• Title/Summary/Keyword: Useful energy

Search Result 2,416, Processing Time 0.029 seconds

Importance Assessment of Multiple Microgrids Network Based on Modified PageRank Algorithm

  • Yeonwoo LEE
    • Korean Journal of Artificial Intelligence
    • /
    • v.11 no.2
    • /
    • pp.1-6
    • /
    • 2023
  • This paper presents a comprehensive scheme for assessing the importance of multiple microgrids (MGs) network that includes distributed energy resources (DERs), renewable energy systems (RESs), and energy storage system (ESS) facilities. Due to the uncertainty of severe weather, large-scale cascading failures are inevitable in energy networks. making the assessment of the structural vulnerability of the energy network an attractive research theme. This attention has led to the identification of the importance of measuring energy nodes. In multiple MG networks, the energy nodes are regarded as one MG. This paper presents a modified PageRank algorithm to assess the importance of MGs that include multiple DERs and ESS. With the importance rank order list of the multiple MG networks, the core MG (or node) of power production and consumption can be identified. Identifying such an MG is useful in preventing cascading failures by distributing the concentration on the core node, while increasing the effective link connection of the energy flow and energy trade. This scheme can be applied to identify the most profitable MG in the energy trade market so that the deployment operation of the MG connection can be decided to increase the effectiveness of energy usages. By identifying the important MG nodes in the network, it can help improve the resilience and robustness of the power grid system against large-scale cascading failures and other unexpected events. The proposed algorithm can point out which MG node is important in the MGs power grid network and thus, it could prevent the cascading failure by distributing the important MG node's role to other MG nodes.

A bond graph approach to energy efficiency analysis of a self-powered wireless pressure sensor

  • Cui, Yong;Gao, Robert X.;Yang, Dengfeng;Kazmer, David O.
    • Smart Structures and Systems
    • /
    • v.3 no.1
    • /
    • pp.1-22
    • /
    • 2007
  • The energy efficiency of a self-powered wireless sensing system for pressure monitoring in injection molding is analyzed using Bond graph models. The sensing system, located within the mold cavity, consists of an energy converter, an energy modulator, and a ultrasonic signal transmitter. Pressure variation in the mold cavity is extracted by the energy converter and transmitted through the mold steel to a signal receiver located outside of the mold, in the form of ultrasound pulse trains. Through Bond graph models, the energy efficiency of the sensing system is characterized as a function of the configuration of a piezoceramic stack within the energy converter, the pulsing cycle of the energy modulator, and the thicknesses of the various layers that make up the ultrasonic signal transmitter. The obtained energy models are subsequently utilized to identify the minimum level of signal intensity required to ensure successful detection of the ultrasound pulse trains by the signal receiver. The Bond graph models established have shown to be useful in optimizing the design of the various constituent components within the sensing system to achieve high energy conversion efficiency under a compact size, which are critical to successful embedment within the mold structure.

Direct Energy Method of Power System Stability Analysis and its Application by using Energy Conservation Law (에너지보존법칙을 이용한 전력계통 안정도 직접 해석법에서의 응용)

  • Lee, Yong-Hoon;Cho, Byoung-Hoon;Ryu, Heon-Su;Moon, Young-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1207-1214
    • /
    • 1999
  • Many papers have recently been presented to develop energy functions for power systems. However, earlier studies adopted case-by-case approaches, which failed to give a general approach to deal with various kinds of generator models. In this paper, two useful theorems are developed regarding the integral relationships of the generator power versus its phasor current and voltage. By using the proposed theorems, an exact energy conservation law can be derived from the complex integral. The proposed energy conservation law, which is free of the generator model, can be utilized to develop energy functions for various kinds of generator models including the speed governors and exciters. An illustrative example is given for a multimachine system with the Eq' model of generator. This thesis also shows a possibility of more accurate and fast stability analysis by using the proposed Energy Conservation Law.

