• 제목/요약/키워드: Unit System

검색결과 8,864건 처리시간 0.032초

NIC 간호중재 분류체계를 이용한 간호중재분석;정형외과 간호단위를 중심으로 (Analysis of the Nursing Interventions performed by orthopedic surgery care unit using NIC)

  • 권미숙;박경숙
    • 간호행정학회지
    • /
    • 제8권4호
    • /
    • pp.655-667
    • /
    • 2002
  • Purpose : This study analysis of nursing interventions and core nursing interventions performed orthopedic surgery care unit. Method : The data were collected from 55 nurses of 4 general hospital from July. 10, 2002 to Aug. 30, 2002. The instrument for this study was the Korean translation of 486 nursing intervention classifications developed by McColskey & Bulechek in 2000. In the 486 nursing interventions 350 nursing interventions were selected 8 among the 10 more than 5 years working group in orthopedic surgery care unit. Self frequency checking performed by 350 nursing interventions were used secondary questionnaire In the orthopedic surgery care unit nurses. Results : 1. The most frequently used nursing interventions domains were "Physiological : basic" and then "Physiological: complex", "Health system" "Behavior", "Family", "Safety". 2. Orthopedic surgery care unit core nursing interventions were performed several times a day by 50% or more of orthopedic surgery care unit and this result were 4 of domain, 11 of class, 26 core nursing interventions. This core nursing interventions were 5 of "Physiological : basic", 17 of "Physiological: complex", 1 of "Safety", 3 of "Health system" and have no "Behavior", "Family". Conclusion : This study analyzed nursing intervention of orthopedics and reestablished nursing intervention concept and I hope this study will be helpful for the nurse to be a professional by applying this to actual clinic, for development in qualified nursing and for establishment nursing information system.

  • PDF

정밀나사 비전검사시스템용 자동공급장치 진동특성의 해석 (Vibration Analysis for a Feeding Unit of Vision Inspection System of Precision Screws)

  • 서예린;박근;김성걸;나승우
    • 한국생산제조학회지
    • /
    • 제20권4호
    • /
    • pp.446-451
    • /
    • 2011
  • Recent trends for the miniaturization and weight reduction of portable electronic parts have driven uses of subminiature components. Assembly of the miniaturized components requires subminiature screws of which pitch sizes are micrometer scale. To produce such subminiature screws with high precision threads, not only a precision forming technology but also a high-precision measurement technology is required. The present study covers the development of a vision inspection system for precision screws for the automatic measurement of subminiature screws with high speed and reliability. In this study, the feeding unit that transfers the subminiature screws to the inspection unit is investigated through finite element(FE) analysis. The vibration characteristics of the feeding unit are predicted through FE analyses, from which we can determine whether the subminiature screw can be stably fed into the inspection unit or not. The effects of several design parameters on the vibration characteristics are also discussed.

장력안정트러스 구조물의 안정화를 위한 매개변수의 범위 결정에 관한 연구 (Determination of the Boundary of Parameters for Stabilization of Truss Structures Stabilized by Cable Tension)

  • 권택진;한상을;최옥훈
    • 전산구조공학
    • /
    • 제10권3호
    • /
    • pp.195-202
    • /
    • 1997
  • 최근, 텐세그러티(tensegrity)구조개념을 적용한 대공간구조시스템인 케이블돔구조는 구조물 전체의 관점에서는 하나의 자기평형상태를 만족하는 구조로서 돔과 같이 닫힌형상(closed form)의 구조에는 유리한 구조시스템이지만, 보울트(vault)와 같은 열린형상(openform)의 구조에는 적용상 문제가 있다. 따라서, 본 논문에서는 이 문제를 해결하는 방안중의 하나로서, <안정화된 단위요소>를 이용하여 장력안정트러스의 기본요소인 단위구조의 안정화를 지배하는 기하학적 매개변수들의 범위를 설정하는 방법이 제안되고 그 변수들의 상호관련성을 규명하고자 한다. 수치해석은, .alpha.가 안정화범위에 있을 경우, 여러가지 경우의 높이에 따른 중심위치(.alpha.), 트러스 부재에 의한 각(.theta.) 그리고 평면상의 비(x/y)와 같은 매개변수의 변화에 따라 안정화에 가장 지배적인 축력모드(N/sub 15/, N/sub 16/, N/sub 25/, N/sub 26/)들의 상호작용이 조사되었다.

