• 제목/요약/키워드: Unit Testing

Search Result 620, Processing Time 0.033 seconds

A study on the testing method of discolored tap water by spectrophotometer (분광측색계에 의한 착색 수돗물 시험방법 연구)

  • Dongheon Kim;Jonggeum Lee;Jiyoon Oh;Gitae Kim;Hangbae Jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.4
    • /
    • pp.187-202
    • /
    • 2023
  • This study focuses on the application of a new measurement method that quantifies the residual color of filtered water using a spectrocolorimeter after filtering the discolored substances. It was confirmed through the color and turbidity cross-test that the discolored substances cannot be measured effectively with the current legal color and turbidity test method. Therefore, the National Institute of Environmental Research's filter testing method, which involves filtering the sample through 0.45 ㎛ filter and visually inspecting the color, was improved. A membrane filter colorimetry (MFC) method was established by measuring the color difference (ΔE*ab(65)) of the filtered filter using a spectrophotometer and expressing it as filter color unit (FCU). Using the MFC method, the FCU for reference materials such as iron and manganese, as well as field samples, was measured. The results showed a high correlation with turbidity, and the color difference patterns varied depending on the type of reference materials and field samples. This indicates that the MFC method is an effective new measurement method of discolored tap water.

Investigation of Pathogenic Microorganism from Saengsik-classes (시판생식의 위해미생물 오염도 조사)

  • Cho, Joon-Il;Park, Yong-Chjun;Ko, Soo-Il;Cheung, Chi-Yeun;Lee, Sun-Mi;Cho, Soo-Yeol;Lee, Kwang-Ho;Lim, Chul-Joo;Kim, Ok-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.3
    • /
    • pp.257-263
    • /
    • 2008
  • As Standards and Specifications of the Saengsik-classes has been established since 2005 by KFDA. The microbial Standards and Specifications of the Saengsik-classes is as follows; no detection in Escherichia coli, colony forming unit less then 1,000/g in Bacillus cereus, colony forming unit less then 100/g in Clostridium perfringens respectively. Contamination levels of Total aerobic bacteria, Escherichia coli, Bacillus cereus and Clostridium perfringens in Saengsik-classes were monitored. Total aerobic bacteria counts in Saengsik-classes was $1{\times}10^1{\sim}5.3{\times}10^7cfu/g$, for Bacillus cereus $1{\times}10^2{\sim}9{\times}10^2cfu/g$, for Clostridium perfringens $1{\times}10^1cfu/g$. Escherichia coli, was not isolated from all Saengsik-classes. Thess results will provide information for introduction of HACCP system to ensure microbial safety of Saengsik-classes.

CRESTIVE-DX: Design and Implementation of Distrusted Concolic Testing Tool for Embedded Software (CRESTIVE-DX: 임베디드 소프트웨어에 대해 테스트케이스 생성을 지원하는 분산 Concolic 테스팅 도구)

  • Leem, Hyerin;Choe, Hansol;Kim, Hyorim;Hong, Shin
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.9 no.8
    • /
    • pp.229-234
    • /
    • 2020
  • This paper presents the design and the implementation of CRESTIVE-DX, a concolic testing tool that distribute the concolic testing process over the embedded target system and the host system for efficient test generation of a target embedded program. CRESTIVE-DX conducts the execution of a target program on the target embedded system to consider possible machine-dependent behaviors of a target program execution, and conducts machine-independent parts, such as search-strategy heuristics, constraint solving, on host systems with high-speed computation unit, and coordinates their concurrent executions. CRESTIVE-DX is implemented by extending an existing concolic testing tool for C programs CREST. We conducted experiments with a test bed that consists of an embedded target system in the Arm Cortex A54 architecture and host systems in the x86-64 architecture. The results of experiments with Unix utility programs Grep, Busybox Awk, and Busybox Ed show that test input generation of CRESTIVE-DX is 1.59 to 2.64 times faster than that of CREST.

