• 제목/요약/키워드: Uniform electric field

검색결과 217건 처리시간 0.031초

전기장을 이용한 핵비등 열전달 촉진에 관한 실험적 연구 (Experimental study on nucleate boiling heat transfer enhancement using an electric field)

  • 권영철;김무환;강인식
    • 대한기계학회논문집B
    • /
    • 제21권12호
    • /
    • pp.1563-1575
    • /
    • 1997
  • To understand EHD nucleate boiling heat transfer enhancement, EHD effects on R-113 nucleate boiling heat transfer in a non-uniform electric field were investigated. The pool boiling heat transfer and the dynamic behavior of bubbles in d.c./a.c. electric fields under a saturated or subcooled boiling were studied by using a plate-wire electrode and a high speed camera. From the pool boiling heat transfer study, the shift of the pool boiling curve, the increase of the heat transfer and the delay of ONB and CHF points to higher heat fluxes were observed. From the dynamic behavior of bubbles, it was observed that bubbles departed away from the whole surface of the heated wire in radial direction due to EHD effects by a nonuniform electric field. With increasing applied voltages, the bubble size decreased and the active nucleation site and the departure number of bubbles showed the different trend. The present study indicates that the EHD nucleate boiling heat transfer is closely connection with the dynamic behavior of bubbles and the secondary flow induced near the heated surface. Therefore, the basic studies on the bubble behavior such as bubble frequency, bubble diameter, bubble velocity and flow characteristics are necessary for complete understanding of the enhancement mechanism of the boiling heat transfer using an electric field.

보이드 분포 형태에 따른 LDPE의 부분 방전 특성 연구 (A Study on the partial Discharge Characteristics according to the Distribution pattern of voids within LDPE)

  • 신두성;전승익;이준호;윤도홍;한민구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1081-1084
    • /
    • 1995
  • Internal voids located within an insulation will arise partial discharge that causes local breakdown and even the entire insulation breakdown. For HV apparatuses, it is usual case that several voids are formed within non-uniform electric field condition rather than single void within uniform field, which can be solved analitically. The purpose of this work is to study partial discharge and breakdown characteristics of an insulation according to the distribution pattern of two disc-type voids that are located within non-uniform field. The results from numerical field analysis and experiments show that the electric field within the voids decreases as they are arranged more serially, which accordingly results in the increase of partial discharge inception field(PDIF) much higher than that of single void model. With parallel arranged voids, PDIF is almost the same as that of single void model. On the other hand, AC breakdown strength decreases as voids are arranged more serially, which is a natural result considering the reduction of effective insulation thickness. For parallel voids, this effect cannot he noticed where as they show different pattern compared with single void and serial void models in $\Phi$-Q-N analysis. Considering these results may leads us to the conclusion that, in the evaluation of insulating products through PD test, it is not sufficient to determine only PDIV or existence of PD at predetermined voltage level. We could evaluate more accurately by considering all the available data such as PDIV, PD magnitude, PD occurring phase, number of PD pulses, and etc.

  • PDF

Electro-hydrodynamic 프로세스를 이용한 PMMA 마이크로 비드 제조방법에 대한 연구 (Research for fabricating micro-size PMMA beads using Electro-hydrodynamic process)

  • 박종하;이준희;김완두
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1509-1514
    • /
    • 2008
  • To fabricate microsized poly(methyl methacrylate)(PMMA) beads of uniform size and density on poly(ethylene terephthalate) (PET) fis, we introduce an electro spraying technique that uses a target electrode applied with an ac electric fid. Using the apparatus and various material properties, we could obtain uniform size PMMA beads which were deposited on the thin PET film. The optical properties, transmittance and light diffusivity of the fis electro sprayed with the PMMA were characterized. The results show that the sprayed beads appear to act as a good optical diffuser, like microlenses. To understand the effect of process variables, applied field conditions and rheological properties, the morphological pictures of the deposited particles were investigated through the optical and scanning electron microscope.

  • PDF

Organo-lanthanide를 이용한 OLED의 전기 전도 특성 (The Electrical Conduction Characteristics of Organo-lanthanide based OLEDs)

  • 하미영;김소연;문대규
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.412-413
    • /
    • 2006
  • The electrical conduction mechanism of ITO / Terbium tris - (1 - phenyl - 3 - methyl - 4 - (tertiarybutyryl) - pyrazol - 5 - one) triphenylphosphine oxide [$(tb-PMP)_3Tb-(Ph_3PO)$]/Mg/Al devices has been investigated. The calculation of electric field in single layer organic layer between cathode and anode shows the uniform distribution for the electron injection barrier of over 1.4 eV. The measured current-voltage curve shows well matching with the calculated curve based on the tunneling injection of electron under the uniform distribution of electric field.

  • PDF

The study of thick cell gap on the alignment of a ferroelectric liquid crystal cell

  • Wu, Jin-Jei;Wu, Po-Chang;Sie, Fu-Cheng
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.862-863
    • /
    • 2006
  • According to the experiment results, the alignment of FLC cell can become more uniform at thick cell gap by adjusting the amplitude of the aligned AC electric field which is applying to the FLC cell during $N^{\ast}-SmC^{\ast}$ phase transition. If the amplitude of AC electric field is high enough, the FLC molecules forced with the amplitude and aligned to a particular direction.

  • PDF

저항을 특성이 크게 상이한 다매질 유전체 내부의 전계 계산을 위한 표면 전하법 기법 (Electric Field Calculation of Composite Media Dielectric with Different Resistivity by Using Surface Charge Method)

  • 민석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.391-393
    • /
    • 1997
  • Two kinds of the calculation technique are Investigated with 3D triangular SCM for the arrangement of the dielectric sphere with different resistivity under a uniform electric field. The calculation error of Method I is small outside the sphere, but considerably high Inside. On the other hand, the accuracy is much Improved even Inside the solid dielectric by Method II, which uses double layers of triangular charges on the dielectric boundary.

