• Title/Summary/Keyword: Unit method

Search Result 7,002, Processing Time 0.047 seconds

A Novel Driving Method for Cost Competitive a-Si TFT-LCD

  • Moon, Su-Hwan;Lim, Hong-Youl;Kim, Dae-Kyu;Lee, Min-Kyung;Ko, Kyung-Tai;Lee, Jun-Ho;Yoon, Sung-Hoe;Kim, Byeong-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.470-473
    • /
    • 2009
  • We have developed a novel driving method, Six times Rate Driving(SRD) for the purpose of making cost competitive TFT-LCD. By applying SRD method to an a-Si TFT-LCD, the driving rate was increased six times as it was named but the number of data lines and so its D-Ics were reduced to one sixth of the conventional one which resulted in the cost saving of that much. We also newly designed the gate driver in order to avoid any expansion of the bezel width caused by applying SRD. Our newly developed driving technology, SRD was successfully applied to 7.0-inch WSVGA (1024 ${\times}$ 600) TFT-LCD which can be driven with only one data D-IC and here introduced.

  • PDF

Study on the Application of Modular Technologies to Han-ok (한옥의 모듈러 공법 적용에 관한 연구)

  • Lee, Chang-Jae;Lim, Seok-Ho
    • Journal of the Korean housing association
    • /
    • v.23 no.4
    • /
    • pp.49-57
    • /
    • 2012
  • This study was conducted to apply the modular construction method to Han-ok. The modular method, which is differentiated from the existing one, means a construction method that equipments, windows and interior materials are prefabricated as a six-sided object at a plant and then they are assembled at the least process on the spot. As for the theoretical observation, the theoretical basis to apply the modular method to the modular housing and Hanok was divided into environmental and economic aspect. In order to apply the modular method to Hanok, the unit scale and size were selected and the plane of unit module Hanok was developed. And a standard with regard to the unit combination and material lifting transportation method was set and planned. In addition, through the comparison the unit modular Hanok to the existing Hanok, the difference was analyzed and the strength was identified in terms fo design method, structure, construction method, period and cost. In final, the conclusion, with regard to the economic, technical application in future, was drawn through arranging the study contents. The unit modular Hanok to carry out the high-quality dwelling through construction period reduction, standardized construction materials and improved insulation performance can meet the demands for a paradigm of new construction technology.

A Study on Influencing Factors of Unit-Water Measurement method according to Electrostatic capacity (정전용량에 따른 단위수량 측정기법의 영향인자에 대한 실험적 연구)

  • We, Joon-Woo;Lee, Young-Jin;Kim, Jeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.232-233
    • /
    • 2013
  • The unit-water content in fresh concrete determines consistency, and play an important role in condensing the structure of concrete and enhancing the durability of concrete. The capacitance measurement method measure quickly unit-water content and is the best way to apply to construction site. In this study, the unit-water content of capacitance measurement method is estimated according to types and replacemment ratio of admixture. and the field application of capacitance measurement method is reviewed.

  • PDF

A Usability Evaluation Method Based on the Lostness of Unit Action for Coding Education Software (코딩 교육용 소프트웨어에 대한 단위 행동 손실률 기반의 사용성 평가 방법)

  • Park, Hee Sung;Park, Kwang-Hyun
    • The Journal of Korea Robotics Society
    • /
    • v.10 no.2
    • /
    • pp.96-103
    • /
    • 2015
  • In this paper, we first point out the limitation of the existing methods in usability evaluation, and propose a new method to find tasks and users that can cause problems in the use of software applications. To deal with object-based applications, we define unit actions and divide a given task into the sequence of unit actions. Then, we propose a new measure to calculate the degree of lostness for the unit actions. In several experiments, we show the proposed method can represent the usability well while the previous method has a problem in object-based applications. We also find that the user's evaluation is more related to the proposed method than the previous method based on execution time through correlation analysis.

A Study on the Estimation Methods of Nonpoint Pollutant Unit Load - Focus on Nonpoint Pollutant Unit Load in Paddy Field - (비점오염 발생 원단위 산정방법에 대한 고찰 - 논 비점오염 원단위를 중심으로 -)

  • Choi, DongHo;Choi, Soon-Kun;Kim, Min-Kyeong;Hur, Seung-Oh;Hong, Sung Chang;Yeob, So-Jin;Yoon, KwangSik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.3
    • /
    • pp.15-22
    • /
    • 2019
  • In order to preserve water environment, Total Maximum Daily Load(TMDL) is used to manage the total amount of pollutant from various sources, and the annual average load of source is calculated by the unit load method. Determination of the unit load requires reliable data accumulation and analysis based on a reasonable estimation method. In this study, we propose a revised unit load estimation method by analyzing the unit load calculation procedure of National Institute of Environment Research(NIER) method. Both methods were tested using observed runoff ratio and water quality data of rice paddy fields. The estimated values with the respective NIER and revised NIER methods were highly correlated each other. However, the Event Mean Concentration(EMC) and the runoff ratio considered in the NIER method appeared to be influenced by rainfall classes, and the difference in unit load increases as the runoff and EMC increase. The error can be further increased when the EMC and runoff ratio are changed according to changes in rainfall patterns by climate change and change of agricultural activities. Therefore, it is recommended to calculate unit load by applying the revised NIER method reflecting the non point pollution runoff characteristics for different rainfall classes.

