• Title/Summary/Keyword: Unit bias

Search Result 161, Processing Time 0.024 seconds

A Study on the Health Status of Korean Vietnam Veterans' Children - A Result of Questionnaire Survey on Vietnam Veterans of Pusan Area Who Diagnosed as Cases by Korean Veteran's Hospital Diagnostic Criteria - (베트남전 참전자 2세의 건강상태에 관한 조사 - 부산지역 고엽제 위해증 환자를 대상으로 한 설문조사 결과 -)

  • Kim, Hak-Joon;Sohn, Hae-Sook;Urm, Sang-Hwa;Park, Soo-Kyung;Yu, Byung-Chul;Lee, Jong-Tae;Chun, Jin-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.1
    • /
    • pp.17-24
    • /
    • 2000
  • Objectives : To propose the referential data to evaluate the health impacts of Vietnam veterans' children whose father were exposed to herbicides in Vietnam War. Methods : Vietnam veterans who visited to Pusan Veteran Hospital for medical care were recruited from April to October, 1998. They were 71 and asked about their own combat history, symptoms and illness, and health status of their 182 children. The informations were collected by direct and phone interview. Exposure estimation was also performed as exposure score depending on year and unit of participation, and personal episodes related to exposure to herbicide in the war. It classified into three groups; lower(<18.0), moderate(18-53), high$(\geq53)$ exposure group. Results : The mean age and the period into the combat of the veterans were 52.8 years and 15.0 months. The mean exposure score was $18.1{\pm}9.9$, and mainly distributed in lower (46.5%) and moderate(52.1%) exposure group. Most(90.1%) of them were diagnosed as sequelae(21 cases) and suspected sequelae(43 cases) of the herbicides by Korean veteran's hospital diagnostic criteria. The major sequelae was peripheral neuropathy 13 cases, chloracne 5 cases, and the major suspected sequelae was hypertension 20 cases, diabetes mellitus 18 cases, liver disease 12 cases, central neuropathy 11 cases, etc. About birth, 42.2% and 16.9% experienced spontaneous abortion and stillbirth, respectively. The mean exposure score was higher in stillbirth experience group(p<0.05). About half of the children(90 cases, 49.5%) hold the abnormal health status: those were skin pigmentation 38 cases, rash 23 cases, congenital anomaly 15 cases, general weakness 12 cases, purpura 8 cases, visual disturbance 8 cases, etc. These health problems had no association with father's exposure level(p>0.05). Conclusions : These results were depend on their own answers, and expectation for compensation did not excluded, therefore, this study may have limitations: inaccuracy of informations due to recall bias and response bias. Nevertheless, through this study, we could image the fundamental aspect for health impacts of Vietnam veterans' children for preparing the national control program and policy. A large scale epidemiologic study with valid exposure assessment on the health impacts of Vietnam veterans' children is recommneded.

  • PDF

Design & Fabrication of an InGaP/GaAs HBT MMIC Power Amplifier for IMT-2000 Handsets (IMT-2000 단말기용 InGaP/GaAs HBT MMIC 전력증폭기 설계 및 제작)

  • 채규성;김성일;이경호;김창우
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.11A
    • /
    • pp.902-911
    • /
    • 2003
  • Using InGaP/GaAs HBT power cells with a 2.0${\times}$20$\mu\textrm{m}$$^2$ emitter area of a unit HBT, a two stage MMIC power amplifier has been developed for IMT-2000 handsets. An active-bias circuit has been used for temperature compensation and reduction in the idling current. Fitting on measured S-parameters of the HBT cells, circuit elements of HBT's nonlinear equivalent model have been extracted. The matching circuits have been designed basically with the extracted model. A two stage HBT MMIC power amplifier fabricated using ETRI's HBT process. The power amplifier produces an 1-㏈ compressed output power(P$\_$l-㏈/) of 28.4 ㏈m with 31% power added efficiency(PAE) and 23-㏈ power gain at 1.95 GHz in on-wafer measurement. Also, the power amplifier produces a 26 ㏈m output power, 28% PAE and a 22.3-㏈ power gain with a -40 ㏈c ACPR at a 3.84 ㎒ off-center frequency in COB measurement.quency in COB measurement.

AlGaAs/InGaAs/GaAs PHEMT power PHEMT with a 0.2 ${\mu}{\textrm}{m}$ gate length for MIMIC power amplifier. (MIMIC 전력증폭기에 응용 가능한 0.2 ${\mu}{\textrm}{m}$ 이하의 게이트 길이를 갖는 전력용 AlGaAs/InGaAs/GaAs PHEMT)

  • 이응호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4B
    • /
    • pp.365-371
    • /
    • 2002
  • In this paper, the fabricated power PHEMT devices for millimeter-wave that is below a gate-length of 0.2 $\mu\textrm{m}$ using electronic beam lithography technologies, and the DC and frequency characteristics and an output power characteristics were Measured at the various bias conditions. The unit process that is used in PHEMT's manufacture used that low-resistance ohmic contact, air-bridge and back-side lapping process technologies, and so on. The fabricated power PHEMT have an S521 gain of 4 dB and a maximum transconductance(gm) of 317 mS/mm, an unilateral current gain(fT) of 62 GHz, a maximum oscillation frequency(fmax) of 120 GHz at 35 GHz, and a maximum power output(Pmax) of 16 dBm, a power gain(GP) of 4 dB and a drain efficiency(DE) of 35.5 %.