  • PDF

임대아파트 난방방식별 에너지소비와 만족도 조사에 관한 연구 (A Study on the Energy Consumption and the Degree of Satisfaction by Heating System in Rental Apartment)

  • 박민용;장승재
    • 한국주거학회논문집
    • /
    • 제14권3호
    • /
    • pp.85-92
    • /
    • 2003
  • Considering the present development situation of rental apartment since 1982, the supply of homeless housing for low-income dwellers has contributed a amount of quantities, but has been deficient qualities in housing policy. To propose the energy policy for low-income dwellers, this study investigated the energy consumption and the degree of heating satisfaction by heating system through questionaries in permanent rental apartment and 50 year period rental apartment complexes. The results of this study were as follows; The annual energy consumption of heating and hot water supply is 267.2 Mca1/$\textrm{m}^2$ㆍyr in central heating system, is 163.9 Mca1/$\textrm{m}^2$ㆍyr in unit heating system. But from the view of annual energy cost and the degree of heating satisfaction, central heating system were better than unit heating system in rental apartment.

Development of a Microcontroller-based Brushless DC Motor Control System for an Total aAtificial Heart

  • Choi, Won-Woo;Park, Seong-Keun;Choi, Jae-Soon;Min, Byoung-Goo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.509-513
    • /
    • 1995
  • A microcontroller-based DC motor control system for a total artificial heart(TAH) was developed. Using a one-chip microcontroller, 87Cl96KB, the design of digital motor speed control system and servo control system is demonstrated. Functionally, the control system consists of a position control unit, a speed control unit, and a communication unit. The performance and the reliability of the developed control system were assessed through a series of mock circulation system experiments.

  • PDF

평면 공작물 진직도 측정 시스템 개발에 관한 연구 (Development of Straightness Measurement System thor Flat Workpieces)

  • 김현수;장문주;홍성욱;박천홍
    • 한국정밀공학회지
    • /
    • 제19권3호
    • /
    • pp.107-113
    • /
    • 2002
  • This paper presents a straightness measurement system for flat and long workpieces. The measurement system consists of a laser, a CCD camera and processing system, a carrier system with a stylus, and some optical units. The carrier system accompanies the stylus, which displaces and retroreflector along the surface profile. The optical unit is used to optically amplify displacement of the stylus unit. The developed system is applied to a ground surface and a LM guide unit. The experimental results show that the developed system can measure the straightness of flat surface and moving systems.

Stochastic analysis of a non-identical two-unit parallel system with common-cause failure, critical human error, non-critical human error, preventive maintenance and two type of repair

  • El-Sherbeny, M.S.
    • International Journal of Reliability and Applications
    • /
    • 제11권2호
    • /
    • pp.123-138
    • /
    • 2010
  • This paper investigates a mathematical model of a system composed of two non-identical unit parallel system with common-cause failure, critical human error, non-critical human error, preventive maintenance and two type of repair, i.e. cheaper and costlier. This system goes for preventive maintenance at random epochs. We assume that the failure, repair and maintenance times are independent random variables. The failure rates, repair rates and preventive maintenance rate are constant for each unit. The system is analyzed by using the graphical evaluation and review technique (GERT) to obtain various related measures and we study the effect of the preventive maintenance preventive maintenance on the system performance. Certain important results have been derived as special cases. The plots for the mean time to system failure and the steady-state availability A(${\infty}$) of the system are drawn for different parametric values.

