• 제목/요약/키워드: Ups

검색결과 1,690건 처리시간 0.033초

대규모 무정전 전원공급 시스템의 구성방안 (The Configurations of the large scale UPS system)

  • 송언빈;윤병도
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1991년도 추계학술발표회논문집
    • /
    • pp.80-83
    • /
    • 1991
  • The need of UPS (Uninterruptible Power Sup-ply) system is dramatically increasing with the increased use of computers, telecommunica-tion system, building automation system, and office automation system in office buildings. The consequence of the power failure is very disas trous in intelligent office buil-dings. Thus, the nucessity of large scale UPS system with generations of large scale UPS system with generator is increasing. In this study, the configurations of large scale UPS system are reviewed and analyzed. The design guide and technical considerations of high reliability system are presented.

  • PDF

UPS management system in the HFC network

  • Kim, Young-Wha;Kang, Jun-Woo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.121.3-121
    • /
    • 2002
  • The HFC network is one of the most useful network for high-speed data communication. Optical node unit, Trunk branch amplifier, Tap-offs, and Uninterrupted power supplies (UPS) are in this network. Since power failures of the equipments in the network is crucial, UPS should be periodically monitored and controlled by the Host to prevent long power failures. This paper describes a UPS management system which is to monitor and control UPS to supply electric power to ONUs and TBAs in the network.

  • PDF

단상 다기능 UPS 입.출력 필터 설계 (Design of Input.Output Filter of Single Multifunctional UPS)

  • 김제홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.307-310
    • /
    • 2002
  • A design for the input filter and the output filter of a single-phase UPS system is proposed. And also, this paper describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.

  • PDF

스위칭 소자에 의한 UPS의 특징 (The characteristic of UPS by Switching Element)

  • 강용철;차인수;이경섭;박해암;이우선
    • 한국통신학회:학술대회논문집
    • /
    • 한국통신학회 1991년도 추계종합학술발표회논문집
    • /
    • pp.220-224
    • /
    • 1991
  • Uninterruptible Power Supply(UPS) Systems are widely used in a varietyof fields as highly reliable power sources. This paper describes the operation and performance of an UPS using sinusoidal Pulse Width Modulation (PWM)techniques. A newly developed UPS adopted switching element -power TR, power MOSFET, IGBT- is introduced. Experimental results showed that sinusoidal PWM techniques have good features for UPS systems.

3상 4선식 UPS 인버터의 2-병렬운전 (2-parallel operation of inverters in 3-phase 4-wires UPS)

  • 지준근;꽁섬낭;구대관
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.544-545
    • /
    • 2012
  • 본 논문에서는 3상 4선식 UPS 인버터에 대한 저항성 수하 제어 방식 병렬운전 알고리즘을 제안하고, PSIM 시뮬레이션을 통해서 제안된 병렬운전 알고리즘과 강인 전압제어기를 적용한 2병렬 UPS 인버터의 운전 결과를 제시한다. 3상 UPS 인버터 2대로 병렬운전 환경을 구축하였고, 주파수-전압 강하 방식의 저항성 수하 제어를 이용하여 저항 부하, 유도성 부하, 비선형 부하에 대한 전력분담을 확인하였다.

  • PDF

발전기를 이용한 동기조상기 및 UPS 기능구현에 관한 연구 (A Study on Implementation of Synchronous Ancillary System and UPS Function Using Generator)

  • 최해선;김병각;양지훈;박성준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.362-363
    • /
    • 2019
  • 비상발전기를 사용하여 무정전 시스템을 구성할 경우, 발전기 시스템이 정전을 인식하고 비상발전기의 기동하는 시간동안은 정전이 발생함으로 통상적으로 단주기 ESS와 결합한 UPS 시스템을 구축하게 된다. 이 경우 UPS 시스템 구축을 위한 ESS 시스템과 인버터에 대한 부담이 존재한다. 본 논문에서는 비상발전기와 엔진의 동력전달 부 사이에 플라이휠과 전자식 클러치에 의한 새로운 비상발전기 단독형 UPS 시스템을 제안한다.

