• 제목/요약/키워드: Urban Integrated Energy System

검색결과 52건 처리시간 0.026초

국내 여름철 기후조건에서 DOAS와 TABS 통합시스템 냉방운전시 실내온열환경 및 운전특성 평가 (Evaluation on the Indoor Thermal Environment and Cooling Operation Characteristics of Thermally Activated Building System integrated with Dedicated Outdoor Air System during Cooling Operation in Hot and Humid Climate of Seoul)

  • 이윤선;이겨레;정웅준;임재한
    • 대한건축학회논문집:계획계
    • /
    • 제34권11호
    • /
    • pp.45-55
    • /
    • 2018
  • To reduce the energy consumption of HVAC system in buildings, thermally activated building system(TABS) has been applied to low energy building because of energy efficient performance and reduction of peak load. DOAS coupled with a parallel sensible cooling could be promising because TABS handles sensible heat load only. The purpose of this study was to evaluate the indoor thermal environment and cooling operation characteristic of TABS with dedicated outdoor air system(DOAS) in Korea climate. Indoor thermal environment and operation characteristic of TABS integrated with DOAS are investigated at different TABS operation schedules and climate conditions by simulation tests. The result shows that the DOAS is more suitable for hot and humid climates. And also it show that the potential of intermittent operation of TABS.

공동주택의 태양광발전 시스템 적용을 위한 설계방법에 관한 연구 (A Study on the Design Methods of PV System for Apartment Building Application)

  • 이소미;이용호
    • 신재생에너지
    • /
    • 제4권4호
    • /
    • pp.10-16
    • /
    • 2008
  • Nowaday, The Sustainable Development about global environment is the most important subject. In urban environment, a variety of the nature energy utilization such as the solar energy are the most efficient solution to solve this issue. One of these efficient solutions, a photovoltaic system using sunlight has been introduced to the building with an advantage such as cost-effective, safe for using and good for environment friendly in light with energy utilization. Recently, many of the apartment housings are built in domestic country. The apartment buildings have been constructed since early of 1970's. now apartment is taking over 50% out of entire housing in korea. The apartment housing applying to a photovoltaic system has been extensively studied in the foreign country but our county runs short. So, It was necessary to technical development of PV application which is suitable in Korean house culture. The objective of this study is to develop the building integrated PV application method for apartment building.

  • PDF

건물 지붕 구조를 활용한 건물일체형 풍력발전시스템의 성능 예측 (Pitched Roof-Building Integrated Wind Turbine System Performance Estimation)

  • 최형식;장호남
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.324-327
    • /
    • 2008
  • We simulated the performance improvement of a wind turbine installed on the pitched roof-building(apartment in urban area, 50m height). A nozzle shape wind guide is added on the roof of a model apartment. The nozzle-diifuser structure effects for the free stream wind (average 4m/s, 50m height in Incheon) is studied by a basic CFD analysis. This paper examines the effects of roof structure on the wind velocity and the wind distortion effects by a front building. The possible wind power generation capacity on building roof in urban is calculated.

  • PDF

차세대에너지시스템 구축을 위한 도시기상조건 시계열분석 (A Time Series Analysis on Urban Weather Conditions for Constructing Urban Integrated Energy System)

  • 김상옥;한경민;이정재;윤성환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.26-31
    • /
    • 2009
  • This study was analysed influence of urban higher temperature in Busan about time series analysis of AWS data. The results are as follows. (1) The temperature of Busan show min $13.2^{\circ}C$ ~max $15.8^{\circ}C$ by 50 years, it is on the rise. (2) The seasonal adjustment series, summer appeared min $17.5^{\circ}C$ ~max $28.9^{\circ}C$ with primitive series similarly. The winter was min $-11.4^{\circ}C$ ~max $17.9^{\circ}C$, the minimum temperature was more lowly than primitive series and maximum temperature was more higher than primitive series. The results, seasonal adjustment series is guessed with influence difference urban structural element beside seasonal factor. (3) Regional analytical result, January appeared with range of min 28% ~max 196% of the seasonal factor and August appeared min 90% ~ max 106%. One of the case which is of 100% or more of the seasonal factor January 12nd~17th, August appears at the 15~17th.

