• 제목/요약/키워드: Upper-Air

검색결과 898건 처리시간 0.026초

Degassing 조건이 Ni-Cr 합금의 도재결합력에 미치는 영향 (EFFECT OF DEGASSING CONDITION ON CERAMIC BOND STRENGTH OF Ni-Cr ALLOYS)

  • 이은화;전영찬;정창모;임장섭
    • 대한치과보철학회지
    • /
    • 제38권4호
    • /
    • pp.461-471
    • /
    • 2000
  • This study evaluated the effect of degassing on the ceramic bond strength of two Ni-Cr alloys under varying holding time at the upper limit temperature and atmospheric conditions. Metal specimens were divided into 5 groups for each alloy according to degassing conditions prior to porcelain application no degassing, degassing under vacuum without hold, degassing under vacuum with hold for 5 min. and 10 min. respectively at the upper limit temperature and degassing in air. Total number of metal ceramic specimens was eighty and each group had eight specimens. The ceramic bond strength was measured by four-point flexural test using Instron and the fractured surface was examined under SEM. The results obtained were as follows. 1. Degassing in air improved the ceramic bond strength of Ni-Cr alloys. 2. In degassing under vacuum, hold at the upper limit temperature was advantageous to the ceramic bonding of Ni-Cr alloys. 3. After ceramic metal bond test, metal surfaces were partially covered with the thin porcelain layer, and the cohesive failures in porcelain were predominant in groups showing higher ceramic bond strength.

  • PDF

건식온돌시스템의 전열특성 및 방열성능에 관한 이론적 분석 (Theoretical Analysis on Heat Transfer Characteristics and Heat Flux Performance in Ondol Systems of Dried Type)

  • 장용성;유기형;조동우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.176-181
    • /
    • 2007
  • This study aims to evaluate theoretically heat transfer characteristics and heat flux performance in ondol system of dried type is composed of panel of ceramics to improve of thermal conductivity and fin to expand heat. To this end, we analyzed effect of design factors(temperature of hot water, set temperature of room and thermal conductivity of finishing materials) in ondol system of dried type by heat transfer analysis. The main results of this study are summarized as follows; The deviation of heat flux and temperature was reduced by heat expansion from fin decreasing heat loss generated in air layer. The temperature and heat flux in upper finishing materials surface linearly increased according to temperature increment of hot water, but the temperature distribution in upper surface was assessed uneven. The greater heat resistance value of upper finishing materials, the deviation of maximum temperature and minimum temperature was decreased. Also, we suggested a basic design data about ondol system of dried type through an analysis of simulation results on heat transfer characteristics and heat flux performance.

  • PDF

MESOPUFF II모델을 이용한 서울시 $SO_2$배출량이 주변지역 대기질에 미치는 영향 분석 (Effects of Emission from Seoul Metropolitan Area on Air Quality of Surrounding Area Using MESOPUFF II Model)

  • 조창래;이종범
    • 한국대기환경학회지
    • /
    • 제14권6호
    • /
    • pp.563-576
    • /
    • 1998
  • To study the influences of the emission sources during lune 13∼15 1997 in Seoul, MESOPVFF II model has been used. The MESOPVFF II model includes terrain effects, chemical transformation and removal processes. Data of 20 surface meteorological stations and the upper air station on mid-west area in Korea were used as a DWM (Diagnostic Wind Model) input data. This model is likely to be applicable because the predicted SO2 concentration was well matched with measured 502 concentration in Seoul and Kyonggido. In generally air pollutants in Seoul have major influence on the other cities but the result of modeling appeared also air pollutants of the other cities influence on Seoul. Finally, in the case of calculating the air quality by diffusion model, the influences of air pollutants emitted in metropolitan area as well as the emission rate in modeling area should be considered.

  • PDF

철도차량용 공기스프링의 특성 예측 및 평가 (Prediction and Evaluation of Characteristics of Air Spring for Railroad Vehicle)

  • 김완두;허신;김석원;김영구
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.626-633
    • /
    • 2000
  • An air spring which is a part of the railroad vehicle suspension system is used to reduce and absorb the vibration and the noise. Main components of the air spying are a cord reinforced rubber bellows, a upper plate, a lower plate and a stopper rubber spring. The characteristics of the air spring which are the load capacity, the vertical and the horizontal stiffness are depended on the configuration of rubber bellows, the angle of cord and the mechanical properties of cord. The computer simulation using commercial finite element analysis codes are executed to predict and evaluate the load capacity and the stiffness. The appropriate shape and cord angle of the air suing are selected to adjust the required performance of the air spring. Several samples of the air spring are manufectured and experimented. It is shown that the results by computer simulation are in close agreement with the test results.

  • PDF

수직 배열된 평판에서 혼합대류 열전달 (Mixed Convection Heat Transfer from Vertical In-Line Plates)

  • 김상영;이재신;권순석
    • 설비공학논문집
    • /
    • 제3권2호
    • /
    • pp.123-130
    • /
    • 1991
  • The mixed convection heat transfer from vertical inline plates has been studied numerically by the finite difference method and experimentally with Mach-Zehnder interferometer. The dimensionless spacing, $s/L_1$, the relative length, $L_2/L_1$ and the dimensionless temperature ratio, ${\Phi}_2/{\Phi}_1$ are varied parametically. The lower plate mean Nusselt numbers show same values as $s/L_1$, ${\Phi}_2/{\Phi}_1$ and $L_2/L_1$ increase. The upper plate mean Nusselt numbers increase as $s/L_1$ and ${\Phi}_2/{\Phi}_1$ increase, but $L_2/L_1$ decreases. The upper plate mean Nusselt number is higher than the lower plate mean Nusselt for $s/L_1$ 1.8 at Re=100, $Gr=10^4$, Pr=0.71, $L_2/L_1=0.5$ and ${\Phi}_2/{\Phi}_1=1.0$. A comparison between the experimental and numerical results show good agreement.

