• Title/Summary/Keyword: Urban lighting

Search Result 104, Processing Time 0.033 seconds

Electrical Resistivity Imaging for Upper Layer of Shield TBM Tunnel Ceiling (쉴드 TBM터널 상부 지반 연약대 전기탐사)

  • Jung, Hyun-Key;Park, Chul-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.401-408
    • /
    • 2005
  • Recently shield TBM tunnellings are being applied to subway construction in Korean cities. Generally these kinds of tunnellings have the problems in the stability of ground such as subsidence because urban subway is constructed in the shallow depth. A sinkhole occurred on the road just above the tunnel during tunneling in Kwangju, so a survey for upper layer of the tunnel was needed. But conventional Ground Probing Radar can't be applicable due to the presence of steel-mesh screen in the shield segment, so no existent geophysical method is applicable in this site. Because the outer surface of each shield segment is electrically insulated, dipole-dipole resistivity method which is popular in engineering site investigation, was tried to this survey for the first time. Specially manufactured flexible ring-type electrodes were installed into the grouting holes at an interval of 2.4 m on the ceiling. The K-Ohm II system which has been developed by KIGAM and tested successfully in many sites, was used in this site. The system consists of 1000Volt-1Ampere constant-current transmitter, optically isolated 24 bit sigma-delta A/D conversion receiver - maximum 12 channel simultaneous measurements, and graphical automatic acquisition software for easy data quality check in real time. Borehole camera logging with circular white LED lighting was also done to investigate the state of the layer. Measured resistivity data lack of some stations due to failing opening lids of holes, shows general high-low trend well. The dipole-dipole resistivity inversion results discriminate (1) one approximately 4 meter diameter cavity (grouted but incompletely hardened, so low resistivity - less than $30{\Omega}m$), (2) weak zone (100-200${\Omega}m$), and (3) hard zone (high resistivity - more than 1000${\Omega}m$) very well for the distance of 320 meters. The 2-D inversion neglects slight absolute 3-D effect, but we can get satisfactory and useful information. Acquired resistivity section and video tapes by borehole camera logging will be reserved and reused if some problem occurs in this site in the future.

  • PDF

An Analysis of Long-Term Variation of PM10 Levels and Local Meteorology in Relation to Their Concentration Changes in Jeju (제주지역 미세먼지의 장기변동 및 농도변화에 관한 국지기상 분석)

  • Park, Yeon-Hee;Song, Sang-Keun;Lee, Soo-Jeong;Kim, Suk-Woo;Han, Seung-Bum
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.107-125
    • /
    • 2016
  • Long-term variations of $PM_{10}$ and the characteristics of local meteorology related to its concentration changes were analyzed at 4 air quality sites (Ido-dong, Yeon-dong, Donghong-dong, and Gosan) in Jeju during two different periods, such as PI (2001-2006) and PII (2007-2013), over a 13-year period. Overall, the long-term trend of $PM_{10}$ was very slightly downward during the whole study period, while the high $PM_{10}$ concentrations in PII were observed more frequently than those in PI. The concentration variations of $PM_{10}$ during the study period was clarified in correlation between $PM_{10}$ and meteorological variables, e.g. the low (high) $PM_{10}$ concentration with large (small) precipitation or high (low) radiation and in part high $PM_{10}$ concentrations (especially, Donghong-dong and Gosan) with strong wind speed and the westerly/northwesterly winds. This was likely to be caused by the transport effect (from the polluted regions of China) rather than the contribution of local emission sources. The $PM_{10}$ concentrations in "Asian dust" and "Haze" weather types were higher, whereas those in "Precipitation", "Fog", and "Thunder and Lighting" weather types were lower. The contribution of long-range transport to the observed $PM_{10}$ levels in the urban center (Ido-dong, Yeon-dong, and Donghong-dong), if estimated by comparison to the data of the background site (Gosan), was found to explain about 80% (on average) of its input.

Analysis of Sunshine Amount for Education Environment according to Installation of Apartment Structures (아파트 구조물 설치에 따른 교육환경 일조량 분석)

  • Jang, Ho-Sik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.2
    • /
    • pp.117-124
    • /
    • 2012
  • Due to recent urban maintenance project for the aged towns, the reconstruction of apartments into super-high-rise and high-rise apartment structures has been approved for concentrated use of land, and accordingly the infringement on sunshine for nearby residential area is rising as a social issue. Especially the educational environment conditions according to infringement on sunshine in educational facilities are posing many problems. Accordingly in this study, for such sunshine analysis of educational environment, Auto $CAD^{(R)}$ software has been used to construct the 3D model for the educational facility structures. And with the simulation technique, the windows and the schoolyard of the education facility were set to be the lighting standard surface to take measurements for the sunshine environment of the educational facilities by the minute from 8:00AM until 4:00PM for the sunshine amount by true solar time according to the movement of the sun. Also, the sunshine environment of the education facility according to the damage before/after new construction of apartments was charted, and through comparison with the video produced by sun shadow projection method, the sunshine amount of the educational environment could be verified. In future, it is expected to be efficiently used in the sunshine analysis of education environment utilizing such simulation techniques.

