• Title/Summary/Keyword: Uninterruptible

Search Result 221, Processing Time 0.043 seconds

Smart Power Management Using RTOS-based Uninterruptable Generator Supply

  • Lee, Chulju;Kang, Kyungtae;Noh, Dong Kun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.6
    • /
    • pp.1-7
    • /
    • 2016
  • An uninterruptible power supply (UPS) allows small companies and domestic users to cope with power outages; but existing designs lack flexibility of control and require expensive battery maintenance, with a cost proportional to the outage compensation time. We combine a compact synchronous generator with a battery, with 10% of the capacity that would otherwise be required, to obtain a UPS with reduced maintenance costs for the same performance. Any UPS must respond immediately to a power loss, and our uninterruptible generator supply (UGS) is therefore built around real-time scheduling of its internal operations; this also makes it suitable for integration into the industrial gateway. The UGS is based on a real-time operating system, with an integrated wireless module providing connectivity to a web server, for monitoring and management, which can be performed remotely on a mobile device.

A Study on the Distortion Reducing of Output Voltage for UPS by Estimated Load Current (부하전류 예측에 의한 UPS의 출력전압 왜형률 개선에 관한 연구)

  • 변영복;박성준;추영배;권순재;김철우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.69-77
    • /
    • 1998
  • The uninterruptible power supply (UPS) has become an integral part of modern computer and communication system to assure a continued and stable operation by providing an uninterruptible power to vital equipments. Various control methods have come to the fore in recent times with the advent of high frequency switching technologies. This paper describes the DSP control method for three phase UPS inverter which guarantees the sinusoidal output voltage under nonlinear load conditions. The proposed control scheme is verified by simulation and experiment.riment.

  • PDF

Hybrid UPS with Energy Storage System Function (ESS 기능을 갖는 하이브리드 UPS)

  • Lim, Seung-Beom;Hong, Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.266-275
    • /
    • 2014
  • This paper proposes the hybrid UPS(Uninterruptible Power Supply) with ESS(Energy Storage System) function. The proposed hybrid UPS is operating in four states, which are normal state, battery state, ESS state, and bypass state. In case of peak load time or power shortage, the system is operating in ESS state in which the stored energy of the battery is used to manage the power effectively. The validity of proposed system are verified by simulations and experiments.

IHTS development for Uninterruptible power supply at UPS fault (UPS 신뢰성 향상을 위한 IHTS 개발)

  • Jeong, H.C.;Hyun, D.S.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.299-301
    • /
    • 2007
  • 본 논문은 무정전 전원공급장치(UPS : Uninterruptible Power Supply System)에서 출력이 중단되는 상황을 최종 출력단에서 감지하여, 첫째 고장 영향의 확산을 차단하고, 둘째 부하에 무정전의 전원공급을 실시할 수 있도록 하는 고속절환장치에 관한 것이다. 본 시스템은 기존 UPS 시스템이 가지고 있는 출력전원을 검출하여 기준전압 범위에서 벗어나면 절체 시키는 일반적인 방식이 아니라, 별도의 시스템을 UPS와는 독립적으로 구성하여 UPS 내부 사고시 고장이 부하와 계통상에도 영향을 주는 현상을 차단하기 위하여 절체 시점에서의 이상적인 접점 상태를 고려하고, UPS의 모든 제어시스템이 불가능한 시점에서도 부하의 연속성을 보장할 수 있도록 구성한 독립제어 고속절환장치 개발에 관한 논문이다.

  • PDF

Output Phase Synchronization Method of Inverter for Parallel Operation of Uninterruptible Power System (무정전전원장치 병렬운전을 위한 인버터의 출력 위상 동기화 방법)

  • Kim, Heui-Joo;Park, Jong-Myeon;Oh, Se-Hyung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.3
    • /
    • pp.235-241
    • /
    • 2020
  • In this paper, we propose the bus/bypass synchronization phase lock loop (B-Sync PLL) method using each phase voltage controller of a parallel UPS inverter. The B-Sync PLL included in each phase voltage control system of parallel UPS inverters has the transient response and the phase synchronization error at grid normal or blackout. The validity of this method is verified by simulation and experiment. As a result, the parallel UPS inverters using the proposed method confirmed that the output phase was continuously synchronized when a grid blackout, improving the transient response characteristics for stable load power supply and equal load sharing.

