• Title/Summary/Keyword: Urban Elements

Search Result 887, Processing Time 0.038 seconds

Energy Consumption Characteristics and Policy Directions According to Apartment Complex Type in Incheon Metropolitan City (초고층과 일반 아파트 단지의 에너지 소비 특성과 정책방향 연구 - 인천지역 아파트 단지의 전기 및 가스 사용량을 중심으로)

  • Rhee, Bum-Hun;Chang, Dong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.285-290
    • /
    • 2019
  • This study aims to compare the energy consumption characteristics of high-rise and general apartments and propose policy implications in Incheon City where high-rise apartments are planned. The method of analysis is to select the cases, to conduct field survey, drawing review, analysis of Electric Architectural administration Information System. The study derived the current status of energy consumption in high-rise and general apartment complexes located in the same region, Yeonsu-gu Incheon City, and performed comparative analysis on their characteristics. First, electrical energy in the high-rise apartment complexes was consumed excessively, by 1.63 to 2.5 times more than that of the general apartment complexes. Second, the gas energy usage in the high-rise apartment complexes was higher than that of the general complexes, by 1.09 to 1.2 times. Third, the energy consumption per unit area in the high-rises was also higher, by 1.042 to 1.3 times. As individual elements such as incomes, living standards, and life patterns of the residents affect energy consumption, the high-rise apartment complex consumed more energy per unit area than the general apartment complex did. However, this study did not consider the elements of energy expenditure and satisfaction level, which are the limitations of this research.

A Study on the Development of Storytelling for Culture and Tourism Market Development - Based on Jecheon Central Market (문화관광형시장 육성을 위한 스토리텔링개발연구 - 제천중앙시장을 중심으로)

  • Park, Jin-Soo
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.6
    • /
    • pp.367-374
    • /
    • 2018
  • The purpose of this research is to promote traditional markets, which are part of urban regeneration project, and to promote cultural and tourism market by applying characteristics and differentiated elements through story development through market-related resources in order to secure identity of the JeCheon Central market that lost function of the traditional market and regional aging of the traditional market. To this end, the basic survey and analysis of the Jecheon area and the current situation of the Jecheon Central Market were conducted to diagnose problems and to analyze keywords through surveys by local merchants and visitors. By drawing up measures to vitalize the Jecheon Central Market by floor and space, the Jecheon Central Market's design story is developed and applied so that it can restore the image of the local traditional market through regional and cultural elements and become a center of space and culture that can become a landmark for the region in the future. The storytelling designed for this purpose shall be linked to the spatial planning of each floor as well as the C.I. and exterior of the C.I. and the building of the Jecheon Central Market, and the identity of the Jecheon Central Market can be reestablishe.

The Characteristics of Flexibility applied to Unit Plan of Housing by Residents Participation - focusing on European Multi-story Housing applying Residents Participation - (거주자 참여형 공동주거의 평면계획에 적용된 가변성의 특성 - 유럽의 거주자 참여형 다층 공동주거를 중심으로 -)

  • Kim, Hyun-Ju
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.113-123
    • /
    • 2018
  • First of all, the multi-story Housing applying resident's participation in europe was classified by the menu selection method, the two-step supply method and the cooperative method. And then I analyzed flexible unit plan of cases for deriving the planning methode and the characteristics of flexibility. First, I analyzed the area and form of the unit plan, structure and Installation, fixed and variable elements to derive the planning method. The area of units are distributed from a minimum of $35m^2$ to a maximum of $150m^2$, and many of the unit planes have a narrow front and a deep depth. The structure is a long-span wall-structure or a skeleton structure, and is designed without any columns and bearing walls in the interior space for flexibility in spatial composition. The vertical shafts are located in the center of the unit in a box-form or in the corner at the unit dividing wall for free placement of interior wall. Fixed elements are framework and facility systems. Most of the future residents in the two-steps supply method and the cooperative method were able to freely design the internal space within the zoning concept proposed by the architect and change the location of the facade element within module system proposed by the architect. Second, the characteristics of the flexibility applied to the unit plan were divided in integrated flexibility, functional flexibility, construction flexibility, and supply flexibility. The integrated flexibility enables residents to give the variable space combination based on the complex structure of the inner space for providing various living experiences. Regarding functional flexibility, the three-dimensional spatial structure with neutral space has multi-functionality according to the needs of residents and easily accepts mixing of hybrid programs such as work and residence. Constructive flexibility allows residents to create identity by freely planning interior space and changing the size or location of facade components in a determined system of architects. Finally, various types of size and space composition are proposed and realized in the whole building applying menu selection method, so that flexibility in the offer can accommodate and integrate various types of living.

