• Title/Summary/Keyword: Use of Power

Search Result 7,953, Processing Time 0.037 seconds

A Study on the Relationship between Nurses Relative Power and Interpersonal Conflicts (간호사의 상대적 권력과 대인갈등)

  • 이명옥
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.1
    • /
    • pp.169-177
    • /
    • 1997
  • This study aims at empirically clarifying the relationship between power and the interpersonal conflict, including nurses' understanding of their relative power, the causes of interpersonal conflicts with the nurses, and strategies to resolve conflicts, in order to understand how nurses' relative power affect their conflicts. For the empirical survey, the population was defined as all the nurses working at a medical organization in Seoul, Korea. 1083 nurses were selected as the sample for the questionnaire survey and statistical analyses. For the sampling, 32 medical organizations were selected by a stratified random method and sub-samples were arbitrarily drawn from each organization to obtain the final sample of 1083 nurses who responded to the questionnaire designed by the reseacher. According to the result of the study, most nurses experience conflict more than once a month, and 70.4% of the respondents answered that interpersonal conflicts were directly or indirectly caused by power relations. which indicates that they perceive power relations as the main cause of interpersonal conflicts. Nurses experienced the most conflicts with interns and residents(29.7%), then patients and their families(24.3%), higher-positioned nurses(12.3%), nurse colleagues(7.7%), lower-positioned nurses(6.5%), and staff doctors(5.1%). If we classify these into three groups. the frequency of the conflicts, from most frequent to least. is in the order of doctors. nurses, and patients. In terms of relative power, nurses perceive that they have greater power than patients and their families, lower-positioned nurses, and nurse colleagues. In contrast, nurses perceive that they have less power than interns and residents, higher-positioned nurses. and staff doctors. Among these groups. nurses perceive that they have the most power over patients and the least over staff doctors. These results indicate that nurses tend to experience more conflicts with members of groups that are stronger than themselves in terms of relative power, Nurses use positive strategies such as the compromise strategy(32.3%) or the collaboration strategy (20.3%) to manage conflicts, more than other strategies. However, they use avoidance or competition strategy more at the earlier stage, compromise strategy more in the mid stage, and collaboration strategy more at the later stage of the interpersonal conflict. In relation to power, nurses use the collaboration strategy or the compromise strategy more when their perceived power is greater than or equal to their counterpart's, and they use the avoidance strategy or the accommodation strategy if their power is less. In terms of source of power, nurses' perceived relative power is greater in the order of referent power. expert power, reward power, legitimate power. and coercive power. where referent power is perceived as having the greatest power and coercive power is least. Most nurses(69.3%) used their power to resolve a conflict. with positive outcomes. Expert power was used most frequently. Overall. this study strongly indicates that the enhancement of power of nurses to have equal power relations with doctors would heighten the success of conflict resolution, since power is the main cause of conflicts. Specifcally. nurses experience most conflicts with doctors against whom they perceive the greatest gap in power. and the choice of a conflict management strategy depend upon their power relations.

  • PDF

Mobile Payment Use in Light of Privacy Protection and Provider's Market Control

  • Mohammad Bakhsh;Hyein Jeong;Lingyu Zhao;One-Ki Daniel Lee
    • Asia pacific journal of information systems
    • /
    • v.31 no.3
    • /
    • pp.257-276
    • /
    • 2021
  • This study investigates the factors that facilitate or hinder people to use mobile payment, especially drawing upon the theoretical perspectives on individual's privacy protection motivation and perceived market condition. Survey data (n = 200) were collected through a web-based platform and used to test a theoretical model. The results show that one's privacy protection power is formed by various individual and technological factors (i.e., perceived data exposure, self-efficacy, and response efficacy), and in turn it determines his/her intention to use mobile payment. Moreover, the relationship between privacy protection power and mobile payment use is conditional on the perceived market control by the service provider - with a perception of the high level of provider's market control, one uses mobile payment regardless of his/her privacy protection power, while under the low level of provider's market control, the decision depends on the degree of privacy protection power. The findings would help our understanding of why some people are more susceptible to mobile payment and others are not.

