• 제목/요약/키워드: Unit mass discharge

검색결과 16건 처리시간 0.021초

낙동강 수계에서 제사방적제조 업체에 대한 공정별 원단위산정 및 분석 (Unit Mass Estimation and Analysis from Textile Spinning/Weaving Manufacturing Facility Nearby Nakdong River Basin)

  • 이홍신;손건태;구정은;콘분락사;이홍태;이승환
    • 상하수도학회지
    • /
    • 제22권5호
    • /
    • pp.541-550
    • /
    • 2008
  • In this investigative study, the unit mass discharge for the major water quality parameters such as flowrate, SS, BOD, CODmn, CODcr, TN, TP from textile spinning/weaving industry nearby Nakdong river basin was estimated. To represent the respective industries, three companies from hundreds of textile spinning/weaving industries located in Nakdong river basin was carefully selected based on its manufacturing goods, flowrate and location for the estimation of unit mass discharge based on unit operation and process. There was a drastic decrease of unit mass discharge estimation between influents and effluents of water quality parameters, which represents the removal capacity of wastewater treatment plant. With the advent of new regulation on the imposed payment proportional to the total amount of pollutants discharge into the water body, the concept of cleaner production technology should be employed in the unit operation/process in wastewater treatment plant as well as textile manufacturing procedure to minimize the levy on the pollutants discharge. Unit mass discharge estimations of unit process (estimated in this study) in major water quality parameters (SS, BOD, COD, TN and TP) based on land were similar to those of composite process (estimated by National Institute of Environmental Research). But the unit mass discharge estimations of unit process in BOD and CODmn based on total sale were much higher than those of composite one while in SS, TN and TP similar to each other. For the detailed estimation of the imposed payment, unit mass estimation based on unit process should be further emphasized.

낙동강수계에서 섬유염색 및 가공 업체에 대한 공정별 원단위산정 및 분석 (Unit Mass Estimation and Analysis from Fiber Dyeing and Finishing Facility Nearby Nakdong River Basin)

  • 구정은;나동훈;이승환
    • 대한환경공학회지
    • /
    • 제31권9호
    • /
    • pp.765-774
    • /
    • 2009
  • 섬유염색 및 가공산업은 용수요구량이 매우 높은 편이며 다양한 난분해성 염료의 사용으로 인해 폐수발생량의 기여도가 높은 전형적인 오염 유발 산업이다. 본 연구는 낙동강 수계에서 산업폐수 발생업체 중 섬유염색 및 가공 산업시설을 중심으로 SS, $BOD_5,\;COD_{Mn},\;COD_{Cr}$, TN 그리고 TP와 같은 수질 항목에 대해서 발생원 단위 오염물질 배출 특성을 파악하고 발생원단위 부하량을 산출하기 위해 수행되었다. 각 산업을 대표하는 오염원 발생원단위의 산정을 위해 낙동강 수계에 산재한 섬유염색 및 가공업체 중 세 개 업체를 선정하였다. BOD 기준 유입수와 유출수에서의 원단위 값은 90%이상 감소하였지만 원수에서의 높은 유기물 부하량으로 인해 원단위값 자체는 섬유제조시설에서 얻어진 값과 유사하였다. 유수의 생분해도는 유출수에 비해 세배 가량 높게 나타났다. 건평, 제품생산량 및 원료사용량을 기준으로 한 주요 수질 항목 (SS, $BOD_5$, COD, TN and TP)에서 단위공정(본 연구에서 산정한 값)의 오염원 발생원단위 결과값이 통합공정(국립환 경과학원에서 산정한 값)의 오염원 발생원단위 결과 값과 유사하였지만 다른 인자를 기준으로 한 경우에는 커다란 차이를 보여주었다. 섬유염색 및 가공업체에서 도출된 오염원 발생원단위 인자는 낙동강 수질 오염총량제 도입과 함께 수질오염 부하량 처리비용을 산정 할 때 유용한 자료로 활용될 수 있으리라 기대된다. 이러한 오염원 발생부하량 도출과 함께 낙동강 수계에서의 효과적인 수질오염제어와 관리를 위해서는 각 산업별 폐수처리시설의 유출수로부터 다양한 형태의 수질오염항목을 특성화시킬 필요가 있다.

