• Title/Summary/Keyword: Usability Measurement

Search Result 183, Processing Time 0.027 seconds

A Study on the Development of a Rapid Safety Assessment System for Buildings Using Seismic Accelerometers (지진가속도 계측기를 이용한 건축물의 긴급 안전성 평가 알고리즘 개발에 대한 연구)

  • Jeong, Seong-Hoon;Jang, Won-Seok;Park, Byung-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.161-170
    • /
    • 2020
  • In this study, develop the seismic acceleration measurement data conversion and signal processing algorithms for improve the operational efficiency of the seismic acceleration measurement system installed for public facilities. Through the analysis of the seismic acceleration time history data, the evaluation methods and criteria and evaluating the safety of buildings were proposed. The system was applied to the test bed building to verify its operation and usability. It is expected to be used as a decision making support data and determining the direction and priority of disaster response in the event of an earthquake.

Deformation Monitoring of Subway Track using by Automatic Measurement (자동화계측을 통한 지하철 궤도 변형 모니터링연구)

  • Jung-Youl Choi;Jae-Min Han
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.579-584
    • /
    • 2024
  • Currently, large-scale, deep construction is being carried out adjacent to subway tracks in korea. when excavating adjacent to each other, it is very important to ensure the safety of earth retaining structures and underground structures. therefore, we are managing the safety of the subway by introducing an automated measurement system. deformation of the subway track during adjacent excavation may affect train running stability. this is a factor that can be linked to train derailments. however, current subway track safety evaluation using automated measurement systems relies only on the maximum value of measured data. therefore, a method to improve the usability of automated measurement system results is needed. in this study, we utilized a technique that can quantitatively evaluate the measurement results of a large amount of subway track deformation. a safety evaluation was conducted on subway track deformation due to adjacent excavation using a vast amount of data using probabilistic statistical analysis techniques.

Biomechanical Effectiveness and Anthropometric Design Aspects of 3-dimensional Contoured Pillow

  • Kim, Jong Hyun;Won, Byeong Hee;Sim, Woo Sang;Jang, Kyung Seok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.503-517
    • /
    • 2016
  • Objective: The aim of this study was to evaluate the effectiveness of 3 dimensional contoured pillow through analyzing contact pressure and to suggest its design guidelines through analyzing the posture of head and neck area. Background: The quality of sleep is a very important factor closely related with human's health. To improve the quality of sleep, the verification of design factors affecting the posture of the head and neck is needed, and a pillow design that can induce proper posture is required. Method: This study measured the contact pressures of the two reference groups (bead and cotton pillows) as a method to evaluate the design effectiveness of the contoured pillow. This study proposed 3-dimensional design guidelines by drawing anthropometry (head length) affecting cervical curvature angle (CCA) through the measurement of the participants' cervical curvature angles. Results: In the design effectiveness evaluation, the contact pressure of cervical region was higher than that of a reference group (cotton pillow), and contract area increased, and contract pressure decreased in the shape distributing the occipital region's body pressure. This study proposed pillow's cervical supporting height by percentile of a head length [head length (%tile) (cervical supporting height) affecting the posture of the head and neck: 14.6cm (5%tile) (6.2cm), 15.5cm (25%tile) (6.7cm), 16.4cm (50%tile) (7.1cm), and 19.3cm (75%tile) (8.9cm)]. Conclusion: This study confirmed the contoured pillow's design effectiveness maintaining cervical angle comfortable to sleep with the shape supporting the cervical vertebrae and by reducing the contact load of the occipital region. Also, this study proposed pillow design guidelines based on the 3-dimensional contoured pillow design effectiveness, through which the study laid the foundation for pillow design in a systematic method. Application: The results of this study are expected to be utilized as the basis data by which the optimum pillow type and pillow design according to main percentile can be standardized.