Educational Simulator for Transmission Network Use of System Charge (송전망 이용요금산정을 위한 교육용 시뮬레이터 개발)

  • Kim, H.H.;Song, H.Y.;Lee, C.J.;Park, J.B.;Shin, J.R.
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.201-203
    • /
    • 2006
  • This paper presents a graphical windows-based software for the education and training of the transmission network use of system charge. The developed simulator consist of the main module(MMI,GUI), the power flow module(PF), the power flow tracing module(PFT) and management of usage cost DB module(UCD). Each module has a separate graphical and interactive interfacing window. To have effective education for transmission network use of system charge, the developed simulator are provided with two power system analysis methods. Input data of power system can use the format of PSS/E input data. Also calculation of power flow tracing are provided with four methods such as "Felix Wu","Modified Felix Wu", "DCLF ICRP" and "Reverse MW mile". Results of calculation for usage cost are shown on the window through the table or chart. Therefore user can confirm the detailed differences of results from each calculation method.

  • PDF

Power Electronics as an Enabling Technology for Renewable Energy Integration

  • Blaabjerg, F.;Chen, Z.
    • Journal of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.81-89
    • /
    • 2003
  • The global electrical energy consumption is still rising and there is a steady demand to increase the power capacity, to produce, distribute and use the energy as0 efficient as possible and furthermore to set up incentives to save energy at the md-user. Two major technologies will play important roles to fulfill those targets. One is to change the electrical power production sources from the conventional, fossil (and short term) based energy sources to renewable energy resources. The other is to use high efficiency power electronics in power systems for high efficiency and high performance applications. This paper discusses both areas, in particular the power electronic application in wind power integration.

Analysis of Economical efficiency for renewable energy in Steam Power Plant (신재생에너지 적용에 따른 화력발전 경제성분석)

  • Choi, Kyoung-Sik
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.1
    • /
    • pp.11-17
    • /
    • 2014
  • Since the Renewable Portfolio Standard (RPS) would be started in 2012, the use of renewable energy should be 11% of total energy use including bio-fuel in 2030. The economic efficiency for renewable energy in B power plant was considered with the bio-diesel, wind power and solar power. The Net Present Value (NPV) and Benefit/Cost Ratio(BC) were used for the economic efficiency with the cost and benefit analysis. In case of bio-diesel, the cost resulted from the fuel conversion and the benefit would be created with trade and environmental improvement. With regard to wind power and solar power, the construction cost would be required and benefit factors would be same as the bio-diesel. The wind power was the best of economic efficiency of renewable energy as the results of NPV and BC ratio. Whereas, the market of wind power was very popular and the techniques of wind power has been developing rapidly.

Resource Use Efficiency of Electricity Sector in the Maldives

  • SHUMAIS, Mohamed
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.1
    • /
    • pp.111-121
    • /
    • 2020
  • The study measures the resource use efficiency of diesel based power generation in the Maldives and analyses factors which influence efficiency levels. Stochastic frontier analysis (SFA) technique is applied to data on 30 plants over two year period from 2016 to 2017. The study finds that technical efficiency scores varies from 0.44 to 0.98 across power plants. About 33 percent of the plants have scores below the mean technical efficiency score of 0.87. Empirical results indicate ownership and use of solar photovoltaic (PV) have an influence on improving efficiency levels. Privately owned power plants in resort islands obtained higher technical efficiency scores compared to public and community owned power plants. This is a significant finding as the first study that used power plants in tourist sector in a comparative study. Size of the power plants was not found significant, but relatively small installed capacities can also be efficient. This finding is important because in many inhabited islands installed capacities remain oversized compared to the load. The benchmarking exercise offers model power plants that are relatively efficient, for other power plants and policy makers in small islands to learn from.

A Study on an Algorithm of Line Switching and Bus Separation for Alleviating Overloads by the Use of Line Power Tracing and Sensitivity (선로유효전력 Tracing과 민감도를 활용한 선로 과부하 해소 스위칭 및 모선분리 알고리즘에 관한 연구)

  • Lee, Byung-Ha;Hwang, Sung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2007-2016
    • /
    • 2011
  • In this paper, a new algorithm for alleviating overloads in power networks by the use of line power tracing and sensitivity is proposed to perform line switching and bus separation effectively. Also, a new bus separation index based on line power tracing is presented to find the bus to be separated for relieving overloads effectively. By applying the sensitivity of the line flow with respect to the change of the line impedance, both switching-on and switching-off of the lines for alleviating overloads in power networks are performed systematically at once. The number of the considered cases for line switching and bus separation can be greatly reduced and the best combination of line switching and bus separation can be acquired efficiently by the use of the sensitivity and the bus separation index. In order to show the effects of this algorithm, it is applied to a small scale power system of IEEE 39-bus system and practical power systems of KEPCO.

