• Title/Summary/Keyword: Uninterruptible Power Supply

Search Result 199, Processing Time 0.021 seconds

Multifunctional Uninterruptible Power Supply (UPS) System

  • Kim, Je-Hong;Choi, Yong-Joon;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.813-817
    • /
    • 1998
  • This paper proposes a new control strategy of bidirectional uninterruptible power supply(UPS) with the performance of active power filter which compensate the harmonics and reactive power. To improve the transient response for the effective compensation in active power filter mode. It is considered that a simple and precise calculation method of the compensation reference current for the harmonics and reactive power compensation. So a novel closed-loop control strategy is used to calculate the reference current. The system model and control algorithm are described and the system performance is verified by the simulation and experimental results.

  • PDF

Evaluation Algorithms for Multiple Function of Dispersed Electrical Energy Storage Systems

  • Son, Joon-ho;Choi, Sung-Sik;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2245-2253
    • /
    • 2018
  • With the increase of electrical consumption and the unbalance of power demand and supply, power reserve rate is getting smaller and also the reliability of the power supply is getting deteriorated. Under this circumstance, the electrical energy storage (EES) System is considered as one of essential countermeasure for demand side management. This paper proposes efficient evaluation algorithms of multiple functions for EES systems, especially the secondary battery energy storage systems, in the case where they are interconnected with the power distribution systems. It is important to perform the economic evaluation for the new energy storage systems in a quantitative manner, because they are very costly right now. In this paper, the multiple functions of EES systems such as load levelling, effective utilization of power distribution systems and uninterruptible power supply are classified, and then the quantitative evaluation methods for their functions are proposed. From the case studies, it is verified that EES systems installed at distribution systems in a dispersed manner have multiple functions involved with direct and indirect benefits and also they can be expected to introduce to distribution systems with respects to economical point of view.

Development of 3kW Hybrid ESS with Function of Emergency Power Supply (비상전원 기능을 갖는 3kW급 하이브리드 ESS 개발)

  • Yang, Seok-Hyun;Kim, Min-Jae;Choi, Se-Wan;Cho, Jun-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.11-18
    • /
    • 2015
  • This paper proposes a high-efficiency 3-kW hybrid ESS with emergency power supply. The proposed system enables efficient use of power from photovoltaic (PV) cells and energy storage system (ESS). The proposed system can operate as an uninterruptible power supply (UPS) when grid fault occurs, providing seamless transfer from grid-connected mode to stand-alone mode. The LLC converter for PV achieves ZVS turn-on of switches and ZCS turn-off of diodes, and the isolated bidirectional DC-DC converter for ESS achieves ZCS turn-off regardless of load condition, resulting in high efficiency. The efficiency and performance of the proposed hybrid ESS has been verified by a 3-kW prototype.

Hybrid UPS with Energy Storage System Function (ESS 기능을 갖는 하이브리드 UPS)

  • Lim, Seung-Beom;Hong, Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.266-275
    • /
    • 2014
  • This paper proposes the hybrid UPS(Uninterruptible Power Supply) with ESS(Energy Storage System) function. The proposed hybrid UPS is operating in four states, which are normal state, battery state, ESS state, and bypass state. In case of peak load time or power shortage, the system is operating in ESS state in which the stored energy of the battery is used to manage the power effectively. The validity of proposed system are verified by simulations and experiments.

PFC Converter design for Uninterruptible Power Supply, including Battery Discharger (배터리 방전기 기능을 포함한 무정전전원장치의 PFC 설계)

  • Byeon, Yong Seop;Lim, Seung Beom;Kwon, Sun Man;Lee, Jun Young;Hong, Soon Chan
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.5-6
    • /
    • 2013
  • This paper proposes the PFC converter design for Uninterruptible Power Supply(UPS), including Battery discharger. Battery discharger supplies power to the inverter, when accidents occur, such as power failure, blackout, overload. To verify the validity of proposed the PFC converter design including battery discharger, simulations are carried out.

  • PDF

Battery Monitoring System for High Capacity Uninterruptible Power Supply (대용량 무정전 전원장치를 위한 배터리 모니터링 시스템)

  • Lee, Hyung-Kyu;Kim, Gi-Taek
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.580-585
    • /
    • 2019
  • Batteries are being used in ESS, electric vehicles and uninterruptible power backup systems. Lead-acid batteries are the most used batteries for high capacity power back up equipment due to their high reliability and low price advantages. It is very important to estimate the chargeable capacity(SoH), and many algorithms were proposed to estimate the internal resistance of the battery. In this paper, the Battery Monitoring System(BMS) for high capacity uninterruptible power supply for IDC is proposed. A simple algorithm for estimating internal resistance was proposed. An computational block diagram of the proposed signal processing algorithm and BMS system configuration of CPU and analog circuit were shown. The proposed method was proved useful by presenting data examples of application to actual IDC sites.

Voltage Control Strategy of new 3-phase Line-Interactive UPS System using AC Line Reactor and Parallel-Series Active Filter (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스템의 전압제어 방식)

  • Ji, Jun-Keun;Kim, Jang-Hwan;Sul, Seung-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.538-546
    • /
    • 2007
  • A new 3-phase line-interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) was introduced recently. In this paper, the strategy of voltage control in suggested UPS system is explained. The objective of proposed voltage controllers in parallel(shunt) and series PWM VSC is to guarantee satisfactory characteristics in steady state and transient state. Therefore the experimental results to prototype UPS system having power rating of 60kVA is shown to prove the verification of voltage control strategy.

Design of Digital Controller for Uninterruptible Power Supply Using Disturbance Observer

  • Cho, Jun-Seok;Lee, Seung-Yo;Mok, Hyung-Soo;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.830-835
    • /
    • 1998
  • This paper describes a new digital control method of 3-phase PWM inverter with LC filter for uninterruptible power supply(UPS). The overall control system is based on the dead beat control, which has the minor loop of current control within the voltage control major loop. In this paper, the full-order disturbance observer is proposed to compensate the disturbances generated due to a sudden change of load currents. The proposed disturbance observer is composed of dead beat observer which estimates state values within a finite time, and cancels the disturbances by adding feedforward compensation loop in the control system. In addition, on order to remove a defect of oscillation generated in output of conventional dead beat controller, a modified dead beat algorithm is proposed in this paper.

  • PDF