• Title/Summary/Keyword: Users' assessment

Search Result 553, Processing Time 0.029 seconds

Multimedia Elements of the Game for the Quality Assessment (게임의 멀티미디어 요소에 대한 품질 평가)

  • Yoon, Seon-Jeong;Ryu, Mi-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.252-255
    • /
    • 2012
  • Multimedia element of the game graphics and sound, etc. 'commitment' that plays an important role in gameplay. Therefore, the quality of the game is closely related to the quality of multimedia elements that can be. In this study, various competitions in the field of content screening criteria based on previous studies and multimedia elements of the game area, and domain-specific details about the quality of sub-elements were extracted. Assessment areas and sub-elements extracted to verify the need for the game will be carried out surveys among the users. The findings in the next game production shall be deemed to be an important reference material.

  • PDF

BEPAT: A platform for building energy assessment in energy smart homes and design optimization

  • Kamel, Ehsan;Memari, Ali M.
    • Advances in Energy Research
    • /
    • v.5 no.4
    • /
    • pp.321-339
    • /
    • 2017
  • Energy simulation tools can provide information on the amount of heat transfer through building envelope components, which are considered the main sources of heat loss in buildings. Therefore, it is important to improve the quality of outputs from energy simulation tools and also the process of obtaining them. In this paper, a new Building Energy Performance Assessment Tool (BEPAT) is introduced, which provides users with granular data related to heat transfer through every single wall, window, door, roof, and floor in a building and automatically saves all the related data in text files. This information can be used to identify the envelope components for thermal improvement through energy retrofit or during the design phase. The generated data can also be adopted in the design of energy smart homes, building design tools, and energy retrofit tools as a supplementary dataset. BEPAT is developed by modifying EnergyPlus source code as the energy simulation engine using C++, which only requires Input Data File (IDF) and weather file to perform the energy simulation and automatically provide detailed output. To validate the BEPAT results, a computer model is developed in Revit for use in BEPAT. Validating BEPAT's output with EnergyPlus "advanced output" shows a difference of less than 2% and thus establishing the capability of this tool to facilitate the provision of detailed output on the quantity of heat transfer through walls, fenestrations, roofs, and floors.

A Systematic Approach to Quality Measurement of Official Statistics) (국가통계 품질측정을 위한 체계적 접근 - 표본조사의 품질평가지표 개발을 중심으로)

  • 이동명;김설희
    • Proceedings of the Korean Association for Survey Research Conference
    • /
    • 2002.11a
    • /
    • pp.111-127
    • /
    • 2002
  • As the utilization of official statistics has been recently increased, the necessity of objective quality assessment also has been increased. Since mean square error(MSE) and response rate, which have been considered as representative quality indicators in the past, may have the limits of use, it has been demanded to develop new quality indicators which are able to reflect the various requirements of users. In this paper, regarding sample surveys conducted by governmental agencies, the flow of procedures in statistics production is analyzed using input-output of each procedure. As the result, how to identify and develop quality indicators for each procedure is discussed, with some instances of indicators. Finally, the quality index using the results of quality assessment would be calculated based on a weighting method by the size of deviation of statistical measures.

  • PDF

Development and Application of Evacuation and Fatalities Assessment Program (대피 및 인명피해 평가 프로그램 개발 및 적용사례)

  • Yoon, Sung-Wook;Rie, Dong-Ho
    • Tunnel and Underground Space
    • /
    • v.21 no.4
    • /
    • pp.274-280
    • /
    • 2011
  • Evacuation and Fatalities Simulation is one of the core technologies for performance based design. Recently, developed programs in foreign countries have limitations such as simple fatality calculation and coarse visual interface. This study developed an advanced evaluation program for evacuation and fatalities to overcome limitations of existing programs and improve various applications, i.e., an evacuation algorithm using elevators as well as evacuation stairs. In addition, the evaluation program can let users make a decision of fatalities from fire by coupling with FDS (Fire Dynamics Simulator) from NIST and realizes three-dimensional virtual space using a graphic module.