  • PDF

JASMIN: Shielding Studies on High Energy Neutron Produced By 120 GeV Protons

  • Lee, Hee-Seock;Sanami, Toshiya;Iwamoto, Yosuke;Kajimoto, Tsuyoshi;Shigyo, Nobuhiro;Saito, Kiwamu;Hagiwara, Masayuki;Yashima, Hiroshi;Kasugai, Yoshimi;Ramberg, Erik;Coleman, Richard;;Meyhoefer, Aria;Mokhov, Nikolai V.;Leveling, Anthony F.;Boehnlein, David J.;Vaziri, Kamran;Sakamoto, Yukio;Nakashima, Hiroshi
    • 대한방사선방어학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.94-95
    • /
    • 2010
  • The accuracy of typical dosimeters used around high energy accelerator were proved by dose rate measurements. The experimental neutron spectrum were useful for improving high energy Monte Carlo codes by validating the implemented models. In series of this joint research the experimental data will be upgrade successively. This research program is opened to experts and students in Korea, too.

  • PDF

Energy Conservation Law and its application for Direct Energy method of Power System Stability (에너지 보존법칙과 전력계통 안정도 직접 해석법에서의 응용)

  • Moon, Young-Hyun;Lee, Yong-Hoon;Cho, Byoung-Hoon;Ryu, Heon-Su;Choi, Byoung-Kon
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.263-268
    • /
    • 1998
  • Many papers have recently been presented to develop energy functions for power systems. However, earlier studies adopted case-by-case approaches, which failed to give a general approach to deal with various kinds of generator models. In this paper, two useful theorems are developed regarding the integral relationships of the generator power versus its phasor current and voltage. By using the proposed theorems, an exact energy conservation law can be derived from the complex integral. The proposed energy conservation law, which is free of the generator model, can be utilized to develop energy functions for various kinds of generator models including the speed governors, and exciters. An illustrative example is given for a multimachine system with the Eq' model of generator. This thesis also shows a possibility of more accurate and fast stability analysis by using the proposed Energy Conservation Law.

  • PDF

A Study on the Policies Evaluation Framework for Environmentally Friendly City (환경친화적 도시 조성을 위한 정책평가체계에 관한 연구 - 저부하형 도시 조성을 중심으로 -)

  • Yoon, So Won
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.4
    • /
    • pp.8-16
    • /
    • 2003
  • In terms of climate change communities have only during the 1990s begun to recognize that all greenhouse gas(GHG) emissions are directly or indirectly generated locally, through acts of agency, production or consumption. This has provided a boost to the role of local places in the debate since GHGs can be allocated and made understood locally and hence form the basis for specific policies, programs, plans and projects. The objectives of this study are to define a framework for making Environmentally Friendly City through enhancing integrated energy-urban policies and present framework to do comprehensive evaluation on energy related policies response and also explore the interrelation between energy related activities in each sector and policy and applies to Seoul mega city in Korea. Despite the growing recognition of the seriousness of urban environmental problems and their contribution to global environmental and social concerns, most analysts continue to study cities in parts rather than as a whole; we study sectoral sub-systems such as transport, air pollution or energy. While specialization is useful for detailed thinking, we also need to see each issue in the context of how each city works environmentally, economically, socially and politically. We therefore need integrative approaches to study of cities and need to understand how they function as systems. These framework presented in this study allows an organized and systematic analysis. These research results can provide useful, credible and timely input into the urban planning process. This study will be a helpful exercise to draw some policy implications of other cities in Korea and also East Asia that are in a similar stage with the these cities and developing plans on how to address them.

Large Eddy Simulation for the Prediction of Unsteady Dispersion Behavior of Hydrogen Fluoride (불산의 비정상 확산거동 예측을 위한 대와동모사)

  • Ko, M.W.;Oh, Chang Bo;Han, Y.S.;Choi, B.I.;Do, K.H.;Kim, M.B.;Kim, T.H.
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.14-20
    • /
    • 2015
  • A Large Eddy Simulation(LES) was performed for the prediction of unsteady dispersion behavior of hydrogen fluoride (HF). The HF leakage accident occurred at the Gumi fourth industrial complex was numerically investigated using the Fire Dynamics Simulator (FDS) based on the LES. The accident area was modeled three-dimensionally and time-varying boundary conditions for wind were adopted in the simulation for considering the realistic accident conditions. The Message Passing Interface (MPI) parallel computation technique was used to reduce the computational time. As a result, it was found that the present LES simulation could predict the unsteady dispersion features of HF near the accident area effectively. The dispersion behaviors of the leaked HF was much affected by the unsteady wind direction. The LES could predict the time variation of the HF concentration reasonably and give an useful information for the risk analysis while the prediction with the time-averaging concept of HF concentration had a limitation for the amount of HF concentration at specific location point. It was identified that the LES is very useful to predict the dispersion characteristics of hazardous chemicals.

