• 제목/요약/키워드: Upper/Lower Limit

검색결과 357건 처리시간 0.029초

바닥복사 난방공간의 효율적인 난방제어방법 (The Effective Heating Control Method of the Radiant Floor Heating System)

  • 조성환;태춘섭
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.317-329
    • /
    • 1996
  • By describing the floor slab of a radiant heating system as a one dimensional transient heat exchanger problem, a dynamic analysis model to incorperate with TRNSYS program was developed and their results were compared with experimental results. Results showed that the both of TPOC(Two Parameter On-off Control) and TPSC(Two Parameter Switching Control) method using room air temperature and floor surface temperature as the control parameters does not maintain room air and floor surface temperature exactly at the setting temperatures. But TPSC method is a better candidate for the temperature regulations of room air and floor surface temperature than TPOC method which can keep on the upper and lower limit temperature according to outside temeperature and wall structure etc. And better thermal circumstance can be given by TPSC method than On-off and TPOC method and the overheating which can be occured at the radiant floor heating system with on-off heating control will be reduced.

  • PDF

Soil Moisture Measurement of Bare and Vegetated Surfaces by X-band Radars

  • Oh, Yi-Sok;Kwon, Soon-Gu;Hwang, Ji-Hwan
    • Journal of electromagnetic engineering and science
    • /
    • 제10권4호
    • /
    • pp.212-218
    • /
    • 2010
  • The radar backscatter from various earth surfaces is sensitive to the frequency of the incident wave. This study examined the radar sensitivities for surface parameters such as soil moisture content and surface roughness of both bare and vegetated surfaces at X-band. Because L-band frequencies are often used for sensing the surface parameters, the sensitivities of X-band are also compared with those of the L-band. The sensitivities of the X-band radar backscatter were examined with respect to soil moisture content and surface roughness of rough bare soil surfaces. These sensitivities were also examined using the same parameters for vegetated surfaces for various vegetation densities and incidence angles. Use of the X-band radar for soil moisture detection was as effective as L-band radar for bare soil surfaces. For vegetated surfaces, the soil moisture could be detected using an X-band radar at lower incidence angles, where the upper limit of the incidence angles was dependent on vegetation density.

한방 복합치료로 호전된 Guillain-Barre 증후군 환자 증례 (A Case Report on Patient with Guillain-Barre Syndrome Improved by Korean Medical Combined Treatment)

  • 허인;허광호;황의형;신병철;황만석
    • 한방재활의학과학회지
    • /
    • 제25권1호
    • /
    • pp.95-101
    • /
    • 2015
  • Objectives The purpose of this case is to report the improvement after Korean medical combined treatment about patient with Guillain-Barre syndrome. Methods We treated patient using electroacupuncture, moxibustion, herbal medication, and rehabilitation therapy for 59 days. Results The weakness of muscles of upper extremities were recovered to normal level, and the muscle power of lower extremities was improved enough to walking with walker. Conclusions We conclude that Korean medical combined treatment is an effective to improve the power of muscle having weakness. But there is a limit on this report due to sufficient number of case. Further studies will be needed.

Energy approach for dynamic buckling of shallow fixed arches under step loading with infinite duration

  • Pi, Yong-Lin;Bradford, Mark Andrew;Qu, Weilian
    • Structural Engineering and Mechanics
    • /
    • 제35권5호
    • /
    • pp.555-570
    • /
    • 2010
  • Shallow fixed arches have a nonlinear primary equilibrium path with limit points and an unstable postbuckling equilibrium path, and they may also have bifurcation points at which equilibrium bifurcates from the nonlinear primary path to an unstable secondary equilibrium path. When a shallow fixed arch is subjected to a central step load, the load imparts kinetic energy to the arch and causes the arch to oscillate. When the load is sufficiently large, the oscillation of the arch may reach its unstable equilibrium path and the arch experiences an escaping-motion type of dynamic buckling. Nonlinear dynamic buckling of a two degree-of-freedom arch model is used to establish energy criteria for dynamic buckling of the conservative systems that have unstable primary and/or secondary equilibrium paths and then the energy criteria are applied to the dynamic buckling analysis of shallow fixed arches. The energy approach allows the dynamic buckling load to be determined without needing to solve the equations of motion.

On the effect of temperature on the threshold stress intensity factor of delayed hydride cracking in light water reactor fuel cladding

  • Alvarez Holston, Anna-Maria;Stjarnsater, Johan
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.663-667
    • /
    • 2017
  • Delayed hydride cracking (DHC) was first observed in pressure tubes in Canadian CANDU reactors. In light water reactors, DHC was not observed until the late 1990s in high-burnup boiling water reactor (BWR) fuel cladding. In recent years, the focus on DHC has resurfaced in light of the increased interest in the cladding integrity during interim conditions. In principle, all spent fuel in the wet pools has sufficient hydrogen content for DHC to operate below $300^{\circ}C$. It is therefore of importance to establish the critical parameters for DHC to operate. This work studies the threshold stress intensity factor ($K_{IH}$) to initiate DHC as a function of temperature in Zry-4 for temperatures between $227^{\circ}C$ and $315^{\circ}C$. The experimental technique used in this study was the pin-loading testing technique. To determine the $K_{IH}$, an unloading method was used where the load was successively reduced in a stepwise manner until no cracking was observed during 24 hours. The results showed that there was moderate temperature behavior at lower temperatures. Around $300^{\circ}C$, there was a sharp increase in $K_{IH}$ indicating the upper temperature limit for DHC. The value for $K_{IH}$ at $227^{\circ}C$ was determined to be $2.6{\pm}0.3MPa$ ${\surd}$m.