GIS Application for Site Planning

  • Han, Seung-Hee;Lee, Jin-Duk
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.1
    • /
    • pp.53-59
    • /
    • 2009
  • The general urban plan is the plane plan which limits general and uniformed constructions; however, the district unit plan is the solid plan that can leads various constructions by discriminating by plot, housing area and lot. Therefore, for the zone plan, not only the two-dimensional plot information such as plot usage plan, but also the three-dimensional plot information needs to be used to analyze lighting, sewerage and directions. To fulfill such requirements, the information can be gathered using GIS and photogrammetric method for the reasonable and efficient zone plan. In this research, the information about the testing area for the zone plan has been gathered using GIS method, and the three-dimensional model about the area has been built using the satellite image and DEM. As the result, plot usage analysis, direction analyst, water system analysis, and slope analysis has been done and used efficiently to build the district unit plan. Also, after the result after applying the analyzed result to the actual area says this is very appropriate and efficient.

  • PDF

Methods of Ensuring Safety for Integrated Fire Protection Shutters at Elementary and Middle Schools (초등학교 및 중학교의 일체형 셔터 안전성 확보 방안)

  • Youn, Hae-Kwon
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.36-45
    • /
    • 2016
  • Integral fire shutters are installed indiscriminately, regardless of evacuation. There is always the risk of an accident because integral shutters are applied mainly to corridors, passages, and stairs of schools This study evaluated the problem of integral shutter's entrance, evacuation, construction management, and maintenance control through a fire shutter accident case, including present condition of fire shutter installed at school of Okgil, Bucheon and Dongtan, Hwaseong. The results suggest that emergency lighting or signs for passage be set up to check location of entrance easily and install obstruction sensors at fire shutter to reduce life damage. In addition, the number of efficiency tests of fire shutters should be increased by running a trial test monthly or weekly to maintain the performance of fire shutter. Schools need to install a fire shutter- applied sprinkler at the entire floor.

Streetscape Design of Arroyo Parkway, Pasadena, California (아로요 파크웨이 조경설계)

  • Jeong Wook-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.4
    • /
    • pp.105-117
    • /
    • 2004
  • The Pasadena Freeway follows the Arroyo Seco through foothills and scenic passes to link Downtown Los Angeles with Pasadena. The approximately 10 mile road was the first freeway built in the West during the 1930's and is today designated as a Historic Parkway. As it approaches Pasadena, it terminates at a traffic light intersection at Glenarm Street, and then becomes a commercial road the Arroyo Parkway. This one and a quarter mile long, north south road moves significant volumes of traffic both into and out of Pasadena. The Arroyo Parkway is thus a major 'gateway' and an important axis of orientation and movement, terminating in the City's core civic, commercial and retail district. Planting, lighting, signage, paving, furnishing and fixtures ought to all be properly designed and coordinated to create a distinctive 'gateway' experience arriving to Pasadena and driving along the Arroyo Parkway. Alternate design studies, developed in discussion with City officials and others involved in the redevelopment of the area, would need to be done to properly decide on the best direction. Issues of heritage and traditional streetscape will likely have to be reconciled with both the reality of the vehicular character of the road and more contemporary themes. Obviously with such large parcels of property available in the Arroyo Fair Oaks corridor, there is a huge potential for redevelopment and building. This potential would only be strengthened by the Light Rail Line and its stations, the improvements to the Arroyo Parkway, and the redevelopment of the Arts Center College of Design. Guides and controls to the development process, including programming and physical design studies, would need to be developed in order to ensure that the maximum potential for the corridor be realized. This concept proposal suggests that the whole strip might be developed as a Arts and Technology corridor, with special emphases on education, public culture, media and lifestyle. The full programming possibilities need to be further developed. Additionally, appropriate urban design guidelines to ensure high quality development also need to be incorporated into an overall development plan.

Comparison assessment of semi-transparent solar cell for BIPV windows (반투과형 태양전지를 이용한 창호형 BIPV 건물의 환경성능 분석)

  • Chung, Min Hee
    • Land and Housing Review
    • /
    • v.11 no.1
    • /
    • pp.87-94
    • /
    • 2020
  • To implement the planning of zero-energy buildings, their energy performance must be improved, and renewable energy applications must also be included. To accelerate the use of renewable energies in such buildings, BIPVs should be actively used in windows and on roofs. Window-type BIPVs are being developed in various forms depending on the size, composition, area ratio of the window, specification of glass, and so on. To analyze the applicability of various solar cells as window-type BIPVs, in this study, we evaluated their applicability, at the current development level, by analyzing the indoor illuminance, heat gain and heat loss; the cooling, heating, and lighting energy levels; and the generation performance of the various solar cells. To enhance the future applicability of window type BIPV, we analyze the overall energy performance of the building, according to changes in visible light transmittance and generation efficiency. The main research results are as follows. The area ratios above the standard illuminance, based on the window type and according to the VLT, were in order of low-e glazing, a-Si window, DSSC window, and c-Si window. The heat gain of the semi-transparent solar cell winodw was remarkably low. The energy consumption of buildings was highest in the order of c-Si window, DSSC window, a-Si window, and clear low-e window. However, in the case of including the power generation performance of the solar cell, the energy consumption was found to be high in order of DSSC window, c-Si window, a-Si window, and clear low-e window. In the future, if a window-type BIPV is developed, we believe that improvement in power generation performance and improvement in visible light transmittance will be needed.

