• 제목/요약/키워드: Urban Integrated Energy System

검색결과 52건 처리시간 0.027초

차세대에너지시스템 구축을 위한 친환경 도시계획 시나리오 검토 (An Analysis of Examination of Eco-City Planning Scenario for Constructing Urban Integrated Energy System)

  • 여인애;이정재;윤성환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.181-184
    • /
    • 2009
  • This study aimed at framing alternative urban planning scenarios reflecting urban planning factors, performing urban climate simulation and evaluating eco-friend and low energy characteristics of each scenario on the viewpoint of urban temperature and energy savings on the target of the costal city including Haeundae District in Busan The results are as follows. 1)The fact that urban higher temperature is approximately 2.5 times higher in the building constructed area than whole urban area was represented severe higher temperature phenomenon in the built-up area. Ground greening, water scenario and soil scenario could be expected peek air temperature alleviating effect in order. Especially water scenario had significant effect(maximum $2.5^{\circ}C$) on lowering of air temperature.

  • PDF

에너지공급시설 및 환경기초시설의 복합화 방안 및 적용효과 분석 (A Study on the Design Method and the Effect Analysis for the Introduction of the Integrated System Model of Individual Urban Utility Plants)

  • 이태원;김용기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.235-240
    • /
    • 2005
  • Recently urban utility plants in urban areas of Korea, such as energy supply systems, municipal waste incineration systems, sewage treatment systems and so on, have caused some critical troubles, for instance the insensitive response to the seasonal or daily variation of loads, the low system efficiency and inefficient use of energy because of the large-scale system located a great distance. Therefor the design method of optimal integrated system model of various urban utility plants proposed in this study suitably to the present situation of Korea. Also, the effect analysis for the introduction of compound utility plants was studied for a new town model on a 60,000 persons scale. As the results we found that the complex plant was superior to individual urban utility plant in side of the initial investment expenses, the operating cost and other reasons.

  • PDF

태양광발전 도시 프로젝트의 개발현황과 발전방향 고찰 (A Study on The development status and future of Photovoltaic Urban Project)

  • 김현일;서승직;박경은;강기환;유권종
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.87-92
    • /
    • 2008
  • Buildings are responsible for approximately 50% of current carbon dioxide emissions. Energy planning at a town and city scale needs a strategic approach, supported by strong planning policies. The purpose of this study was to investigate the urban scale grid-connected photovoltaic(PV) system for urban residential and commercial sector applications. The integration of PV technology into roof of houses is an approach that is being championed in Germany, Japan and United states etc. In the Korea, PV roofing systems already are given the large number of houses which are projected to be built by 2012. However unlike germany and Japan, urban scale grid-connected PV system is not yet installed. The solar city which is installed building-integrated photovoltaic system is available to use of renewable energy sources such as solar to meet demand, instead of fossil fuels, with the goal of realizing an ecologically oriented energy supply.

철도 변전소 공유를 통한 직류 도시철도 시스템 회생에너지 이용률 향상 방안 연구 (A Study of Improving Regenerative Energy Utilization in Urban DC Railway Systems Through Sharing Substations)

  • 정승민;이한상;변길성;권세혁;장길수;정호성;김형철
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2392-2396
    • /
    • 2011
  • This paper deals with the power integration of large urban railway systems to improve regenerative energy utilization. Current regenerative energy utilization is low because there is no special plan for using this energy. If the railway system is integrated with other railway systems, the efficiency is expected to be improved. Through the case studies, to find the realistic effect of integrated operation, real system for the Seoul Metro lines, especially line 5 and 7, had been applied.

도시차원에서의 에너지 적용에 따른 문제점 및 체계 검토 (Investigation of Problem and System by Energy Application in City Level)

  • 박률;김삼열;박진영;이상진;이정재
    • 한국태양에너지학회 논문집
    • /
    • 제29권3호
    • /
    • pp.51-58
    • /
    • 2009
  • Recently, many social, economical and political problems have occurred in the field of urban energy supply because of the depletion of fossil fuels and the international climate change agreements and the current energy-related laws focus on individual buildings which makes them difficult to implement. Also, the policies for energy savings have increased day by day, but it is difficult to establish efficient urban plan because of lack of integrated policies and institutions. Current legal systems for urban plan does not cover domestic and international climate change agreements, energy related industry's structural changes and other environmental problems such as embodied energy and global warming. This paper tries to investigate current conditions of legal system to provide fundamental materials for improving energy conservation in urban plan.

