• Title/Summary/Keyword: Unit type

Search Result 3,376, Processing Time 0.028 seconds

Analysis on the Effect of Local Climate on the Unit-type Ground Heat Exchanger (지역 기후가 유닛형 지중열교환기 성능에 미치는 영향)

  • Bae, Sangmu;Kim, Jae-Min;Nam, Yujin
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.1
    • /
    • pp.67-76
    • /
    • 2019
  • A ground source heat pump (GSHP) system can stable system operation by using underground heat source and has high reliability for energy production. However, wide-spread of the GSHP system is delayed to high initial investment costs. In previous studies, horizontal and unit-type ground heat exchanger (GHX) have developed to overcome disadvantages such as high initial cost. However, these performances of GHXs are greatly influenced by climate and weather conditions. It is necessary to analyze the performance of GHX according to the ground temperature change in the installation site. In this study, the ground temperature of each installation site confirmed and performance of unit-type GHX quantitatively analyzed by numerical analysis. As the result, the performance of the unit type GHX was 33.9 W/m in Seoul, 34.2 W/m in Daejeon, and 37.2 W/m in Busan.The result showed the difference performance of GHX according to local climate was maximum of 9.7%.

Macro-level Methodology for Estimating Carbon Emissions, Energy Use, and Cost by Road Type and Road Life Cycle (도로 종류와 도로생애주기별 탄소배출량, 에너지소모량 및 비용에 대한 거시적 분석방법)

  • Hu, Hyejung;Baek, Jongdae
    • International Journal of Highway Engineering
    • /
    • v.17 no.2
    • /
    • pp.143-150
    • /
    • 2015
  • PURPOSES : The authors set out to estimate the related carbon emissions, energy use, and costs of the national freeways and highways in Korea. To achieve this goal, a macro-level methodology for estimating those amounts by road type, road structure type, and road life cycle was developed. METHODS : The carbon emissions, energy use, and costs associated with roads vary according to the road type, road structure type, and road life cycle. Therefore, in this study, the road type, road structure type, and road life cycle were classified into two or three categories based on criteria determined by the authors. The unit amounts of carbon emissions and energy use per unit road length by classification were estimated using data gathered from actual road samples. The unit amounts of cost per unit road length by classification were acquired from the standard cost values provided in the 2013 road business manual. The total carbon emissions, energy use, and cost of the national freeways and highways were calculated by multiplying the road length by the corresponding unit amounts. RESULTS: The total carbon emissions, energy use, and costs associated with the national freeways and highways in Korea were estimated by applying the estimated unit amounts and the developed method. CONCLUSIONS: The developed method can be employed in the road planning and design stage when decision makers need to consider the impact of road construction from an environmental and economic point of view.

NEW CHARACTERIZATIONS OF COMPOSITION OPERATORS BETWEEN BLOCH TYPE SPACES IN THE UNIT BALL

  • Fang, Zhong-Shan;Zhou, Ze-Hua
    • Bulletin of the Korean Mathematical Society
    • /
    • v.52 no.3
    • /
    • pp.751-759
    • /
    • 2015
  • In this paper, we give new characterizations of the boundedness and compactness of composition operators $C_{\varphi}$ between Bloch type spaces in the unit ball $\mathbb{B}^n$, in terms of the power of the components of ${\varphi}$, where ${\varphi}$ is a holomorphic self-map of $\mathbb{B}^n$.

Electric Furnace Sysetem development of Batch Type Back Light Glass Unit (Batch Type Back Light Glass Unit 소성 봉착 시스템 개발)

  • Kim, Soo-Yong;Lee, Oh-Keol;Kim, Sang-Hyo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1798-1800
    • /
    • 2001
  • As a batch Type device, this machine is contrive to seal glass plates for plasma BLU (Back Light Unit) by indirect heating from electric heaters. In order to maintain the heating / cooling Chambers clean, this machine uses a muffle formation. The components of the machine are listed bellow.

  • PDF

Modified Design of Floating Type Photovoltaic Energy Generation System (부유식 태양광 에너지 발전시설의 수정설계)

  • Lee, Young-Geun;Joo, Hyung-Joong;Nam, Jeong-Hun;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.1 no.4
    • /
    • pp.18-27
    • /
    • 2010
  • We had designed and constructed floating type photovoltaic energy generation system. In this paper, we present the result of investigations pertaining to the development of links between unit modules of the floating type photovoltaic energy generation system. The link system installed between the unit modules is made of pultruded FRP, tire, and polyethilene synthetic fiber rope. The link system is analized by the finite element method. The floating type photovoltaic energy generation system consisted of unit modules connected by link system is installed successfully at sea site. In addition, we present the modified design of the floating type photovoltaic energy generation system based on the proto type system.

