• Title/Summary/Keyword: Upper air passage

Search Result 9, Processing Time 0.021 seconds

The Study on the Frontal Thunderstorm during Winter Time in the Korean Peninsula (우리나라 동계 전선성 뇌우에 관한 연구)

  • Kim, Jong-Seok;Park, Sang Hwan;Ham, Sook Jung;Ban, Ki-Song;Choi, Young Jean;Chang, Dong-Eon;Chung, Hyo-Sang
    • Atmosphere
    • /
    • v.16 no.4
    • /
    • pp.351-358
    • /
    • 2006
  • The structure of frontal thunderstorm in winter time is different from that of in summer time over the Korean peninsula, due to dry tongue and upward motion. The dry tongue, that is propagation of dry zone from upper level to lower level, was formed after front passage and the upward motion is intensified by the strengthened low level jet. Since this mechanism makes the structure more unstable, thunderstorm occurs at relatively low cloud top height. This study suggests a forecast guidance of winter time frontal thunderstorm that thunderstorms develop when one of the following conditions are satisfied: 1) total totals (TT) >40, 2) K index >-10, 3) mixing ratio ${\geq}$ 3.5 g/kg.

An Application of K-$\varepsilon$ Turbulence Model for Predicting Effect of a Rectanguler Obstacle with Heat Flux in a Solt-Ventilated Enclosure on Air Flow

  • 최홍림;김현태;김우중
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.34 no.E
    • /
    • pp.30-44
    • /
    • 1992
  • A modification of the TEACH-like computer program based on the k-$\varepsilon$ turbulence transport was applied for predicting air mixing patterns and temperature distributions in a rectangular, slot-ventilated enclosure having obstructions ; a rectangular obstacle with heat flux, solid walls separates the passage and the pig pens, and purlins beneath the ceiling. Air flow patterns were calculated for the cases with and without the purlin, extending 300mm beneath the ceiling. Comparisons of prediction data of Randall & Battams(1976) showed air flow pattern predicted well for the case without the purlin. Heat was accumulated at the corner of the left side of the solid wall and the right-upper region of the simulated pigs. However the air distribution pattern was completely different from data for the case with the purlin. The deviation from the observation may be attributed to the difference of the geometric configuation. Exploring the cause of the deviation should be conducted in a further study. Temperature stratification was also observed due to incomplete mixing. The obstruction in the route of the inlet air jet at inlet should be avoided since most of kinetic energy dissipates at the abstacle duet to impingement.

  • PDF

Study on Numerical Model of Leakage Flow at Gap between Compartments in a Building (건축물 구획실간 틈새에서의 누설유동에 대한 수치모델 연구)

  • Kim, Jung-Yup;Kim, Ji-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.10
    • /
    • pp.562-567
    • /
    • 2013
  • 1D-numerical analysis of the network algorithm with the orifice equation for the relationship between pressure difference and flowrate has been mostly used to analyse leakage flow at the gap. In this study, a 3D-numerical method applying momentum loss model to the gap region in the computational domain is represented to reflect effectively the effect of leakage flow by determining the proportion of pressure difference to air passage velocity. While the 3D-numerical method is verified through the computation of the two compartments model, the numerical analysis of the stack effect in a building stairway is performed. As the temperature of air outside drops, the pressure in the upper stairway and leakage flowrate through the gap in the door rise. The change of gap area does not have an effect on pressure in the stairway for the analysis conditions.

Vertical Atmospheric Structure and Sensitivity Experiments of Precipitation Events Using Winter Intensive Observation Data in 2012 (2012년 겨울철 특별관측자료를 이용한 강수현상 시 대기 연직구조와 민감도 실험)

