• Title/Summary/Keyword: Urban air quality

Search Result 388, Processing Time 0.027 seconds

An Experimental Study on Improvement of Exhaust Gas Testing Method of Light-Duty Diesel Engine (소형디젤승합차의 배출가스 검사방법 개선에 관한 실험적 연구)

  • 한영출;나완용;오용석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.4
    • /
    • pp.56-61
    • /
    • 2001
  • In recent years, the environmental demage to urban area becomes serious problem due to the exhaust emissions by increasing the number of vehicle. The proportion of diesel vehicle is very high in this country. Exhaust gas emitted from the diesel-powered vehicle is severly affecting to the air quality. In this study, light-duty diesel engine was studied on the improvement of exhaust gas testing method. Therefore the results obtained effective load method among testing method. It is deserve to test of the PM for the environment.

  • PDF

A Study on the Cooling Load Generation for Efficient Energy Management (냉방부하 수요 창출을 통한 효율적 에너지 관리방안 연구)

  • Woo, Nam-Sub;Kim, Yong-Ki;Lee, Tae-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1007-1012
    • /
    • 2008
  • Demand for the highly efficient and high performance urban energy supply system having been continuously increased according to the rise of quality of life and continuously increased energy cost all over the world. The district heating and cooling system is very effective way for energy saving, cost reduction, and demand side management of energy. There are several district cooling supply technologies such as chilled water direct transportation, installation of absorption type chiller in the user side, and desiccant cooling. This study investigates the advantage and technical problems of each district cooling technology. Also, it is necessary political and financial support system for the extension of district cooling system.

  • PDF

Porous Photocatalytic Concrete Filter Manufacturing and Efficiency Evaluation for NOx Reduction (NOx 저감을 위한 다공성 광촉매 콘크리트 필터 제조 및 효율평가)

  • Kim, Jong Kyu
    • Korean Journal of Materials Research
    • /
    • v.32 no.4
    • /
    • pp.223-229
    • /
    • 2022
  • A porous photocatalyst concrete filter was successfully produced to remove NOx, by mixing TiO2 photocatalyst with lightweight aerated concrete. Ultra Fine Bubbles were used to form continuous pores inside the porous photocatalytic concrete filter, which was mixed via a bubble generation experiment. The optimal mixing condition was determined to be with 4 % of the bubble generation agent B. NO removal specimens were prepared for various photocatalytic loading conditions, and the specimen containing 3 % P-25 removed NO at a concentration of 1.03 µmol in 1 h. The NO removal rate of the porous photocatalytic concrete filter prepared in this study was 10.99 %. This photocatalytic filter performance was more than 9 times the amount of NO removed by a general photocatalytic filter. The porous photocatalyst concrete filter for removing NOx developed in this study can be applied to various construction sites and the air quality can be solved by reducing NOx contributing to the formation of fine particles.

Characteristics of Fog and Mist Observed in the Rural Area of Chongju and Chongwon (청주-청원 지역에서 관측한 안개와 박무의 특성 연구)

  • 윤마병;정용승
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.15-21
    • /
    • 1996
  • Daily measutements of visibility on 09 LST have been made at a rural site in Chong-won, Chong-book since 1991 to find out a possible influence of emissions of anthropogenic pollutants and water vapout in urban and rural environments. Daily visibility data collected over four-year period were compared with the available visibility and air quality data obtainde from other stations. Detailed examinations of our data showed that the frequency of fog occurrence (visibility .leq. 1 km) at a rural site (KNUE) was at least three times higher (77 days per year) than the frequency of fog both in Chong-ju city (19 days) and at the Air Force Base(AFB) in the rural area. We interpret that the higher frequency of fog at KNUE was due to abundant water vapour in the Mieho River (upstream of the Keum River) area. In Chong-ju city, fog usually continued for a relatively long duration, while it dissipated simewhat faster in the rural environment due to higher solar radiation in the countryside area. The number of misty (.leg. 6 km) days (including foggy days) at KNUE were 235 days as compared with 135 days at the AFB and 67 days in Chong-ju city. In turn the number of days with low visibility (less than 6 km) at KNUE was about 64% per year. Since the moisture alone in a calm morning does not produce a visibility impairment, there must had abundant condensation nuclei including anthropogenic air pollutants. Air pollution was examined, for instance, average values of TSP for November and December 1993 were 115 and 116.mu.g/m$^{3}$, respectively. We conclude that the above mentioned environmental conditions with moisture are favourable for the formation of fog and mist in the rural sampling site at KNUE. Additionally, we found at least 10 days of acid fog at KNUE in September 1994 alone. Measured pH values in the acid for water were in the range of 4.36 .sim. 5.01 with the mean value of 4.51 Our observations suggested that strikingly acid fog do occur occasionally even in the rural environment.