산업단지 폐수발생량 원단위 산정 비교연구 (Comparison of the unit mass discharge from wastewater treatment facility in the industrial park with the estimation methods)

  • 김준엽;최경식
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.339-344
    • /
    • 2014
  • The predictive capacity of wastewater treatment facility in the industrial park was estimated by the traditional method and on-the-spot survey such as certification of wastewater report and the invoices of water supply and ground water supply. The ratios of a converted wastewater to supplied industrial water between traditional method and on-the-spot survey in the estimation methods were different. By using traditional method, the business type of clothes, accessary and fur production had 77.18 % of waste ratio of wastewater and $10.72m^3/day{\cdot}1000m^2$ unit mass of wastewater as the highest among 9 business types. With the respect to the on-the-spot survey, food manufacturing business type had 75 % of waste ratio of wastewater and $8.35m^3/day{\cdot}1000m^2$ unit mass of wastewater as the highest values. The amount of wastewater from on-the-spot survey method was 541 $m^3/day$ less than one from traditional method.

Characteristics of Pollutant Loading in Namdae-cheon Watershed

  • Choi, Jin-Kyu;Son, Jae-Gwon
    • 한국농공학회지
    • /
    • 제45권7호
    • /
    • pp.49-56
    • /
    • 2003
  • Nonpoint source pollutant loading from watershed may cause a problem to the water quality of the reservoir and stream. The characteristics of stream flow and water quality were monitored to investigate the runoff loading of the Namdae-cheon watershed from May in 1999 to October in 2003. Stage-discharge rating curve at the stream gauging site was established, and annual stream runoff of the study watershed was estimated as 499.4∼1,330.8mm during four years. The concentrations of total-nitrogen and total-phosphorus of stream water quality ranged from 0.76 to 6.95mg/L and from 0.0010 to 0.2276 mg/L, respectively, where T-N was generally higher than the water quality standard 1.0 mg/L for agricultural water use. The loads by unit generation of pollutant mass with respect to population, livestock, land use in this watershed were calculated. The runoff pollutant loadings by concentrations of total-N and total-P were estimated during study period, where the annual runoff loading of total-P was much less than the load by pollutant mass unit generation. The relations between stream discharge and water quality were analysed, and there was a high correlation for total-N but low for total-P. These results will be used to develop the monitoring techniques and water quality management system of agricultural watershed.

복합형 유역모델 STREAM의 개발(II): 모델의 시험 적용 (Development of a Hybrid Watershed Model STREAM: Test Application of the Model)

  • 조홍래;정의상;구본경
    • 한국물환경학회지
    • /
    • 제31권5호
    • /
    • pp.507-522
    • /
    • 2015
  • In this study, some of the model verification results of STREAM (Spatio-Temporal River-basin Ecohydrology Analysis Model), a newly-developed hybrid watershed model, are presented for the runoff processes of nonpoint source pollution. For verification study of STREAM, the model was applied to a test watershed and a sensitivity analysis was also carried out for selected parameters. STREAM was applied to the Mankyung River Watershed to review the applicability of the model in the course of model calibration and validation against the stream flow discharge, suspended sediment discharge and some water quality items (TOC, TN, TP) measured at the watershed outlet. The model setup, simulation and data I/O modules worked as designed and both of the calibration and validation results showed good agreement between the simulated and the measured data sets: NSE over 0.7 and $R^2$ greater than 0.8. The simulation results also include the spatial distribution of runoff processes and watershed mass balance at the watershed scale. Additionally, the irrigation process of the model was examined in detail at reservoirs and paddy fields.

대구획 광역논에서의 오염부하특성과 원단위 (Characteristics and Unit Load of Pollutants at a Paddy Field Area with Large-Scaled Plots)

  • 김규성;김진수;오승영;윤춘경
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.390-393
    • /
    • 2001
  • Mass balance and unit load of pollutants were investigated at paddy field area during irrigation periods in 1999 and 2000. The amounts of irrigation water during irrigation periods were 3,690mm in 1999 and 3,160mm in 2000. The concentration of surface outflow is not so high as that of irrigation because 44% of irrigation water discharge without entering the paddy plots. The unit loads of pollutants during irrigation periods were estimated 19.2kg/ha for T-N, 0.29kg/ha for T-P and 47.5kg/ha for COD.