  • PDF

열회수장치의 열교환 파이프배치형식별 열교환 성능 비교(II) (Comparision of Heat Exchanging Performance Depending on Different Arrangement of Heat Exchanging Pipe (II))

  • 서원명;강종국;윤용철;김정섭
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.281-285
    • /
    • 2001
  • This study was carried out to improve the performance of heat recovery device attached to exhaust gas flue connected to combustion chamber of greenhouse heating system. Three different units were prepared for the comparison of heat recovery performance; AB-type(control unit) is exactly the same with the typical one fabricated for previous study of analyzing heat recovery performance in greenhouse heating system, other two types(C-type and D-type) modified from the control unit are different in the aspects of airflow direction(U-turn airflow) and pipe arrangement. The results are summarized as follows; 1. In the case of Type-AB, when considering the initial cost and current electricity fee required for system operation, it is expected that one or two years at most would be enough to return the whole cost invested. 2. Type-C and Type-D, basically different with Type-AB in the aspect of airflow pattern, are not sensitive to the change of blower capacity with higher than $25\;m^{3}/min$. Therefore, heat recovery performance was not improved so significantly with the increment of blower capacity. This is assumed to be that air flow resistance in high air capacity reduces the heat exchange rate as well. Never the less, compared with control unit, resultant heat recovery rate in Type-C and Type-D were improved by about 5% and 13%, respectively. 3. Desirable blower capacity for these heat recovery units experimented are expected to be about $25\;m^{3}/min$, and at the proper blower capacity, U-turn airflow units showed better heat recovery performance than control unit. But, without regard to the type of heat recovery unit, it is recommended that comprehensive consideration of system's physical factors such as pipe arrangement density, unit pipe length and pipe thickness, etc., are required for the optimization of heat recovery system in the aspects of not only energy conservation but economic system design.

  • PDF

Stratifying Patients with Haematuria into High or Low Risk Groups for Bladder Cancer: a Novel Clinical Scoring System

  • Tan, Guan Hee;Shah, Shamsul Azhar;Ann, Ho Sue;Hemdan, Siti Nurhafizah;Shen, Lim Chun;Abdul Galib, Nurudin Al-Fahmi;Singam, Praveen;Kong, Ho Chee Christopher;Hong, Goh Eng;Bahadzor, Badrulhisham;Zainuddin, Zulkifli Md
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권11호
    • /
    • pp.6327-6330
    • /
    • 2013
  • Haematuria is a common presentation of bladder cancer and requires a full urologic evaluation. This study aimed to develop a scoring system capable of stratifying patients with haematuria into high or low risk groups for having bladder cancer to help clinicians decide which patients need more urgent assessment. This cross-sectional study included all adult patients referred for haematuria and subsequently undergoing full urological evaluation in the years 2001 to 2011. Risk factors with strong association with bladder cancer in the study population were used to design the scoring system. Accuracy was determined by the area under the receiver operating characteristic (ROC) curve. A total of 325 patients with haematuria were included, out of which 70 (21.5%) were diagnosed to have bladder cancer. Significant risk factors associated with bladder cancer were male gender, a history of cigarette smoking and the presence of gross haematuria. A scoring system using 4 clinical parameters as variables was created. The scores ranged between 6 to 14, and a score of 10 and above indicated high risk for having bladder cancer. It was found to have good accuracy with an area under the ROC curve of 80.4%, while the sensitivity and specificity were 90.0% and 55.7%, respectively. The scoring system designed in this study has the potential to help clinicians stratify patients who present with haematuria into high or low r isk for having bladder cancer. This will enable high-risk patients to undergo urologic assessment earlier.

환기시스템 설치 강의실에서 시스템에어컨과 팬코일유닛의 열쾌적성 및 환기성능 평가 (Evaluation of Thermal Comfort and Ventilation Performance in the Lecture Room with Ventilation System and Two Different Air-conditioning Systems: System Air-conditioner or Fan Coil Unit)

  • 한창우;노광철;오명도
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.1079-1087
    • /
    • 2005
  • In this paper, thermal comfort and ventilation performance characteristics in the lecture room with the ventilation system and two different air-conditioning systems, system air-conditioner or fan coil unit, were evaluated by experimental and numerical methods. We compared the measured data with the computational results of the predicted mean vote and carbon dioxide concentration. Additionally the ventilation effectiveness was calculated numerically. From a viewpoint of the uniformity of PMVs in the lecture room, the thermal distribution performance of the system air-conditioner was more effective than the fan coil unit. Carbon dioxide concentration and ventilation effectiveness were barely affected by the type of the air-conditioning system.