• 제목/요약/키워드: Urine Analysis

검색결과 773건 처리시간 0.025초

중증 손상 기전의 안정된 환자에서 중증도 예측 인자들에 대한 다변량 분석 (Multivariate Analysis of Predictive Factors for the Severity in Stable Patients with Severe Injury Mechanism)

  • 이재영;이창재;이형주;정태녕;김의중;최성욱;김옥준;조윤경
    • Journal of Trauma and Injury
    • /
    • 제25권2호
    • /
    • pp.49-56
    • /
    • 2012
  • Purpose: For determining the prognosis of critically injured patients, transporting patients to medical facilities capable of providing proper assessment and management, running rapid assessment and making rapid decisions, and providing aggressive resuscitation is vital. Considering the high mortality and morbidity rates in critically injured patients, various studies have been conducted in efforts to reduce those rates. However, studies related to diagnostic factors for predicting severity in critically injured patients are still lacking. Furthermore, patients showing stable vital signs and alert mental status, who are injured via a severe trauma mechanism, may be at a risk of not receiving rapid assessment and management. Thus, this study investigates diagnostic factors, including physical examination and laboratory results, that may help predict severity in trauma patients injured via a severe trauma mechanism, but showing stable vital signs. Methods: From March 2010 to December 2011, all trauma patients who fit into a diagnostic category that activated a major trauma team in CHA Bundang Medical Center were analyzed retrospectively. The retrospective analysis was based on prospective medical records completed at the time of arrival in the emergency department and on sequential laboratory test results. PASW statistics 18(SPSS Inc., Chicago, IL, USA) was used for the statistical analysis. Patients with relatively stable vital signs and alert mental status were selected based on a revised trauma score of more than 7 points. The final diagnosis of major trauma was made based on an injury severity score of greater than 16 points. Diagnostic variables include systolic blood pressure and respiratory rate, glasgow coma scale, initial result from focused abdominal sonography for trauma, and laboratory results from blood tests and urine analyses. To confirm the true significance of the measured values, we applied the Kolmogorov-Smirnov one sample test and the Shapiro-Wilk test. When significance was confirmed, the Student's t-test was used for comparison; when significance was not confirmed, the Mann-Whitney u-test was used. The results of focused abdominal sonography for trauma (FAST) and factors of urine analysis were analyzed using the Chi-square test or Fisher's exact test. Variables with statistical significance were selected as prognostics factors, and they were analyzed using a multivariate logistics regression model. Results: A total of 269 patients activated the major trauma team. Excluding 91 patients who scored a revised trauma score of less than 7 points, 178 patients were subdivided by injury severity score to determine the final major trauma patients. Twenty-one(21) patients from 106 major trauma patients and 9 patients from 72 minor trauma patients were also excluded due to missing medical records or untested blood and urine analysis. The investigated variables with p-values less than 0.05 include the glasgow coma scale, respiratory rate, white blood cell count (WBC), serum AST and ALT, serum creatinine, blood in spot urine, and protein in spot urine. These variables could, thus, be prognostic factors in major trauma patients. A multivariate logistics regression analysis on those 8 variables showed the respiratory rate (p=0.034), WBC (p=0.005) and blood in spot urine (p=0.041) to be independent prognostic factors for predicting the clinical course of major trauma patients. Conclusion: In trauma patients injured via a severe trauma mechanism, but showing stable vital signs and alert mental status, the respiratory rate, WBC count and blood in the urine can be used as predictable factors for severity. Using those laboratory results, rapid assessment of major trauma patients may shorten the time to diagnosis and the time for management.

레이저 유발형광법을 이용한 우라늄 작업자의 뇨 형광 분석 (An Improved Laser-Induced Fluorimetry for Assay of Uranium in Urine)

  • Lee, Sang-Mok;Shin, Jang-Soo;Kim, Cheol-Jung
    • Nuclear Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.255-258
    • /
    • 1993
  • 펄스형 질소레이저를 사용한 time-resolved laser-induced fluorimetry를 이용하여 우라늄 작업자의 뇨속에 함유되어 있는 우라늄의 농도를 간단한 전처리만으로 정량분석하는 방법을 연구하였다. 형광분석할 때에 뇨에 함유된 chloride ion은 우라늄 형광을 심하게 quenching하는 것으로 알려져 있으며, 따라서 이를 제거하기 위한 전처리 과정에서 많은 시간 소모와 큰 실험 오차를 유발하고 있다. 본 방법에서는 10% Fluran 수용액을 뇨에 첨가하여 뇨함량이 약 1% 정도가 되었을 때 뇨속의 chloride에 의한 quenching 영향을 최소한으로 줄일 수 있었으며, 시간 0에서의 형광강도를 계산하여 형광강도의 농도에 대한 직선성을 측정한 결과 우라늄 농도 범위 10-500 ppb에서 우수한 직선성을 나타내었다.