Statistical Errors of Articles Published in the Journal of Oriental Rehabilitation Medicine(I) (한방재활의학과학회지의 통계적 오류에 관한 고찰(I))

  • Park, Tae-Yong;Heo, Tae-Young;Shin, Byung-Cheul
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.4
    • /
    • pp.105-130
    • /
    • 2010
  • Objectives : The purpose of this study was to assess the statistical methods errors used in the journal of Oriental Rehabilitation Medicine(JORM) and to identify the types of errors in statistical analysis. Methods : We reviewed quantitative articles that were published in the JORM from January 2005 through October 2009. Those were not used by statistical analysis such as literature studies, case study, review articles were not included in this analysis. A total of 296 articles was reviewed. We evaluated the adequacy and the validity of the statistical techniques with our checklist established be modified Lee's checklist, and three statistical evaluators assessed together to minimize bias. Results : Of the 222 articles, 213 were used in inferential and descriptive statistics. Of those 80% of articles adopting descriptive and inferential statistics were detected having statistical errors. One articles used 1.7 statistical method unit generally. Most frequently employed statistics were student t-test, one way ANOVA. pearson correlation analysis, Mann-whitney U test, paired t-test, and chi-square test in their order. However, most frequent statistics having errors were similar in order. The most common statistic errors were as follow: 1. absence of normality test, 2. misuse between paired test and unpaired test, 3. wrong choice of repeated measures analysis without consideration of time variables, 4, increase of Type I error by using inappropriate multiple test, 5. inappropriate application of discrete or categorical data instead of continuous data in correlation analysis, 6. poor consideration of basic consumption in chi-square test, 7. confusion between frequency comparison and average comparison, 8. mentioning the statistical technique without using it. Conclusions : We found various mistake or misuses in the applications of statistical methodologies in the articles published in the JORM. Careful consideration of statistical use and review from the specialist of statistics are warranted for improving the quality of JORM.

Association between Praziquantel and Cholangiocarcinoma in Patients Infected with Opisthorchis viverrini: A Systematic Review and Meta-Analysis

  • Kamsa-Ard, Supot;Laopaiboon, Malinee;Luvira, Vor;Bhudhisawasdi, Vajarabhongsa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.7011-7016
    • /
    • 2013
  • Background: The liver fluke, Opisthorchis viverrini, and the associated incidence of subsequent cholangiocarcinoma (CCA) are still a public health problem in Thailand, and praziquantel (PZQ) remains the antihelminthic drug of choice for treatment. Evidence in hamsters shows that repeated infection and PZQ treatments could increase the risk of CCA. However, the existing evidence in humans is inconclusive regarding increased risk of CCA with frequency of PZQ intake. Objectives: To investigate the relationship between number of repeated PZQ treatments and CCA in patients with O viverrini infection. Materials and Methods: The reviewed studies were searched in EMBASE, MEDLINE, ProQuest, PubMed and SCOPUS from inception to October, 2012 using prespecified keywords. The risk of bias (ROB) of included studies was independently assessed by two reviewers using a quality scale from the Newcastle-Ottawa Scale (NOS). Risk effect of PZQ was estimated as a pooled odds ratio (OR) with its 95% confidence interval (95%CI) in the random-effects model using DerSimonian and Laird's estimator. Results: Three studies involving 637 patients were included. Based on the random effects model performed in two included studies of 237 patients, the association between PZQ treatments and CCA was not statistical significant with a pooled OR of 1.8 (95%CI; 0.81 to 4.16). Conclusions: The present systematic review and meta-analysis provides inconclusive evidence of risk effect of PZQ on increasing the risk of CCA and significant methodological limitations. Further research is urgently needed to address the shortcomings found in this review, especially the requirement for histological confirmation.

Estimation of the Gastric Cancer Incidence in Tehran by Two-Source Capture-recapture

  • Aghaei, Abbas;Ahmadi-Jouibari, Toraj;Baiki, Omid;Mosavi-Jarrahi, Alireza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.673-677
    • /
    • 2013
  • Introduction: Capture-recapture methods have been suggested for reducing costs of disease registration as well as reducing bias in incidence estimations. This study aimed to estimate the gastric cancer incidence in the Tehran metropolis population during 2002-2006. Materials and Methods: We investigated new cases of gastric cancer reported by three sources; death certificates, pathology reports, and medical records to Tehran population-based cancer registry during 2002-2006. $G^2$ statistics and the two-source capture-recapture method were used to select the best-fitted log-linear model and to estimate incidence, respectively. EXCEL software version 2007 and SPSS software version 16 were used for this research. Results: The number of reported cases was 4,463, with an average age of 68.5 (${\pm}12.9$) years. We found the model that combined two sources of data including pathology reports and medical records and furthermore complemented by death certificates as the best model. The reported and the estimated incidences were 11.0 and 27.1 per 100,000 respectively. Conclusions: The incidence estimated by two-source capture-recapture method is about three times higher than the incidence reported by the sources under investigation. It is recommended to move towards the implementation of population-based cancer registration using various sources of data collection to achieve more accurate data.