  • PDF

공동주택의 태양광발전설비 적용을 위한 설계방법에 관한 연구 (Study on the Design Methods of PV System for Apartment Buildings Application)

  • 이소미;윤철;이용호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.98-101
    • /
    • 2008
  • Nowaday, The Sustainable Development about global environment is the most important subject. In urban environment, a variety of the nature energy utilization such as the solar energy are the most efficient solution to solve this issue. One of these efficient solutions, a photovoltaic system using sunlight has been introduced to the building with an advantage such as cost-effective, safe for using and good for environment friendly in light with energy utilization. Recently, many of the apartment housings are built in domestic country. The apartment buildings have been constructed since early of 1970's. now apartment is taking over 50% out of entire housing in korea. The apartment housing applying to a photovoltaic system has been extensively studied in the foreign country but our county runs short. So, It was necessary to technical development of PV application which is suitable in Korean house culture. The objective of this study is to develop the building integrated PV application method for apartment building.

  • PDF

건물 사이에 풍력발전기를 설치하기 위한 기류특성분석 (Analysis of Air Current Characteristics for Installing Wind Turbines Between Buildings)

  • 박민우;유장열;손영무;유기표
    • 한국공간구조학회논문집
    • /
    • 제18권1호
    • /
    • pp.117-125
    • /
    • 2018
  • Recently, various building integrated wind power (BIWP) approaches have been used to produce energy by installing wind power generators in high-rise buildings constructed in urban areas. BIWP has advantages in that it does not require support to position the turbine up to the installation height, and the energy produced by the wind turbine can be applied directly to the building. The accurate evaluation of wind speed is important in urban wind power generation. In this study, a wind tunnel test and computational fluid dynamics (CFD) analysis were conducted to evaluate the wind speed for installing wind turbines between buildings. The analysis results showed that the longer the length of the buildings, which had the same height, the larger the wind speed between the two buildings. Furthermore, the narrower the building's width, the higher the wind velocity; these outcomes are due to the increase in the Venturi effect. In addition, the correlation coefficient between the results of the wind tunnel test and the CFD analysis was higher than 0.8, which is a very high value.

국가 건물에너지통합관리시스템의 데이터 품질 분석 및 개선방안 연구 (A Study on the Analysis and Methods to Improve the Management System for Building Energy Database)

  • 김성민;윤종돈;권오인;신성은
    • 에너지공학
    • /
    • 제25권1호
    • /
    • pp.131-144
    • /
    • 2016
  • 최근 기후변화로 인해 전 세계적인 지구온난화 피해가 심각해지면서 주요원인인 온실가스에 대한 배출 규제가 확대되고 있다. 그 중 온실가스 배출량의 약 25%를 차지하는 건물분야에 대해 정부에서는 2020년까지 BAU 대비 26.9%까지 감축하겠다는 목표를 발표하였다. 이를 달성하기 위해 건물부문의 에너지 수요를 원천적으로 저감하는 녹색건축물 활성화 방안을 추진하고 있다. 하지만 녹색건축물 활성화의 상세 이행계획 수립 및 관리, 그리고 시행에 따른 효과를 분석하기 위해서는 건물 에너지 사용량에 대한 데이터 및 관련 통계 자료가 필수적이다. 이를 위해 정부는 전국 680만동의 건물에서 사용되는 에너지 정보를 통합 관리할 수 있는 국가 건물에너지 통합관리시스템을 구축하였다. 하지만 현재 구축된 국가 건물에너지 통합관리시스템의 Database는 건축물대장 정보와 공급기관의 에너지정보를 매칭해서 사용하기 때문에 수동으로 작업이 이루어지고 있으며, 이로 인해 많은 문제들이 발생한다. 따라서 Database의 신뢰성을 확보하기 위해서는 지속적인 고도화 작업이 이루어져야 한다. 본 과제는 현재 가동 중인 국가 건물에너지 통합관리시스템의 Database를 분석하여, 시스템의 한계 및 개선방안 도출하고, 이를 통해 데이터의 신뢰성 확보 및 활용성을 증대 시키고자 하였다. 구축된 Database 분석 결과 건축물 정보와 에너지정보가 매칭된 유효데이터는 평균 85.6%이고, 미매칭된 데이터는 평균 14.4%로 나타났다. 미매칭된 데이터는 다시 건물 특성에 따른 미매칭 유형을 분석하였으며, 그 결과 건축물 정보가 없는 경우가 전체의 58.2%에 달했다. 따라서 향후 신규 구축 data의 매칭 작업 용이성 및 현재 Database에 대한 정확성 확보하기 위해서는 건축물 정보와 에너지정보 간의 주소 표준화 및 속성정보 체계를 마련할 필요가 있다. 또한 비도시지역 및 영세한 주거지역에서 사용비중이 높은 석유류 에너지원 및 향후 발전 가능성 및 활용 가능성이 높은 신재생 에너지와 같이 다른 에너지원에 대한 정보를 포함시킬 수 있도록 시스템 구축이 필요할 것으로 사료된다.