A Survey on the Accidents of the Power Tillers in Korea (동력경운기 이용실태 조사분석(I) -농작업사고에 관하여-)

  • 홍종호;이채식;박호석;박판규;김경수;한성금
    • Journal of Biosystems Engineering
    • /
    • v.5 no.2
    • /
    • pp.58-66
    • /
    • 1980
  • A survey was conducted to investigate the power tiller accidents. Eight provinces were covered for this study, and 278 power tiller owners were selected randomly by computer random generator. The results are summarized as follows : A. Frequency of accident. (1) Each power tiller had an accident 0.98 times a year and once every 361 hours of use. Higher frequency of accident was found during the miscellaneous operations including the preparation for farming operation, and there was one accident for every 92 hours of use. (2) The power tiller, which are more than six years old, met an accident 1.19 times a year , or one every 311 hours of use. This value was the highest one compared with any other group. (3) Kerosene engine power tillers met an accident 0.97 times a year, or one every 389 hours of use. It was one tie a year, or once every 329 hours of use for diesel engine power tillers. (4) Among diesel-engine power tillers, 10 horse-power group showed a higher frequency tillers. B. Cause of accident (1) The accidents of power tiller were mainly of sefety , which occurred due to the lack of attention during the operation and 47.4% of the total accidents. The next was of accidental, which represented 26.3% of the total accidents. (2) High percentage of safety accidents occurred during the preparation for farming operation including adjustment. Most of the accidental accidents occurred during the transportation. (3) Lower frequency of accident was found in the power tiller group which were operated by the 21-40 years old operator in comparison with that of the power tiller which was operated by other age group. Power tillers which were operated by high school graduates experienced less accidents compared to other education levels. C. Damage by accident (1) Eighty seven pescents of the total accidents caused damage to the power tiller operator , and 13 % of the total accidents caused property damage only. (2) With regard to the damage to the power tiller operator, 73.8% of the total accidents caused light injury but 26.3% caused heavy injury. (3) Accidents which occurred during machine preparation , and farming operations caused minor injury to the operator, but the accidents during transportation caused heavy injury which cost more than 15 days for recovery. (4) Among the 39 accidents , which caused property damage 18 accidents were from the transportation . Among the total property damage accidents 53.8% were light one which cost only less than 1,000 won. (5) The property damage from each accident cost 1,017 won, on the average, with regard to the kinds of operation, the highest property damage occurred during transportation work, with the value of 2, 965won.

  • PDF

A Study on the internet performance analysis that use PLC (PLC를 이용한 인터넷 성능 분석에 관한 연구)

  • Nam, Tae-Hee
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.4
    • /
    • pp.245-252
    • /
    • 2007
  • This treatise wishes to estimate internet performance using PLC(Power Line Communication) instead of use existing exclusive line. Hard problem of many communication network mountings and work does solution low class informer with power line simply. If use net by power line with this, can get into enormous gains in side of early expense as well as hard problem of work. This treatise investigated validity about if investigate using power line what level internet utilization can take advantage of, and can activate internet by hereafter first term.

  • PDF

A Study on Optimal Clock Period Selection Algorithm for Low Power RTL Design (저전력 RTL 설계를 위한 최적 클럭 주기 선택 알고리듬에 관한 연구)

  • 최지영;변상준;김희석
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1157-1160
    • /
    • 2003
  • We proposed a study on optimal clock period selection algorithm for low power RTL design. The proposed algorithm use the way of maintaining the throughput by reducing supply voltage after improve the system performance in order to minimize the power consumption. In this paper, it select the low power to use pipeline in the transformation of architecture. Also, the algorithm is important the clock period selection in order to maximize the resource sharing. however, it execute the optimal clock period selection algorithm.

  • PDF