• Title/Summary/Keyword: Unit method

Search Result 7,042, Processing Time 0.031 seconds

A Synthesis of Unit Hydrograph by a Correlation Analysis between the Basin Characteristics and the Runoff-Characteristics - Han and Geum River Basin - (유역특성과 유출특성간의 상관관계 해석에 의한 단위유량도의 합성 - 한강 및 금강유역 -)

  • 윤용남;선우중호
    • Water for future
    • /
    • v.8 no.1
    • /
    • pp.61-79
    • /
    • 1975
  • An attempt is made to develope a scheme for synthesizing unit hydrograph for any arbitrary small watershed in the Han or Geum River basin, which can be applied in determining various sizes of design flood for flood control prijects. Stage gauging stations, seven in the Han and five in the Geun River basin with rating curves, were selected as subbasins for the analysis. Unit hydrographs of 2-hour duration were derived for several heavy storm events using the storm and the corresponding flood runoff data for each subbasin. The Clark method programmed by the Hydrologic Engineering Center, U.S. Corps of Engineers, was utilized for derivation of instantaneous unit hydrographs which were, in turn, converted into 2-hour unit hydrograph. By averaging the 2-hour unit hydrographs from several storm events a representative 2-hour unit hydrograph was determined for each subbasin and hence a separate derivation of dimensionless unit hedrograph was also possible for the Han and Geum River basins. The physiographic characteristics such as stream length, distance to the centroid of each watershed were correlated with the characteristic parameters of the derived unit hydrograph for the subbasins within two large basins. correlation analyses between the characteristic parameters were also made. These correlation analyses resulted a series of four equations and a dimensionless unit hydrograph for the two large basins, which made it possible to draw a synthetic 2-hour unitgraph for any small watershed within the Han or Geum River basin. A detailed procedure for aplying the derived method for an arbitrary basin is summarized with one sample computation for each of the two basins. A comparison of the actually derived 2-hour unit hydrogrograph and the synthesized one showed a fair agreement. A recommendation is made for the further study.

  • PDF

A Proposal for Improving the Measurement and Management of Unit Water Content in In-Situ Concrete (현장 타설 콘크리트의 단위수량 측정 및 관리 개선 방안 제시)

  • Yun, Ja-yeon;Jang, Hyo-Jun;Lee, Taegyu;Choi, Hyeonggil
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.3
    • /
    • pp.319-329
    • /
    • 2024
  • This study examined domestic and international regulations concerning concrete unit weight, along with an evaluation of unit weight in concrete poured on construction sites. Fluctuations in unit weight were observed to correlate with concrete quality issues such as material separation, bleeding, and latency. A word cloud analysis, centered on the concept of concrete quality, further highlighted the significant influence of unit weight. Comparative analysis between Korea and Japan revealed few substantial differences in unit weight management and measurement techniques. However, calculation of concrete unit weight at delivery, using the unit volume mass method, indicated considerable variability among random on-site samples. Notably, the unit weight often exceeded the recommended standard. These findings emphasize the necessity for strict adherence to unit weight standards by all stakeholders involved in concrete production and construction, including ready-mix concrete (REMICON) producers, construction firms, and inspectors. To ensure consistent quality of cast concrete on-site, the establishment of a more comprehensive and practical system is recommended, incorporating measures such as on-site inspections.

Largest Coding Unit Level Rate Control Algorithm for Hierarchical Video Coding in HEVC

  • Yoon, Yeo-Jin;Kim, Hoon;Baek, Seung-Jin;Ko, Sung-Jea
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.1 no.3
    • /
    • pp.171-181
    • /
    • 2012
  • In the new video coding standard, called high efficiency video coding (HEVC), the coding unit (CU) is adopted as a basic unit of a coded block structure. Therefore, the rate control (RC) methods of H.264/AVC, whose basic unit is a macroblock, cannot be applied directly to HEVC. This paper proposes the largest CU (LCU) level RC method for hierarchical video coding in a HEVC. In the proposed method, the effective bit allocation is performed first based on the hierarchical structure, and the quantization parameters (QP) are then determined using the Cauchy density based rate-quantization (RQ) model. A novel method based on the linear rate model is introduced to estimate the parameters of the Cauchy density based RQ model precisely. The experimental results show that the proposed RC method not only controls the bitrate accurately, but also generates a constant number of bits per second with less degradation of the decoded picture quality than with the fixed QP coding and latest RC method for HEVC.