상하수도시설에 대한 전과정관리(LCM)시스템 구축방안 연구 (Establishment of Life Cycle Management(LCM) System for Water Supply and Sewerage Systems)

  • 박지형;황용우;김영운;박광호
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.303-312
    • /
    • 2012
  • Water supply and sewerage systems are the large-scale urban infrastructure ejecting large amount of environmental load over the life-cycle. Therefore, it is important not only to optimize in the aspect of economical superiority and process efficiency but also to consider earth scale environmental impact. This study aimed to suggest the establishment of life cycle management(LCM) system as an integrated management solution in urban water supply and sewerage systems. As a result, the methodology for LCM system consisting of life cycle assessment(LCA), life cycle cost(LCC), life cycle $CO_{2}(LCCO_{2})$ and life cycle energy(LCE) was developed. Also, several case studies using the latest statistics data of water supply and sewerage systems were carried out to investigate the field applicability of LCM.

Mock-up실험을 통한 BIPV Module의 외벽 성능평가 (A Experimental Study on Finished Envelope Performance of BIPV Module)

  • 이소미;윤철;이용호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.251-256
    • /
    • 2008
  • Nowaday, The Sustainable Development about global environment is the most important subject. In urban environment, a variety of the nature energy utilization such as the solar energy are the most efficient solution to solve this issue. One of these efficient solutions, a photovoltaic system using sunlight has been introduced to the building with an advantage such as cost-effective, safe for using and good for environment friendly in light with energy utilization. The BIPV is one of the most interesting and promisingly possibilities of an active use of solar energy at the building. Therefore the goal of this study is to get securing the application information of BIPV as finished envelope. The purpose of this study is to investigate the current performance measurement methods of BIPV module and to measure the performance of BIPV module by mock-up tests.

  • PDF

지하도 상가 냉난방.환기 시스템의 난방운전 특성 연구 (An Experimental Study on the Heating Characteristics of HVAC Systems for Shopping Center in Underground Passage)

  • 이홍철;황인주;김태형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2989-2994
    • /
    • 2008
  • The shopping center in underground passage for efficient space utilization is increased in urban area. This study describes operation characteristics of HVAC systems with ventilation and individual heating and cooling unit for shopping center in underground passage. In order to compare energy saving, thermal environment and installation space, etc., an integrated simulator with heat production and distribution system was designed and constructed. Energy delivery efficiency is improved over 20%, and energy saving of the hybrid system is calculated as over 30% compared to conventional all air type in the case of heating. And also the results showed that humidity decreased about $5{\sim}6%$, also characteristics of thermal control is improved over 34%.

  • PDF