• Title/Summary/Keyword: Using analysis

Search Result 135,861, Processing Time 0.155 seconds

Analysis of the Dose Distribution of Moving Organ using a Moving Phantom System (구동팬텀 시스템에 의한 움직이는 장기의 선량분포 분석)

  • Kim, Yon-Lae;Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Lee, Gui-Won;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purpose: Few researches have been peformed on the dose distribution of the moving organ for radiotherapy so far. In order to simulate the organ motion caused by respiratory function, multipurpose phantom and moving device was used and dosimetric measurements for dose distribution of the moving organs were conducted in this study. The purpose of our study was to evaluate how dose distributions are changed due to respiratory motion. Materials and Methods: A multipurpose phantom and a moving device were developed for the measurement of the dose distribution of the moving organ due to respiratory function. Acryl chosen design of the phantom was considered the most obvious choice for phantom material. For construction of the phantom, we used acryl and cork with density of $1.14g/cm^3,\;0.32g/cm^3$ respectively. Acryl and cork slab in the phantom were used to simulate the normal organ and lung respectively. The moving phantom system was composed of moving device, moving control system, and acryl and cork phantom. Gafchromic film and EDR2 film were used to measure dose ditrbutions. The moving device system may be driven by two directional step motors and able to perform 2 dimensional movements (x, z axis), but only 1 dimensional movement(z axis) was used for this study. Results: Larger penumbra was shown in the cork phantom than in the acryl phantom. The dose profile and isodose curve of Gafchromic EBT film were not uniform since the film has small optical density responding to the dose. As the organ motion was increased, the blurrings in penumbra, flatness, and symmetry were increased. Most of measurements of dose distrbutions, Gafchromic EBT film has poor flatness and symmetry than EDR2 film, but both penumbra distributions were more or less comparable. Conclusion: The Gafchromic EBT film is more useful as it does not need development and more radiation dose could be exposed than EDR2 film without losing film characteristics. But as response of the optical density of Gafchromic EBT film to dose is low, beam profiles have more fluctuation at Gafchromic EBT. If the multipurpose phantom and moving device are used for treatment Q.A, and its corrections are made, treatment quality should be improved for the moving organs.

  • PDF

Ultrasound-Guided Local Steroid Injection Therapy for Acute Calcific Tendinitis of Shoulder (초음파를 이용한 급성 극상근 석회화 건염의 스테로이드 국소 주사 요법)

  • Kim, Jung-Man;Nam, Ho-Jin;Ra, Ki-Hang;Kang, Min-Ku
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.85-89
    • /
    • 2009
  • Purpose: To analyze the clinical outcome after ultrasound guided multiple dry needlings and local steroid injection for acute calcific tendinitis of shoulder. Materials and Methods: Twenty patients with acute episode of pain by calcific tendinitis of shoulder with average age 58.2 (50~70 years) and follow-up of 18 months in average (range, 12~24) were included in study. There were 18 patients with right and 2 with left sided involvement. All patients had calcific deposits in the supraspinatus tendon. All patients underwent standardized nonoperative treatment protocol, consisting of 5~12 MHz high resolution ultrasound guided multiple dry needlings with 18 guage needle, followed by 2% lidocaine 1cc and 40 mg/ml depomedrol 1cc injection at site of calcific tendinitis. The outcome was assessed by UCLA shoulder score, range of motion and VAS score. A statistical analysis with ANOVA and Tukey's post-hoc test with the significance level at 5% was performed using SAS 9.1 software (SAS Institute, Cary, NC). Results: All patients got continuous relief of pain right after the procedures until final follow-up. Before the procedures, the UCLA scores were fair in 15 patients and poor in 5. After the procedures, the UCLA scores were excellent in 16 patients and good in 4. All cases revealed no limitation of shoulder function. The average VAS score decreased from 8.9 before the procedures to 0.5 at final follow-up (p<0.0001). No complication was encountered. Conclusion: An ultrasound guided local steroid injections following multiple dry needlings would be one of the useful treatment modality for the acute calcific tendinitis of shoulder.