A Proposal of a Power Saving Hydraulic Unit and Controller Design (동력 절약형 유압유니트 제안 및 제어기 설계)

  • Yum, Man-Oh;Lee, Sang-Yun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.1
    • /
    • pp.80-88
    • /
    • 2010
  • In a conventional system, hydraulic unit pumps out pressurized oil when the power use is not even necessary. As a result, it causes much power loss. This study is on the proposal of new hydraulic unit which controls the revolution of the pump in order to produce proper power needed and to have good response characteristic. In addition, the existing control methods such as PID control method, fuzzy control method, and adaptive control method are applied to the proposed hydraulic unit. Then the best control method is selected and the controller is developed to realize minimum power loss.

Extraction of S-Parameters for a Slot Unit on the Post-Wall Waveguide from Measured Data

  • Lee, Jae-Ho;Park, Jung-Yong
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.1
    • /
    • pp.122-127
    • /
    • 2012
  • Post-wall waveguide structures have attracted a great deal of attention for micro- and millimeter-wave applications. One of the waveguide’s applications is a slotted waveguide array. In order to design the slotted array, the characteristics of a slot unit alone on the post-wall waveguide should be investigated. In this paper, a method for extracting the S-parameters of a unit slot is proposed. This simple method requires only two kinds of waveguides: waveguides without a slot unit and waveguides with a slot unit. Three kinds of slot units are fabricated, and the extracted results show a high level of agreement with predicted (simulated) results. With this method, the equivalent slot length can also be found.

A Study on Direct Load Control including Unit Commitment (DLC와 기동정지계획의 연계방법에 관한 연구)

  • Lee, Buhm;Kim, Yong-Ha;Choi, Sang-Kyu;Kim, Hyung-Jung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.713-716
    • /
    • 2001
  • This paper describes Direct load control(DLC) method including unit commitment. To consider the unit commitment on DLC, 3-Dimensional dynamic programming as a new unit commitment method is developed. And, this method is applied to DLC. As result, optimization of operating schedule with DLC is possible. This method is applied to the test system, and usefulness of the method is verified.

  • PDF

Design of a Dispatch Unit & Operand Selection Unit for Improving the SIMT Based GP-GPU Instruction Performance (SIMT구조 GP-GPU의 명령어 처리 성능 향상을 위한 Dispatch Unit과 Operand Selection Unit설계)

  • Kwak, Jae Chang
    • Journal of IKEEE
    • /
    • v.19 no.3
    • /
    • pp.455-459
    • /
    • 2015
  • This paper proposes a dispatch unit of GP-GPU with SIMT architecture to support the acceleration of general-purpose operation as well as graphics processing. If all the information of an operand used instructions issued from the warp scheduler is decoded, an unnecessary operand load occurs, resulting in register loads. To resolve this problem, this paper proposes a method that can reduce the operand load and the load on the resister by decoding only the information of the operand using a pre-decoding method. The operand information from the dispatch unit is passed to the operand selection unit with preventing register bank collisions. Thus the overall performance are improved. In the simulation test, the total clock cycles required by processing 10,000 arbitrary instructions issued from the wrap scheduler using ModelSim SE 10.0b are measured. It shows that the application of the dispatch unit equipped with the pre-decoding function proposed in this paper can make an improvement of about 12% in processing performance compared to the conventional method.

IMPLEMENTATION OF REAL TIME RELP VOCODER ON THE TMS320C25 DSP CHIP

  • Kwon, Kee-Hyeon;Chong, Jong-Wha
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.957-962
    • /
    • 1994
  • Real-time RELP vocoder is implemented on the TMS320C25 DSP chip. The implemented system is IBM-PC add-on board and composed of analog in/out unit, DSP unit, memoy unit, IBM-PC interface unit and its supporting assembly software. Speech analyzer and synthesizer is implimented by DSP assembly software. Speech parameters such as LPC coefficients, base-band residuals, and signal gains is extracted by autocorrelation method and inverse filter and synthesized by spectral folding method and direct form synthesis filter in this board. And then, real-time RELP vocoder with 9.6Kbps is simulated by down-loading method in the DSP program RAM.

  • PDF