Measurement of Cortisol in Human Serum by Isotope Dilution Liquid Chromatography/Mass Spectrometry and a Comparison through a Proficiency Testing

  • Lee, Hwa-Shim;Shin, Hye-Sun;Park, Sang-Ryoul;Park, Chang-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1149-1154
    • /
    • 2010
  • Liquid chromatography/mass spectrometry using isotope dilution method has been established as a primary method for the measurement of cortisol in human serum. Verification of this method was accomplished by the participation in Consultative Committee for Amount of Substance-Metrology in Chemistry (CCQM) pilot study. Two levels of cortisol certified reference materials were prepared and certified by the established method. They were used as sample materials for the proficiency testing. The expanded uncertainty in the measurement of cortisol in human serum was approximately 1.2% at 95% confidence level. The results of the proficiency testing showed a good precision among the participants, but some bias to the certified values. This means that commercial field laboratories should keep traceability chain to SI unit through available reference measurement procedures and/or available reference materials.

A BizUnit Test Code Generation for Framework-based Web Application (프레임워크기반 웹 어플리케이션을 위한 BizUnit 테스트 코드 생성)

  • Lee, Eun-Young;Choi, Byoung-Ju;Song, Hwa-Jung;Hwang, Sang-Cheol
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.12
    • /
    • pp.899-912
    • /
    • 2009
  • With greater utilization of web application and growth of its market, the function of such application is being expanded With today's increasing demand for high quality software, we see a sharp rise in the interest for web application test. The current trend is that web applications are being developed based on a framework of developmental environment. Hence, as the scope of that framework expands, each module of the entire web application is being configured by the combination of heterogeneous files. The distinctive characteristics of a web application are based on the fact that the framework that is provided in partially completed form controls the structure of all objects of development. The present study defines the web business logic as a minimal unit which has meaning as a unit of application for the web application. In this paper, we define web business logic as a least meaningful execution unit of web applications, propose how to generate automatically the BizUnit test code for it, and analyze the effectiveness of testing of the web application via the BizUnit test codes.

The Study on The Production Testing Equipment for the Improvement of System Test Reliability in FCS (사격통제장치 시스템 시험의 신뢰성 향상을 위한 생산시험장비에 관한 연구)

  • Choi, Kyungjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.139-147
    • /
    • 2016
  • This study described the design scheme for each step of the production test for the Fire Control System(FCS) of the K-55A1 PIP business of Hanwha Thales since 2011. From the time of receipt of the product It is necessary to improve the FCS's reliability by using the Unit Test, burn-In test, System Test. FCS of K-55A1 acts as a 'head' that control the self-propelled howitzer, and connected with the electrical and physical connection of self-propelled howitzer's multiple unit (Inertial navigation systems(IN), Muzzle Velocity Radar (MVR)) for the normal operation without an inch of error in operating. We designed the production testing equipment automatically as much as possible and designed with the environment similar to the self-propelled howitzer. by using this production testing equipment, It should help for the strengthen national defense of the Republic of Korea.

The Effects of ICT Teaching Method on Interest in Home Economics, Consciousness on Traditional Culture, Achievement Test, and Performance Assessment in High School Borne Economics Instruction (한국 가정생활 문화 관련 단원의 학습에서 ICT활용 수업이 가정교과에 대한 흥미, 전통문화의식, 학업성취 및 수행평가 미치는 효과)

  • 하영희;유태명
    • Journal of the Korean Home Economics Association
    • /
    • v.41 no.11
    • /
    • pp.135-150
    • /
    • 2003
  • This research was to verity the effects of ICT teaching method in high school home economics. The research questions for this study were as follows: 1. Is the ICT teaching method effective in increasing students' interest in home economics and consciousness on traditional culture in teaming the unit of ‘Korean traditional culture of home life’? 2. Is the ICT teaching method effective in improving students' achievement test and performance assessment in teaming the unit of ‘Korean traditional culture of home life’? This study is carried out with following procedure: developing the homepage and lesson plans for ICT teaching, constructing questionnaire, and testing its reliability, pre-testing, treatment for 8 weeks, and post-testing. Two groups were arranged for 8 weeks experiment from May 7,2001 through June 30,2001. Sixteen hours of ICT teaching and 8 hours of traditional lecture for experiment group whereas 8 hours of ICT teaching and 16 hours of traditional lecture for comparison group were input. SAS program was used for statistical analysis, and independent sample t-test and matched pairs t-test were peformed for answering research questions. The results of this study were as following: 1. Sixteen hours of ICT teaching and 8 hours of traditional lecture for experiment group was effective in increasing consciousness on traditional culture and performance assessment. 2. Eight hours of ICT teaching and 16 hours of traditional lecture for comparison group was not effective in learning home economics. This means that at least 2 hours of ICT teaching is demanding for effective learning. This study concluded that ICT teaching will be effectively applied in high school home economic with well developed ICT teaching materials. And home economics educators should continuously put effort in developing curricular, teaching materials, and teaching methods to raise students' interest in home economics.

