluate the biocompatibility of materials based on surface characteristics may find wide utility in many biomedical applications.

  • PDF

Usability Study on Public Access Defibrillator (공공설치용 자동제세동기의 사용성 연구)

  • Oh, Young-Jin
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.1
    • /
    • pp.61-66
    • /
    • 2009
  • Usability study of the CU Medical "i-PAD" AED was conducted to validate the usability of the device, primarily focused on the trained user as well as the utility of the training material. Comparing these results of the trained participants to those obtained by Callejas et al. (2004), who studied video-trained users of two commercially available Philips AEDs (FR2 and HS1) using a male manikin only, the participants in this study were more successful (100% vs. 85.7%-FR2 vs. 88.9%-HS1) and faster to shock (58.5s-i-PAD vs. 91s-FR2 vs. 90s-HS1). While the focus of this study was on validating ease of use for trained bystanders, the results of the untrained condition showed that, from a usability perspective, these devices perform as well as any other AEDs already approved and available for purchase for untrained bystander use, as evidenced by the comparison to various published research results.

Transformer-less Type Grid-Connected PV Power Conditioning System (변압기 없는 계통연계형 PV PCS고찰)

  • Jung, Young-Seok;Yu, Gwon-Jong;Jung, Myoung-Woong;Choi, Jae-Ho;Choi, Ju-Yeop
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.551-554
    • /
    • 2002
  • This paper describes a new interactive inverter between a photovoltaic(PV) array and single-phase utility that avoid the bulky input (60Hz) transformer on the AC side. The interface employs a pwm boost converter on the DC side followed by a pwm current-forced single-phase rectifier for injecting the power from the PV array into the mains. The current waveform at the AC side remains sinusoidal and exactly in phase at all time. The circuit also has the advantage of requiring fewer switching device than high-frequency link system. This paper describes modeling of PV array and new system topology. Simulation results on the performance of the connection are also presented.

  • PDF