• 제목/요약/키워드: Use of Power

검색결과 7,968건 처리시간 0.042초

웹 기술을 이용한 전기품질 감시시스템 연구 (A Study of Power Quality Monitoring System Using Web Technology)

  • 이강석;임성일;이승재;이동욱;박동호;김정한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.148-150
    • /
    • 2003
  • A meaning of power quality has changed, which affects on an environmental change of existing electricity supply markets. Today, it should take both consumers and suppliers into consideration to develop information and communication technology and to increase the use of power and electronic equipments. As a result, it is necessary to develop a system to monitor power quality and to display data. In this paper, a system, as a power quality monitoring equipment, which can use protective replays with progress of microprocessor technology and provide information in the intranet/internet circumstances using web-based architecture is described.

  • PDF

Parallel-Connected Magnetic Energy Recovery Switch Used as a Continuous Reactive Power Controller

  • Wei, Yewen;Fang, Bo;Kang, Longyun;Huang, Zhizhen;liu, Teguo
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1494-1503
    • /
    • 2016
  • Power quality promotion has received increasing attention because of the wide use of semiconductor devices in recent decades. Reactive power regulation is crucial to ensuring the stable operation of power systems. In this study, a continuous reactive power controller, which is referred to as a parallel-connected magnetic energy recovery switch (MERS), is developed to regulate voltage or power factor in power grids. First, the operating principle is introduced, and a mathematical model is built. Second, a new control method for restraining current harmonics and the peak voltages of capacitors is presented. Using the proposed method, the MERS shows a wide range in terms of reactive power compensation. Finally, the performance of the proposed controller is demonstrated through computer simulations and experiments. Unlike STATCOMs, the proposed controller entails low losses, adopts a small dc capacitor, and offers ease of use.

무효전력 민감도와 부하지속곡선을 활용한 적정 부하역률의 효과적인 산정 기법에 관한 연구 (A Study on a Methodology of Determining an Appropriate Load Power Factor Effectively by the Use of Reactive Power Sensitivity and Load Duration Curve)

  • 이병하;황승호
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1782-1790
    • /
    • 2012
  • In this paper, a methodology to use load duration curve and the reactive power factor sensitivity of generation cost is proposed for analyzing the effects of load power factor effectively. A great deal of cases of power systems are classified into several patterns according to the characteristics using load duration curve, and the overall effects of load power factor are assessed by integrating the analysis results of load power factor in all the patterns. The reactive power sensitivity of generation cost and the integrated costs such as generation cost, investment cost, voltage variation penalty cost and CO2 emission cost are used for determining an appropriate load power factor. A systematic procedure for effective analysis of load power factor is presented. It is shown through the application to the practical power system of KEPCO(Korea Electric Power Corporation)that the effects of load power factor can be analyzed effectively using load duration curve and reactive power factor sensitivity.

역률보상형 전기집진기 전원장치 특성연구 (A study on power source characteristic of a dust collector for power factor compensating)

  • 이동길;홍지태;김호성;손민규;이경준;김종락;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1326-1327
    • /
    • 2008
  • Recently, the air pollution is supposed is to be the most serious environmental problem. Therefore, a small air cleaner is asked to make comfortable indoor environment for the moderns who have frequent indoor activity. In this study, without generating of the second pollution source, dust in the air and harmful microorganisms can be removed by the electric dust collecting technology which has high reliability and efficiency to be able to remove the impurities even though it is just 0.01${\mu}m$. Accordingly, power sources of the dust collector use, it is not inefficiency and offering to dust collector unstable. In order to overcome the point at issue, a this study, for power factor compensating use the PFC circuit, for removing the noise use EMI filter and for generating the hight voltage use the Cockcroft Walton Circuit. And we study power source on characteristic and improvement.

  • PDF

파도에너지를 효율적으로 이용하기위한 파력진동발전기에 대한 연구 (The research of vibration power generation to make effective use of ocean wave energy)

  • 이홍찬;이재호;한기봉
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2011년도 후기공동학술대회 논문집
    • /
    • pp.75-75
    • /
    • 2011
  • This paper has been studied that ocean wave vibration power generator is composed of buoy and vibration generator to make effective use of ocean wave energy. We designed buoy to can occur resonance for dominant frequency with ocean wave. And then we fitted the natural frequency of vibration system with vibration power generator to buoy's natural frequency. And we can show that the amplitude of ocean wave up and down motion is decreased, on the other hand, the displacement of vibration system with vibration power generator is increased. Therefore, ocean wave vibration power generator which is proposed in this paper has merits not only securing its stability from surroundings but also producing more electronic power by using ocean wave energy.