PCN-PZT 압전형 가속도센서의 특성에 관한 연구 (A Study on the Characteristics of PCN-PZT Piezoelectric Acceleration Sensor)

  • 김영덕;김광일;정우철;고재석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권5호
    • /
    • pp.354-360
    • /
    • 1999
  • PCN-PZT piezoelectric acceleration sensors of annular shear mode voltage type were fabricated and their characteristics have been investigated. Field tests are also carried out. To avoid noise problems from the environmental conditions, acceleration sensors employed solid state micro-electronics for pre-amplifier. The calibration procedures based on the principle of the comparison method were adopted for investigating the characteristics of fabricated acceleration sensors. The voltage sensitivity and resonant frequency of fabricated acceleration sensors were 83mv/g, 23kHz, respectively. The lower and upper frequency limit were 4Hz and 9kHz, respectively. The variation of the voltage sensitivity showed 10% at $-406{\circ}C\; and\; 9%\; at\; 121^{\circ}C$ compared to that of reference temperature at $40^{\circ}C$.

  • PDF

Finite element modeling of a deteriorated R.C. slab bridge: lessons learned and recommendations

  • Ho, I-Kang;Shahrooz, Bahram M.
    • Structural Engineering and Mechanics
    • /
    • 제6권3호
    • /
    • pp.259-274
    • /
    • 1998
  • The test results from non-destructive and destructive field testing of a three-span deteriorated reinforced concrete slab bridge are used as a vehicle to examine the reliability of available tools for finite-element analysis of in-situ structures. Issues related to geometric modeling of members and connections, material models, and failure criteria are discussed. The results indicate that current material models and failure criteria are adequate, although lack of inelastic out-of-plane shear response in most nonlinear shell elements is a major shortcoming that needs to be resolved. With proper geometric modeling, it is possible to adequately correlate the measured global, regional, and local responses at all limit states. However, modeling of less understood mechanisms, such as slab-abutment connections, may need to be finalized through a system identification technique. In absence of the experimental data necessary for this purpose, upper and lower bounds of only global responses can be computed reliably. The studies reaffirm that success of finite-element models has to be assessed collectively with reference to all responses and not just a few global measurements.

Multimode Hybrid Control Strategy of LLC Resonant Converter in Applications with Wide Input Voltage Range

  • Li, Yan;Zhang, Kun;Yang, Shuaifei
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.201-210
    • /
    • 2019
  • This paper proposes a multimode hybrid control strategy that can achieve zero-voltage switching of primary switches and zero-current switching of secondary rectifier diodes in a wide input voltage range for full-bridge LLC resonant converters. When the input voltage is lower than the rated voltage, the converter operates in Mode 1 through the variable-frequency control strategy. When the input voltage is higher than the rated voltage, the converter operates in Mode 2 through the VF and phase-shift control strategy until the switching frequency reaches the upper limit. Then, the converter operates in Mode 3 through the constant-frequency and phase-shift control strategy. The secondary-side diode current will operate in the discontinuous current mode in Modes 1 and 3, whereas it will operate in the boundary current mode in Mode 2. The current RMS value and conduction loss can be reduced in Mode 2. A detailed theoretical analysis of the operation principle, the voltage gain characteristics, and the realization method is presented in this paper. Finally, a 500 W prototype with 100-200 V input voltage and 40 V output voltage is built to verify the feasibility of the multimode hybrid control strategy.

탄소함량이 높은 플라이애쉬를 함유한 시멘트 페이스트의 질소산화물 흡착 성능 (Nitrogen Oxides Adsorbing Capacity of High Carbon Fly Ash Containing Cementitious Materials)

  • 이보연
    • 대한건축학회논문집:구조계
    • /
    • 제34권3호
    • /
    • pp.37-42
    • /
    • 2018
  • The use of fly ash in construction materials is increasing worldwide due the various advantages of using it, such as to produce durable concrete, or to use less cement and thus lower carbon dioxide emissions. The quality of fly ash is often determined by loss on ignition value (LOI), where an upper limit of LOI is set in each country for quality control purpose. However, due to many reasons, production of high LOI fly ash is increasing that cannot be utilized in concrete, ending up in landfill. In this study, the effect of fly ash use in cementitious materials on nitrogen oxides adsorption is examined. In particular, the effect of using high LOI, and thus high carbon content fly ash on nitrogen oxides adsorption is investigated. The results suggest that the higher carbon content fly ash is related to higher nitrogen dioxide adsorption, although normal fly ash was also more effective in nitrogen dioxide adsorption than ordinary portland cement. Also, higher replacement rate of up to 40% of fly ash is beneficial for nitrogen dioxide adsorption. These results demonstrate that high carbon fly ash can be used as construction materials in an environmentally friendly way where strength requirement is low and where nitrogen oxides emissions are high.

일반성분분석을 통한 군납 건빵의 배합비 관리 연구 (Study on the Management of Mix Proportioning for the Military Hardtack by Nutritional Components Analysis)

  • 이동헌;정민홍;변지은;이광근
    • 산업식품공학
    • /
    • 제23권1호
    • /
    • pp.16-21
    • /
    • 2019
  • In this study, the nutritional components (moisture, fat, protein, ash) value of military hardtack was collected and analyzed to control the mixing ratio of rice and flour. Hardtack from 4 factories was analyzed by 3 testing organizations certified by the Korean Ministry Food and Drug Safety. In addition, the accuracy and collaborative study possibility of each organization were evaluated in Q-test and HorRat. Also, other hardtack groups with different mixing ratios were compared to quality control of hardtack by I-MR charts. As a result, the HorRat and Q-test values of test organizations were 0.5-6.2 and 0.08-0.91, respectively. The quality of hardtack by the factories was similar. However, for accurate management of the mixing ratio, suggesting both upper and lower limit requirements of the nutritional components is necessary.