  • PDF

Demonstration of a Modular Electrostatic Precipitator to Control Particulate Emissions from a Small Municipal Waste Incinerator

  • Intra, Panich;Yawootti, Artit;Tippayawong, Nakorn
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.239-246
    • /
    • 2014
  • Incineration is conceptually sound as a waste treatment technology. There is, however, concern over its emissions when it is improperly designed and operated. An electrostatic precipitator is one of the most commonly used devices to control particulate emissions from boilers, incinerators and some other industrial processes. In this work, a modular electrostatic precipitator with sizing of $1m{\times}1m{\times}1m$ was developed for removal of particulate matter from the exhaust gases of a small waste incinerator. Its design was based on a simple wire-and-plate concept. The corona discharge wires were connected to a positive high-voltage pulse generator, while the collection plates were grounded. The high-voltage pulse generator was used to produce the corona discharge field between the individual discharge wire and the collection plate. The particulate-laden exhaust gas flow was directed across the corona discharge field. The charged particles were deflected outward and collected on the plate. The collection efficiency was evaluated as a mass loading ratio between the difference at the inlet and the outlet to the particulate loading at the inlet of the precipitator. The collection efficiency of this modular electrostatic precipitator design was approximately 80 %.

가변속 왕복동형 압축기 본체의 동적 거동 해석 (Dynamic Behavior Analysis of a Reciprocating Compressor Body with Variable Rotating Speed)

  • 김태종
    • 한국소음진동공학회논문집
    • /
    • 제11권8호
    • /
    • pp.374-383
    • /
    • 2001
  • A reciprocating compressor unit with variable rotating speed driven by BLDC motor is mounted Inside hermetic chamber on an internal suspension composed of 4 roil springs and a discharge pipe. A method for predicting the dynamic behavior of compressor body is required for a reduction of transmitted vibrations. The mechanical characteristics of spring and discharge pipe stiffness properties have been obtained from experimental tests and mass moment of inertia of the compressor body iron CAD. To confirm the vibration model for the compressor body, free vibration analyses are performed with theoretical and experimental methods. results for analytical investigations on the dynamic behavior of the compressor body and the transmitted forces to the hermetic chamber through the suspension elements are Presented.

  • PDF

가변속 왕복동형 압축기 본체의 동적 거동 해석 (Dynamic Behavior Analysis of Reciprocating Compressor Frame with Variable Rotating Speed)

  • 김태종;이상민;박찬수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.362-367
    • /
    • 2001
  • A reciprocating compressor unit with variable rotating speed driven by BLDC motor is mounted inside hermetic chamber on an internal suspension composed of 4 coil springs and a discharge pipe. A method for predicting the dynamic behavior of compressor frame is required to reduce the transmitted vibration level. Mechanical characteristics such as mass, spring and discharge pipe stiffness properties are obtained with experimentation. To confirm the vibration model for compressor frame, free vibration analyses are performed with theoretical and experimental methods. Results for analytical and experimental investigations on dynamic behavior of the compressor frame are presented, and the agreement between measured and predicted results are satisfactory.

  • PDF

관개기 광역논에서의 오염물질의 수지(지역환경 \circled3) (Mass Balance of Pollutants at a Paddy Field Area During Irrigation Period)

  • 오승영;김진수;김규성
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.617-622
    • /
    • 2000
  • Concentration of pollutants and discharge were monitored regularly at paddy field area during irrigation periods. The amounts of irrigation water during irrigation water during irrigation periods in 1999 were 3690mm. The concentration of pollutants in ponded water are high during fertilizer application period. The ratio of discharge of direct runoff Q$\_$D/ to the total runoff is 9%. The ratios of the load of direct runoff L$\_$D/ to the total load L$\_$T/ are 6% for T-N, 16% for T-P and 16% for COD. It was found that the ratios of the concentration are 0.7 for T-N, 1.8 for T-P and 1.9 for COD. The unit load of T-N, T-P and COD during irrigation periods were 12.1kg/㏊, 0.42kg/㏊ and 85.7kg/㏊, respectively

  • PDF