  • PDF

D체와 R체 이성질체 판별과 GC-MS를 이용한 유전성 대사이상질환의 진단법 개발 (Diagnostic Method for Inborn Metabolic Disorders using differentiation between D- and R- Isomers on GC-MS)

  • 윤혜란
    • 대한유전성대사질환학회지
    • /
    • 제15권2호
    • /
    • pp.65-71
    • /
    • 2015
  • Since the secretion of specific chiral isomers in urine (or plasma) is very crucial to diagnose some inborn metabolic disorders, clinical application of dual column achiral differential method has been performed for the absolute configuration of chiral compounds. Extracted from the acidified urine with diethyl ether, carboxylic functional group of organic acid (stereoisomers of the volatile) was derivatized with (-)-menthylation or (S)-(+)-3-methyl-2-butylation and followed by O-trifluoroacylation. Each of the enantiomers was accurately separated from the library matched double column (achiral) with a retention index (I). In various inborn metabolic disease urines, absolute chirality was identified correctly in the urine (10 patients) with inborn metabolic disease (including secretion of D, L- lactic acid, D, L-3-hydroxybutyric acid, and D, L-2-hydroxyglutaric acid). In this study, we identified and isolated the volatile diastereomer as a useful diagnostic marker, this successful application to urine specimens may be useful for diagnostic classification of inherited metabolic disorders.

피부 마사지가 미숙아의 스트레스 호르몬에 미치는 효과 (The Effects of Massage on Stress Hormone in Premature Infants)

  • 유경희
    • Child Health Nursing Research
    • /
    • 제11권1호
    • /
    • pp.125-131
    • /
    • 2005
  • Purpose: This study was done to evaluate the effects of massage on the level of stress hormone in the urine in preterm infants. Method: The design was a nonequivalent control group pretest-posttest design quasi experimental study. Fifty-eight preterm infants were assigned to the experimental(31) or control group(27). The data were collected from March 2002 to August 2003. The massage stimulation was provided to infants in the experimental group for 15-minutes twice a day for 10 days. On day 1 and day 10 of the study, a 24 hour-urine sample was collected for norepinephrine, epinephrine, and cortisol assays. In data analysis, SPSSWIN 10.0 program was utilized for descriptive statistics, ANOVA and t-test. Results: General characteristics of the two groups showed no significant differences, thus the two groups were found to be homogenous. The 24 hour-urine cortisol of the massage group (t=4.61, p=.000) was significantly reduced compared to the control group after 10 days. Conclusions: The results suggest that the massage stimulation can be used to reduce 24 hour-urine cortisol in preterm infants. Therefore, massage provided in the incubator is recommended for reduction of stress in preterm infants who are hospitalized in neonatal intensive care units.

  • PDF

심혈관계 질환 위험요인으로서의 중금속 - 납과 수은에 대한 분석 - (Heavy Metal as Risk Factor of Cardiovascular Disease - An Analysis of Blood Lead and Urinary Mercury)

  • 김대선;유승도;차정훈;안승철;이은희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제38권4호
    • /
    • pp.401-407
    • /
    • 2005
  • Objectives : We wanted to investigate the relationship between heavy metal, especially lead and mercury, to the blood pressure and cholesterol level in children. Methods : This study was undertaken in three primary schools and the study subjects were a total of 274 children. The lead in the blood and the urine mercury were analyzed by performing atomic absorption spectroscopy. Results : All of participants' blood lead levels and urine mercury concentrations were below the suggested level of concern according to the criteria of the CDC and ATSDR. We found no significant correlation between lead, mercury and the blood pressure. The blood lead level did not show any relationship with the blood pressure and cholesterol. However, the urine mercury levels were associated with the serum cholesterol. Conclusion : Our study suggests that mercury can induce an increase of cholesterol as a risk factor of myocardial infraction and coronary/cardiovascular disease.

글로우 방전을 이용한 혈청과 뇨의 분석기술 개발 (Development of Analytical Techniques for Human Serum and Urine by Using Glow Discharge)

  • 이상천;최경수;손은호;심영진
    • 분석과학
    • /
    • 제11권3호
    • /
    • pp.167-173
    • /
    • 1998
  • Electrothermal Vaporization-Hollow Cathode Glow Discharge-Atomic Emission Spectrometer(ETV-HCGD-AES)를 이용하여 혈청과 뇨에 함유된 중금속 원소들의 분석을 시도하였다. 먼저 글로우 방전셀을 목적에 맞게 설계하고, 미국 NIST로부터 구입한 표준시료인 혈청과 뇨를 사용하여 미량분석을 위한 기초실험을 수행하였다. 전처리를 하지 않은 시료의 분석에서 새로이 개발한 ETV-HCGD-AES는 수은이나 납 등의 검출에서 ICP-OES보다 상대적으로 전처리가 거의 필요없었으며 감도와 선택성에서도 우수함을 관찰하였다.