Comparison of Tympanic and Axillary Temperatures (고막체온과 액와체온의 비교 연구 - 성인대상자를 중심으로 -)

  • Yea, Jae-Hee;Jo, Hyun-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.16 no.2
    • /
    • pp.162-170
    • /
    • 2009
  • Purpose: To verify the usability of tympanic temperature measurement for adults, a comparison of tympanic and axillary temperatures was done. Method: The study was conducted during October 2008, and participants were 110 female nursing students. Axillary temperatures were taken with glass mercury thermometers for 5, 7 and 10 minutes. Tympanic temperatures were taken with Infrared Thermometer IRT 4520 on both ears, twice at a 5-second interval. The data were analyzed using the SPSS 12.0 program. Results: In the 1st measurement, the mean for right tympanic temperatures ($0.06^{\circ}C$) and for left ($0.03^{\circ}C$) were significantly higher than the 2nd. A comparison of mean temperatures for right and left, showed that the mean for the left side on the 1st measurement was significantly higher ($0.01^{\circ}C$) than the right. Also the temperature on left side in the 2nd measurement was higher ($0.04^{\circ}C$) than the right 2nd, but not significantly higher. The mean temperature for right and left tympanic on 1 st and 2nd measurements were significantly higher than axilla for 5 minutes ($0.58^{\circ}C$), for 7 minutes ($0.52^{\circ}C$), and for 10 minutes ($0.43^{\circ}C$). The tympanic temperature was the most closely correlated with the axillary temperature at 10 minutes. Conclusion: Findings indicate that measurement of tympanic temperature is a useful alternative to axillary temperature taken for 10 minutes.

  • PDF

Comparison of Inguinal, Rectal, Axillary,and Tympanic Temperature in Newborns (신생아의 서혜, 직장, 액와, 고막 체온 측정 비교)

  • Koo, Hyun-Young;Son, Jung-Tae
    • Child Health Nursing Research
    • /
    • v.11 no.2
    • /
    • pp.203-210
    • /
    • 2005
  • Purpose: In order to identify the usability of inguinal temperature in a neonatal unit, this study was done to compare inguinal temperature of newborns with rectal, axillary, and tympanic temperatures. Method: Fifty-one normal newborns admitted to the nursery of a university affiliated hospital participated in the study. Tympanic temperatures were taken with a tympanic thermometer. Inguinal, rectal, and axillary temperatures were taken with glass mercury thermometers, and were recorded every 1 minute until the reading remained constant for 2 times. The data were analyzed using the SPSS program. Result: The measurement time for inguinal temperatures in newborns was significantly longer than that for rectal temperatures, but was shorter than that for axillary temperatures. The mean temperature for the newborn's inguinal site was lower than for rectal, axillary, and tympanic temperatures (the lower side), but wasn't different from tympanic temperature (the upper side). The inguinal temperature was significantly correlated with rectal, axillary, and tympanic temperature. The inguinal temperature was not different according to general characteristics of the newborn. Conclusion: These findings indicate that measurement of inguinal temperature is a useful alternative to rectal temperature.

  • PDF

Vidyanusa Mathematic Learning Systems Based on Digital Game by Balanced Design Approach

  • Ramdania, Diena Rauda;Prihatmanto, Ary Setijadi;Kim, Myong Hee;Park, Man-Gon
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.3
    • /
    • pp.603-611
    • /
    • 2016
  • Educational games offer an opportunity to engage and inspire students to take an interest in every subject material in school. The "fun" obtain when playing games become a trigger for the use of games in learning. However, there are doubts whether the players actually learn while they are having fun. Vidyanusa is an Online Mathematics Education Game being developed by Crayonpedia Education Ecosystem in Indonesia. The learning goal of Vidyanusa is to engage junior high school students in learning mathematics. In this paper, we design the Vidyanusa game material Functions and Relations by using Balanced Design Approach. This approach has three models in succession; the Content Model outlines the purpose of the game, the Task Model maps out the mission, and the Evidence Model outlines student measurement. This paper will then discusses the quality of games produced in term of Usability factor for effective results and objective. The measurement of the game was carried out based on International Standard ISO/IEC 9126-1 FDIS about Software Quality Product.