Study on Optimization of Operating Conditions for High Temperature PEM Fuel Cells Using Design of Experiments (실험계획법을 이용한 고온 고분자 전해질 막 연료전지의 운전조건 최적화 연구)

  • Kim, Jintae;Kim, Minjin;Sohn, Youngjun
    • Journal of Hydrogen and New Energy
    • /
    • v.24 no.1
    • /
    • pp.50-60
    • /
    • 2013
  • High temperature proton exchange membrane fuel cells (PEMFCs) using phosphoric acid (PA) doped polybenzimidazole (PBI) membranes have been concentrated as one of solutions to the limits with traditional low temperature PEMFCs. However, the amount of reported experimental data is not enough to catch the operational characteristics correlated with cell performance and durability. In this study, design of experiments (DOE) based operational optimization method for high temperature PEMFCs has been proposed. Response surface method (RSM) is very useful to effectively analyze target system's characteristics and to optimize operating conditions for a short time. Thus RSM using central composite design (CCD) as one of methodologies for design of experiments (DOE) was adopted. For this work, the statistic models which predict the performance and degradation rate with respect to the operating conditions have been developed. The developed performance and degradation models exhibit a good agreement with experimental data. Compared to the existing arbitrary operation, the expected cell lifetime and average cell performance during whole operation could be improved by optimizing operating conditions. Furthermore, the proposed optimization method could find different new optimal solutions for operating conditions if the target lifetime of the fuel cell system is changed. It is expected that the proposed method is very useful to find optimal operating conditions and enhance performance and durability for many other types of fuel cell systems.

Energy and Entransy Characteristic Analysis of Heat Exchangers Depending on Heat Exchanger Type (열교환기 형식에 따른 열교환기의 에너지 및 엔트랜시 성능 특성 해석)

  • KIM, KYOUNG HOON;JUNG, YOUNG GUAN;HAN, CHUL HO
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.1
    • /
    • pp.112-121
    • /
    • 2020
  • In this work energy and entransy characteristics of heat exchangers are analyzed for 12 different flow arrangements of heat exchangers. The dimensionless parameters are number of entransy dissipation (Ng), number of entransy dissipation-based thermal resistance (Nr), and entransy dissipation-based effectiveness of heat-exchanger (εg). The dimensionless parameters are expressed analytically in terms of the effectiveness of heat exchanger (ε), heat capacity ratio (c), and number of transfer unit (N) for optimal performance of heat exchangers. Results showed that the dimensionless parameters based on the entransy dissipation can be useful concepts for optimal design of heat exchangers.

A New Scheme for Maximizing Network Lifetime in Wireless Sensor Networks (무선 센서네트워크에서 네트워크수명 극대화 방안)

  • Kim, Jeong Sahm
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.2
    • /
    • pp.47-59
    • /
    • 2014
  • In this paper, I propose a new energy efficient clustering scheme to prolong the network lifetime by reducing energy consumption at the sensor node. It is possible that a node determines whether to participate in clustering with certain probability based on local density. This scheme is useful under the environment that sensor nodes are deployed unevenly within the sensing area. By adjusting the probability of participating in clustering dynamically with local density of nodes, the energy consumption of the network is reduced. So, the lifetime of the network is extended. In the region where nodes are densely deployed, it is possible to reduce the energy consumption of the network by limiting the number of node which is participated in clustering with probability which can be adjusted dynamically based on local density of the node. Through computer simulation, it is verified that the proposed scheme is more energy efficient than LEACH protocol under the environment where node are densely located in a specific area.