  • PDF

Clinical Outcomes of Ultrasound-Guided Subacromial Bursal Steroid Injection in Shoulder Impingement Syndrome (견관절 충돌 증후군에서 초음파하 견봉하 점액낭내 스테로이드 국소 주사의 임상적 결과)

  • Kim, Jung-Man;Nam, Ho-Jin;Ra, Ki-Hang;Park, Bum-Suk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.68-73
    • /
    • 2009
  • Purpose: We retrospectively studied the outcomes of the shoulder impingement syndrome for the treatment of the ultrasound-guided subacromial bursal steroid injection. Materials and Methods: Sixty-six shoulders of sixty-two patients with shoulder impingement syndrome treated from March, 2006 to April, 2009 were involved in this study. All cases underwent standardized, nonoperative treatment protocol consisting of 5~12 MHz high resolution ultrasound-guided local steroid injection into the subacromial bursa in modified Crass position. The shoulder range of motion, VAS score and impingement signs were evaluated during the initial and 1year visits. After injection, shoulder elevation exercise was encouraged. Statistical analysis with ANOVA model and Tukey's post-hoc test with the significance level at 5% were performed using SAS program. Results: All cases showed improved range of motion without limitation of shoulder function at immediate post-injection, 6-week, 3-month and 1year visits. The average VAS score at one year follow-up decreased to 2.85 from 6.47 before injection. In all cases the impingement signs became negative immediate after injection. However, 6 cases showed positive impingement signs after 6-week, which became negative after reinjection. The range of motion and VAS score were improved at one-year follow-up compared to initial visit (p<0.0001). No complication was noted at all follow-up period. Conclusion: Ultrasound-guided subacromial steroid injection alleviated the need of surgery, because it was successful in all our cases to improve pain and function of the shoulders until one year follow-up period.

  • PDF

Relevance of Vitamin D and Dyslipidemia Among Korean Adults - Using Data from the Sixth Korea National Health and Nutrition Examination Survey, 2013~2014 (한국 성인의 비타민 D 수준과 이상지질혈증과의 관련성 - 제 6기(2013년, 2014년) 국민건강영양조사 자료를 이용하여)

  • kim, han-soo;Han, Yeo-Jung;Kim, Byung-Cheol;Ryu, So-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.647-656
    • /
    • 2017
  • Purpose: This study investigated the relationship between vitamin D level and dyslipidemia in Korean adults aged 19 years and older. The data for analysis were obtained from the sixth Korea National Health Nutrition Examination Survey 2013 and 2014. Result: This study showed that 74.4% of the specified adult population had vitamin D deficiency. Moreover, the prevalence of dyslipidemia was found to be 39.6% in the same population. Dyslipidemia differed significantly according to gender (p<0.001), age (p<0.001), smoking status (p<0.001), subjective health status (p<0.001), BMI (p<0.001), blood pressure (p<0.001), FBS (p<0.001), physical activity (p<0.001), and vitamin D level (p<0.001). When vitamin D deficiency was less than 20.0 ng/mL, there was a significant risk of dyslipidemia with an odds ratio of 1.29 (95% Cl, 1.11-1.51). The relationship between vitamin D level and a diagnosis index of dyslipidemia with controlled status of physical activity was statistically significant; in Korean adults, the odds ratio for total cholesterol was 1.41 (95% CI, 1.04-1.81) and for triglyceride was 1.36 (95% CI, 1.11-1.66). Conclusion: Our results showed the relationship between vitamin D level and dyslipidemia was significant in Korean adults, and total cholesterol and triglycerides, which are indicators of dyslipidemia, was significant. Future studies, such as a more systematic cohort study investigating the relationship between vitamin D level and dyslipidemia may be helpful in confirming the causal relationship between vitamin D and dyslipidemia.

Simultaneous Determination of 8 Preservatives (6 Parabens, 2-Phenoxyethanol, and Chlorphenesin) in Cosmetics by $UPLC^{TM}$ ($UPLC^{TM}$를 이용한 화장품 중 보존제 8종(파라벤 6종, 페녹시에탄올, 클로페네신)의 동시분석)