  • PDF

Cost-Effective APF/UPS System with Seamless Mode Transfer

  • Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.195-204
    • /
    • 2015
  • In this paper, the development of a cost-effective active power filter/uninterruptible power supply (APF/UPS) system with seamless mode transfer is described. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter and has two operational modes. First, when the source voltage is normal, the system operates as an APF, which compensates for the harmonics and power factor while boosting the DC-link voltage to be ready for the disturbance, without an additional DC charging circuit. A simple algorithm to detect the load current harmonics is also proposed. Second, when the source voltage is out of the normal range (owing to sag, swell, or outage), it operates a UPS, which controls the output voltage constantly by discharging the DC-link capacitor. Furthermore, a seamless transfer method for the single-phase inverter between the APF mode and the UPS mode is also proposed, in which an IGBT switch with diodes is used as a static bypass switch. Dissimilar to a conventional SCR switch, the IGBT switch can implement a seamless mode transfer. During the UPS operation, when the source voltage returns to the normal range, the system operates as an APF. The proposed system has good transient and steady-state response characteristics. The APF, charging circuit, and UPS systems are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF/UPS system rated at 3 kVA.

다른 정격용량을 가진 3상 UPS 시스템의 병렬운전을 위한 주종제어 기법 (A Master and Slave Control Strategy for Parallel Operation of Three-Phase UPS Systems with Different Ratings)

  • 이우철;현동석
    • 전력전자학회논문지
    • /
    • 제9권4호
    • /
    • pp.341-349
    • /
    • 2004
  • 본 논문에서는 전체 시스템의 용량 증대와 부하 중요도에 따른 신뢰성 향상을 위해 사용되는 UPS 병렬 운전시 발생하는 문제점을 해석하고, 이를 해결하기 위해 기존에 연구되어온 다양한 제어기법들을 조사하였다. 또한 기존의 연구방법에서 적용할 수 없었던 다른 정격의 병력 운전 적용시 L, C 출력필터에 의한 문제점을 해결하기 위해 주종 제어를 이용한 3상 UPS의 전류 분달 제어기법이 연구되었다. 제안된 제어 알고리즘의 타당성을 검증하기 위해 시뮬레이션 및 실험을 수행하였다.

다중-레퍼런스/다중-출력 FXLMS 알고리즘에 의한 UPS 팬 소음저감 특성해석 (Characteristin Analysis of UPS Fan Noise Reduction by Multiple-Referedce/Multiple-Output FXLMS Algorithm)

  • 이승요;조준석;최규하
    • 전력전자학회논문지
    • /
    • 제4권6호
    • /
    • pp.589-600
    • /
    • 1999
  • 사무실에서 사용되는 소용량 무정전진원 장치(UPS : Uninterruptible Power Supply)는 대부분의 소음이 냉각팬을 통하여 발생되고 있는데, 이와 같이 장치의 여러 방향으로 방사되는 소음의 능동적 소음제어를 위해서는 FXLMS(Filtered-x LMS) 알고리즘에 기초를 둔 다중채널 방식의 FXLMS(multiple-channel FXLMS) 알고리즘의 사용이 적당하다. 본 논문에서는 사무실에서 주로 사용되는 소용량 UPS의 소음 발생 특성을 분석하고 다중채널 방식 MRMO(Multiple-Reference/Multiple-Output) FXLMS 알고리즘을 적용하여 방사상으로 전파되는 UPS의 소음을 저감시키기 위한 능동 소음 제어를 수행하고 이의 소음저감 특성을 고찰한다.

  • PDF

AHP에 기반을 둔 기술창업 요인 분석 시스템 (AHP-based Technology Start-ups Factors Analysis System)

  • 전향순;이상용
    • 디지털융복합연구
    • /
    • 제13권4호
    • /
    • pp.311-317
    • /
    • 2015
  • 사회경험이 부족한 대학생들의 기술창업을 체계적이고 성공적으로 지원하기 위해서는 대학생에게 특화된 창업 영향요인을 분석하여 제공하는 것이 중요하다. 그러나 현재에는 통계 패키지에 의존하여 기술창업 요인 분석이 이루어짐으로써 지속적으로 변화하는 창업환경 분석이 곤란하다는 문제점이 발생하고 있다. 본 논문에서는 AHP를 이용하여 기술창업 의사결정에 관한 영향요인을 계층구조로 나타내고 전처리 후 판단행열에 입력, 표준화값 및 가중치 산정, 일관성 검증, 가중치 종합화를 통한 우선순위를 도출하여 분석할 수 있는 ATSA시스템을 제안하였다. ATSA 시스템은 창업자의 내외적 요인과 지속적으로 변화하는 다양한 창업환경 분석에 다기준 의사결정을 적용하여 정성적인 요인들을 정량적으로 분석함으로써, 기술창업을 위한 의사결정을 효율적으로 지원할 수 있음을 실험을 통해 확인하였다.