• Title/Summary/Keyword: Uniform Commercial Code

Search Result 58, Processing Time 0.022 seconds

Heat Transfer Analysis of Friction Welding of A2024 to SM45C (A2024 와 SM45C 마찰용접의 열전달 해석)

  • 이상윤;윤병수
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.1
    • /
    • pp.65-70
    • /
    • 2001
  • The hear transfer mechanism initiating the friction welding is examined and a transient three dimensional heat conduc-tion model for the welding of two dissimilar cylindrical metal bars is investigated. The cylindrical metal bars are made of materials made of A2024 and SM 45C. Numerical simulations of heat flow are performed using the finite volume method. Respectively. Commercial FLUENT code is used in the heat flow simulation and maximum temperature and distribution of temperature are calculated. Temperature of friction welded joining face is compared with the temperature distribution measured by experiment and numerical simulation. The maximum temperature of friction welded joining face is lower than melting point of A2024-T6 aluminum alloy using insert metal. The temperature distribution of friction welded join- ing face with insert metal is more uniform than that of without inset metal.

  • PDF

Prevention of local overheating of a radiant tube heater (열처리용 복사튜브의 국부 과열 해소)

  • Kim H. S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.08a
    • /
    • pp.119-125
    • /
    • 2004
  • Radiant tube heaters are widely used for indirect heating in heat treatment processes such as continuous annealing line(CAL) or continuous galvanizing line(CGL). Main issues for radiant tube are temperature uniformity, lifetime, thermal efficiency. To achieve higher heat release, the radiant tubes are fired at a higher fuel rate and therefore local overheating occur. A numerical simulation based on a commercial code FLUENT has been performed to investigate local overheating of radiant tube heaters. To minimize local overheating, the effects of radiating fins, flue gas recirculation(FGR), two-stage combustion were investigated. More uniform temperature distribution was achieved in the longitudinal direction within the tube with radiating fins and this contributed to increase the life of radiant tubes. Furthermore, the radiant tube with radiating fins was proven to be more efficient than the one without fins. The effects of flue gas recirculation and two stage combustion on the efficiency of the radiant tube were also considered and the results were presented.

  • PDF

Flow Analyses around the Battery Pack for a NEV (전기자동차용 배터리 팩 주위의 유동장 해석)

  • Kim, H.S.;Han, B.Y.;Park, H.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.135-140
    • /
    • 2011
  • The battery pack, a main component of NEV(Neighborhood Electric Vehicle), needs cooling system when it is charging or discharging to prevent the degradation of the battery charging efficiency. The purpose of this study is to analyse the effects of cooling methods, changing positions of inlet and outlet and changing area ratios of inlet and outlet. It has been observed that in the point of uniform cooling suction from the exit side is more efficient than blowing from the inlet. And there is a suitable inlet/outlet area ratio in maximizing the mass flow rate. The numerical analyse using a commercial code STAR-CCM+ version 4.02 were used for the study.

  • PDF

A Study on Uniform Commercial Code Article 5-109 (미국통일상법전(美國統一商法典) 제(第)5-109조(條)에 대한 일고찰(一考察))

  • Kim, Soon-Ja
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.13
    • /
    • pp.537-561
    • /
    • 2000
  • In these days, there are various types of fraud in L/C transaction. But we has no article on fraud in the UCP. So the matter of fraud has been depended on the judgement of court of each country. But the judgements are different in each case. These cause the difficulties in practice. To solve this problem, it is desirable to insert the relative article in the UCP. I considered the article 5-109 of UCC for pre-study on this matter. But the article 5-109 of UCC has some problems. To arrange the relative article on fraud in the UCP, we have to consider more severely on article 5-109 of UCC. Especially, it should be studied on cases in practice. This is left for next study.

  • PDF

Study on the unidirectional compaction of terminal cables in the CICC joint

  • 남현일;이호진;박재학;홍계원
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.218-223
    • /
    • 2002
  • The void volume fraction of cables is one of the effective parameters to characterize the joints of superconducting magnet. Because electrical resistance and cooling stability in the CICC (Cable-in-Conduit Conductors) joint are governed by the void volume fraction, it should be controlled constantly in the termination of cable. The change of cross-section shape in the cable was fecund during the unidirectional compaction of terminal sleeve. The non-uniform thickness of the sleeve after compaction is expected because the loading is not taxi-symmetric, and the plastic flow is also not axi-symmetric. The CICC was compacted from 45% void volume fraction to 15% by using two-piece compaction jig, which could be pressed mini-directionally. Commercial code, ABAQUS, was used to analyze the plastic flow in the sleeve during the unidirectional compaction. The increment of radius of curvature of compaction jig could minimize the change of the deformed shape of cables. The calculated results were agreed with the experimental observations.