  • Park, Jeong-Eun;Lee, So-Mi;Jeong, Hye-Jin;Chang, Ih-Seop
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.33 no.4
    • /
    • pp.263-267
    • /
    • 2007
  • Parabens are used in nearly all types of cosmetics and toiletries because they are formulated well and have broad spectrum of activity, interness, low costs and excellent chemical stability in relation to pH. 2-phenoxyethanol and chlorphenesin are common preservatives which are usually used in combination with parabens in cosmetics. Toxicity of parabens is generally low but application of parabens to damaged or broken skin has resulted in sensitization. Moreover, the possibility of their estrogenic potential, anesthetic effects and reproductive toxicity has been reported. Consequently there are some regulations in use of parabens. And the maximum permitted concentrations of chlorphenesin and 2-phenoxyethanol in cosmetic products are authorized by the same reasons. So it is important to control and estimate the amount of parabens in products. In this article, we proposed a valid method for the simultaneous determination of 8 preservatives including parabens in a short time using ultra performance liquid $chromatography^{TM}\;(UPLC^{TM})$. Separation of eight components was achieved in less than 10 min and resolutions were reasonable (USP resolution ${\geqq}\;2$). And limit of detection and quantification were evaluated. The method was suitably validated for specificity, linearity, precision (repeatability, intermediate precision) and accuracy for assay (recovery) based on International conference on harmonisation (ICH) guideline. The method was applicable to analysis of preservatives in cosmetic products.

Makeup Cleansing Formulation with Lamellar Liquid Crystal Phase (라멜라 액정상 메이크업 클렌징 제형)

  • Yeo, Hye Lim;Lee, Ji Hyun;Kim, Su Ji;Noh, Minjoo;Jang, Ji Hui;Kim, Youn Joon;Yoon, Moung Seok;Yoo, Kweon Jong;Lee, Jun Bae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.43 no.1
    • /
    • pp.79-86
    • /
    • 2017
  • This study is related to a lamellar liquid crystal make-up cleansing formulation with a hologram-like unique appearance between two polarizing plates. Make-up cleansing formulations with a lamellar liquid crystal phase have been extensively studied for a long time, but there have been limitations in practical commercialization because of increasing turbidity and viscosity. In this study, to solve this problem, alkyl chains of surfactants were modified to increase the fluidity of the liquid crystal phase, and electrostatic repulsion force was increased by introducing anionic surfactant. The lamellar liquid crystal make-up cleansing formulation which introduced anionic surfactants can easily inhibit crystallization through electrostatic repulsion force, thereby showing excellent stability overtime, maintaining transparent appearance and viscosity. In addition, we have newly introduced an in vitro cleansing evaluation method using fluorescent material and in vivo imaging system (IVIS) for objective and quantitative cleansing ability evaluation. The excellent cleansing ability of lamellar liquid crystal cleansing formulation has been confirmed by newly developed evaluation method. On the other hand, when lamellar liquid crystal make-up cleansing formulation was placed between orthogonally arranged two polarizing plates, a specific pattern like a hologram can be observed. This phenomenon is presumably interpreted as the interference between the visible light passing through the liquid crystal formulation and the lamellar structure. The lamellar structure of cleansing formulation was confirmed by SAXS analysis, exhibiting Bragg spacing ratio of 1 : 2. The lamellar liquid crystal make-up cleansing formulation prepared in this study would be useful for future application in make-up cleansing due to its excellent stability, cleansing ability, and unique hologram-like pattern placed between two polarizing plates.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010 (설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo-Young;Choi, Jong-Min;Kim, Su-Min;Kwon, Young-Chul;Baik, Yong-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

Formation of the $CoSi_{2}$ using Co/Zr Bilayer on the Amorphous and the Single Crystalline Si Substrates (단결정과 비정질 Si 기판에서 Co/Zr 이중층을 이용한 $CoSi_{2}$ 형성)

  • Kim, Dong-Wook;Jeon, Hyeong-Tag
    • Korean Journal of Materials Research
    • /
    • v.8 no.7
    • /
    • pp.621-627
    • /
    • 1998
  • The formation of Co-silicide between Co/Zr bilayer on the amorphous and crystalline Si substrates has been investigated. The films of Zr(50$\AA$) and Co(l50$\AA$) were deposited with e-beam evaporation system and were heattreated with the rapid thermal annealing system at the temperatures between 50$0^{\circ}C$ and 80$0^{\circ}C$ with 10$0^{\circ}C$ increments for 30 seconds. The phase identification of Co-silicide was carried out by XRD and the chemical analysis was examined by AES and RBS. The interface morphologies of Co/Zr bilayer films were investigated by cross sectional TEM and HRTEM. $CoSi_2$ was formed epitaxially on the crystalline Si substrate above $700^{\circ}C$ while polycrystalline $CoSi_2$ was grown on the amorphous Si substrate. The formation temperature of Co-silicide on the amorphous Si substrate was about 100 C lower than that on the crystalline Si. The COzSi phase was not identified on the both Si substrates. The formation temperature of first phase of Co-silicide on ColZr bilayer was higher than that on Co mono layer. CoSizlayer formed on the amorphous Si substrate exhibits better uniformity compared to the CoSiz formed on the crystalline substrate. The sheet resistance of CoSiz layer on crystalline Si was lower than that on the amorphous Si at high temperatures.tures.