  • PDF

GC/MS를 이용한 소변 중 Pseudoephedrine과 Dexrormethorphan 및 대사체의 동시분석 (Determination of pseudoephodrine, dextromethorphan and their metabolites in human urine by gas chromatography - mass spectrometry)

  • 이원웅;안성호;이성우;홍종기
    • 분석과학
    • /
    • 제20권4호
    • /
    • pp.315-322
    • /
    • 2007
  • 본 연구는 1명의 건강한 성인남자로부터 pseudoephedrine과 dextromethorphan 복합제제 약물의 복용 후 24시간동안 배설된 소변을 채취하여 이들 혼합약물의 대사과정과 배설에 관하여 연구를 수행 하였다. 소변 중에 약물과 대사체의 검출을 위하여 가수분해 및 추출과정을 거쳐 MSTFA와 MBTFA를 사용하여 유도체 반응 후 GC-MS로 동시 분석을 수행하였다. 각 대사체는 질량스펙트럼의 해석을 통하여 구조가 규명되었으며, 시간에 따른 모 약물과 대사체의 배설율을 조사하였으며, 본 실험결과로부터 pseudoephedrine과 dextromethorphan의 체내 대사경로를 제안하였다.

환경 Stress에 의한 횐쥐뇨중 catecholamine의 변화 (Variations of Catecholamine Contents in Rat Urine by Environmental Stress)

  • 김형석
    • Environmental Analysis Health and Toxicology
    • /
    • 제3권3_4호
    • /
    • pp.9-15
    • /
    • 1988
  • The word of stress crime from Latin language as stringere and it was used in medical fields from 1935. According to Selye, all the biological bodies reveal physilolgical changes when some stimulation exceed normal levels, and consequently the pituitary gland and adrenal systems are activated. Jacob expressed that stress is the loss of homeostasis by physical, chemical, and emotional stimulation. When biological organisms receive extreme stress the amount of catecholamine excretion are increase. Author investigated the catecholamine contents in rat urine after giving the low temperature stress, noise stress, and water immersion stress. The 24 hours rat urine was collected by adding 1 ml 6 N-HCl and the sample is passed through Bio-Rex 70 samples treatment column to extract catecholamine and detected the catecholamine with HPLC-fluorescence detetor. The highest epinephrine concentration was 67.14 ng in water immersion stress condition and the dopamine concentration of 221.37 ng was shown in the low temperature stress condition.

  • PDF

SCREENING OF BENZODIAZEPINES IN URINE BY THE IMMUNOASSAY AND QUANTITATION BY GC-NPD METHOD

  • Park, Jongsei;Park, Jeongeum;Park, Myung-Ja
    • Toxicological Research
    • /
    • 제7권1호
    • /
    • pp.21-27
    • /
    • 1991
  • We developed a simple method to determine benzodiazepines in biological samples using electron capature detectors and nitrogen-phosphorous detectors. The extraction of 13 benezodiazepines in urine at pH 9.5 with toluene and its analysis in GC/NPD showed the peaks in 9-16 min. In this retention time range, the biological backaground was fairly low and the drugs could be identified in low concentrations. The benzodiazepines in urine samples were screened by the fluorescence polarization immunoassay and positive samples were confirmed by the GC/NPD method.

  • PDF

Diagnostic Ex-Vivo Assay of glucose Using Diabetic-Control Circuits

  • Ly, Suw Young;Lee, Chang Hyun;Yoo, Hai-Soo
    • 한국응용과학기술학회지
    • /
    • 제32권4호
    • /
    • pp.724-730
    • /
    • 2015
  • For ex-vivo diabetic control, the voltammetric diagnosis of glucose (GU) was conducted with a modified carbon nanotube paste electrode, using handheld analytical circuits. The optimum analytical conditions were attained within the 0.5-4.0 ug/L working range and at the 0.06 ug/L detection limit, which system was interfaced to the feedback circuits and was applied to human urine for diabetic-patient diagnosis. It can be used for ex-vivo flow control analysis, vascular flow detection and other medicinal assays. The equations of the patients' urine are y=36.65x+12.13 and $R^2=0.987$, those of the healthy person of y= 2.5x+10.9 and $R^2=0.928$ (patients: 118 ug/L; healthy person: 12.34 ug/L).