  • PDF

Evaluation of Particulate Matter Removal Rate according to Filter Type and Thickness of Total Heat Exchanger in Apartment Houses (공동주택 전열교환기 필터종류 및 두께에 따른 미세먼지 제거율 평가)

  • Song, Yong-Woo
    • Land and Housing Review
    • /
    • v.11 no.4
    • /
    • pp.93-98
    • /
    • 2020
  • This study examined the particulate removal performance of three different types of air filters inside a heat exchanger. Of interest was the ability of each filter type in reducing the transmission of outdoor particulate matter of PM10 from entering an apartment while the heat exchanger was in operation. The study tested one commonly used medium filter (E11 grade) and two HEPA filters (H13 grade) of different thicknesses. Two different concentrations of particulate matter were used in the experiment to address different ambient air quality conditions in Korea, 32.75 ㎍/㎥ and 67.26 ㎍/㎥. Study results indicated that under the particulate matter concentration of 32.75 ㎍/㎥, all three filters were capable of removing more than 95% of the fine dust. However at a particulate matter concentration of 67.26 ㎍/㎥, the medium E11 grade filter was only able to remove about 90% of the particulates whereas the HEPA H13 grade filters were able to remove 95% or more of the particulates. The thicker HEPA filter (40T) was also more effective in removing particulates than the thinner HEPA filter (20T) by about 1.6 to 3 percentage points. Based on the findings of this study, it is recommended that HEPA filters of 20T thickness or greater be used during the high air pollution seasons of winter and spring in Korea while medium filters can be used during the other seasons to reduce outdoor air pollution transmission indoors.

Remote Sensing of Atmospheric Trace Species using Multi Axis Differential Optical Absorption Spectroscopy (Multi Axis DOAS를 이용한 대기미량 물질 원격 측정)

  • Lee Chul-Kyu;Kim Young-Joon
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.2
    • /
    • pp.141-151
    • /
    • 2006
  • UV-visible absorption measurement techniques using several horizone viewing directions in addition to the traditional zenith-sky pointing have been recently developed in ground-based remote sensing of atmospheric constituents. The spatial distribution of various trace gases close to the instrument can be derived by combing several viewing directions. Multi-axis differential optical absorption spectroscopy (MAX-DOAS) technique, one of the remote sensing techniques for air quality measurements, uses the scattered sunlight as a light source and measures it at various elevation angles (corresponding to the viewing directions) by sequential scanning with a stepper motor. A MAX-DOAS system developed by GIST/ADEMRC has been applied to measuring trace gases in urban air and plumes of the volcano and fossil fuel power plant in January, May, and October 2004, respectively. MAX-DOAS spectra were analyzed to identify and quantify $SO_2,\;NO_2,\;BrO,\;and\;O_4$ (based on Slant Column Densities, SCD) in the urban air, volcanic plume, and fossil fuel power plant utilizing theirs specific structured absorption features in the UV-visible region. Vertical scan through the multiple elevation angles was performed at different directions perpendicular to the plume dispersion to retrieve cross-sectional distribution of $SO_2\;or\;NO_2$ in the plumes of the volcano and fossil fuel power plant. Based on the estimated cross sections of the plumes the mixing ratios were estimated to 580 $SO_2$ ppbv in the volcanic Plume, and 337 $NO_2\;and\;227\;SO_2$ ppbv in the plume of the fossil fuel power plant, respectively.