Web based and Muti-Users Channelled a Probabilistic Reliability Assessment Simulation System considering Renewable Energy Generators (웹기반 및 다사용자 동시 접속 가능한 신재생에너지전원을 포함한 확률론적 신뢰도 및 발전모의 시스템의 구축)

  • Park, Jeong-Je;Wu, Liang;Choi, Jae-Seok;Ma, Dae-Young;Cha, Jun-Min;Song, Tae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.581_582
    • /
    • 2009
  • 최근 국내외적으로 스마트그리드, 마이크로그리드와 같은 곧 다가올 미래형전력계통망에 대한 기반기술연구가 매우 중요하다. 이는 전력IT기술과도 깊은 관련성이 있는 것으로써 그 성공여부는 전력IT기술과 협조를 맺으면서 여하히 기술적으로 이를 실현화(Implementation)하는냐에 달려있다고 하겠다. 본 연구에서는 최근 국내외적으로 급부상하고 있는 스마트그리드 마이크로그리드와 같은 곧 다가올 미래형전력계통망에 대비하고 나아가 $CO_2$ 감축의무와 맞물려 있는 분산형 신재생에너지발전원의 계통병입이 전력에너지의 적정공급신뢰도에 미치는 영향을 정량적으로 분석할 수 있는 웹기반 확률론적인 신뢰도 및 발전비용모의를 인터넷의 사용이 가능한 곳이면 어느 장소 및 시간대(Any where & any time)에서나 실시할 수 있는 시스템인 가칭, WPRASS V1.0(Web based Probabilistic Reliability Assessment Simulation System V1.0)을 성공적으로 구축하였다.

  • PDF

A Study on the adequacy of Hospital Architecture Deign-Build and Improvement of Assessment Criteria - Focus on the case of Architectural Planning Design Change - (병원건축 일괄입찰방식의 적합성과 평가기준 개선방안에 관한 연구 - 건축계획의 설계변경사례를 중심으로 -)

  • Hong, Seung-Min;Yang, Nae-Won
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.2
    • /
    • pp.215-222
    • /
    • 2012
  • Design-build is expanding gradually in large construction projects over 10billion won, and continue to work in health care facilities is increasing in this way. This constructional method in health care facilities, despite the many advantages, many problems caused by design changes are being raised. Raises the question of design changes on the side of construction contract, such as approval systems have been studied in the field of construction. The purpose of this study design in aspects of architectural planning on changing the grasp of the issues outlined in the ITB and bid evaluation criteria through consideration of the basic plan for improvement guidelines and evaluation criteria is presented. In conclusion, Design build, according to the presence of existing users are more likely to lead to design changes. Thus, hospital architecture, depending on how it is considered that constructional methods. And evaluation items of ITB(Invitation To Bidder) for a large part of the change in the variables evaluated in the hospital building is not suitable for the design build. Instead, the overall shape of the building and department, unit type and size, vertical and horizontal parts of the circulation system in the shape of the building that does not change in structure and etc should be considered for evaluation.

  • PDF

A Study on the Methods of Fault Analysis for Security Improvement of National Education Information System(NEIS) (교육행정정보시스템의 보안성 개선을 위한 결함 분석 방법에 관한 연구)

  • Lyu, Min-Wan;Park, Man-Gon
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.12
    • /
    • pp.1970-1979
    • /
    • 2017
  • Computerization of educational administration following educational informatization of government has been steadily improved for the purpose of teachers' offload and job efficiency, finally resulting that NEIS(National Education Information System) has been completed. The NEIS consists of Nationwide service of NEIS, Business portal system of NEIS, Authentication management system and so on. Students, parents and civil petitioners handle civil affairs through Nationwide service of NEIS and teachers and persons of task conduct theirs business by accessing the Business portal system of NEIS. At this time, users have to obtain their certification from Authentication management system. Previous Studies were mainly focused on the evaluation about its performance according to the introduction of NEIS. But from now on there is a growing interest in security assessment and an efficient method for security improvement to check if NEIS works properly. Therefore, in this thesis, we'll propose an analytic framework in which security assessment is carried out after comprehending the fault structures through performing Fault Fishbone Analysis based on the Fault Tree Analysis. As a result of the system applied, the system had the highest rate of improvement to 47.7 percent.