  • Lee, Sang-Min;Sim, Jae-Kwan;Hwang, Yoon-Jeong;Kim, Yeon-Hee;Ha, Jong-Chul;Lee, Yong-Hee;Chung, Kwan-Young
    • Atmosphere
    • /
    • v.23 no.2
    • /
    • pp.187-204
    • /
    • 2013
  • This study analyzed the synoptic distribution and vertical structure about four cases of precipitation occurrences using NCEP/NCAR reanalysis data and upper level data of winter intensive observation to be performed by National Institute of Meteorological Research at Bukgangneung, Incheon, Boseong during 63days from 4 JAN to 6 MAR in 2012, and Observing System Experiment (OSE) using 3DVAR-WRF system was conducted to examine the precipitation predictability of upper level data at western and southern coastal regions. The synoptic characteristics of selected precipitation occurrences were investigated as causes for 1) rainfall events with effect of moisture convergence owing to low pressure passing through south sea on 19 JAN, 2) snowfall events due to moisture inflowing from yellow sea with propagation of Siberian high pressure after low pressure passage over middle northern region on 31 JAN, 3) rainfall event with effect of weak pressure trough in west low and east high pressure system on 25 FEB, 4) rainfall event due to moisture inflow according to low pressures over Bohai bay and south eastern sea on 5 MAR. However, it is identified that vertical structure of atmosphere had different characteristics with heavy rainfall system in summer. Firstly, depth of convection was narrow due to absence of moisture convergence and strong ascending air current in middle layer. Secondly, warm air advection by veering wind with height only existed in low layer. Thirdly, unstable layer was limited in the narrow depth due to low surface temperature although it formed, and also values of instability indices were not high. Fourthly, total water vapor amounts containing into atmosphere was small due to low temperature distribution so that precipitable water vapor could be little amounts. As result of OSE conducting with upper level data of Incheon and Boseong station, 12 hours accumulated precipitation distributions of control experiment and experiments with additional upper level data were similar with ones of observation data at 610 stations. Although Equitable Threat Scores (ETS) were different according to cases and thresholds, it was verified positive influence of upper level data for precipitation predictability as resulting with high improvement rates of 33.3% in experiment with upper level data of Incheon (INC_EXP), 85.7% in experiment with upper level data of Boseong (BOS_EXP), and 142.9% in experiment with upper level data of both Incheon and Boseong (INC_BOS_EXP) about accumulated precipitation more than 5 mm / 12 hours on 31 January 2012.

Radiation Therapy (RT) of Midline Granuloma (중앙성육아종의 방사선치료)

  • Kwon, Hyoung-Cheol;Oh, Yoon-Kyeong;Gil, Hak-Jun;Yoon, Sei-Chul;Bahk, Yong-Whee
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.135-139
    • /
    • 1986
  • Seven patients having midline granuloma received local irradiation from March 1983 to June 1986. Clinically, all of the 7 patients had pansinusitis with necrotic destruction of the involved sites and one case revealed colonic lesion. Each of the patients received a tumor dose of $4,000\~5,000 cGy/5\~6$ wks to the upper aerodigestive tract using a 6-MV linear accelerator. Complete and partial remission occured in 3 patients each, and in one case, the disease progressed despite of the irradiation.

  • PDF

A numerical study on the performance of the smoke exhaust system according to the smoke exhaust method in emergency station for railway tunnel (철도터널 구난역의 제연방식에 따른 제연성능에 관한 수치 해석적 연구)

  • Ryu, Ji-Oh;Kim, Jin-Su;Seo, Jong-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.6
    • /
    • pp.845-856
    • /
    • 2017
  • In the long railway tunnel, in order to secure safety in case of fire, it is required a emergency station. However, there is no standard or research results on smoke exhaust method and exhaust flow rate in emergency station, so it is necessary to study the smoke exhaust system for emergency station. In this study, we are created a numerical analysis model for emergency station where the evacuation cross passage connected to the service tunnel or the relative tunnel was installed at regular intervals (40 m intervals). And the fire analysis are carried out by varying the fire intensity (15, 30MW), the smoke exhaust method (only air supply, forced air supply and exhaust, forced air exhaust only), and the air flow rate (7, 14, $40m^3/s$). From the results of fire analysis, temperature and CO concentration are analyzed and ASET based on the limit temperature are compared at various condition. As a result, in the case with fire intensity of 15 MW, it is shown that a sufficiently safe evacuation environment can be ensured by applying forced air supply and exhaust method or forced air exhaust only method when the air flow rate is $7m^3/s$ above. In case of fire intensity of 30 MW, it is impossible to maintain the safety evacuation environment for more than 900 seconds when the exhaust air volume is below $14m^3/s$. And when the air flow rate is $40m^3/s$, the exhaust port is disposed at the side portion of the upper duct, which is most advantageous for securing the temperature-based safety.