  • PDF

COMPARISON OF TEMPERATURE DERIVED FROM THE MICROWAVE SOUNDING UNIT AND MONTHLY UPPER AIR DATA.

  • Hwang, Byong-Jun;Kim, So-Hyun;Chung, Hyo-Sang
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.491-495
    • /
    • 1999
  • We compared the satellite observed temperature with the radiosonde observed temperature in the Korean Peninsula. The radiosonde observed data were obtained from four upper air observation stations in the Korean Peninsula from 1981 to 1998, and that was compared with the satellite observed data of the channel-2 and channel-4 of microwave sounding unit(MSU) on board NOAA series of polar-orbiting satellites. The radiosonde data were reconstructed into monthly radiosonde T$_{b}$ using MSU weighting function. The monthly climatology shows radiosonde T$_{b2}$ is higher than MSU T$_{b2}$ in summer. The correlation between MSU T$_{b2}$ and radiosonde T$_{b2}$ is 0.72-0.76 and 0.73-0.81 between MSU T$_{b4}$ and radiosonde T$_{b4}$.

  • PDF

흥미 있는 기도 이물 3 례 (Interesting Foreign Bodies in the air way.)

  • 박옥희;천만희;조중환
    • 대한기관식도과학회:학술대회논문집
    • /
    • 대한기관식도과학회 1982년도 제16차 학술대회연제순서 및 초록
    • /
    • pp.7.1-7
    • /
    • 1982
  • 흥미 있는 기도 이물 3 례를 치험하였기에 보고하는 바이다. 예 1 ) 10세 남아에서 볼펜 용수철이 1 년간 우측 하엽기관지에 들어 있어 녹이 슬어 둘로 나누어져 있었던 예 . 예 2 ) 6개월 여아에서 콩이 우측 상엽과 중엽 기관지구에 걸쳐 있어 우측 상엽과 중엽에 완전 무기폐를 초래하였던 예. 예 3 ) 11 개월 남아에서 양말 고정 철사가 epiqlottis와 hypopharynx에 1 개월간 걸려 있었던 예.

  • PDF

Prolonged Air Leakage Caused by Mesenchymal Cystic Hamartoma of the Lung

  • Lee, Young Uk;Lee, Jang Hoon;Baek, Jong Hyun
    • Journal of Chest Surgery
    • /
    • 제49권4호
    • /
    • pp.302-305
    • /
    • 2016
  • A 16-year-old girl was transferred to the department of thoracic and cardiovascular surgery because of a spontaneous pneumothorax with prolonged air leakage. Chest computed tomography demonstrated a cystic lesion measuring $2{\times}3cm$ and involving the left upper lobe. Left upper lobectomy was performed via video-assisted thoracoscopic surgery. A pathologic examination of the specimen revealed a mesenchymal cystic hamartoma. Despite the rarity of pulmonary mesenchymal cystic hamartoma, it should be considered a potential cause of pneumothorax for patients with a large pulmonary cyst. Further, surgical resection must be considered because serious complications such as hemothorax, hemoptysis, and malignant transformation have been reported.

상부채널을 갖는 사각공간에서 열유속 변화에 따른 공기대류의 속도와 온도 가시화 (Velocity and temperature Visualization of Air Convection in Differently Heated Rectangular Cavity with Upper channel)

  • 이철재;정한식;박찬수;조대환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.290-295
    • /
    • 2000
  • An experimental study was carried out in a cavity with upper channel and square heat surface by visualization equipment with Mach-Zehnder interferometer and laser apparatus. The visualization system consists of 2-dimensional sheet light by Argon-Ion Laser with cylindrical lens and flow picture recording system. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system(CACTUS'2000). Obtained result showed various flow patterns. Severe unsteady flow fluctuation within the cavity are remarkable and sheared mixing layer phenomena are also found at the region where inlet flow is collided with the counter-clockwise rotating main primary vortex. Photographs of Mach-Zehnder are also compared in terms of constant heat flux.

  • PDF

특별피난계단 부속실 제연설비의 방연풍속 측정 방법에 관한 연구 (Study on Measurement Method of Air Egress Velocity in Vestibule of Smoke Control System)

  • 이수경;홍대화
    • 한국화재소방학회논문지
    • /
    • 제25권3호
    • /
    • pp.85-90
    • /
    • 2011
  • 본 연구는 국내 고층건물 특별피난계단의 부속실에 설치되는 급기가압 제연시스템에서 화재 발생 시 피난을 위하여 출입문이 개방되었을 경우 형성되는 방연풍속의 특성을 FDS를 이용하여 해석하였고, 해석 결과를 분산분석으로 기류의 특성에 따른 측정 방안을 분석하고자 한다. 부속실과 같은 구획공간의 설계 조건에서 급기댐퍼에서 토출되는 보충량은 심한 와류를 형성하고 형성된 와류의 범위 안에 출입문이 존재할 경우 비정상적인 기체의 유동이 출입문지점에 발생한다는 것을 선행연구를 통하여 확인할 수 있었다. 국가화재안전기준 NFSC 501A에서 방연풍속을 측정할 때에는 출입문의 개방에 따른 개구부를 대칭적으로 균등 분할하는 10 이상의 지점에서 측정하는 풍속의 평균치로 할 것으로 정하고 있으나 이러한 조건에서는 출입구 상부 지점에 기류의 유입 현상을 파악하기 어렵고 풍속의 편차가 심하기 때문에 측정점을 공기조화설비의 시험조정 평가 기술기준에서 제시하는 64점 이상으로 세분화하여 측정하여야 할 것이다.