Development and Evaluation of a Nursing Handoff Protocol for Intensive Care Units (중환자실 간호 인수인계 프로토콜의 개발 및 평가)

  • Cho, Young Shin;Kwon, Sun Ju;Yun, Mi Young;Lee, Mi Hwa;An, So Hee;Kong, Yu Jeong
    • Journal of Korean Critical Care Nursing
    • /
    • v.9 no.2
    • /
    • pp.1-12
    • /
    • 2016
  • Purpose: This study aimed to develop a nursing handoff protocol for intensive care units and test its relevance. Methods: This is a methodological research to develop a protocol. A preliminary protocol was developed by composing items and testing content validity through literature review and experts' review. We revised and complemented the preliminary protocol following practical relevance assessment of 38 intensive care unit nurses at a university hospital to test content validity and to assess practical relevance of the final protocol. Results: On the basis of the content validity test for the final protocol, 40 items were adopted. The scores for the practical relevance of the final protocol increased significantly for items such as accuracy of handoff, reduction of handoff-related errors, convenience in using the protocol, reduction in handoff time, and simplification of handoff. Conclusions: The nursing handoff protocol for intensive care units in this study is expected to improve nursing performance with a standardized handoff in intensive care units, promote patient safety, and improve communication among the medical staff.

  • PDF

Reliability of the Active Knee Extension Test With a Pressure Biofeedback Unit

  • Kim, Chang-ho;Gwak, Gyeong-tae;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.24 no.3
    • /
    • pp.40-46
    • /
    • 2017
  • Background: The active knee extension (AKE) test commonly used to assess the flexibility of the hamstring muscles. Many researchers have tested the reliability of the AKE test; however, no published studies have examined the intrarater and interrater reliability of the AKE test using a PBU. Objects: The purpose of this study was to determine the intrarater and interrater reliability of the AKE test performed with a pressure biofeedback unit (PBU) on healthy subjects. Methods: Sixteen healthy male participants volunteered and gave informed consent to participate in this study. Two raters conducted AKE tests independently with a PBU. Each knee was measured twice, and the AKE testing was repeated one week after the first round of testing. Results: The interrater reliability's intraclass correlation coefficients ($ICC_{2,1}$) were .887~.986 for the right knees and .915~.988 for the left knees. In addition, the intrarater (test-retest) reliability ($ICC_{3,1}$) values ranged between .820~.915 and .820~.884 for Raters 1 and 2, respectively. The values for the standard error of mesurement were low for all tests ($.81{\sim}2.97^{\circ}$); the calculated minimum detectable change was $2.24{\sim}8.21^{\circ}$. Conclusion: These findings suggest that the AKE test performed with a PBU had excellent interrater and intrarater reliability for assessing hamstring flexibility in healthy young males.

Moire-Fringe-Based Fiber Optic Tiltmeter for Structural Health Monitoring (구조물 건전성 감시를 위한 무아레식 광섬유 경사계 센서 개발)

  • Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.157-163
    • /
    • 2008
  • This paper presents a novel fiber optic tiltmeter system for the health monitoring of large-size structures. The system is composed of a sensor head, a light control unit and a signal processing unit. The sensing mechanism of the sensor head is based on a novel integration of the moire fringe phenomenon with fiber optics to achieve a robust performance in addition to its immunity to EM interference, easy ratting, and low cost. In this paper, a prototype of the fiber optic tiltmeter system has been developed successfully. A low-cost light control unit has been developed to drive the system's optic and electronic components. From an experimental test, the fiber optic tiltmeter is proven to be a prospective sensor for the monitoring of the tilting angle of civil structure with a good linearity. Finally, the test also successfully demonstrates the performance and the potential of the novel fiber optic tiltmeter system to monitor the health of civil infrastructures.