A Study on the Characteristics of Garden Architecture in Italian Renaissance Villa Lante (이탈리아 르네상스 빌라 란테의 정원건축적 특성)

  • Choi, Jong-Hee
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.29 no.2
    • /
    • pp.90-98
    • /
    • 2011
  • This study aims to discuss the characteristics of garden architecture in Italian Renaissance Villa Lante that was constructed by the cardinal in Bagnaia at 16th century through actual survey and analysis of the garden's elements. To do this, it was studied in two ways: Analysis of the present conditions and review historical documents. The results are as follows. First, the buildings, the gardens and the surrounding landscapes are visually connected each other in relations between the topography and the surrounding landscapes. Second, the spatial composition accepted Neoplatonic law of multiple proportions and was influenced by ancient myth and "Liber ruralium commodorum" of Pietro de Crescenzi(1305). Third, the garden's elements consist of plants, buildings and items. In plants, the upper plants are fir tree, cypress and pine tree and the lower plants are english holly, box tree and sweet oleander. The buildings are casino, loggia and terrace. The items are pot, sundial, chair, viewing platform and fountain. The result of this study, the political and social, technical phenomena which constitute construction pattern affected the locational property and the spatial organization of the neighbor on Villa Lante.

A Study on the Characteristics of Planning of Hwa-sung from the Point of Water System (수체계로 본 수원화성 건설의 계획적 특성에 관한 연구)

  • Kang, In-Ae
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.29 no.4
    • /
    • pp.137-147
    • /
    • 2011
  • This study aims to find out the construction process and planning characteristics of Suwon and Hwa-sung in 18th century from the point of water system. This study has an explanatory approach. The planning intents in the water system was driven out by analyzing various planning elements in relation to water system in the process of constructing Hwa-sung in 18th century. Using Entire Map of Hwa-sung, land registration map made in 1911 and topographic map of 1/10,000 scale made in 1917, water system and interpretation of spatial structure in Hwa-sung were analyzed. The results are as follows(Planning characteristics of the water system in Haw-sung in 18th century are as follows). Firstly, in determining the spatial structure and location of Hwa-sung, water system had an important role. Secondly, integrated drainage system was planned by the organization of natural and artificial water stream. Thirdly, the main street system and land use structure were planned in relation with water system. Fourthly, territoriality of main area was planned with water stream. Fifthly, ponds were constructed for flood control and they had important role as landscape elements. Sixthly, water stream was used as intentional BiBo element. As a result of the study, the weater system of Hwa-sung in 18th century was planned by the organization of natural and artificial water stream in relation with the location of new town and wide area's spatial structure, street system, land use structure, territoriality of main area, terriflood control, water quality protection, landscape, 비보 and urban daily life.

Analysis of The Human Thermal Environment in Jeju's Public Parking Lots in Summer and Suggestion for Its Modification (제주시 공영 주차장 내 여름철 인간 열환경 분석 및 저감 방안 제안)

  • Choi, Yuri;Park, Sookuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.52 no.3
    • /
    • pp.18-32
    • /
    • 2024
  • This study aims to analyze the summer human thermal environment in Jeju City's outdoor parking lots by measuring microclimate data and comparing pavement and vegetation albedoes and elements through computer simulations. In measured cases, results due to albedo showed no significance, but there was a significant difference between sunny and shaded areas by trees. The sunny area had a PET (physiological equivalent temperature) in the 'very hot' level, while the shaded area exhibited a 2-step lower 'warm' level. UTCI (universal thermal climate index) also showed that the sunny area was in the 'very strong heat stress' level, whereas the shaded area was 1-step lower in the 'strong heat stress' level, confirming the role of trees in reducing incoming solar radiant energy. Simulation results, using the measured albedoes, closely resembled the measured results. Regarding vegetation, scenarios with a wide canopy, high leaf density, and narrow planting spacing were effective in mitigating the human thermal environment, and the differences due to tree height varied across scenarios. The scenario with the lowest PET value was H9W9L3D8 (tree height 9m, canopy width 9m, leaf area index 3.0, planting spacing 8m), indicating a 0.7-step decrease compared to the current landscaping scenario. Thus, it was confirmed that, among landscaping elements, trees have a significant impact on the summer human thermal environment compared to ground pavement.

A Study on the Possibility of Utilizing Both Biotope Maps and Land Cover Maps on the Calculation of the Ecological Network Indicator of City Biodiversity Index (도시생물다양성 지수(CBI) 중 생태네트워크 산정을 위한 도시생태현황지도 및 토지피복지도 활용 가능성 연구)

