• Title/Summary/Keyword: Urine$

Search Result 2,996, Processing Time 0.032 seconds

The Relationship Between Airborne Trichloroetnylene Concentrations and Total Trichloro-compounds and Trichloroacetic Acid in Urine (근로자의 트리클로로에틸렌 폭로 농도와 요중 총삼염화물 및 삼염화초산 농도와의 관계)

  • Jeon, Hasub;KIm, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.7-16
    • /
    • 1994
  • This study was designed to establish the relationship between airborne trichloroethylene concentrations and total trichloro-compounds and trichloroacetic acid in urine samples of the trichloroethylene exposed workers, to examine if the biological screening value for trichloroacetic acid in urine set by the Ministry of Labor is appropriate, and to suggest a suitable biological screening value for total trichloro-compounds in urine. Seventy male workers from the cleaning, the packing, and the inspcetion areas were selected as the study group and eighty male office workers were chosen as the control group. The results were as follows: 1. The mean values of total trichloro-compounds and trichloroacetic acid in the exposed group ($48.1{\pm}1.5mg/{\ell}$, $19.7{\pm}1.9mg/{\ell}$) were significantly higher than those in the control group($4.3{\pm}1.5mg/{\ell}$, $1.8{\pm}1.2mg/{\ell}$). 2. The airborne tichloroethylene concentrations were significantly related with the concentrations of total trichloro-compounds in urine(r=0.8212) and the concentrations of trichloroacetic acid in urine(r=0.7216). 3. The average trichloroethylene concentrations in the manual cleaning plants and that in the automatic cleaning plants were 40.1 ppm and 7.7 ppm, respectively. The difference between two groups was statistically significant. 4. The geometric mean of 49.6 ppm trichloroethylene concentration was resulted in the $185.4mg/{\ell}$ total trichloro-compounds in urine, and the 50 ppm trichloroethylene concentration was expected to produce $170.4{\pm}28.5mg/{\ell}$ total trichloro-compounds in urine. 5. With the geometric mean of 49.6 ppm trichloroethylene concentration, the corresponding geometric mean concentration of trichloroacetic acid in urine was $74.7mg/{\ell}$. In conclusion, the level of personal exposure to trichloroethylene concentration was significantly correlated with the concentrations of total trichloro-compounds and trichloroacetic acid in urine. Current biological screening value of $75mg/{\ell}$ for trichloroacetic acid in urine set by the Ministry of Labor was thought to be appropriate, and a biological screening value for total trichloro-compounds in urine should be set in the range of $170.4{\pm}28.5mg/{\ell}$ as a reference value for trichoroethylene exposure.

  • PDF

Effect of storage time and temperature on levels of phthalate metabolites and bisphenol A in urine

  • Guo, Ying;Wang, Lei;Kannan, Kurunthachalam
    • Advances in environmental research
    • /
    • v.2 no.1
    • /
    • pp.9-17
    • /
    • 2013
  • Urine is a widely used matrix in biomonitoring studies on the assessment of human exposure to environmental chemicals such as phthalate esters and bisphenol A (BPA). In addition to the need to apply valid analytical techniques, assurance of specimen integrity during collection and storage is an important prerequisite for the presentation of accurate and precise analytical data. One of the common issues encountered in the analysis of non-persistent contaminants is whether shipping and storage temperature and time since collection have an effect on sample integrity. In this study, we investigated the stability of phthalate metabolites and BPA in spiked and unspiked urine samples stored at room temperature ($20^{\circ}C$) or at $-80^{\circ}C$ for up to 8 weeks. Concentrations of phthalate metabolites declined, on average, by 3% to 15%, depending on the compounds, and BPA declined by ~30% after 4 weeks of storage of spiked urine samples at $20^{\circ}C$. In a test of 30 unspiked urine samples stored at $20^{\circ}C$ and at $-80^{\circ}C$ for 8 weeks, the concentrations of phthalate metabolites and BPA decreased by up to 15% to 44%, depending on the compound and on the samples. It was found that the small reduction in phthalate concentrations observed in urine, varied depending on the samples. In a few urine samples, concentrations of phthalate metabolites and BPA did not decline even after storage at $20^{\circ}C$ for 8 weeks. We found a significant relationship between concentrations of target analytes in urine stored at $20^{\circ}C$ and at $-80^{\circ}C$ for 8 weeks. We estimated the half-lives of phthalate metabolites and BPA in urine stored at $20^{\circ}C$. The estimated half-life of monoethyl phthalate (mEP) and mono (2-ethyl-5-carboxyphentyl) phthalate (mECPP) in urine stored at $20^{\circ}C$ was over two years, of mono (2-ethyl-5-oxohexyl) phthalate (mEOHP) and monobenzyl phthalate (mBzP) was approximately one year, and of other phthalate metabolites was approximately 6 months. The estimated half-life of BPA in urine stored at $20^{\circ}C$ was approximately 3 months, which is much longer than that reported for aquatic ecosystems.