Annual Intensities (2016-2017) Analysis of Energy Use and CO2 Emission by End Use based on Measurements of Sample Apartment Units (표본건물 계측에 의한 공동주택 세대에서의 용도별 에너지사용량 및 CO2 배출량 연간 원단위 (2016 - 2017) 분석)

  • Jin, Hye-Sun;Lim, Han-Young;Lee, Soo-Jin;Kim, Sung-Im;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.7
    • /
    • pp.43-52
    • /
    • 2018
  • In this study, annual site and primary energy use intensities (EUIs) and CO2 emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 50 sample apartment units in Seoul. In addition, estimated site EUIs by end use were compared to the U.S. Residential Energy Consumption Survey (RECS) 2009 data. Site EUIs by end use were found to be in the order of heating > electric appliance > domestic hot water > cooking > lighting > cooling > air movement. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the RECS 2009 data, it was found that site EUIs were very similar for heating, domestic hot water and electric appliance, etc., but slightly different for cooling. The number of sample apartment units will continue to increase until 2020 (total number of samples 200) and intensities data by end use will be continuously updated through continuous collection of measurement data.

Algorithm for Judging Anomalies Using Sliding Window to Reproduce the Color Temperature Cycle of Natural Light (자연광의 색온도 주기 재현을 위한 슬라이딩 윈도우 기반 이상치 판정 알고리즘)

  • Jeon, Geon Woo;Oh, Seung Taek;Lim, Jae Hyun
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.1
    • /
    • pp.30-39
    • /
    • 2021
  • Research in the field of health lighting has continued to advance to reproduce the color temperature of natural light which periodically changes. However, most of this research could only reproduce a uniform circadian color temperature of natural light, therefore failing to realize the characteristics of the circadian cycle of color temperature difference by latitude and longitude. To reproduce the color temperature of natural light on which the characteristics of a region are reflected, the collection technology of real-time characteristics of natural light is needed. If the color temperatures which are not within a periodical pattern due to climate changes, etc., are measured, it will be difficult to judge the occurrence (presence) of the anomalies and to reproduce the circadian cycle of the color temperature of natural light. Therefore, this study proposes an algorithm for judging the anomalies in real time based on the sliding window to reproduce the color temperature of natural light. First, the natural light characteristics DB collected through the on-site measurement were analyzed, the differential values at a one-minute interval were calculated and examined, and then representative color temperature circadian patterns by solar terms were drawn. The anomalies were then detected by the application of the sliding window that calculated the deviation of the color temperature for the measured color temperature data set, which was collected through RGB sensors, while moving along the time sequence. In addition, the presence of anomalies was verified through the comparison study between the detection results and the representative circadian cycle of the color temperature by solar term. The judgment method for the anomalies from the measured color temperature of natural light was proposed for the first time, confirming that the proposed method was capable of detecting the anomalies with an average accuracy of 94.6%.

The study of habitat characteristics and food sources of Luciola unmunsana - A Case Study of Sansungcheon, Jeonju City - (운문산반딧불이(Luciola unmunsana)의 서식지 특성과 먹이원에 관한 연구 - 전주시 산성천을 대상으로 -)

  • Lim, Hyun-Jeong;Kim, Jong-Man;Jeong, Moon-Sun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.25 no.3
    • /
    • pp.83-95
    • /
    • 2022
  • This study aims to present primary data for habitat restoration and artificial breeding conditions of L. unmunsana by identifying the habitat conditions and the larvae's food sources. In order to investigate the habitat characteristics of the adult L. unmunsana and land snails, which are the primary food sources for the larvae, field surveys were conducted on a total of 10 habitats in south-central parts of Korea including Sanseongcheon, Jeonju. The results revealed that the L. unmunsana habitat in the Sanseongcheon area had a broadleaf forest with a multi-layered vegetation structure, adjacent water features, and the north/northeast/northwest slopes with little effect of artificial lighting. The adult L. unmunsana in the Sanseongcheon area appeared from the end of May to the end of June, and was especially intensively observed around the middle of June. The most active time was from 23:30 to 00:30 with a temperature range of 19~22℃ and higher than 80% humidity. The peak count of the observed adults L. unmunsana was a total of 774 on June 11, 2021. In the case of land snails, 11 families and 23 species were observed in 10 habitats of L. unmunsana, and Euphaedusa fusaniana was the most extensive and the most observed in the five survey areas. The land snails of L. unmunsana habitats are mostly found under the organic layers of leaves and a fallen tree branch in broadleaf forests, where a thick organic material layer buffers temperature changes and provides high humidity for various snails. These habitat conditions are suitable for the larva of L. unmunsana and land snails to inhabit, feed, hide and hibernate.