  • Park, Seok-Cheol;Han, Bong-Ho;Park, Min-Jin;Yun, Hyerngdu;Kim, Myungjin
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.6
    • /
    • pp.73-83
    • /
    • 2016
  • This study modified and applied the ecological network(Indicator 2) from the City Biodiversity Index(CBI) to be tailored to Korea. It is calculated by utilizing a biotope map and a land cover map. The ecological network of Gyeryong-Si was 13,713,703(33.8%) with the biotope map and 17,686,966(37.9%) with the land cover map. The result of the biotope map was lower than the land cover map. The ecological network of Goyang-Si was 4,961,922(4.9%) with the biotope map and 4,383,207(3.7%) with the land cover map. The result of the land cover map was lower than the biotope map. As a main result of the research, an error was discovered in which, when calculating the ecological network, the types of the military unit facilities were distinguished into a special area on the biotope map and into an urbanization promotion area and a forest area on the land cover map. In the case of a middle-classified, land cover map, the land use in the surroundings of the forest area was not subdivided. An error in the development area expressed as a forest green was discovered. When selecting the natural elements, too, regarding the types of artificially-created rivers, artificial ponds, and artificial grasslands, etc. on a biotope map, the exclusions were necessary. Regarding the natural, bare ground on a land cover map, there was a need to calculate by including the natural elements. It was judged that, in the future, the ecological network in the unit of the entire nation can be analyzed roughly by utilizing a land cover map. It was judged that, in a city having a biotope map, the calculation of the ecological network utilizing a map of the present situation of the urban ecology will be a more accurate diagnosis of the present situation.

Seismic Performance of Special Shear Wall with Modified Details in Boundary Element Depending on Axial Load Ratio (축력비에 따른 수정된 단부 횡보강상세를 갖는 특수전단벽의 내진성능)

  • Chun, Young-Soo;Park, Ji-Young
    • Land and Housing Review
    • /
    • v.7 no.1
    • /
    • pp.31-41
    • /
    • 2016
  • In this paper, we propose experimental results, which target the major variables that influence the structural performance of a wall, as well as the resulting seismic and hysteretic behavior. Results also provide the basis for the application of performance based design by identifying the nonlinear hysteretic behavior of the wall with boundary element details recently proposed in previous study by Chun et al(2011). From the experimental results, the crack and fracture patterns of a specimen, which adopt the proposed boundary element details, showed similar tendencies regardless of whether axial force or high performance steel bars is applied. Furthermore, results show that the maximum strength of the specimen can be predicted accurately based on the design equation proposed by the standard. In addition, with a higher axial force, there is a tendency that both the initial load and maximum strength increase as deformation capacity reduces, requiring consideration of the reduced deformation capacity due to a high axial force. For walls under such high axial forces, using high performance steel bars is a very effective manner of enhancing deformation capacity. Therefore, reinforcing the plastic hinge region with boundary elements using high performance steel bars is preferable.

Some Considerations for the Fire Safe Design of Tall Buildings

  • Cowlard, Adam;Bittern, Adam;Abecassis-Empis, Cecilia;Torero, Jose L.
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.63-77
    • /
    • 2013
  • In any subject area related to the provision of safety, failure is typically the most effective mechanism for evoking rapid reform and an introspective assessment of the accepted operating methods and standards within a professional body. In the realm of tall buildings the most notable failures in history, those of the WTC towers, widely accepted as fire induced failures, have not to any significant extent affected the way they are designed with respect to fire safety. This is clearly reflected in the surge in numbers of Tall Buildings being constructed since 2001. The combination of the magnitude and time-scale of the WTC investigation coupled with the absence of meaningful guidance resulting from it strongly hints at the outdatedness of current fire engineering practice as a discipline in the context of such advanced infrastructure. This is further reflected in the continual shift from prescriptive to performance based design in many parts of the world demonstrating an ever growing acceptance that these buildings are beyond the realm of applicability of prescriptive guidance. In order for true performance based engineering to occur however, specific performance goals need to be established for these structures. This work seeks to highlight the critical elements of a fire safety strategy for tall buildings and thus attempt to highlight some specific global performance objectives. A survey of tall building fire investigations is conducted in order to assess the effectiveness of current designs in meeting these objectives, and the current state-of-the-art of fire safety design guidance for tall structures is also analysed on these terms. The correct definition of the design fire for open plan compartments is identified as the critical knowledge gap that must be addressed in order to achieve tall building performance objectives and to provide truly innovative, robust fire safety for these unique structures.

Fragility Analysis of A Scaled Model of Reinforced Concrete Column in Accordance with Similitude Law (상사법칙이 적용된 철근콘크리트 기둥 축소모형의 지진 취약도 분석)

  • Park, Dong Uk;Jeon, Bub Gyu;Kim, Nam Sik;Park, Jamin;Cho, Jae-Yeol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.87-93
    • /
    • 2017
  • Many studies are conducted in several fields for fragility analysis of structures or elements which is a probabilistic seismic safety analysis in consideration with uncertainty of seismic loading. It is hard to directly conduct fragility analysis for an infrastructure with social importance due to its size. Therefore, a fragility analysis for an infrastructure mainly conducted in element level or conducted with scaled model built in accordance with similarity law. In this article, fragility analysis for prototype and scaled model of reinforced concrete column was conducted with numerical models which had been updated by the results of shaking table test and pseudo dynamic test. As a result, response stress from the numerical analysis result of prototype model was higher than that from scaled model due to different stiffness ratios between steel and concrete. However, the probability of failure for scaled model was higher than that for prototype model because failure criteria for scaled model was down due to similarity law. Also it was evaluated that probability of failure by using log normal standard deviation of response stresses by spectrum matched accelerograms was more reliable than probability of failure by using existing coefficient of variation normally used.