The Study on the Prevalence and Significance of Urinary HBsAg. Detection (요중(尿中) B형(型) 간염항원(肝炎抗原) 발현(發現)의 의의(意義)에 관(關)한 연구(硏究))

  • Han, Jin-Suk;Pyo, Heui-Jung;Shin, Young-Tae;Park, Jeong-Sik;Kim, Suhng-Gwon;Choe, Kang-Won;Lee, Jung-Sang;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.15 no.1
    • /
    • pp.27-32
    • /
    • 1981
  • HBsAg. was identified in the urine of the patients positive for serum HBsAg. by Tripatzis in 1970. In 1977, Hourani et al reported the incidence of HBsAg. in urine was about 52% in the patients positive for serum HBsAg. with hemodialysis treatment due to chronic renal failure. A series of studies on the HBsAg. in urine has revealed the urine of the patients positive for serum HBsAg. to be important source of infection. But there's much room to debate on the relationship of HBsAg. in urine with infectivity and the exact mechanism of urinary emergence of HBsAg. The authors detected HBsAg. in serum and urine by employing sandwitch solid-phase rad ioimmunoassay, and performed urinalysis, liver function test and renal function evaluation. Percutanous liver and/or kidney biopsis were done. Among 38 renal disease patients, 9 cases (23.4%) were shown to be positive for serum HBsAg. and 5 cases (55.5%) among above 9 patients positive for urine HBsAg.. 56 cases (67.4%) of 83 liver disease patients revealed positive for serum HBsAg. but only 11 cases (13.2%) among the 56 cases positive fo urine HBsAg. All 10 renal and liver disease patients revealed positive serum HBsAg., and among the 9 cases (90%) positive for urine HBsAg.. In the 25 patients positive for urine HBsAg. all of 5 renal patients and 9 renal and liver patients had hematuria or/and proteinuria above 2 positive for albumin. But in the 11 liver patients 6 cases (55.1%) were normal findings. And there's no significant difference in cpm of urine HBsAg. between the patient positive for serum HBsAg. and negative, and in cpm of serum HBsAg. between liver and renal disease patients. But there's statistical significance in cm of urine HBsAg. between renal and liver diseases.

  • PDF

Determination and Application of 3-Methylhistidine Levels in Urine (뇨(尿)중 3-Methylhistidine 함량의 측정과 이용)

  • 정수현;서형주
    • The Korean Journal of Food And Nutrition
    • /
    • v.9 no.2
    • /
    • pp.213-216
    • /
    • 1996
  • A modified method is given for the precolumn derivatization and subsequent high-pressure liquid chromatographic seperation of 3-methylhistidine from urine. The elution contained isocratic solution with acetonirile and 10 M sodium phosphate(pH 7.5) requires less than 7 min. The recoveries of 3-methylhlstidine from urine control were 95% to 106%. 3-Methylhistidine determinations were performed on urine samples from volunteers who were both male trained and non-trained physical undergraduates. As the result, urinary .3-methylhistidine content of volunteers increased significantly after weight training.

  • PDF

A Study on Acid-fast Bacteria in Urine (尿中 抗酸菌에 관한 연구)

  • Park, Chung-Oh;Lee, Hyeong-Choon
    • Journal of Environmental Health Sciences
    • /
    • v.13 no.1
    • /
    • pp.63-65
    • /
    • 1987
  • A study on detection rates of acid-fast bacteria in urine by three sampling methods was performed on 898 cases randomly sampled from peoples who visited Dr. Chung's Health Lab. from January to December, 1983. Positive rate by 5 times sampling of motring urine was 7.0% and 12.5% higher than that of 24 hours sampling. Therefore, 5 times sampling of morning urine method was considered to be desirable method for the test of ambulatory cases.

  • PDF

The effect of Corni Fructus on renal function

  • Jeong, Myung-Kum;Yang, Ki-Sook
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.385.2-385.2
    • /
    • 2002
  • Cornus officinalis has been used as protective drug for liver and kidney function. In order to evaluate the effect on renal function of Corni Fructus. We measured urine volume, chemical parameters(urea nitrogen. creatinine, uric acid). electrolytes($Na^{+}$, $K^{+}$, $Cl^{-}$) in serum and urine. Furosemide showed significant urine volume. serum and urine parameters, but Corni Fructus showed normal level parameters by dose increasing in rats.

  • PDF

Factors affecting the contamination of bag urine culture in febrile children under two years (2세 미만의 열성 환아에서 소변 주머니를 이용한 소변 배양 검사의 오염률에 영향을 미치는 인자)