  • PDF

A Study on the Post-Occupancy Evaluation of the Types of the Learning Space Unit in Elementary Schools (열린 학교 단위학습공간의 구성유형별 건물성능평가에 관한 연구 - 대구광역시 소재 초등학교를 대상으로 -)

  • Choi, Jae-Young;Lee, Sang-Hong;Choi, Moo-Hyuck
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.10 no.2
    • /
    • pp.15-22
    • /
    • 2003
  • The purpose of this study is to find problems and to provide architectural design standards of the Learning Space Unit(L.S.U.) in Elementary Schools through the Post-occupancy Evaluation(POE). In this study, we found six major problems of the type of the L.S.U. in elementary schools. More than 50% of users expressed dissatisfactions in these items : size, safety, cooling facility, noise, privacy and primary meaning for its original purpose. After the interrelation-analysis, we checked pros and cons about each forms of L.S.U. It is the result of analysis of the layout method in L.S.U. 1) "$8.4m{\times}8.4m$" classroom unit got the highest positive responses 2) "2-classroom type" and "4-classroom type" got higher score than "3-classroom type" 3) "Whole faced type" 1) made more active Multi-space than "Partial faced type" 4) prefered prepared "Open-classroom" to "Closed-classroom" 5) 'Zoning type between L.S.U.s' couldn't influence to user's responses. Designers can consult those informations when they plan a new, remodeling and additional elementary school.

Performance of CVTs Composed of a Differential Gear Unit and a V-belt Drive (차동기어장치와 V-벨트식 변속기구를 결합한 무단변속기의 성능)

  • 최상훈
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.2
    • /
    • pp.199-208
    • /
    • 2003
  • Continuously variable transmission (CVT) mechanisms considered here combine the functions of a K-H-V type differential gear unit and a V-belt type continuously variable unit (CVU). As combining the functions of a K-H-V type differential gear unit and a V-belt type CVU, 24 different mechanisms are presented. Some useful theoretical formula related to speed ratio, power flow and efficiency are derived and analyzed. These mechanisms have many advantages which are the decrease of CVT size, the increase of overall efficiency, the extension of speed ratio range, and the generation of geared neutral.

A Study on the Characteristics of the Apartment unit Plans According to the Outdoor Adjacency Methods (I) (외기인접방식에 따른 아파트 단위평면 특징에 관한 연구(I))

  • Park Mong-Sub
    • Journal of the Korean housing association
    • /
    • v.16 no.2
    • /
    • pp.19-25
    • /
    • 2005
  • This paper call attention to the characteristics of apartment unit plans as to the outdoor adjacency methods. My arguments will attempt to investigate spatial composition and each room sizes of the unit plans. So far, very little has been done in this direction. I will limits myself to study 573 plans which have been designed from 1996 till 2003. What emerges from this analysis is that these samples divided 3 types derived from the outdoor adjacency methods. Type 1 limits itself to 39 square meters unit plans. Type 2 was distributed from 49 square meters to 200 square meters with the exception of 100-110 square meters. And, type 3 ranges from 59 to 160 square meters. Therefore, it could be profitable each room's environmental condition (daylight, ventilation and etc) and diverse apartment building types to design in extent 49-160 square meters.

Design of LCD Backlight Unit Coupled with Micro Fresnel Lens Array (배열형 소형 프레넬 렌즈가 결합된 LCD 백라이트의 설계)

  • Jeong, Man-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.1-7
    • /
    • 2006
  • A light guided plate coupled with the micro Fresnel lens array(MFTA) is designed to improve the efficiency of the LCD backlight unit. Blazed Frenel lens and binary multi-level Fresnel lens are adapted for the MFLA. This type of MFLA can replace the prism sheet and diffuser sheet which are used for the conventional type of the LCD backlight unit. The luminance and uniformity are calculated to verify the performance of the MFLA type LCD backlight unit.

A Studies on Symmetric Type Multiple Unit Roots Test

  • Yil-Yong;I, Key-I
    • Communications for Statistical Applications and Methods
    • /
    • v.7 no.1
    • /
    • pp.107-118
    • /
    • 2000
  • Due to the close relation between cointegration test and multiple unit roots test multiple unit roots test are greatly studied by many researchers,. In this paper we suggest the symmetric type unit roots test which is an adjusted method of Shin (1999) Also we have a small Monte-Carlo simulation study to compare the power of the statistic developed in this paper with those of Shin (1999) and adjusted Fuller statistic(1996)

  • PDF