  • PDF

농업 태양광의 발전 특성 분석 (Analysis of Power Generation Characteristics of Agricultural Potovoltaic Systems)

  • 유선호;이의찬;손승우;김봉석
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.151-157
    • /
    • 2022
  • The transition to renewable energy, especially the expansion of photovoltaic (PV) generation, has become a global megatrend that can no longer be reserved. However, since the site for PV is limited, it is necessary to use the land efficiently. As an alternative, the concept of utility scale agricultural PV(UAPV) is a technology that continues farming in the lower part and installs PV in the upper part of farmland to efficiently use the land. Therefore, for UAPV, the growth of crops in the lower part and the optimal operation of PV in the upper part are important. In this, we analyze the characteristics of the upper PV generation system in the UAPV based on the empirical results under various conditions, and propose future research directions of the UAPV.

PWM 정류기를 적용한 직류급전시스템의 조류계산에 대한 연구 (A Study on Power Flow Analysis of DC Traction Power Supply System with PWM Rectifier)

  • 김주락
    • 전기학회논문지
    • /
    • 제65권11호
    • /
    • pp.1919-1924
    • /
    • 2016
  • In general, Diode rectifier has been applied to DC traction power supply system. Diode has some characteristics which is voltage drop in inverse proportion of load because of non-controlled switch, and cannot flow a current in reverse bias. So, voltage drop occurs frequently, and regenerated power cannot use in substation. The PWM rectifier is able to control output voltage constantly to reduce voltage drop and to use regeneration power without additional inverter. This paper proposes analysis algorithm for DC traction power supply system with PWM rectifier.

신재생에너지 예측을 위한 송전선로의 계량 데이터 계산 방법 (Calculation Method of Dedicated Transmission Line's Meteological Data to Forecast Renewable Energy)

  • 백자현;김현진;최순호;박상호
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.55-59
    • /
    • 2022
  • This paper introduce Renewable Energy forecasting technology, which is a part of renewable management system. Then, calculation method of dedicated transmission line's meteorological data to forecast renewable energy is suggested. As the case of dedicated transmission line, there is only power output data combined the number of renewable plants' output that acquired from circuit breakers. So it is need to calculate meteorological data for dedicated transmission line that matched combined power output data. this paper suggests two calculation method. First method is select the plant has the largest capacity, and use it's meteorological data as line meteorological data. Second method is average with weight that given according to plants' capacity. In case study, suggested methods are applied to real data. Then use calculated data to Renewable forecasting and analyze the forecasting results.

에너지 효율적인 무선 센서 네트워크를 위한 통신 이벤트 기반의 전력 관리 방안에 관한 연구 (Communication Event-driven Power Management for Energy Efficient Wireless Sensor Network)

  • 황광일
    • 한국통신학회논문지
    • /
    • 제32권7B호
    • /
    • pp.411-421
    • /
    • 2007
  • 무선 센서 네트워크에서 가장 큰 문제 중의 한 가지는 네트워크를 구성함에 있어 에너지 소모를 최소화하는데 있다. 센서 네트워크에서 에너지를 효율적으로 사용하기 위해서 주로 다음과 같은 두 종류의 방식을 사용한다. 한 가지는 동적 전력 관리를 사용하는 것이며, 다른 한 가지는 에너지 효율적인 프로토콜을 사용하는 것이다. 전자의 경우 전원 관리자는 해당하는 이벤트들에 대해서 CPU와 해당 I/O들의 적절한 전원 상태를 관리할 책임이 있다. 하지만, 주어진 프로토콜의 내부 동작에 대해서는 관여하지 못한다. 그것은 충돌 등으로 인한 통신 상태에서의 지연에 의한 불필요한 에너지를 낭비할 가능성이 크다. 반면에 에너지 효율적인 프로토콜들은 단지 무선 모뎀의 전원 상태만을 고려한다. 본 논문에서 우리는 통신 이벤트 기반의 전력 관리를 통한 무선 센서 노드들의 불필요한 전력 소비를 충분히 줄일 수 있는 에너지 효율적인 전력 관리 방안을 제안하고, 시뮬레이션을 통해 제안하는 전력 관리 방식이 상당한 에너지를 절약 할 수 있음을 보인다.

자기유지 시스템용 효율적인 에너지 사용을 위한 에너지 전력 관리 시스템 연구 (A Study on the Energy-Power Management System for Self-Sustaining Sensor Node System)

  • 황지훈;김종홍;김현웅;노형환;오하령;성영락;박준석
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.349-352
    • /
    • 2009
  • WBAN/USN systems are applied from the various environment. Therefore, it is coming to be important efficient use power and communication method. The present paper materialize Slave node system which get power from light energy. Also, it materialize Wake-up module and self-power-off circuit which use S-R Flip Flop for efficient using power. This system can be efficient using power at Slave node system. Also, it can be possible application of Self sustaining system by performance verification Wake-up module which determine system "on" without power and Self-power-off circuit.

  • PDF