Efficiency Measurement Method and Simplification of Program (프로그램의 효율성 측정 방법과 간소화)

  • Yang, Hae-Sool
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.1
    • /
    • pp.49-62
    • /
    • 1998
  • Softwares which have many functions to satisfy user's requirements is developing. But generally, users use partial functions of software. If we could construct software which leave useful functions and remove unuseful functions in software with many functions, we could enhance execution efficiency by reduction of program size and quality of software. There are 6 items in international standard ISO/IEC 9126 about quality of software. These are functionality, reliability, usability, efficiency, maintenance and portability. In this study, we proposed metrics for measurement of efficiency and simplification method for source code. And we described products evaluation result and indicated problem and progress method for practical development project about proposed efficiency metrics.

  • PDF

The Qualitative Study on the Evaluation and the Application of 3D scan and virtual try-on technology (3차원 스캔과 가상 착의 기술의 평가와 활용에 관한 질적연구)

  • Choi, Young-Lim;Nam, Yun-Ja
    • Fashion & Textile Research Journal
    • /
    • v.11 no.3
    • /
    • pp.437-444
    • /
    • 2009
  • According to the activation of the fashion electronic commerce, this research investigated the merits and demerits and improvement plan of the 3D virtual try-on technology using the qualitative research method. This research was performed by interview with 70 evaluation group. The evaluation group of 3D virtual try-on was organized and the fit evaluation process by 3D human body scan and the 3D virtual try-on of the i-Fashion technology center were experienced. This study was performed by interview after the actual and virtual try-on about the casual shirt. The convenience and accuracy of measurement, usability in online shopping, body evaluation, complement of sizing system, and body shape management were discovered as merits. The requirement of high accuracy in sizing and avatar, limits of fabric expression, practical limitation by cost, vexatious of measurement garment, differences between real and virtual fittings, personal information leakage risk, and etc were pointed out as demerits. The mass customization, customized garment connected with medical service, humanized avatar, improved fitting report, entertainment, coordination, wardrobe manager were proposed as improvement plan.

Application Review of Portable Slip Meter(ONO.PPSM) (휴대형 미끄럼시험기 (ONO.PPSM)의 적용성 검토)

  • Baek, Koen-Hyuk;Shin, Yoon-Ho;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.219-223
    • /
    • 2009
  • This paper is the result of investigation of ONO PPSM(ONO PORTABLE SLIP METER) by way of experiment to see the validity as a slip meter, ONO PPSM is a portable slip meter which was made up for the weak points of O-Y PSM(ONO-YOSHIOKA PULL SLIP METER) which takes an accurate measurement of the slip resistance but very heavy and hard to operate. In order to know the stability of the measurement result of ONO PPSM, we measured the slip resistance against 4 different kind of floor materials. As a result of this, we found out that the coefficient of variability of CSR' is less than 0.05. Also, we verified the relation between CSR' and CSR. more specifically by doing the slip test against 7 different kinds of inorganic matter floor materials. We increased the usability of ONO PPSM as a slip meter by suggesting the method of sharing the evaluation index of slip of CSR' and C.S.R.

  • PDF

A Study of Matrix Model for Core Quality Measurement based on the Structure and Function Diagnosis of IoT Networks (구조 및 기능 진단을 토대로 한 IoT네트워크 핵심품질 매트릭스 모델 연구)

  • Noh, SiChoon;Kim, Jeom Goo
    • Convergence Security Journal
    • /
    • v.14 no.7
    • /
    • pp.45-51
    • /
    • 2014
  • The most important point in the QoS management system to ensure the quality of the IoT system design goal is quality measurement system and the quality evaluation system. This research study is a matrix model for the IoT based on key quality measures by diagnosis system structure and function. Developing for the quality metrics measured Internet of Things environment will provide the foundation for the Internet of Things quality measurement/analysis. IoT matrix system for quality evaluation is a method to describe the functional requirements and the quality requirements in a single unified table for quality estimation performed. Comprehensive functional requirements and quality requirements by assessing the association can improve the reliability and usability evaluation. When applying the proposed method IoT quality can be improved while reducing the QoS signaling, the processing, the basis for more efficient quality assurances as a whole.