  • PDF

Prediction of Heat-treatment Time of Black Pine Log Damaged by Pine Wilt Disease (소나무재선충병 피해를 받은 곰솔 원목의 열처리 소요시간 예측)

  • Han, Yeonjung;Seo, Yeon-Ok;Jung, Sung-Cheol;Eom, Chang-Deuk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.370-380
    • /
    • 2016
  • The black pine logs damaged by pine wilt disease in Jeju-do were heat-treated to extend the utilization of domestic trees damaged by pine wilt disease. The heat-treatment of wood requires wood to be heated to $56^{\circ}C$ for 30 min at the core. The average moisture content and top-diameter of the black pine logs were ranged from 46% to 141% and from 180 mm to 500 mm, respectively. And the basic specific gravity and oven-dry specific gravity of the black pine logs were 0.47 and 0.52, respectively. The time required for heat-treatment at $105^{\circ}C$ temperature was ranged from 7.7 h to 44.2 h, depending on moisture content and top-diameter. The temperature distribution was used to predict the time required for heat-treatment of black pine log with various moisture contents and top-diameters using finite difference method. The thermal properties of wood including the thermal conductivity and specific heat in accordance with moisture content were calculated. Heat transfer coefficient for mixed convection in form of adding natural convection and forced convection was used for heat transfer analysis. The error between the measured and predicted values ranged from 3% to 45%. The predicted times required for heat-treatment of black pine log with 50% moisture content and 200 mm, 300 mm, and 400 mm top-diameter were 10.9 h, 18.3 h, and 27.0 h, respectively. If the initial moisture content of black pine log is 75%, heat treatment times of 13.6 h, 22.5 h, and 32.8 h were predicted in accordance with top-diameter. And if the initial moisture content of black pine log is 100%, heat treatment times of 16.2 h, 26.5 h, and 38.2 h were predicted in accordance with top-diameter. When the physical properties of logs damaged by pine wilt disease are presented, these results can be applicable to the heat-treatment of red pine and Korean pine logs as well.

Analysis of Risk Factors and Effect of Vancomycin for Sternal Infection after Coronary Artery Bypass Graft (관상동맥우회술 후 흉골감염의 위험인자분석 및 반코마이신의 효과)

  • Baek, Jong-Hyun;Jung, Tae-Eun;Lee, Dong-Hyup;Lee, Jang-Hoon;Kim, Jung-Hee
    • Journal of Chest Surgery
    • /
    • v.43 no.4
    • /
    • pp.381-386
    • /
    • 2010
  • Background: Sternal wound infection (SWI) is an important complication after cardiac surgery. The aim of this study was to investigate the predictors affecting sternal wound infection and preventive factors including short term Vancomycin therapy in patients who underwent coronary artery bypass grafting (CABG). Material and Method: A retrospective study was done using data collected from January 2001 through December 2007. This included 219 patients who had isolated CABG. The definition of SWI was documentation from a microbiological study and a requirement for simple closure or other surgical revision. Result: The overall incidence of SWI was 7.8% (n=17). The causative organisms were methicillin resistant Staphylococcus aureus (MRSA, n=13), methicillin resistant Staphylococcus epidermidis (n=2), Pseudomonas aeruginosa (n=1), and Candida albicans (n=1). Ten cases had deep sternal wound infection with mediastinitis; 7 cases had a superficial wound infection. Infection-related mortality was low (1/17; 6%). Diabetes mellitus (p=0.006) and smoking history (p=0.020) were factors that predicted high risk. Short term use of vancomycin decreased the incidence of MRSA-associated SWI (p=0.009). For treatment, curettage and rewiring or flap were needed in most cases (88%, n=14). Conclusion: Patients who had diabetes mellitus and a smoking history need careful management. Short term use of vancomycin is effective for prevention of SWI with MRSA.