A Experimental Study on Structure Modeling of Ginseng Fields Facility (인삼재배시설의 구조모델링을 위한 실험연구)

  • Oh, Hynn-Kyo;Yoon, Seong-Soo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.181-186
    • /
    • 2005
  • The ginseng field structure collapses due to snow and wind. In order to study the structural modeling of ginseng field facility wind velocity test with shading material and strength test with used and unused timber were performed. The result of wind velocity test, we knew the characteristic of shading member of ginseng facility is followed linear regression, accurately. So, we made the assigned wind-value according to wind velocity. The result of strength test, the strength value of used-timber is smaller than the unused-timber and the coefficient of variance is larger than the unused-timber.

  • PDF

A Study on the Composition of Performance Education Space Through Recycling of Small Unused Facilities (소규모 유휴시설의 재활용을 통한 공연교육공간 구성에 관한 연구)

  • Yoon, Won-Deok;Lim, Jong-Yup
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.26 no.1
    • /
    • pp.3-8
    • /
    • 2019
  • Most of the unused facility in urban areas is perceived as an unreasonable space that damages cityscapes. However, unused space has the advantage of having historical value and potential for new development. In consideration of this, various plans have recently been made in terms of cultural use of unused space. The core is the performing arts culture space where various expressions can be expressed. Changes in the educational space that meet the various conditions required in future societies are also one of the topics to be discussed. In this study, we analyze the performance facilities utilizing the unused space and study the direction of educational facilities based on performance.

Economic Evaluation of Unused Space PV System Using the RETScreen Model - A Case Study of Busan, Gangseo-gu - (RETScreen 기반 유휴공간 태양광 발전 시스템의 경제성 평가 연구 - 부산시 강서구 사례를 중심으로 -)

  • Kang, Seongmin;Jeon, Youngjae;Cho, Sung Heum;Lee, Daekyeom;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.8 no.1
    • /
    • pp.21-30
    • /
    • 2017
  • Recently, There has been much discussed about unused space. This space can be used in a variety of ways. Utilizing it as a facility, craft shop, and utilizing renewable energy generation facilities. Especially, in terms of climate change should be supplied renewable energy. Renewable energy needs to be developed in terms of responding to climate change, and the recent Paris agreement is also emphasizing the importance of renewable energy. In particular, renewable energy needs to be widely disseminated. And renewable energy is limited space. In this regard, idle land can provide opportunities for securing new renewable energy generation facilities. The introduction of new and renewable energy facilities in idle space can enhance the self-sufficiency rate of the local community, which is significant in terms of responding to climate. In this study, to investigate the possibility of utilizing a unused space for a photovoltaic power generation facility, we investigated the amount of electricity which could be generated through photovoltaic power generation, and the economic effects, using a RETScreen model. The results showed that 9,738 MWh of power can be generated and that $4,540tCO_2eqcan$ be saved. Regarding the economic effect, the net present value of the facility was shown to be 2,247,389,020 KRW. As the net present value was shown to be positive, we believe that the installation of a photovoltaic power generation facility in an unused space would have a positive economic effect. We found the net present value following the fluctuation of the SMP price to be positive, though there was some variation. However, as the economic efficiency was shown to be low because the net present value in relation to the maintenance costs was negative, we believe that maintenance costs must be taken fully into account when evaluating economic efficiency. In particular, as subsidies can be used to cover maintenance costs which must be factored into photovoltaic power generation, we believe that photovoltaic power generation can have an economic effect. Because spaces not currently in use can have a positive economic effect as renewable energy power generation facilities, and can also contribute to the reduction of greenhouse gas emissions, unused spaces are thought to greatly help local governments to cope with climate change as well as reinforcing their related capabilities. We believe our study will help local governments with decisions relating to unused real estate utilization in the future.

A Study on Remodeling Method of Library Architecture (도서관건축의 리모델링 수법)

  • Lee, Ji-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.24 no.1
    • /
    • pp.3-10
    • /
    • 2017
  • This study is to analyze the remodeling method of library in terms of space extension method and urban regeneration by repurposing function in unused facilities through case study. In many case of library extension, horizontal extensions are more frequent than vertical extensions, because there are limits to extend vertically due to high live load estimation by book stacks. Extension schemes was organized by new building extension method in connection with existing buildings, attaching method small scaled mass or linear mass to existing building, connecting method a plurality of existing small buildings, vertical extension method on the top of the structure, underground extension method using special structure. Unused facility remodeling to the library, large scaled buildings can be developed completely to the function of the library through the relocation of the space, while small scaled building needs spatial extension. In the case of spatial extension, existing space that was used for other purposes can be used as a reading room or office, avoiding high live load estimation.