Estimating Environmental Carrying Capacity of Seoul Metropolitan Area Using System Dynamics and Box Model

  • Moon, Taehoon
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.10a
    • /
    • pp.20-36
    • /
    • 2001
  • The purpose of this paper is estimating environmental carving capacity of Seoul Metropolitan Area for a sustainable city management using system dynamics model. A sustainable development requires a society to define sustainability constraints or environmental limits, environmental carving capacity. Environmental carving capacity can be defined as the level of human activity which a region can sustain at an acceptable quality of life level. This concept of environmental carving capacity has several important application to sustainable city planning and management. If the limitation of a human activity can be supported by a scientific data on carving capacity, the resulting decision and actions could more easily win public support for a sustainable development. However, one of the key issues is how to operationalize the carving capacity. In this paper, the environmental carving capacity was operationalized as a maximum number of industry structure, population, and housing that can sustain certain level of environmental quality of Seoul Metropolitan Area. The model developed in this paper consisted off sectors: population, housing, industry, land, and environmental sector. The model limits its main focus on the NO$_2$level of ambient air of Seoul. Carving capacity Seoul Metropolitan Area was estimated by figuring out the maximum number of population, industry structure, housing at an equilibrium point that sustain a desirable NO$_2$level. Based on the model estimation, several policy implications for a sustainable city management was discussed.

  • PDF

Observed Characteristics of Precipitation Timing during the Severe Hazes: Implication to Aerosol-Precipitation Interactions (연무 종류별 강수 발생시간 관측 특성 및 에어로졸-강수 연관성 분석)

  • Eun, Seung-Hee;Zhang, Wenting;Park, Sung-Min;Kim, Byung-Gon;Park, Jin-Soo;Kim, Jeong-Soo;Park, Il-Soo
    • Atmosphere
    • /
    • v.28 no.2
    • /
    • pp.175-185
    • /
    • 2018
  • Characteristics of precipitation response to enhanced aerosols have been investigated during the severe haze events observed in Korea for 2011 to 2016. All 6-years haze events are classified into long-range transported haze (LH: 31%), urban haze (UH: 28%), and yellow sand (YS: 18%) in order. Long-range transported one is mainly discussed in this study. Interestingly, both LH (68%) and YS (87%) appear to be more frequently accompanied with precipitation than UH (48%). We also found out the different timing of precipitation for LH and YS, respectively. The variations of precipitation frequency for the LH event tend to coincide with aerosol variations specifically in terms of temporal covariation, which is in contrast with YS. Increased aerosol loadings following precipitation for the YS event seems to be primarily controlled by large scale synoptic forcing. Meanwhile, aerosols for the LH event may be closely associated with precipitation longevity through changes in cloud microphysics such that enhanced aerosols can increase smaller cloud droplets and further extend light precipitation at weaker rate. Notably, precipitation persisted longer than operational weather forecast not considering detailed aerosol-cloud interactions, but the timescale was limited within a day. This result demonstrates active interactions between aerosols and meteorology such as probable modifications of cloud microphysics and precipitation, synoptic-induced dust transport, and precipitation-scavenging in Korea. Understanding of aerosol potential effect on precipitation will contribute to improving the performance of numerical weather model especially in terms of precipitation timing and location.

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

Measurement of VOCs Concentrations at Jeonju Industrial Area and Emission Characteristics (전주공단지역의 주요VOCs 배출농도 측정 및 배출원별 특성 분석)

  • Kim, Deug-Soo;Yang, Go-Soo;Park, Bi-O
    • Journal of Environmental Science International
    • /
    • v.16 no.3
    • /
    • pp.299-310
    • /
    • 2007
  • It will be necessary to make proper management plans to preserve the air quality in good level for the public. In order to make these plans, source information and detail emission inventories of the city and near industrial areas should be given. However, lack of the source measurements data makes us more difficult to complete the source inventory. VOC source Inventory could be utilized for the feasibility study to estimate the contribution of VOC sources presenting to the receptor such as residential area. It may give policy maker an idea how to control the air quality, and improve their social environment in the area. This study shows data that measured VOCs concentrations from the local industrial areas in Jeonju during from May 2005 to January 2006. The samples were collected from the near sources in 7 major factories in the industrial park as well as 5 general sources in near city Jeonju area to elucidate the abundances of speciated VOCs and their spacial and temporal distributions depending on source bases. Industrial sources are as follows; chemical, food, paper, wood, metal, non-metal (glass), and painting (coating) industries. The 5 general sources are sampled from tunnel, gasoline gas station, dry cleaning shop, printing (copy) shop, and road pavement working place in urban area. To understand the near source effect at receptor, samples from the 2 receptor sites (one is at center of the industrial complex and the other site is at distance residential area downwind from the center) were collected and analyzed for the comparison to source concentration. The mass contributions of the speciated VOC to total mass of VOCs measured from the different sources and ambient (2 receptors) were presented and discussed.