  • PDF

Comparison of the unit mass discharge from wastewater treatment facility in the industrial park with the estimation methods (산업단지 폐수발생량 원단위 산정 비교연구)

  • Kim, Joon-Yup;Choi, Kyoung-Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.339-344
    • /
    • 2014
  • The predictive capacity of wastewater treatment facility in the industrial park was estimated by the traditional method and on-the-spot survey such as certification of wastewater report and the invoices of water supply and ground water supply. The ratios of a converted wastewater to supplied industrial water between traditional method and on-the-spot survey in the estimation methods were different. By using traditional method, the business type of clothes, accessary and fur production had 77.18 % of waste ratio of wastewater and $10.72m^3/day{\cdot}1000m^2$ unit mass of wastewater as the highest among 9 business types. With the respect to the on-the-spot survey, food manufacturing business type had 75 % of waste ratio of wastewater and $8.35m^3/day{\cdot}1000m^2$ unit mass of wastewater as the highest values. The amount of wastewater from on-the-spot survey method was 541 $m^3/day$ less than one from traditional method.

Asymmetric Polymerase Chain Reaction-Single-Strand Conformation Polymorphism (Asymmetric PCR-SSCP) as a Simple Method for Allele Typing of HLA-DRB

  • Kang, Joo-Hyun;Kim, Kyeong-Hee;Maeng, Cheol-Young;Kim, Kil-Lyong
    • BMB Reports
    • /
    • v.32 no.6
    • /
    • pp.529-534
    • /
    • 1999
  • Asymmetric PCR and single-strand conformation polymorphism (SSCP) methods were combined to analyze human leukocyte antigen (HLA)-DRB allele polymorphism. Asymmetric PCR amplification was applied to generate single-stranded DNA (ssDNA) using the nonradioactive oligonucleotide primers desinged for the polymorphic exon 2 region. The conformational differences of ssDNAs, depending on the allele type, were analyzed by nondenaturing polyacrylamide gel electrophoresis and visualized by ethidium bromide staining. The ssDNAs were clearly separated from double-stranded DNA without interference and obviously migrated depending on their allele type. This method was applied to the genomic DNA either from homozygous or from heterozygous cell lines containing the DR4 allele as template DNA using DR4-specific primers, and satisfying results were obtained. Compared to the standard PCR-SSCP method, this asymmetric PCR-SSCP method has advantages of increased speed, reproducibility, and convenience. Along with PCR-SSP or sequence-based typing, this method will be useful in routine typing of HLA-DRB allele.

  • PDF

Load Balancing Based on Transform Unit Partition Information for High Efficiency Video Coding Deblocking Filter

  • Ryu, Hochan;Park, Seanae;Ryu, Eun-Kyung;Sim, Donggyu
    • ETRI Journal
    • /
    • v.39 no.3
    • /
    • pp.301-309
    • /
    • 2017
  • In this paper, we propose a parallelization method for a High Efficiency Video Coding (HEVC) deblocking filter with transform unit (TU) split information. HEVC employs a deblocking filter to boost perceptual quality and coding efficiency. The deblocking filter was designed for data-level parallelism. In this paper, we demonstrate a method of distributing equal workloads to all cores or threads by anticipating the deblocking filter complexity based on the coding unit depth and TU split information. We determined that the average time saving of our proposed deblocking filter parallelization method has a speed-up factor that is 2% better than that of the uniformly distributed parallel deblocking filter, and 6% better than that of coding tree unit row distribution parallelism. In addition, we determined that the speed-up factor of our proposed deblocking filter parallelization method, in terms of percentage run-time, is up to 3.1 compared to the run-time of the HEVC test model 12.0 deblocking filter with a sequential implementation.