On the Characteristics of Vertical Atmospheric Structure in the Western Coastal Region through the Intensive Observation Period (집중관측을 통한 서해연안의 대기 수직구조 특성)

  • 문승의;노재식
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.335-348
    • /
    • 1998
  • The intensive meteorological observations including pibal balloon at Ungcheon, airsonde and 10m meteorological tower observations at Gulup-Do, where are located In the western coastal region, are taken to Investigate the characteristics of the upper and lower atmospheric structure and the local circulation pattern during the period of 17 to 22 September 1996. The diurnal variations of weather elements(i.e. air temperature, humidity, pressure, and Und speeds at Gulup-Do are analyzed and discussed with those at four inland meteorological stations. The vertical profiles of wind vector, ortho- gonality(Ω), and shear obtained from the pibal obsenrations are also presented to examine the change of wand structure according to the synoptic-scale pressure system's movement. The diurnal temperature changes at Gulup-Do are more sensitive than that of Inland meteorological stations In case of the mow of southwesterlies but are not dominant due to the ocean effect under the Influence of relatively cold northerlies. A well defined mixed layer Is developed from the 500m to the maximum 1700m with a significant capping Inversion layer on the top of it. It can be found from the vertical profiles of wind vector that the wind become generally strong at the interface heights between cloud lay- ers and non-cloud layers. The maximum Und shear Is appeared at the bel각t where the varlauon of wand direction Induced by the passage of synoptic-scale pressure system Is accompanied with the In- crease of Und speed. Based on the wind orthogonality, the change of wind direction with height is more complicated In cloudy day than In clear day. In case of a fair weather, the change of wand direction is showed to be at around 2km.

  • PDF

A Study on Improvement of KMA WE-FAX Service (한국기상청 영역기상방송(WE-FAX) 서비스 개선에 관한 연구)

  • Yun, Jong-Hwui;Cook, Sung-Gi;Seol, Dong-Il
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.4
    • /
    • pp.407-412
    • /
    • 2011
  • Even though KMA(Korea Meteorological Administration) has been doing WE-FAX service in past 40 years, most of korean ship's officers use Japan/USA WE-FAX instead of KMA WE-FAX during passage in the NW Pacific. In this regards, the authors carry out the research on the improvement of KMA WE-FAX service, examining the officers's opinions to KMA WE-FAX service along with comparing Korea, Japan & USA synoptic weather charts. As a result, it is suggested that (1) Have KMA WE-FAX service known to the officers in the course of education and training, (2) Persuade ocean-going ships to participate VOS to provide more accurate weather charts. (3) Provide additional weather charts such as Wave analysis, Surface forecast and put useful weather informations on weather charts to enhance navigational safety.

Bifidogenic Effects of Inuloprebiotics in Broiler Chickens (이눌로프리바이오틱스의 브로일러에 대한 비피더스균 활성 효과)

  • Park, Byung-Sung
    • Journal of Life Science
    • /
    • v.18 no.12
    • /
    • pp.1693-1699
    • /
    • 2008
  • Recent studies have suggested that inulin might be utilized as a prebiotics for the promotion of antimicrobial growth, but a major obstacle to the use of inulin has been its low bifidogenic effects, which were initially observed in the ceca of broiler chickens. Inulin has some problems with related to denaturation in air and lowering passage rate from upper digestive tract to caecum. To solve this problems, a newly developed compound derived by microencapsulation, inuloprebiotics, was hypothesized to enrich cecal bifidobacterial populations and reduce the colonization levels of Salmonella in the ceca of broiler chickens. The in vitro growth of intestinal beneficial bacteria including Bifidobacterium longum, Bifidobacterium bifidum, Lactobacillus acidophilus, and Lactobacillus casei grew effectively on the medium containing inulin, whereas the growth of Streptococcus aureus and Clostridium perfringens was not differences among the treatment groups. Broiler chickens consumed chow diets containing 0.5%, 0.7% or 1.0% inuloprebiotics, or a control diet without inuloprebiotics supplementation. The chickens on the inuloprebioticssupplemented diets evidenced significantly higher cecal levels of Bifidobacterium and Lactobacillus species as compared with the chickens on the control diet. The population of cecal E. coli and Salmonella was specifically reduced as the result of treatment with inuloprebiotics. However, we noted no significant differences in Bifidobacterium species, E. coli and Salmonella counts among the inuloprebiotics treatment groups. The inuloprebiotics-supplemented diets induced an increase in the serum IgG concentration. The thymus index was significantly increased in the broiler chickens that consumed diets containing 0.7% or 1.0% inuloprebiotics, with the exception of the chickens consuming the diet supplemented with 0.5% inuloprebiotics. These results indicate that the inuloprebiotic preparations exerted an immune system-promoting effect or selectively enriched the cecal Bifidobacterium species populations in the broiler chickens, and also suggest that inuloprebiotics may prove useful as a stable natural antimicrobial agent.