  • Choi, Wook Hyun;Lim, In Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.3
    • /
    • pp.346-350
    • /
    • 2009
  • Purpose : Since children under two years with suspected urinary tract infections (UTIs) cannot control urination, urine cultures in such children are usually performed via urine bags. This method is noninvasive but has a high contamination rate. We studied the contamination rate of bag urine culture in diagnosing UTI in infants under two years and the factors responsible for contamination. Methods : We examined patients under 2 years in whom urine culture through the urine bag method yielded over 105 colonies of a single pathogen. We defined UTI by referring to the guidelines of The Korean Society of Pediatric Nephrology, 2005. We examined the factors responsible for contamination according to sex, duration of urine collection, and whether diarrhea took place with contamination rate. Results : We examined 717 patients (412 males and 305 females). The contamination rate of one bag urine culture was 37.9%. Gender was not related to the contamination rate (P>0.05). Duration of urine collection showed an association with the contamination rate. The longer the duration of collecting urine, the higher was the contamination rate. Duration of urine collection was divided into three groups: first group, <2 hours; second group, 24 hours; and third group, ${\geq}4$ hours. Contamination rates were 30.0%, 42.2%, and 43.7% for the first, second, and third groups, respectively, with statistical significance (P=0.001). Diarrhea at admission had no impact on the contamination rate (P>0.05). Conclusion : The contamination rate of urine culture in the examined patients was 37.9%. Gender and diarrhea symptoms were not responsible for contamination. In infants with a suspected UTI, urine should be collected within 2 hours through the urine bag method. If urine collection takes >2 hours, the urine bag should be resterilized and reattached to the patient.

Selection of Unnecessary Urine Culture Specimens Using Sysmex UF-5000 Urine Flow Cytometer (Sysmex UF-5000 소변 유세포분석기를 이용한 요배양 불필요 검체의 선별)

  • Song, Duyeal;Lee, Hyun-Ji;Jo, Su Yeon;Lee, Sun Min;Chang, Chulhun L.
    • Annals of Clinical Microbiology
    • /
    • v.21 no.4
    • /
    • pp.75-79
    • /
    • 2018
  • Background: Urine culture is one of the most frequently requested tests in microbiology. Automated urine analyzers yield much infection-related information. The Sysmex UF-5000 analyzer (Sysmex, Japan) is a new flow cytometry urine analyzer capable of quantifying urinary particles, including bacteria, WBCs, and yeast-like cells (YLCs) and can provide a Gram stainability flag. In this work, we evaluated how many unnecessary urine cultures could be screened out using the UF-5000. Methods: We compared the culture results of 126 urine samples among 453 requested urine cultures (from sources other than the Urology and Nephrology departments) with urinalysis results. Urine cultures were considered positive if bacterial or YLC growth was ${\geq}10^4CFUs/mL$. Results: We used urinalysis cut-off values of $50/{\mu}L$ and $100/{\mu}L$ for bacteria and YLC, respectively. Forty eight of the 126 (38.1%, or 10.6% of 453 requested) cultures were below these cut-off values and did not contain any culture-positive samples. Conclusion: Bacteria and YLC counts generated using the UF-5000 analyzer could be used to screen out negative cultures and reduce urine culture volume by ~10% without sacrificing detection of positive cultures.

Comparison of Intelligent Color Classifier for Urine Analysis (요 분석을 위한 지능형 컬러 분류기 비교)

  • Eom Sang-Hoon;Kim Hyung-Il;Jeon Gye-Rok;Eom Sang-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.7
    • /
    • pp.1319-1325
    • /
    • 2006
  • Urine analysis is basic test in clinical medicine using visual examination by expert nurse. Recently, this test is measured by automatic urine analysis system. But, this system has different results by each instrument. So, a new classification algorithm is required for accurate classify and urine color collection. In this paper, a intelligent color classifier of urine analysis system was designed using neural network algorithm. The input parameters are three stimulus(RGB) after preprocessing using normalization. The fuzzy inference and neural network ware constructed for classify class according to 9 urine test items and $3{\sim}7$ classes. The experiment material to be used a standard sample of medicine. The possibility to adapt classifier designed for urine analysis system was verified as classifying measured standard samples and observing classified result. Of many test items, experimental results showed a satisfactory agreement with test results of reference system.

Urinary Cadmium Concentration of Residents around Industrial Complex in Gwangyang and Yeosu (국가산단지역(광양, 여수) 일부 주민들의 소변 중 카드뮴 농도에 관한 연구)

  • Park, Heejin;Kang, Tack-Shin;Lee, Jong-Dae;Kim, Geun-Bae;Yu, Seungdo;Jang, Bong-Ki;Lee, Jong-Wha;Son, Bu-Soon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.338-345
    • /
    • 2015
  • Objectives: The objective of this study was to evaluate the distribution of urine cadmium levels of residents in the surrounding areas of an industrial complex. Methods: During the period of three month from August to October 2012, informed consent was obtained from a total of 362 residents in Kwangyang and Yeosu. We collected urine sample from all subjects and their demographic characteristics, including alcohol drinks and smoking habits, using a questionnaire. The urine samples were analyzed using atomic absorption spectrometer. Results: The urinary cadmium geometric mean concentration of total participants was $0.87{\mu}g/g\;cr$. The results of this study showed that higher urine cadmium levels were observed in females and some subjects with a higher level of education level and a lower BMI. Also, those subjects who preferred to take vegetables and took fish 3 days before urine sampling procedure revealed higher urine cadmium concentrations. The urine cadmium concentrations of subjects in the exposed area($0.91{\mu}g/g\;cr$) were significantly higher than those in the control area($0.78{\mu}g/g\;cr$). Conclusions: An additional study is needed to assess health risks of residents in the vicinity of environment-unfriendly areas, coupled with endeavors to examine possible heavy metals contamination factors that may affect the human body.