Fabrication Process of Single Flux Quantum ALU by using Nb Trilayer (Nb Trilayer를 사용한 단자속양자 논리연산자의 제작공정)

  • Kang, J.H.;Hong, H.S.;Kim, J.Y.;Jung, K.R.;Lim, H.R.;Park, J.H.;Hahn, T.S.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.181-185
    • /
    • 2007
  • For more than two decades Nb trilayer ($Nb/Al_2O_3/Nb$) process has been serving as the most stable fabrication process of the Josephson junction integrated circuits. Fast development of semiconductor fabrication technology has been possible with the recent advancement of the fabrication equipments. In this work, we took an advantage of advanced fabrication equipments in developing a superconducting Arithmetic Logic Unit (ALU) by using Nb trilayers. The ALU is a core element of a computer processor that performs arithmetic and logic operations on the operands in computer instruction words. We used DC magnetron sputtering technique for metal depositions and RF sputtering technique for $SiO_2$ depositions. Various dry etching techniques were used to define the Josephson junction areas and film pattering processes. Our Nb films were stress free and showed the $T{_c}'s$ of about 9 K. To enhance the step coverage of Nb films we used reverse bias powered DC magnetron sputtering technique. The fabricated 1-bit, 2-bit, and 4-bit ALU circuits were tested at a few kilo-hertz clock frequency as well as a few tens giga-hertz clock frequency, respectively. Our 1-bit ALU operated correctly at up to 40 GHz clock frequency, and the 4-bit ALU operated at up to 5 GHz clock frequency.

  • PDF

Fabrication of New Silicided Si Field Emitter Array with Long Term Stability (실리사이드를 이용한 새로운 고내구성 실리콘 전계방출소자의 제작)

  • Chang, Gee-Keun;Yoon, Jin-Mo;Jeong, Jin-Cheol;Kim, Min-Young
    • Korean Journal of Materials Research
    • /
    • v.10 no.2
    • /
    • pp.124-127
    • /
    • 2000
  • A new triode type Ti-silicided Si FEA(field emitter array) was realized by Ti-silicidation of Ti coated Si FEA and its field emission properties were investigated. In the fabricated device, the field emission properties through the unit pixel with $200{\mu\textrm{m}}{\times}200{$\mu\textrm{m}}$ tip array in the area of $1000{\mu\textrm{m}}{\times}1000{$\mu\textrm{m}}$ were as follows : the turn-on voltage was about 70V under high vacuum condition of $10^8Torr$, and the field emission current and steady state current degradation were about 2nA/tip and 0.3%/min under the bias of $V_A=500V\;and\;V_G=150V$. The low turn-on voltage and the high current stability during long term operation of the Ti silicided Si FEA were due to the thermal and chemical stability and the low work function of silicide layer formed at the surface of Si tip.

  • PDF

Fabrication of New Co-Silicided Si Field Emitter Array with Long Term Stability (Co-실리사이드를 이용한 새로운 고내구성 실리콘 전계방출소자의 제작)

  • Chang, Gee-Keun;Kim, Min-Young;Jeong, Jin-Cheol
    • Korean Journal of Materials Research
    • /
    • v.10 no.4
    • /
    • pp.301-304
    • /
    • 2000
  • A new triode type Co-silicided Si FEA(field emitter array) was realized by Co-silicidation of Co coated Si FEA and its field emission properties were investigated. The field emission properties of the fabricated device through the unit pixel with $45{\times}45$ tip array in the area of $250{\mu\textrm{m}}{\times}250{\mu\textrm{m}}$ under high vacuum condition of $10^{-8}Torr$ were as follows : the turn-on voltage was about 35V and the anode current was about $1.2\mu\textrm{A}(0.6㎁/tip)$ at the bias of $V_A=500V\;and\; V_G=55V$. The fabricated device showed the stable electrical characteristics without degradation of field emission current for the long term operation except for the initial transient state. The low turn-on voltage and the high current stability of the Co-silicided Si FEA were due to the thermal and chemical stability and the low work function of silicide layer formed at the surface of Si tip.

  • PDF

Magnetic Field Sensors using Co-base Amorphous Ribbon (Co계 아몰퍼스리본을 이용한 자계센서)

  • Shin, Kwang-Ho;Park, Kyung-Il;Song, Jae-Yeon;Kim, Young-Hak;SaGong, Geon
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.205-210
    • /
    • 2003
  • To develop the highly sensitive Magneto-Impedance sensor, the amorphous ribbon was micro-processed to meander type sensor pattern, and its external magnetic field dependence of impedance was investigated. The impedance of the pattern had peak value at the magnetic field of 13 Oe and its changing ratio was about 170%. The impedance change per unit magnetic field was about 36% at bias field of 6 Oe, in which the output with high sensitivity and linearity could be obtained. The magnetic field resolution of the sensor module, which consist of the amorphous pattern and driving circuit, was about $10^{-3}$ Oe.