  • PDF

시뮬레이션을 통한 스파크갭의 SF6, N2 압력 특성 분석 (Analysis of SF6, N2 Pressure Characteristic of Spark Gap According to Simulation)

  • 최순호;이태우;방정주;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제27권3호
    • /
    • pp.172-177
    • /
    • 2014
  • Industrial, medical, environment and agriculture application of pulse power technology have been developing rapidly in many field. In order to make use in the form of pulses is applied to the pulse forming technique. At this time, spark gap is generally used for the pulse forming. Spark gap may be possible to simulate the shape of the electrode, to know the uniform or non-uniform electric field of the electrode structure. Further, it can be determined using Paschen's law applied pressure of the insulating gas in accordance with the voltage which is created using the value of the electric field. In this paper, we tried to found using a formula and the simulation process to determine the pressure. The value of the electric field is different according to the shape of the electrode. So, the range of pressure applied also varies. In order to withstand the 100 kV with a gap of 5 mm, the nitrogen gas must be applied to about 7 bar in the electrode structure. On the other hand, in the same conditions, Sulfur hexafluoride gas must be applied to about 2 bar. Consequently, the Sulfur hexafluoride gas has a higher insulation properties than nitrogen gas may be applied to low pressure at the same conditions.

ELF 전자파 피폭 세포실험을 위한 배양기의 전류밀도 분포 해석 및 In Vitro 노출장치 설계 (Analysis of Current Density Distribution and In Vitro Exposur System fot ELF Exposed Cell Experiments)

  • 김대근;정재승;안재목
    • 한국전자파학회논문지
    • /
    • 제12권1호
    • /
    • pp.84-91
    • /
    • 2001
  • ELF 전자파의 생물학적인 영향 평가를 위한 in vitro 세포실험에서 노출장치의 설게는 코일내의 유도기전력(E)과 전류밀도 (J) 해석과 함께 이루어져야 한다. 균일 자기장 속에서 세포응 배양할 경우에도 배양기내의 전도성 매질오 인해 균일한 E와 J가 분포하지않는다. 따라서 균일한 ELF 자기장 노출장치로부터 발생되는 샘플 매질 내에서 E와 j를 정확히 예측하는 것은 in vitro 세포실험의 성공여부를 가늠할 정도로 매우 중요한 정보가 된다. 이에 본 논문에서는 in vitro 실험에 접합한 ELF in vitro 노출장치를 설계하고 노출장치에 대한 전자기학적 평가를 수행하였다. 코일 내에서 샘플 매질의 유무와 샘플 내에서도 세포가 놓여질 임의의 위치에 따라 E와 J를 예측하고 검증을 위한 측정과 시뮬레이션을 시도하였다. 노출장치는 헬름 홀쯔 코일로 제작되었고 자기장의 세기는 1-20G 범위 내에서 가변이 가능하다. 또한 코일내의 자기장의 분포가 균일(uniform), 비균일(non-uniform)한 두 가지 모드를 각각 제작하여 보였다.

  • PDF

Surface Discharge Characteristics Study on the Laminated Solid Insulator in Quasi-Uniform Electric Field with Dry Air

  • Min, Gyeong-Jun;Bae, Sungwoo;Kang, Byoung-Chil;Park, Won-Zoo
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.603-609
    • /
    • 2015
  • Dry air is an excellent alternative to $SF_6$ gas and is used as an insulation gas in Eco-friendly Gas Insulated Switchgears (EGISs), which has gained popularity in industry. Solid insulators in EGIS play an important role in electrical insulation. On the other hand, surface discharge can occur easily when solid insulators are used. This paper explored the surface discharge characteristics on the structure of three-layered laminated solid insulators to elevate the flashover voltage. A laminated solid insulator was inserted after the quasi-uniform electric field was formed in the test chamber. Dry air was then injected to set the internal pressure to 1 ~ 6 atm, and the AC voltage was applied. When identical solid insulators were stacked, the surface discharge characteristics were similar to those of a single solid insulator. On the other hand, the flashover voltage rose when the middle part was thicker and had lower permittivity than the top and bottom parts in the laminated solid insulator. Based on experimental results, when stacking a solid insulator in three layers, the middle part of the solid insulator should be at least four times as thick as the top and bottom parts and have lower permittivity than the others. In addition, the flashover voltage increased with increasing gas pressure on the surface of the laminated solid insulator due to the gas effect. This study may allow insulation design engineers to have useful information when using dry air for the insulation gas where the surface discharge can occur.

가스절연 원통형 관로 내의 스페이서 전계 최적화 알고리즘에 관한 연구 (Investigation on Electric Field Optimization Algorithm of Spacer in Gas Insulated System)

  • 김웅식;민석원
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권3호
    • /
    • pp.115-120
    • /
    • 2002
  • This Paper describes an algorithm for the design of axi-symmetrical spacer under specified field conditions. The electric field alas been calculated by combination method of Integral Equation Method(IEM) and Charge Simulation Method(CSM). The contour of spacer is represented with NURB(Non-Uniform Rational B-spline) curve of which effectiveness has been proved. This algorithm introduces a design process in the aspect of electrical field, when a spacer in airtight cylinder is designed. Also various field conditions for obtaining optical shapes have been proposed. Due to the algorithm, the entire process shows a stable convergence. Both tangential and total electrical field are taken into consideration as specified field criteria.