A study on Facade Design Components of Unused Industrial Facilities Based on Application Methods for Revitalization Design - Concentrated on Exhibition Space in China - (재생디자인 활용방법을 바탕으로 한 유휴 산업시설의 파사드 디자인 구성요소에 관한 연구 - 중국 전시공간을 중심으로 -)

  • Bi, Likai;Kim, Dongsik
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.1
    • /
    • pp.117-131
    • /
    • 2018
  • Due to the paradigm shift of the industrial structure in the contemporary china society, the usage of practical function of industrial facilities goes down in this high developing society, so that it falls into some unused spaces. But the unused industrial facilities that including historical, symbolic and cultural meaning has been creating a new cultural space by giving architectural form and function through a variety of application methods for revitalization design. Especially, the facade design which fully expresses the function and meaning of building while properly expressing the cultural situation. It improves the living and cultural conditions of residents while giving the new symbolism of unused industrial facilities through various ways of application methods for revitalization. The unused industrial facilities that was reconstructed into the exhibition space in Beijing and Shanghai, china since 2006 is the object and scope of this study. The purpose of this study is to analyze the methods and characteristics of application methods for revitalization according to each component of the facade design in the idle industrial facility and to expect it to become basic data in the future design plan of unused industrial facilities.

A study on the application and construction of a rainwater storage tank in apartment complex (공동주택단지에서의 빗물저수조 설치 및 활용방안 연구)

  • Lee, Won-Yeul;Jeong, Sang-Min;Shin, Duck;Lee, Chuel-Hun;Han, Moo-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.4 s.18
    • /
    • pp.165-171
    • /
    • 2005
  • Nowadays, a source of all water, which has been spent by a lot of people, is the rainwater The rainwater is directly relating human being' life. According to how to use rainwater. human being' life is abundant or poor. Due to the lack of underground filtration quantity, the water circulation of the city is discontinued and the underground ecosystem is destroyed. This study suggest that the unused underground space of building and temporary structure can be used into rainwater storage tank in the facility to use rainwater. Moreover, in this study, while the building is constructed, It is showed that the water used in construction can be replaced in the rainwater.

Effects of Pipe Network Materials and Distance on Unused Energy Source System Performance for Large-scale Horticulture Facilities (배관 재질 및 길이에 따른 대규모 시설원예단지용 미활용 에너지 시스템의 성능 평가)

  • Lee, Jae-Ho;Yoon, Yeo-Beom;Hyun, In-Tak;Lee, Kwang Ho
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.119-125
    • /
    • 2014
  • This study investigated the effects of pipe network materials and distance on system performance utilizing unused energy sources in large-scale horticulture facility. For this, the modeling was performed with a 100 m long and 100 m wide rectangular shaped glass house having an area of 1ha ($10,000m^2$) using EnergyPlus software. The heat sources considered were air source, geothermal heat, power plant waste heat, sea water heat, and river water. The temperature variation of the fluid with regard to pipe material and distance from the heat source and the resultant heat pump electricity consumptions were calculated. It turned out that the fluid temperature reaching the heat pump increased as the distance from the heat source increased in case of sea water and river water, which have higher temperatures than the surrounding soil, improving the heat pump efficiency. It was vice versa in case of the power plant waste heat. In addition, pipe material of PVC showed the smallest effect on the system performance variation due to the lowest thermal conductivity, compared to PB and HDPE.

High-efficiency Agricultural Heater and Smart Control System Utilizing Heat Pipe (히트파이프를 활용한 농업용 고효율난방기 및 스마트 제어시스템)

  • Kim, Eung-Kon;Lim, Chang-Gyoon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1151-1158
    • /
    • 2017
  • The Effluent Heat Pipe integral with the heater is a device that recreates unused thermal energy from the plant in winter, and thus reuses unused energy before releasing the exhaust heat. Through the establishment of facility horticulture and glass greenhouses, we identified the problems of our agricultural heaters, and we proposed efficient agricultural efficiency and smart control systems for optimum agricultural efficiency and smart house.

A Study on Unused Energy Management of Jeju City Waste Environment Center (제주시 폐기물환경사업소의 미활용에너지 활용방안 연구)

  • Kim, S.H.;Kwon, K.R.;Park, Y.C.
    • Journal of Power System Engineering
    • /
    • v.8 no.1
    • /
    • pp.48-54
    • /
    • 2004
  • In this study, waste heat of Jeju City Waste Environment Center is investigated and the utilization method is suggested with economical analysis of additional investment that needed for new facility. Energy balance of the typical facilities is considered in this study such as incineration plant and LFG power plant. The payback period of the investment which is used for the LFG power plant waste heat utilization facility is about 2.4 years and the economic profit of the facility during 10 years operation is up to 926 million won.

  • PDF

The Design and Implementation of Subscriber Information Management System (가입자시설 종합관리시스템(SIMS) 설계 및 구현)

  • Kim, Jang-Su
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.1 no.2 s.2
    • /
    • pp.131-141
    • /
    • 1993
  • This paper describes the development of SIMS. SIMS provides not only the basic functions, such as input and output of outside plant maps and facility status statistics report, which are the major function of TOMS, but also can manage outside plant facilities and subscriber information integrately to maximize the efficiency of large outside plant facility database and to increase the qualify of subscriber service. SIMS provides following functions: Work order generation for telephone installation; Automatic cable pair assignment; Cable tracing and unused pair management; Subscriber record management and statistics report generation; Subscriber address information management.

  • PDF