  • PDF

A study on Flow Characteristic inside Passenger's Compartment under Recirculation Cool vent mode using CFX (CFX를 이용한 내부순환모드에서의 자동차 내부 유동특성 연구)

  • Kim, Yoon-Kee;Yang, Jang-Sik;Kim, Kyung-Chun;Ji, Ho-Seong
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • The flow characteristics under recirculation cool vent mode is numerically studied using commercial fluid dynamic code(CFX). For the reliable analysis, real vehicle and human FE model is employed in grid generation process. The geometrical location and shape of panel vent, and exhaust vent is set as that of real vehicle model. The flowrate of the working fluid is determined as 330CMH which is equivalent to 70 percent of maximum capacity of HVAC system. The high velocity regions are formed around 4 each panel vent. Because of the non-symmetrically located exhaust, non-uniform flow and partial backflow near the door trim is observed. Streaklines start from each panel vent show the flow pattern of the airflow in the passenger's compartment very well.

Effects of Flow Settling Means on the Performance of Fan Tester (유동안정화 장치가 홴 테스터의 성능에 미치는 영향)

  • Choi Young-Seok;Kim Deok-Su;Yoon Joon-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.4 s.37
    • /
    • pp.43-48
    • /
    • 2006
  • In this study, the effect of flow settling means on the performance of fan tester were numerically investigated by using a computational fluid dynamics(CFD). The airflow rate was calculated from the pressure differential across a flow nozzle in the measuring plane and the flow settling means were generally installed in the chamber of the fan tester to provide proper airflow patterns ahead of the measuring plane. The predicted nozzle differential pressures with uniform inlet velocities were compared with the values of the ANSI/AMCA 210-99 to verify the performance of the commercial CFD code CFX 5.6. The influence of flow settling means on the measurement of airflow rate in a fan tester were discussed with various porosities and inlet jet velocities. The results obtained show that the proper band of porosities exist to meet the AMCA standard in a specified inlet jet velocity.

FLOW ANALYSES AROUND THE BATTERY PACK FOR A NEV (전기자동차용 배터리 팩 주위의 유동장 해석)

  • Kim, H.S.;Han, B.Y.;Park, H.K.
    • Journal of computational fluids engineering
    • /
    • v.16 no.3
    • /
    • pp.82-87
    • /
    • 2011
  • The battery pack, a main component of NEV(Neighborhood Electric Vehicle), needs cooling system when it is charging or discharging to prevent the degradation of the battery charging efficiency. The purpose of this study is to analyse the effects of cooling methods, changing positions of inlet and outlet and changing area ratios of inlet and outlet. It has been observed that in the point of uniform cooling, suction from the exit side is more efficient than blowing from the inlet. And there is a suitable inlet/outlet area ratio in maximizing the mass flow rate. A commercial code, STAR-CCM+(ver. 4.02), was used for the numerical study.

A Study on The Performance of Supersonic Cascade with The Nozzle Inlet Boundary

  • Shin, Bong-Gun;Jeong, Soo-In;Kim, Kui-Soon;Lee, Eun-seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.839-847
    • /
    • 2004
  • In this study, the flow characteristics within supersonic cascades are numerically investigated by using Fine Turbo, a commercial CFD code. Cascade flows are computed for three different inlet conditions. : a uniform supersonic inlet condition, a linear nozzle and a converging-diverging nozzle located in front of cascades. The effect of inlet conditions is compared and flow characteristics including shock patterns and shock-boundary layer interaction are analyzed. Also the effect of design parameters such as pitch-chord ratio, blade angle and blade surface curvature on the flow within supersonic cascades are studied.

  • PDF

A Legal Study on the Standard for Conformity of the Goods in the International Sale of Goods (국제물품매매계약상(國際物品賣買契約上) 물품일치성(物品一致性)의 기준(基準)에 관한 법리적(法理的) 고찰(考察))

  • Song, Myeong-Bok
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.12
    • /
    • pp.133-162
    • /
    • 1999
  • The international sale transaction is in essence a sale of goods and presents all those commercial and legal problems in any sale of goods. As a result, A International sales contract imposes several duties on the parties : the seller must deliver the goods and transfer ownership in them, while the buyer must pay the price and take delivery of the goods. However, there are several problems which impede a active transaction between seller and buyer who have their places of business in other countries each other. Therefore, It is necessary to provide the concept on the conformity of goods in the Int'l Sale of Goods. Especially, In our consideration for the point of time when defects occurs, the existence of non-conformity of goods should be judged on the basis of time of delivery rather than time of contract. Moreover, The burden of proof about nonconformity of goods is another fact which make an international dispute between the contractual parties in an international trade. Thus, The consistency in the interpretation of law must be maintained betweened the warranty and seller's liability. In the Uniform Commercial Code and UN Convention, non-conformity of contract is made of contract liability. And in our civil and commercial law provisions of warranty should be understand as the special ones of the provisions of general non-performance of obligation liability. As a result, More concrete study of them is required because they may have a great influence especially on international trade. As a result, We should be our best in finding a helpful and systematic structure that the dualistic structure of nonperformance of obligation liability and warranty liability must be unified by studying the theories of English and American warranty and our legal system, as well as international practice and usage being used in an international trade.

  • PDF