A Compensator for Lateral Current Reduction Applied to Autonomously Controlled UPSs Connected in Parallel

  • Sato Kazuhide Kazuhide;Kawamura Atsuo
    • Journal of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.312-318
    • /
    • 2005
  • This paper presents a compensator for reduction of the reactive lateral current in multiple autonomously controlled uninterruptible power supplies (UPS) connected in parallel. This compensator acts directly on the control equation for voltage amplitude and it provides an improved current distribution especially in the case of parallel connection of UPSs with different output power ratings. Observations show that the original control equation for output voltage amplitude is efficient for voltage regulation but it causes great variation of voltage levels. A compensator with the same structure is added to counterbalance the variation caused by the original control equation. Simulations show promising results with the employment of the proposed compensator. Our simulations are confirmed by experimental results using three UPSs with different output ratings and voltage limiters ($1\%$) connected in parallel under various conditions.

The Method for Replacement of Strain Pole Crossarm using the Hot-line Support Arm (핫라인 써포트암을 이용한 완철교체공법)

  • Mun, S.W.;Park, Y.B.;Kim, J.S.;Song, H.S.;Cho, S.H.;Choi, M.H.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.59-64
    • /
    • 2006
  • In this paper, developed a uninterruptible hotline tools and method for replacement of strain pole crossarm on overhead distribution line. For practical use of developed tools, following direct hot-line methods were proposed: 'Direct hot-line method for replacement of pin pole crossarm', 'Direct hot-line method for alteration of crossarm' and 'Crossarm replacement method in uninterruptible cable displacement area'. These methods were proposed more simple and safe working on hotline job.

  • PDF

Voltage Controller Using Feedforward of Single-Phase Inverter for Uninterruptible Power Supply (무정전전원장치용 단상인버터의 전향보상을 이용한 전압 제어기)

  • Hong, Chang-Pyo;Kim, Hag-Wone;Cho, Kwan-Yuhl;Lim, Byung-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.253-254
    • /
    • 2014
  • 본 논문에서는 무정전전원장치(UPS : Uninterruptible Power Supply 이하 UPS)에서 사용되는 단상인버터의 전압 제어기의 낮은 대역폭으로 인하여 발생될 수 있는 전압 위상 지연 문제를 해결한다. 제안하는 방법은 전압 명령에 대한 전향보상을 이용한 새로운 전압 제어기를 제안하고 이를 MATLAB Simulink를 사용한 시뮬레이션을 통하여 효과를 입증하였다.

  • PDF

The Development of Double Conversion Uninterruptible Power Supply Using 3-Level Converter/TNPC Inverter (3-레벨 부스트 컨버터/TNPC 인버터를 적용한 이중변환 무정전전원장치 개발)

  • Byeon, Yong Seop;Lim, Seung Beom;Choi, Kyu Hyuk;Hong, Soon Chan;Lee, Jun Young
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.83-84
    • /
    • 2014
  • This paper proposes the development of double conversion Uninterruptible Power Supply using 3-Level Converter/TNPC Inverter. The Rectifier of proposed system is operating not only 3-Level boost PFC but also battery discharger. The Inverter is converting DC voltage to AC voltage. And in terms of the efficiency, 3-Level TNPC inverter is improved compared to the origin 2-Level type. To verify the validity of proposed system, experiments were carried out.

  • PDF

Hybrid Uninterruptible Power Supply for Apartment Housing (공동주택용 하이브리드 무정전전원장치)

  • Lim, Seung-Beom;Lee, Won-Il;Kim, Myeong-Soo;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.530-531
    • /
    • 2015
  • 본 논문에서는 공동주택용 하이브리드 무정전전원장치(UPS: Uninterruptible Power Supply)를 제안한다. 제안한 하이브리드 UPS는 기존의 UPS 시스템에 DC/DC 컨버터를 추가하여 태양광 패널과 연결 가능하여 기존의 태양광 PCS(Power Conditioning Supply)의 기능을 할 수 있다. 또한 정류기를 양방향으로 동작시켜 피크 부하시나 전력 부족시 전력을 전원단으로 회생시킬 수 있어 기존의 ESS(Energy Storage System) PCS 기능도 할 수 있다.

  • PDF