A Study on Peak Power Reduction using Regenerative Energy in Railway Systems through DC Subsystem Interconnection

  • Jung, Seungmin;Lee, Hansang;Kim, Kisuk;Jung, Hosung;Kim, Hyungchul;Jang, Gilsoo
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1070-1077
    • /
    • 2013
  • Owing to the consistent increase in energy efficiency issues, studies for improving regenerative energy utilization have been receiving attention in the Urban DC railway systems, where currently, the utilization of regenerative energy is low due to the lack of a specific plan for using this energy. The regenerative energy in railway systems has a low efficiency problem which results in the increase of the catenary voltage and a possibility to create problems to the electrical devices connected to the system. This paper deals with the power integration of large urban railway subsystems to improve regenerative energy utilization where the railway subsystems are integrated with other railway subsystems to improve the energy efficiency. Through the case studies, to find the realistic effect of integrated operation, the Seoul Metro subsystems, namely Line 5 and Line 7, has been applied. Also, evaluation for the electricity cost saving has been performed by using KEPCO electricity cost table.

탄소저감 도시계획 시스템의 통합화 방안 도출 연구 (A study on Integrating Strategy of Low-carbon Urban Planning System)

  • 박찬호;김범석
    • Spatial Information Research
    • /
    • 제21권2호
    • /
    • pp.99-106
    • /
    • 2013
  • 현대사회가 산업화 되고 고도성장을 이룩하며 자연환경이 훼손됨에 따라 기후변화 대응 및 저탄소 녹색성장을 위한 도시차원의 구체적인 실천대안의 필요성이 증대되고 있다. 국내에서 많은 저탄소도시 및 녹색도시 관련 연구가 진행 중에 있으나 대부분의 관련 연구들에서는 저탄소도시 혹은 녹색도시 구축을 위한 연구를 진행함에 있어 건축, 교통, 에너지 등 각 분야별로 연구를 진행하고 있기에 각 분야별 연구 결과들이 통합적으로 이용되지 않고 있다. 본 논문에서는 이러한 문제점을 해결하기 위하여 저탄소도시 혹은 녹색도시를 위한 시스템을 구축하는 관련 연구들의 현황을 조사하고, 각 분야별로 도출된 결과물을 통합적으로 이용할 수 있는 방안을 정의하고자 한다. 논문에서 정의된 '탄소저감 도시계획 통합시스템'의 통합 모델로서 각 개별 시스템을 분석 시 데이터 로드 등에 대한 문제로 인하여 C/S 시스템으로 개발하고, 통합 시스템에 분석된 DB를 조회/활용할 수 있도록 개발하며, 통합 시스템은 Web으로 개발하는 방향으로 결정하였다. 본 연구 결과를 바탕으로 차후 연구개발 사업들에서는 경제적이고 효율적인 통합 모델이 도출될 수 있을 것이며, 현장에서 실제로 각 개발 성과물들이 활용될 수 있을 것이다.

도시단위 건축물 CO2 저감을 위한 데이터 통합 활용 기반기술에 관한 연구 (A Study on Integrated Utilization of Urban Spatial Data and Building Data for CO2 Reduction)

  • 최혜미;박창한;김주형;김재준
    • 한국BIM학회 논문집
    • /
    • 제5권3호
    • /
    • pp.1-10
    • /
    • 2015
  • We have researched a character of BIM(Building Information Modeling) and GIS(Geographic Information System) data for integrated utilization of urban spatial data and building data for $CO_2$ reduction. We consider literature on integrated utilization of BIM and GIS and measure method of $CO_2$ in urban spatial unit. Among them without distortion of standard data structure, derive method how to install between BIM and GIS standard data. Rhino & Grasshopper is utilization tools of DB platform. The compatibility with existing BIM and GIS data format, graphic and numeric results can be output at the same time. And using the existing ARCHSIM, it can be easily combined for building energy analysis program. Based on BIM and GIS data to run an energy analysis target on Majang-dong, it could be poly synthetically derived the value information and graphic information.

발코니형 BIPV시스템의 성능 분석 (Performance Analysis of Balcony BIPV System)

  • 김현일;강기환;소정훈;유권종;박경은;이길송;서승직
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.208-209
    • /
    • 2007
  • Photovoltaic(PV) based electricity production is pollution-free at the local as well as the global level, it does not emit greenhouse gases, it dose not dip into finite file resources and it can be easily integrated into the urban environment, close to major consumption needs. So BIPV(Building-Integrated Photovoltaics) system have been increased around the world. This paper presents measuring and analyzing performance of balcony BIPV system which have been installed and monitoring. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. By the results, it is very important to develop optimal design for the balcony PV system.

  • PDF

연료전지 연계 수소추출기 통합 시스템에 대한 위험성 평가 (Risk Assessment for the Integrated System of Hydrogen Generation System Linked to Fuel Cell)

  • 신단비;홍성철;이광원;서두현;이동민;김태훈
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.728-733
    • /
    • 2023
  • Efforts are continuing to change from fossil fuels used to hydrogen energy society. In order to become a hydrogen society, stable production and real-life applicability are important. As a result, hydrogen generation system linked to fuel cell are being developed. Through this, it is expected that production to power generation will be possible where desired by utilizing the existing urban gas piping network. Hydrogen generation system and hydrogen fuel cell have been subjected to risk assessment and have already been commercialized, but no risk assessment has been conducted on the integrated system linking them. Therefore, it is intended to secure its safety by conducting a risk analysis on the integrated system.