Unit-Rectangle Exposure Method for Advanced Through-put in Electron-Beam Direct Writing Lithography (전자선 직접묘사에서 Through-put이 향상된 단위 矩形묘사방법)

  • Park, Sun-Woo;Kim, Chul-Ju
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.2
    • /
    • pp.112-117
    • /
    • 1989
  • This paper describes to the unit rectangle EB direct writing lithography method using SEM. This method has the constant exposure time to any rectangle pattern. In order to change the EB current according to various rectangle size for the constant exposure time, the supply current of condenser lens in controlled by BITMAP-IV CAD system. By this method, the resizing procedure of density pattern area is not needed to pattern data conversion, and the through-put ofr exposure is increased about 172 times compared with the unit scan exposure method.

  • PDF

A Study on the Estimation of Motor Unit Information using Surface EMG (표면 근전도를 이용한 운동단위의 정보추정에 관한 연구)

  • Kim, Sung-Hwan;Lee, Ho-Yong;Son, Dong-Il;Jung, Chul-Ki;Ko, Do-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.2040-2050
    • /
    • 2007
  • In this study, we present a novel method for estimating the information of MU(motor unit) which is the basic element of human muscle by using surface EMG. Some of the method developed in this field could only estimate the numbers of MU that is activated. However, in our study the MU-simulator based on the line source model was designed to estimate the MU information including the numbers of MU and muscle fiber, conduction velocity, MU diameter, fiber diameter, and end plate position. The SMUAP(single motor unit action potential) detector was designed and CMAP(compound muscle action potential) by electrical stimulus was recorded. With these data, the MU-simulator can estimate the MU information by varying muscle paramater settings through MSE(mean square error) method. Our results shows that the proposed method can be comparable with the method of anatomical studies. Moreover, our system can be utilized to build a tool for diagnosis and treatment assessment of neuromuscular patients.

A Study on the Plan Formation of University Dormitory's Living Unit by Modular Unit (모듈러 유닛에 의한 대학 기숙사 단위 생활공간의 평면 구성에 대한 고찰)

  • Kim, Jung-Heon;Kim, Jin-Mo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.16 no.2
    • /
    • pp.37-45
    • /
    • 2009
  • The purpose of this study is to suggest the plan formation for university dormitory's living unit by the modular unit of the pre-fabricated architecture, Pursuing this, this study conducts the investigation of present domestic situation of prefabricated construction and practices plan formation for living unit concentrating on the dweller's satisfaction by solving the problems which hitherto constructed dormitory had, especially collapse of dweller's territoriality. Consequently, this study presents the feasibility of modular unit of present prefabricated construction as a new method of dormitory's living unit construction, and suggests the pertinent plan formation for the improvement of the dweller's territoriality.

A Novel Data Transmit Method Using Display Units of Mobile Devices (모바일 단말기의 디스플레이 장치를 이용한 새로운 데이터 전송방법)

  • Shin, Ho-Chul;Cho, Kyu-Min;Oh, Won-Seok;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.193-195
    • /
    • 2004
  • This paper presents a novel data transmit method using display units of mobile devices. Mobile devices such as personal-digital-assistants (PDAs) and cellular phones have a display unit. The typical display unit is a liquid-crystal-display (LCD) with an back-light. Since the proposed data transmit method uses the LCD or back-light as a data transmitter, it is a kind of sightable light communication. Tn order to transmit the data, the display unit drived by an application program on the platform of mobile devices. In this paper, detailed data transmit scheme, specific data protocol are presented and discussed. Finally, with the experimental results, usefulness of the proposed data transmit method is verified.

  • PDF