An Experimental Model for 'Information Needs Assessment': From the User's Perspective (수요자 중심의 '정보요구' 분석을 위한 실험적 모형에 관한 연구)

  • Lee Jae-Whoan;Koo Joung-Hwa
    • Journal of Korean Library and Information Science Society
    • /
    • v.30 no.2
    • /
    • pp.93-121
    • /
    • 1999
  • The purpose of this study is to develop an experimental model for information needs assessment, which could be utilized to investigate the 'real' information needs of the user(or group). The focus was on the perspectives of users rather than those of system managers. In details, this study identifies the conceptual definition of the keyword 'information need', analyzes the limitation and problems the previously conducted needs assessments in this area, and finally, develops an experimental model based on the cognitive and affective variables which might influence both production and strength of information needs in the user(or group}. The model emphasizes four influencing variable, namely, individual, work-related, organizational(or institutional), and socio-cultural variables. Also discussed is the relationships among these variables.

  • PDF

Comparative Efficiency Evaluation of Air Cleaners for Improving Indoor Air Quality (실내용 공기청정기 유형별 실내환경개선 성능에 대한 비교평가)

  • Na, Kyung-Ho;Son, Jin-Seok;Sung, Kijune;Jang, Young-Kee
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.3
    • /
    • pp.109-115
    • /
    • 2005
  • This study was conducted to evaluate the efficiency of indoor air cleaners and to inform how to select them correctly to the users. The efficiencies of removing suspended bacteria per hour were $64.3{\pm}13.1%$ for filter, wet, and complex type, respectively, which showed the complex type was the most efficient. The removal efficiencies of formaldehyde (HCHO) after two hours operation of air cleaners showed 88.3% and 81.1% for filter and wet type, respectively. The efficiency of complex type, with removal rate of 55.5~58.4%, was decreased after 30 minutes operation. Therefore, it is recommended to perform over 60 minutes when doing air cleaner certification test for HCHO removal efficiency. Generally, air cleaners having low wind volume showed higher efficiency. All tested air cleaners had no potential for removing of volatile organic compounds (VOCs), which is toxic substances, and it is desirable to develop a device which can control these substances. The results also confirmed that there was no ozone production from all tested air cleaners. And it is recommended to ventilate for 20 minutes every four hours to maintain 50% ventilation status.

Erogonomic assessment of "Noraebang" noise and potential hearing-loss and hearing protection strategies (노래방 소음 및 난청가능성의 인간공학적 평가와 청각보호방안)

  • 박민용
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.79-90
    • /
    • 1996
  • A research project was conducted to assess the levels of noise exposed to "Noraebang" users and potential hazards to noise-induced hearing loss due to commercial Noraebang noise. A two-way, mixed-factors factorial design was employed for the experiment using independent variables of "noise source" (no- singer, 1-singer, and 2-singer conditions) and "music type" (Trot, Ballad, and Rock music) with 18 normal hearing subjects. Each singer group sang 5 popular songs of each music type in each signing condition, whereas background music was just played for the no-singer condition. For each music played/sung, equivalent continuous sound pressure levels and maximum sound pressure levels were measured for data analysis purposes. Pure-tone audiometry was applied for measuring subjects' hearing threshold levels before and after exposure to Noraebgang noise. The statistical analyses indicate that average continuous noise levels due to Noraebang leisure environment were very serious, especially when two people were singing (higher than 95 dBA). Furthermore, maximum noise levels often exceeded the OSHA's non-premissible 115 dBA level. Worse yet, hearing loss assessment implies that Noraebang facilities may pose a serious threat to noise-induced hearing loss, based on 6-8 dB loss at 125 Hz and 8 dB loss at 4000 Hz after about 1-hour Noraebang noise exposure.

  • PDF